• Title/Summary/Keyword: FS

Search Result 1,252, Processing Time 0.045 seconds

Comparative Studies on Detecting Methods of Fecal Indicators (Coliforms) in Surface Water (지표수에서의 분변오염지표세균 (대장균군) 검출방법의 비교연구)

  • Park, Ji-Eun;Kim, Sun-Duck;Cho, Ju-Rae;Kim, Sang-Hyun;Lee, Hae-Jin;Lee, Young-Ok
    • Journal of Korean Society on Water Environment
    • /
    • v.22 no.6
    • /
    • pp.1052-1059
    • /
    • 2006
  • For monitoring the fecal pollution at Nak-Dong River, one of the eutrophicated rivers, the differences between total coliforms (TC) and fecal coliforms (FC) using both of membrane filtration (MF)/MPN method, and also fecal streptococcus (FS) by MF-method was investigated. To evaluate the correlation between TC, FC, and FS statistical analyses were performed by using Minitab. And a part of the presumptive TC/FC and background colonies was purified and identified using API 20E kit (Biomeriux). As results, most (89%) of presumptive FC by MF was identified as Escherichia coli while only 14% (MPN) and 11% (MF) of TC were identified as E. coli. Furthermore, FC by MF was correlated significantly with other fecal indicators (TC/FS by MF and FC by MPN), while TC by MPN was not correlated with any other indicators. Thus, the detection of FC by MF-method may be the most reasonable for monitoring the fecal pollution.

A Clinical Case Report on Multiple Sclerosis Treated by Korean Medicine (다발성 경화증에 대한 한방치료 치험 1례)

  • Jeon, Yong-Tae;Park, Sang-Hun;Ko, Youn-Seok
    • The Journal of Churna Manual Medicine for Spine and Nerves
    • /
    • v.9 no.2
    • /
    • pp.21-33
    • /
    • 2014
  • Objectives : This study was to report the improvement of the patient with multiple sclerosis treated by Korean Medical treatment. Methods : The patient diagnosed as multiple sclerosis treated by acupuncture, bee venom pharmacupuncture, chuna manual therapy, and herbal medicine. To evaluate the effects of korean medicine, we used manual muscle test(MMT), the standard for assessment of the effect of stroke treatment, functional system(FS), visual analog scale(VAS). Results : 1. The patient's pain and optic dysfunction were reduced by the above therapy. 2. There was no change in manual muscle test(MMT), but there was mild improvement in finger joints function in the standard for assessment of the effect of stroke treatment. 3. In functional system(FS) scale, there was enhancement in optic function within a range. And there was improvement in expanded disability statue scale(EDSS) from 4.0 to 3.0. 4. In visual analog scale(VAS), there was considerable improvement from 9 to 6. Conclusions : The korean medical treatment was reduced pain and optic dysfunction.

  • PDF

A Proposal of Parameter to Predict Biaxial Fatigue Life for CF8M Cast Stainless Steels (CF8M 주조 스테인리스강의 2축 피로수명 예측을 위한 파라미터의 제안)

  • Park Joong Cheul;Kwon Jae Do
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.29 no.6 s.237
    • /
    • pp.815-821
    • /
    • 2005
  • Biaxial low cycle fatigue test was carried out to predict fatigue life under combined axial-torsional-loading condition which is that of in-phase and out-of-phase for CF8M cast stainless steels. Fatemi-Socie(FS) parameter which is based on critical plane approach is not only one of methods but also the best method that can predict fatigue life under biaxial loading condition. But the result showed that, biaxial fatigue life prediction by using FS parameter with several different parameters for the CF8M cast stainless steels is not conservative but best results. So in this present research, we proposed new fatigue life prediction parameter considering effective shear stress instead of FS parameter which considers the maximum normal stress acting on maximum shear strain and its effectiveness was verified.

