• Title/Summary/Keyword: FOOT FORCE

Search Result 339, Processing Time 0.033 seconds

Analgesia of Electroacupuncture and Radio-Frequency Warm Needling in Acupoint Combination on Ankle Sprain in Rats (발목염좌에 배혈에 따른 전침과 고주파온침의 진통효과)

  • Yang, Seung-Bum;Kim, Min-Su;Kim, Jae-Hyo
    • Korean Journal of Acupuncture
    • /
    • v.35 no.1
    • /
    • pp.27-35
    • /
    • 2018
  • Objectives : The purpose of this study was to investigate the analgesic effect of electroacupuncture(EA) and radio-frequency warm needling(RFWN) stimulation in acupoint combination on ankle sprained pain in rats. Methods : The lateral ligaments of the Sprague-Dawley rats ankle were injured surgically resulting in sprain, of which was divided into EA, RFWN treatment groups and control group without treatment. The level of pain was measured through foot weight bearing force ratio followed by calculating pain relief. To stimulate proximal or distal area in ankle sprain, combination of proximal acupoints(GB34-GB39) and distal acupoints(GB39-GB42) from sprain area were applied, respectively, to either EA or RFWN stimulation. In addition, naltrexone or phentolamine was injected intraperitoneally before the stimulation to observe the pathway of analgesic effects. Results : In the proximal combination of GB34-GB39, EA and RFWN significantly increased pain relief compared to the control group (p<0.05). However, in distal combination with GB39-GB42, both EA and RFWN stimulation did not relieve pain due to ankle sprains. In the combination of GB34-GB39, the analgesia of EA was inhibited by blockade of the ${\alpha}$-adrenoceptor receptor. The analgesia of RFWN was inhibited by blockade of the ${\alpha}$-adrenoceptor receptor as well as ${\mu}$-opioid receptor. Conclusions : We observed that the proximal combination was effective in relieving pain when the treatment by acupoint combination was applied to the ankle sprain pain. Also, it was confirmed that this analgesia was also related to the pathways of ${\mu}$-opioid receptors and/or ${\alpha}$-adrenoceptors.

Complexity Pattern of Center of Pressure between Genders via Increasing Running Speed (달리기 속도 증가에 따른 성별 CoP (Center of Pressure)의 복잡성 패턴)

  • Ryu, Jiseon
    • Korean Journal of Applied Biomechanics
    • /
    • v.29 no.4
    • /
    • pp.247-254
    • /
    • 2019
  • Objective: The goal of this study was to determine the center of pressure (CoP) complexity pattern in approximate entropy technique between genders at different conditions of running speed. Background: It is conducted to evaluate the complexity pattern of CoP in the increment of running speed to have insights to injury prediction, stability, and auxiliary aids for the foot. Method: Twenty men (age=22.3±1.5 yrs.; height=176.4±5.4 cm; body weight=73.9±8.2 kg) and Twenty women (age=20.8±1.2 yrs.; height=162.8±5.2 cm; body weight=55.0±6.3 kg) with heel strike pattern were recruited for the study. While they were running at 2.22, 3.33, 4.44 m/s speed on a treadmill (instrumented dual belt treadmills, USA) with a force plate, CoP data were collected for the 10 strides. The complexity pattern of the CoP was analyzed using the ApEn technique. Results: The ApEn of the medial-lateral and antero-posterior CoP in the increment of running speed showed significantly difference within genders (p<.05), but there were not statistically significant between genders at all conditions of running speed. Conclusion: Based on the results of this study, CoP complexity pattern in the increment of running speed was limited to be characterized between genders as an indicator to judge the potential injury and stability. Application: In future studies, it is needed to investigate the cause of change for complexity of CoP at various running speed related to this study.

Taekwondo Demonstrations Seen in the Perspective of Open Demonstrations: Focusing on the period from the emancipation until the 1960's (공시적 관점에서 본 태권도시범 : 광복이후부터 1960년대)

  • Na, Chae-Man;Lee, Young-Hoon
    • The Journal of the Convergence on Culture Technology
    • /
    • v.4 no.1
    • /
    • pp.263-273
    • /
    • 2018
  • This study is based on literature review intended to understand how Taekwondo demonstrations have been made from the emancipation until the 1960's in the perspective of open demonstrations. The findings of this study are summed up as follows. First, Taekwondo demonstrations were influenced significantly by social situations like the emancipation and emergence of gigan studios, dispatching ROK armed forces to the Vietnam War, or the foundation of International Taekwondo Federation(ITF). Second, in terms of forms, Taekwondo demonstrations were made as a form of demonstrating martial arts that had been improved in each of the studios when there was an examination for promotion, the studio needed publicity, or they wanted to show how individuals' skills had been cultivated. In terms of contents, with basic skills of Taekwondo as the ground, they dealt with forceful hand/foot breaking, simple jumping up and breaking, sparring, and practical self-defense martial arts, and so on.

