• 제목/요약/키워드: FRP composites

검색결과 225건 처리시간 0.026초

콘크리트 표면처리와 CFRP 단부정착 방법에 따른 부착특성실험 (Experimental Study on the Bond[ Behavior with Concrete Surface Preparation. and Anchorage Type of CFRP)

  • 유영준;조정래;정우태;박종섭;박영환
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2003년도 봄 학술발표회 논문집
    • /
    • pp.579-584
    • /
    • 2003
  • For strengthening deteriorated concrete structures, externally bonded FRP sheets or plates using epoxy resins are widely used. For the external FRP composites to be effective in improving the performance of the structure, bond between FRP composites and concrete is required. In general, the most frequently observed failure mode in FRP strengthened concrete structures is debonding failure at the interfacial section between FRP and concrete. Therefore, it is very important to find out the interfacial behavior properties. This paper presents experimental results of the relationship of concrete and FRP sheet for some conditions including concrete compressive strength, concrete surface preparation to observe the bond behavior between concrete and FRP sheet and various anchorage types to increase the bond capacity of FRP sheet.

  • PDF

FRP로 전단보강된 철근콘크리트 보의 비선형 해석 (Nonlinear Analysis of Reinforced Concrete Beams Shear-Strengthened with Fiber Reinforced Polymer Composites)

  • 김상우;황현복;이범식;이정윤
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2008년도 추계 학술발표회 제20권2호
    • /
    • pp.835-838
    • /
    • 2008
  • 이 연구에서는 FRP(fiber reinforced polymer)로 전단보강된 철근콘크리트(RC) 보의 전단거동을 예측하기 위하여 비선형 유한요소해석을 수행한다. FRP로 전단보강된 RC 보의 유한요소해석을 위하여 이 논문에서는 FRP에 대한 모델링 개념을 소개하며, RC 보와 FRP, 그리고 콘크리트와 FRP 사이의부착 특성을 나타낼 수 있는 수치해석기법을 사용한다. 제안된 모델링 기법에 따라, DSFM에 바탕을둔 2차원 비선형 유한요소해석 프로그램인 VecTor2를 이용하여 유한요소해석을 수행한다. 또한 FRP 로 전단보강된 RC 보의 거동에 대한 DSFM의 적용성을 검증하기 위하여 수치해석결과와 실험결과를 상세히 비교한다.

  • PDF

FRP 복합체의 자외선 저항성에 관한 실험적 연구 (Experimental Study on Ultra-Violet Resistance of FRP composites used in Strengthening RC members)

  • 송태협;최기선;유영찬;김긍환
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 춘계 학술발표회 논문집(II)
    • /
    • pp.333-336
    • /
    • 2006
  • In general, polymer materials undergo degradation when exposed to ultraviolet radiation, which can cause dissociation of chemical bonds. FRP composites which are used in strengthening existing structure are usually adhered on the concrete surface, its mechanical properties as well as appearance such as color, surface conditions are affected by sunlight and expecially ultraviolet light. In this study, variations of tensile strength after exposure for certain period of time through accelerated exposure by Xe arc methods specified in KS F 2274 are measured in order to examine strength degradation characteristics of FRP composite. As a result of ultraviolet light test for FRP composite after accelerated exposure for 0, 500, 1000, 1500 hour, discoloration of FRP composite occurs according to the passage of time. But, few strength degradations of FRP composite are observed due to exposure of ultraviolet ray with an small variation of tensile strength.

  • PDF

FRP 복합체의 동결융해 및 고온.고습 저항성에 관한 실험 연구 (Experimental Study on Freezing-Thawing and Warm-Moisture Resistance of FRP Composites used in Strengthening RC Members)

  • 최기선;유영찬;이한승;김긍환
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 춘계 학술발표회 논문집(II)
    • /
    • pp.345-348
    • /
    • 2006
  • FRP composites which are used in strengthening existing structure are usually adhered to the concrete surface, their performance are directly affected by environmental condition such as freezing-thawing and moisture. Accordingly, it is required to evaluate bond durability between FRP composite and concrete as well as FRP materials itself. The durability characteristics of FRP composite for freezing-thawing are evaluated in this study with the variables of concrete strength, type of FRP composite, freezing-thawing conditions and freezing-thawing cycle. In addition, material durability of GFRP sheet for high temperature/high humidity condition are examined in this experimental study.

  • PDF

FRP복합체로 보강된 실물모형 RC보의 보강재 강성에 따른 휨 보강성능 (Flexural Performance of Full-scale RC Beams Strengthened with Different Amount of FRP Composite)

  • 최기선;유영찬;김긍환
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 추계 학술발표회 논문집
    • /
    • pp.125-128
    • /
    • 2006
  • Many research have been carried out concerned with the flexural performance of FRP composite in a various ways. Most of them, however, have used a small-scale specimen, so haven't been fully verified by full-scale model test. In this study, a full-scale RC beam model test for flexural strengthening with CFRP composites has been performed in order to verify test results obtained through a series of small-scale model test with respect to FRP stiffness affecting strengthening performance in the previous studies. A total of 4 specimens have been manufactured including control beam. The specimens strengthened with CFRP composites consist of 3 different CFRP stiffness with 2 types of CFRP composite. Consequently, the purpose of this study is to estimate influence of the size effect of specimens and FRP stiffness on the flexural performance. As a result, the effective strain of FRP composite is inversely proportional to FRP stiffness and ensures the same performance with small-scale model test.

