• 제목/요약/키워드: FSR(force sensing resistor) sensor

검색결과 16건 처리시간 0.024초

Measurement and analysis of body pressure distribution on a bed

  • 박세진;황민철;김창범
    • 대한인간공학회:학술대회논문집
    • /
    • 대한인간공학회 1995년도 춘계학술대회논문집
    • /
    • pp.55-61
    • /
    • 1995
  • We spend about 40% of lifte time on a bed and seek how such amount of time is spent comfort. Bed comfort has been pursuited. The pressure distributions on a bed by body pressure has been considered as one of the most important factors of bed comfort. This study is to quantify the subjective assessment by the body pressure distribution and develop the objective evaluation method of bed comfort. A new measurement system for body pressure on a bed was developed in this study. The thin film pressure sensor (FSR: Force Sensing Resistor) of an elastomer-type was used to prevent the distortion of contact pressure. The pressure distribution is measured by FSR and displayed on the monitor by color-coded contour patterns. Some of the bed test results were described. And the relations between body pressure distribution and bed comfort were evaluated.

  • PDF

근전도와 저항 센서를 이용한 보행 단계 감지 (Gait Phases Detection from EMG and FSR Signals in Walkingamong Children)

  • 장은혜;지수영;이재연;조영조;전병태
    • 감성과학
    • /
    • 제13권1호
    • /
    • pp.207-214
    • /
    • 2010
  • 본 연구에서는 근전도 신호를 활용하여 정상인의 보행과 관련된 상지와 하지 근육의 신호를 확인하고 저항센서를 이용하여 정상적인 보행 패턴을 확인하였다. 대학생 15명을 대상으로 정지해 있을 때와 평지를 보행할 때, 상지의 4부위(대흉근과 승모근)와 하지의 10부위(대퇴직근, 대퇴이두근, 내측광근, 외측광근, 반막양근, 반건양근, 가자미근, 장비골근, 내비복근과 외비복근)에 전극을 부착하여 근전도를 측정하였다. 저항센서는 양측 발바닥의 8부위에 센서를 부착하여 보행시 발에 가해지는 압력을 측정하였다. 그 결과, 근전도 신호는 정지상태에 비하여 보행 시에 허벅지의 외측광근과 반건양근을 제외하고 모든 근육에서 유의하게 높은 진폭을 가졌다. 또한 보행주기의 두 단계인 입각기와 유각기와 관련된 근육을 확인하였다. 저항 센서의 신호 분석 결과, 평균 보폭 주기 동안 크게 입각기와 유각기의 두 주기와 세부적으로 여덟 단계 - 초기 접지기, 하중 반응기, 중간 입각기, 말기 입각기, 전 유각기, 초기 유각기, 중간 유각기, 말기 유각기 - 의 보행 주기를 확인할 수 있었다.

  • PDF

Development of a Portable Gait Phase Detection System for Patients with Gait Disorders

  • Ahn Seung Chan;Hwang Sung Jae;Kang Sung Jae;Kim Young Ho
    • 대한의용생체공학회:의공학회지
    • /
    • 제26권3호
    • /
    • pp.145-150
    • /
    • 2005
  • A new gait detection system using both FSR (force sensing resistor) sensors and a gyrosensor was developed to detect various gait patterns. FSR sensors were put in self-designed shoe insoles and a gyrosensor was attached to the heel of a shoe. An algorithm was also developed to determine eight different gait transitions during four gait phases: heel-strike, foot-flat, heel-off and swing. The developed system was evaluated from nine heathy mans and twelve hemiplegic patients. Healthy volunteers were asked to walk in various gait patterns: level walking, fore-foot walking and stair walking. Only the level walking was performed in hemiplegic patients. The gait detection system was compared with a optical motion analysis system and the outputs of the FSR sensors. In healthy subjects, the developed system detected successfully more than $99\%$ for both level walking and fore-foot walking. For stair walking, the successful detection rate of the system was above$97\%$. In hemiplegic patients, the developed system detected approximately 98% of gait transitions. The developed gait phase detection system will be helpful not only to determine pathological gait phases but also to apply prosthetics, orthotics and functional electrical stimulation for patients with various gait disorders.