Design and Evaluation of the Tension Sensor for Surgical Steel Wires (수술용 강선에 대한 인장력 측정센서의 설계 및 특성평가)

  • Joo, Jin-W;Lee, Bong-S
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.21 no.2
    • /
    • pp.261-271
    • /
    • 1997
  • This paper presents the design process and characteristic test results of tension sensors for measuring the ultimate tension forces of surgical wires. Three types of sensor were designed and tested for calibration. The first two types which transfer the wire tension to the sensing element by direct contact have too much hysterisis errors due to the firctional effect. This error can be considerably reduced in the modified structure, where a cover and a loading button is used to transfer force and moment to the sensing element. The strains predicted by theoretical equations agree well with those by finite element calculations neglecting friction and the strains by finite element analysis considering friction are in good agreement with those measured by four strain gages. The modified ring type tension sensor developed in this paper is expected to be useful for measuring the tension of surgical wires with nonlinearity of 1.31%FS, hysterisis of 5.74%FS and repeatability of 0.19%FS.

Determination of PCDD/Fs in Disposable Diaper for Infant (유아용 일회용 기저귀의 다이옥신 분석)

  • Shin Jeoung Hwa;Ahn Yun Gyong;Seo Jung Ju
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.29 no.6
    • /
    • pp.814-824
    • /
    • 2005
  • This study analyzed and standardized the harmful substances of organic compounds(dioxins) in disposable diapers for infant's clothing. Commercial samples obtained from Korea, Japan, America and German were determined by HRGC/HRMS. Experimental Methods were consisted of comparision of extracting solvent, analysis of PCDD/Fs, and analysis of PCDD/Fs of extraction in disposable diaper. The results were as follows. No high TEQ values in TCDD(1), PCDD(0.5) and HxCDD(0.1) were found for commercial disposable diapers from country Korea, Japan, U.S.A and German. In extraction for 6hrs experiments, HpCDD and OCDD were detected in disposable diapers of U1, U2 and G2, respectively. In extraction fur 24hrs experiments, HpCDD, OCDD and OCDF were detected in disposable diapers of J3, U1, U2 and U3. So we need to set standards of measurement for harmful materials contained in textile goods. This will make a safe and comfortable clothing environment for all users, regardless of age.

Numerical analysis of fs laser ablation of metals (금속의 펨토초 어블레이션의 수치해석)

  • Oh B.K.;Kim D.S.;Kim J.G.;Lee J.H.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.657-658
    • /
    • 2006
  • Although there are many numerical models to simulate fs laser ablation of metals, no model can analyze the ablation phenomena over a wide range of fluence. In this work, a numerical code for simulating the fs laser ablation phenomena of metals has been developed. The two temperature model is employed to predict the ablation rate and the crater shape of metals using phase explosion mechanism in the relatively high fluence regime. Also, the ultrashort thermoelastic model is used for the low fluence regime to account for spallation of the sample by high strain rate. It has been demonstrated that the thermoelastic stress generated within the sample can exceed the yield stress of the material even near the threshold fluence. Numerical computation results are compared with the experiment for Cu and Ni and show good agreement. Discussions are made on the hydrodynamic model considering phase change and hydrodynamic flow.

  • PDF

One-round Secure Key Exchange Protocol With Strong Forward Secrecy

  • Li, Xiaowei;Yang, Dengqi;Chen, Benhui;Zhang, Yuqing
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.10 no.11
    • /
    • pp.5639-5653
    • /
    • 2016
  • Security models for key exchange protocols have been researched for years, however, lots of them only focus on what secret can be compromised but they do not differentiate the timing of secrets compromise, such as the extended Canetti-Krawczyk (eCK) model. In this paper, we propose a new security model for key exchange protocols which can not only consider what keys can be compromised as well as when they are compromised. The proposed security model is important to the security proof of the key exchange protocols with forward secrecy (either weak forward secrecy (wFS) or strong forward secrecy (sFS)). In addition, a new kind of key compromise impersonation (KCI) attacks which is called strong key compromise impersonation (sKCI) attack is proposed. Finally, we provide a new one-round key exchange protocol called mOT+ based on mOT protocol. The security of the mOT+ is given in the new model. It can provide the properties of sKCI-resilience and sFS and it is secure even if the ephemeral key reveal query is considered.

