• Title/Summary/Keyword: FRP 판

Search Result 131, Processing Time 0.033 seconds

An Experimental Study on Static Behaviors of Composite Sandwich Bridge Decks with Hybrid GFRP-Steel Core (하이브리드 GFRP-강재 심재를 갖는 복합샌드위치 교량바닥판의 정적거동에 관한 실험 연구)

  • Ji, Hyo-Seon;Chun, Kyung-Sik;Park, Dae-Yong;Son, Byung-Jik
    • Journal of the Korean Society for Advanced Composite Structures
    • /
    • v.2 no.3
    • /
    • pp.12-17
    • /
    • 2011
  • This paper presents the flexural behavior of a hybrid Glass Fiber-Reinforced Polymer(GFRP)-steel decks for use in deteriorated bridge decks replacement. Static load tests were conducted to investigate the structural characteristics of the hybrid FRP-steel deck. The tested deck panel satisfied the design criteria. The failure mode of the hybrid deck was demonstrated ductility with deformation beyond initial yielding. The responses were compared with the ANSYS finite element predictions. It was found that the presented hybrid deck was efficient for use in bridges. The thickness of the hybrid deck may be decreased when compared to that of the all FRP deck with similar flexural rigidity.

Self Sensing Reinforcement Combined with Fiber-Optic Sensor and FRP Strip for Structural Reinforcement (구조물 보강용 FRP 판과 광섬유 센서가 결합된 자기감지 보강재)

  • Song, Se-Gi;Seo, Soo-Yeon;Kim, Kang Su
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.35 no.8
    • /
    • pp.123-130
    • /
    • 2019
  • Recently, it is required to develop a monitoring technology that combines an FBG sensor as a means for continuously monitoring whether reinforcing effect of FRP is maintained on FRP reinforced structural members. However, most existing researches focus on the insertion of FBG sensors into bar-shaped FRPs, and there is insufficient study on the details strip-type FRPs combined with FBG sensors. Therefore, in this paper, it is studied to develop a reinforcement in which a FBG sensor is combined with a FRP strip. Especially, combination of FRP and FBG sensor. For this, a series of experiments were performed to find the adhesive strength of fiber-FRP-epoxy joints, the tensile strength of FBG sensor part with reflection-lattice, and the performance depending on the connection method of FRF and FBG sensor. As a result of the study, it was found that a minimum strength of $216.15N/mm^2$ is required for incorporating FBG sensors in FRP using epoxy. It is considered that the adhesion length of epoxy joints should be more than 50mm. When the FBG sensor is attached to the FRP strip as an epoxy, it is considered appropriate to use the complete attachment and the sensor non-attachment method.

An Experinmental Study on Characteristic Analysis of Durability which follows in temperature for FRP Modular Box Member (온도변화에 따른 FRP 모듈형 박스 부재의 내구성 파악을 위한 실험적 연구)

  • Kwak, Kae-Hwan;Kim, Woo-Jong;Yang, Dong-Oun;Kim, Ho-Sun
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2009.04a
    • /
    • pp.251-254
    • /
    • 2009
  • 건설 분야에서 FRP(Fiber Reinforced Polymers) 부재는 기존의 건설부재에 비해 많은 장점을 가지고 있어 여러 분야에서 연구 및 개발이 이루어지고 있다. 그중 FRP 재료를 이용한 교량 부재들이 해외 뿐만 아니라 국내에서도 연구되고 있으며, FRP 인장재 및 바닥판은 연구 및 개발이 완료돼 현재 시공 중에 있고 FRP 휨 부재 또한 연구가 활발히 진행되고 있다. 이런 FRP 부재는 외부 환경에 그대로 노출됨으로써, 온도 등의 주위 환경의 변화에 많은 영향을 받게 되며, 특히 높은 온도에 취약한 성질을 가지고 있다. 이에 본 연구에서는 FRP 부재의 온도에 따른 역학적 특성을 파악하기위한 실험적 연구로써, $-21^{\circ}C$, $100^{\circ}C$, $200^{\circ}C$에 각각 1시간씩 시험체를 보관한 뒤 내구성 실험을 실시하였다. 각각의 시험체는 FRP 모듈형 박스부재에서 4개씩 채취하였으며, 실험 실시 후 SEM촬영을 실시하여 파괴모드를 분석하였다. 실험 결과 저온일 때는 강도변화가 많이 나타나지 않았으나 고온일 때 압축 및 휨강도의 급격한 저조를 확인할 수 있었다. 고온 보관 시험체의 SEM(Scanning Electron Microscope) 촬영결과 수지의 손상으로 낮은 강도가 측정되는 것을 확인할 수 있었다.

  • PDF

A Study on the Behavior Characteristics of a New-Type FRP-Concrete Composite Deck (신개념 FRP-콘크리트 합성 바닥판의 거동 특성 고찰)

  • Cho Keunhee;Chin Won Jong;Kim Sung Tae;Cho Jeong-Rae;Kim Byung-Suk
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2004.05a
    • /
    • pp.746-749
    • /
    • 2004
  • A new-type of FRP-concrete composite bridge deck system is proposed and its behaviors are experimentally studied. The new-typedeck consists of FRP as a permanent form and main tension resisting member and concrete as a compression resisting member. A suitable bonding method such as silica coating is applied to the interface between FRP and concrete to ensure composite behavior. The proposed deck system uses the box-shape FRP member, while a typical FRP-concrete composite deck uses the I-shape FRP member. Theproposed deck system has inherent advantages of a FRP-concrete composite deck like corrosion free and easy construction. The new-type deck shows the equal performances compared to a previous one, and has the advantage of reducing self-weight. In this study, the static tests on 3-span FRP-concrete decks in full scale are carried out, so that load-displacement relation, stress distribution, failure mode and design criteria are analyzed. The test results show that the deflection design criterion (L/800, L: span length) is satisfied at the service load state. No concrete tensile crack occurs in the negative moment region above the main girder, regardless of no tensile reinforcement at upper concrete portion.