이족 보행 로봇의 보행 안정화 및 RFID를 이용한 경로 추종에 관한 연구 (A Study on Walking Stabilization and Path Tracking of Biped Robot Using RFID)

  • 박종한;김용태
    • 한국지능시스템학회논문지
    • /
    • 제23권1호
    • /
    • pp.51-56
    • /
    • 2013
  • 이족 보행 로봇을 실생활에 적용하기 위해서는 다양한 환경에서의 강인한 보행 뿐만 아니라, 현재 위치를 인식하여 목표 위치로의 경로를 생성하고, 경로를 추종하는 기능이 요구된다. 최근에 많이 사용되고 있는 RFID는 이동 로봇의 위치인식 및 경로 생성에 손쉽게 활용이 가능하다. 그러나 이족 로봇은 보행시에 불안정성을 내포하고 있어 주어진 경로에서 벗어나기 쉽다. 본 논문에서는 FSR(Force Sensing Resistor)센서, 자이로와 가속도 센서를 이용하여 이족 보행 로봇의 보행 안정화 방법을 제안하였다. 또한 양발에 RFID 센서를 장착하여 이족 보행 로봇의 위치 인식 후 경로를 추종하는 알고리즘을 제안하였다. 제안된 보행 안정화 알고리즘은 실제 제작된 이족 보행 로봇을 이용하여 비평탄 지형에서 실험하여 검증하였으며, 경로 추종 실험은 RFID센서를 로봇의 발바닥에 장착하여 평탄 지형에서 보행실험을 통해 검증하였다.

저항 센서와 기울기 센서의 융합에 의한 보행 의도 감지 (Walking Intention Detection using Fusion of FSR and Tilt Sensor Signals)

  • 장은혜;전병태;이재연;지수영;강상승;조영조
    • 감성과학
    • /
    • 제13권3호
    • /
    • pp.441-448
    • /
    • 2010
  • 보행보조로봇은 고령화 사회에 노인 복지 및 중증 신경계 손상을 입은 환자에게 이동을 도울 수 있는 반드시 필요한 장비이다. 특히, 하지 마비 환자를 위한 보행보조로봇의 편리성을 위해서는 환자의 보행 의도를 내현적으로 파악함으로써 환자 의지에 따라 로봇을 통제할 수 있어야 한다. 본 논문은 보행 의도 감지 모델을 개발하기 위한 선행 연구로, 먼저 저항 센서와 기울기 센서의 융합을 통하여 3족 보행 모델을 기반으로 사용자의 보행 의도를 분석하였다. 저항 센서는 사용자의 양쪽 손바닥과 발바닥에 각각 부착되어, 부착된 위치의 압력을 센싱하였다. 양쪽 손바닥의 신호는 보행 의도를 파악하기 위해, 발바닥의 신호는 보행 단계를 확인하기 위하여 사용되었다. 기울기 센서는 몸의 움직임 상태를 측정하기 위한 센서로서, 사용자의 등 부분, 요추에 부착되어 상체의 움직임(roll, pitch)을 센싱하였다. 연구 결과, 사용자가 지팡이를 바닥에 짚을 때 양 손바닥에서 측정되는 2개의 저항 신호만으로 기본적인 보행 의도를 파악할 수 있었으나, 기울기 센서 정보를 함께 이용함으로써 오른발 뻗기, 왼발 뻗기 등의 움직임을 시작하려는 상태 등에 대한 보행 의도를 보다 구체적으로 확인할 수 있었다. 결론적으로, 본 연구를 통하여 저항센서와 기울기 센서의 융합에 기반한 사용자의 보행 의도를 감지할 수 있었다.

  • PDF

요추 관절가동범위와 신체압력중심을 이용한 신체균형능력 분석 및 훈련 콘텐츠 (Analysis and Training Contents of Body Balance Ability using Range of Motion of Lumbar Spine and Center of Body Pressure)

  • 구세진;김동연;신성욱;정성택
    • 한국인터넷방송통신학회논문지
    • /
    • 제19권1호
    • /
    • pp.279-287
    • /
    • 2019
  • 본 논문에서는 신체의 움직임 정보와 족압 분포의 변화를 측정하여 신체 균형 능력을 분석하고자 하였다. 그래서 관성측정장치와 FSR 센서를 사용하여 관절가동범위와 신체압력중심을 측정하고 분석할 수 있는 프로그램을 개발하였고, 이에 대한 결과를 바탕으로 균형 능력 개선에 도움을 줄 수 있는 콘텐츠를 제작하였다. 이 프로그램에서 측정된 관절가동범위와 신체압력중심의 정량적인 값을 실시간으로 시각화하여 사용자가 결과를 쉽게 알 수 있도록 하였다. 또한 콘텐츠는 측정된 균형정보를 바탕으로 난이도가 조절되며 균형능력을 개선하고자 하는 방향에 맞춰 수행할 수 있도록 제작되었다. 이것은 사용자의 동작에 따라 움직이는 물체를 보면서 진행하는 시각 되먹임 방법을 이용하여 집중력과 참여의지를 높여 더욱 효과적인 균형 훈련 결과를 기대할 수 있다.