A Solid-Phase Extraction Method for Analyzing Trace Amounts of Polychlorinated Dibenzo-p-Dioxins and Dibenzofurans in Waste Water

  • Park, Deok-Hie;Youn, Yeu-Young;Choi, Jae-Won;Lim, Young-Hee;Cho, Hye-Sung
    • Mass Spectrometry Letters
    • /
    • v.2 no.1
    • /
    • pp.12-15
    • /
    • 2011
  • The Korean government has regulated emission of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) in waste water of manufacturing facilities producing chlorinated compounds since 2009. As this regulation is expected to be reinforced in 2013 to 50 pg I-TEQ/L, a large sample volume is required for the analysis of trace amounts of PCDD/Fs in waste water. Liquid-liquid extraction (LLE) is used to extract PCDD/Fs from aqueous samples; however, its low efficiency makes it inadequate for analyzing large sample volumes. Herein, we present a disk-type solid-phase extraction (SPE) method for the analysis of dioxin at a part per quadrillion level in waste water. This SPE system contains airtight glass covers with a decompression pump, which enables continuous semi-automated extraction. Small (0.5 L) and large (7 L) samples were extracted using LLE and SPE methods, respectively. The method detection limits (MDLs) were 0.001.0.25 and 0.015.4.1 pg I-TEQ/L for the SPE and LLE methods, respectively. The concentrations of detected congeners with both methods were similar. However, the concentrations of several congeners that were not detected with the LLE method were quantified using the SPE method.

Comparison of Free-Surface Boundary Conditions for Computing Wave Resistance (조파저항 계산을 위한 자유표면 조건의 비교)

  • Suak-Ho Van;Seung-Joon Lee
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.30 no.2
    • /
    • pp.54-65
    • /
    • 1993
  • In computing the wave resistance numerically, satisfying the boundary condition(BC) on the body surface is not so difficult, and then what form of the BC on the free surface(FS) be used is a crucial question. To shed some light on this, we examine the various BC's on the FS, namely, the Poisson's[1], the Ogilvie's[2] and the Dawson's[3] BC, using the same panel method for submerged bodies in two-dimension. We also show the performance of the Poisson's BC for a submerged sphere and the Wigley hull. It seems that we are still in need of a theory which gives a BC on the FS more accurate than those tested, and more practically applicable than the exact nonlinear BC.

  • PDF

The Changes of Component in Traditional Korean Soy Sauce During Ripening Period(I) (숙성기간에 따른 재래 간장의 성분변화(I))

  • 정혜정;손경희
    • Korean journal of food and cookery science
    • /
    • v.10 no.1
    • /
    • pp.29-34
    • /
    • 1994
  • In this stydy, Korean traditional Meju adjusted with: the salt contents of 12%, 16%, 20% and the ripeming periods of 90, 135 and 180 days. The results were summerized as follows; 1 The changes of moisture content in soy sauce by 16% salt content was slightly high and the protein was 5.88 by 12%, salt content 2. As the ripening periods was increased, the pH was decreased, on the other hand the total acidity was increased slightly. 3. In the 180 day ripened sample, the salt content increa-sed and the 12% salt content represented 30.6ft salt content. 4. The reduced sugar decreased 135 day ripening, but it increased 180 day ripening at 12fs, 16fs, 20fs salt content. 5. The amino acid content siginificantly decreased by salt content (Serine, Arginine), ripeming periods (Glutamic acid, Asparagine, Glycine, Threomine, Alanine, Methionine, Valine, Isoleucine, Lysine) and ripening time and salt content (Phenylalanine, Leucine) 6. The Fe content decreased 12% salt content while it increa-sed 16% 20% salt content. 7. According to the ripening time, there were significant changes in color, clearance, taste, flavor and over all acceptabilities. As the lower the acceptabilities on flavor or taste increase.

  • PDF