  • PDF

Flexural Design of Externally Bonded FRP Systems for Strengthening Concrete Structures (섬유판보강공법에서 휨설계식에 대한 연구)

  • 서정국;임종범;최완철
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2002.10a
    • /
    • pp.463-468
    • /
    • 2002
  • For the Externally bonded FRP systems, flexural design method is studied focusing on the reinforcement layer of the carbon fiber sheets. As the FRP layer is added, strengthening rate increases, but not proportionally as the FRP layer increases. This is reflected in the design formula appropriately by the bond cofficients from the added layers. As the number of FRP layer increases, the stress reinforcement and FRP sheet decreases, and it generally corresponds to the decrease rate of member flexural strength. This phenomenon is appearing indentically in a design formula and experimental result. The rate of $M_{test}$ and $M_n$ is 1.19 and it is estimated as safety factor which is the reduction factor, ${\psi}_f = 0.85$.

  • PDF

Material property optimization of Pultruded FRP bridge deck section (인발성형 FRP 바닥판의 물성 최적화)

  • 최영민;조효남;이종순;김희성
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2004.04a
    • /
    • pp.135-142
    • /
    • 2004
  • The apparent advantages of FRP (fiber reinforced plastics) composites over the conventional structural materials may be attributed to their high specific strength and stiffness. Other affordable properties of FRPs including an excellent durability make them particularly attractive for the structures in severe service conditions. Therefore, the material and sectional properties of a FRP structural component should be designed to meet its specific requirements and service conditions. This paper is performed the material property optimization under optimum design of pultruded FRP bridge deck section. In the problem formulation, an objective function is selected to minimize the maximum R(strength ratio). The thickness of layers, volumes of fibers and matrix fiber orientation, and stacking sequence of FRPs are used as the design variables. Strength ratio in the design code, material failure criteria and pultruded manufacture thickness are selected as the design constraints to enhance the material performance of FRP decks. From the results of the numerical investigation, we obtained the optimum deck section profile for conventional using object.

  • PDF

The Study of Optimal Design of FRP-Concrete Composite Deck (FRP-콘크리트 합성 바닥판의 최적설계에 관한 연구)

  • 이현섭;조성배;박장호;신영석
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2004.10a
    • /
    • pp.511-516
    • /
    • 2004
  • The objective of this study is to optimally design FRP-concrete members of a bridge structure. Using the GENESIS7.0 that is a commercial optimization program we performed an optimal design with design parameters that consist of height, width of FRP member, height of concrete. And we practiced an optimal design with the design variables, thickness of upper flange, bottom flange, and web. The results of these studies are summarized as follows : (1) Thickness of composite-concrete is proper at over loon (2) FRP member reaches the optimal section when the width of the FRP member is 20cm its height is 10cm and the height of the composite-concrete is 12cm.

  • PDF

Performance Verification of FRP Decks by Connection between Bridge Rail and FRP Decks (방호울타리 연결방법에 의한 FRP바닥판의 거동특성)

  • Lee, Young-Ho;Jeong, Jin-Woo;Youm, Kwang-Soo;Park, Ki-Tae;Hwang, Yoon-Koog
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.05a
    • /
    • pp.134-137
    • /
    • 2006
  • In this paper, performance verification of connection between bridge rail and FRP decks are performed by static test. Also, the effect of flexible bridge rail failure to behavior of FRP deck are examined. Commercial products of flexible bridge rail are applied to test specimen, and 6 types of FRP deck-to-bridge rail connection system are considered. By the test results, 6 types of connection system by the connection method have similar structural capacity and have enough safety margin. Therefore, it is determined that 6 kinds of bridge rail considered in this study can be applied to bridge effectively by the cases of bridge field condition.

  • PDF

Evaluation of Flexural Strength of FRP-Concrete Composite Decks According to Details of Their Connecting Parts above Girders (연결부 상세에 따른 FRP-콘크리트 합성 바닥판의 거더 위 부모멘트부 휨강도 평가)

  • Park, Sung-Yong;Cho, Keun-Hee;Kim, Sung-Tae;Cho, Jeong-Rae;Kim, Byung-Suk
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.21-24
    • /
    • 2008
  • Tests were performed to obtain the flexural capacity of the innovative FRP-Concrete Composite Deck (FCCD) above girders. Test parameters were details of connection parts between FCCD and girder, such as continuity of FRP module, reinforcing ratio of FRP re-bars, and existence of shear connecting plate. As a test result, we found flexural strength of FCCD in the negative zone increases when FRP module is continuous, and reinforcement is increased, and shear connecting plate exists. And the flexural strength of all specimens give enough safety compared to the value needed in Korean highway bridge design code.

  • PDF

Study on Flexural Damage of FRP Laminates (FRP 적층판의 휨 손상에 관한 연구)

  • Park, Sung-Jin
    • Journal of Urban Science
    • /
    • v.6 no.2
    • /
    • pp.49-57
    • /
    • 2017
  • A new Fiber Bragg Grating (FBG) wavelength demodulation scheme is studied in the paper, which consists of an improved de-noising method and Gaussian fitting peak searching algorithm. The improved translational invariant wavelet without threshold adjust factor is proposed to get a better de-noising performance for FBG sensor signal and overcome the drawbacks of soft or hard threshold wavelets. In order to get a high wavelength demodulation precision of FBG sensor signal, this de-noising method is designed to combine with Gaussian fitting peak searching algorithm. The simulation results show that the wavelength maximum measurement error is lower than 1pm, and can get a much higher accuracy.

  • PDF