  • PDF

Shear strengthening of reinforced concrete beams with rectangular web openings by FRP Composites

  • Abdel-Kareem, Ahmed H.
    • Advances in concrete construction
    • /
    • 제2권4호
    • /
    • pp.281-300
    • /
    • 2014
  • This study presents the experimental results of twenty three reinforced concrete beams with rectangular web openings externally strengthened with Fiber Reinforced Polymers (FRP) composites bonded around openings. All tested beams had the same geometry and reinforcement details. At openings locations, the stirrups intercepted the openings were cut during fabrication of reinforcement cage to simulate the condition of inclusion of an opening in an existing beam. Several design parameters are considered including the opening dimensions and location in the shear zone, the wrapping configurations, and the amount and the type of the FRP composites in the vicinity of the openings. The wrapping configurations of FRP included: sheets, strips, U-shape strips, and U-shape strips with bundles of FRP strands placed at the top and sides of the beam forming a fan under the strips to achieve closed wrapping. The effect of these parameters on the failure modes, the ultimate load, and the beam stiffness were investigated. The shear contribution of FRP on the shear capacity of tested beams with web openings was estimated according to ACI Committee 440-08, Canadian Standards S6-06, and Khalifa et al. model and examined against the test results. A modification factor to account for the dimensions of opening chords was applied to the predicted gain in the shear capacity according to ACI 440-08 and CSA S6-06 for bonded Glass Fiber Reinforced Polymers (GFRP) around openings. The analytical results after incorporating the modification factor into the codes guidelines showed good agreement with the test results.

나선형 철근 및 섬유에 의하여 동시에 구속된 원형 콘크리트 실린더의 거동 (Behavior of Circular Concrete Cylinders Confined with Both Steel Spirals and Fiber Composites)

  • 이정윤;오영준;정훈식
    • 콘크리트학회논문집
    • /
    • 제16권2호
    • /
    • pp.175-184
    • /
    • 2004
  • 횡방향철근에 의하여 구속된 기존의 철근콘크리트 부재를 섬유에 의하여 보수$\cdot$보강할 경우에 그 부재는 철근과 섬유에 의하여 동시에 구속된다. 이렇게 두 가지 재료에 의하여 복합구속된 콘크리트의 거동은 구속재료의 응력-변형률 곡선 및 구속압에 따라서 달라진다. 이 논문에서는 나선형철근과 섬유에 의하여 동시에 구속된 24개의 실린더 실험을 통하여 복합재료에 의하여 구속된 콘크리트의 거동을 분석하였다. 실험에 의하면 복합재료에 의하여 구속된 콘크리트의 거동은 한 가지 재료만에 의하여 구속된 콘크리트의 거동과 큰 차이를 나타냈다.

FRP 선박 외판재의 연삭마모 특성에 관한 연구 (A study on abrasive wear characteristics of side plate of FRP ship)

  • 김병탁;고성위
    • 수산해양기술연구
    • /
    • 제44권3호
    • /
    • pp.250-256
    • /
    • 2008
  • Generally the side plate materials of FRP ship are composed of glass fiber and unsaturated polyester resin composites(GFRP composites). In this study, the effect of applied load and sliding speed on friction and wear characteristics of these materials were investigated at ambient temperature by pin-on-disc friction test. The cumulative wear volume, friction coefficient and wear rate of these materials for SiC abrasive paper were determined experimentally. The cumulative wear volume showed a tendency to increase nonlinearly with increase of sliding distance and was dependent on applied load and sliding speed for these composites. The friction coefficient of GFRP composites was increased as applied load increased at same sliding speed in wear test. It was verified by SEM photograph of worn surface that major failure mechanisms were microfracture, deformation of resin, cutting and cracking.

건설구조물에 적용된 섬유복합재료의 LCC 검토 (Life Cycle Cost Analysis on the Application of FRP in Construction Field)

  • 한복규;신관수;김기수;홍건호
    • Composites Research
    • /
    • 제19권5호
    • /
    • pp.34-39
    • /
    • 2006
  • The mechanical properties and durabilities of fiber advanced composites make them ideal for widespread applications in construction worldwide. However, one of the problems of fiber reinforced advanced composites has expensive initial costs. So the efforts for lowering the initial cost have to be needed. There has been hardly assessment results of life cycle cost for fiber reinforced advanced composites in construction field, but some papers showed that total life cycle cost could be profitable, if the initial cost could be reduced. The purpose of this paper is to report assessment results of LCC(Life Cycle Cost) for application of FRP(Fiber Reinforced Plastic) in construction field.

Bond strength characterization and estimation of steel fibre reinforced polymer - concrete composites

  • Jahangir, Hashem;Eidgahee, Danial Rezazadeh;Esfahani, Mohammad Reza
    • Steel and Composite Structures
    • /
    • 제44권6호
    • /
    • pp.803-816
    • /
    • 2022
  • Composite materials are effective in forming externally bonded reinforcements which find applications related to existing structures repair, attributed to their high strength-to-weight ratio and ease of installation. Among various composites, fibre reinforced polymers (FRP) have somewhat been largely accepted as a commonly utilized composite for such purposes. It is only recently that steel fibres have been considered as additional members of the FRP fibre family, intuitively termed as steel reinforced polymer (SRP). Owing to its low cost and permissibility of fibre bending at sharp corners, SRP is rapidly becoming a viable contender to other FRP systems. This paper investigates the bond behaviour of SRP-concrete joints with different bonded lengths (50, 75, 100, 150 and 300 mm) and widths (15, 30, 40, 50, and 75 mm) using single-lap shear tests. The experimental specimens contain SRP strips with a fixed density of steel fibres (0.472 cords/mm) bonded to the face of concrete prisms. The load responses were obtained and compared in terms of corresponding load and slip boundaries of the constant region and the peak loads. The failure modes of SRP composites are discussed, and the range of effective bonded length is evaluated herein. In the end, a new analytical model was proposed to estimate the SRP-concrete bond strength using a genetic algorithm, which outperforms 22 existing FRP-concrete bond strength models.