A Study on the Measurement of Electric Resistance of Footwear (신발의 전기저항 측정에 관한 연구)

  • Choi, Sang-Won;Lee, Seokwon
    • Journal of the Korean Society of Safety
    • /
    • v.28 no.3
    • /
    • pp.56-62
    • /
    • 2013
  • The occurrence of the ventricular fibrillation is directly dependent on the magnitude and duration of the current. The current which flows through the human body is proportional to the touch voltage applied across the body and is in inverse proportion to the impedances in the circuit. The circuit impedances consist of human body impedance, line impedance, equipment impedance, earth terminal impedance and impedance of shoes which a person put on. The impedance of shoes greatly affect the severity of the electric accidents. The human body impedances relevant to the contact areas, contact conditions, current paths and touch voltages are already determined in the IEC 60479-1. However, the impedance of shoes is ignored or substituted by a simple value because of the absence of the sufficient data. For example, the impedance of shoes plus ground contact resistance is postulated to be $1,000{\Omega}$ in the IEC 61200-612. In IEEE 80, the shoe resistance plus ground contact resistance is assumed to be bare foot with ${\rho}/4b{\Omega}$. In this paper, we measured and analyzed the impedance of shoes with respect to conditions such as applied weight, environment variables and voltages. The results showed that the impedance of shoes is dependent on environment variables regardless of the types of shoes. Most of shoes showed the correlation with the applied force, whereas a few shoes showed characteristics related to the applied voltage. In terms of severity of electric shock, one thirds of test samples indicated to be dangerous in saltwater conditions.

Effects of High Frequency Warm Needling of LI4 Acupoint on the Carrageenan-induced Arthritis in Rats (합곡(合谷)(LI4)의 고주파 온침 자극이 흰쥐의 족과(足踝) 관절염(關節炎)에 미치는 효과)

  • Park, Sang-Yeon;Kwon, Oh-Sang;Choi, Won-Jong;Kim, Jae-Hyo;Kim, Kyung-Sik;Sohn, In-Chul;Ahn, Seong-Hun
    • Korean Journal of Acupuncture
    • /
    • v.26 no.2
    • /
    • pp.61-74
    • /
    • 2009
  • Objectives: The warm needling technique is a method which combines the effects of acupuncture with those of moxibustion. The purpose of this study was to find the stimulus effects of a high frequency warm needling device when stimulating acupoint $LI_4$ on the carrageenan-induced arthritis. Methods: This study was to observe the effects to edema reaction, WBF(weight bearing force), NO concentration, nNOS expression after the electro high frequency stimulus of high frequency warm needling device on LI4 with insulated acupuncture needle. Results: The effect of the high frequency warm needling device is to rise up the temperature in proportion to the current intensity. After stimulating on the acupoint $LI_4$ of the carrageenan-induced arthritis in rats with the high frequency warm needling device, it significantly reduced edema in the rat's foot. In addition, WBF, NO concentration of spinal cord (nmol/mg), and nNOS relative expression were reduced. Conclusions: The above results support the idea that stimulus by the high frequency warm needling device on $LI_4$ produces a potent analgesic effect in the arthritis pain model of the rat. Moreover, stimulus by the high frequency warm needling device modulates endogenous NO through the suppression of nNOS protein expression.

  • PDF

ICT Fusion Type Plasma Access Control System for Disease Prevention and Sterilization and Disinfection (질병예방 및 살균·소독을 위한 ICT 융복합형 플라즈마 출입관리 시스템)

  • Kim, Eung-Kon;Kim, Jin-Ha
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.13 no.6
    • /
    • pp.1417-1424
    • /
    • 2018
  • The damage caused by foot-and-mouth disease and AI has been repeated in year by year, and the actual damage is held by farmers. Currently, domestic livestock farmers' demand for foreign labor force is rapidly increasing, but the foreign management system is very inadequate, autonomous disinfection consciousness is poor and seasonally disinfest of winter is a serious situation. Thus, the exit management system, where small and medium scale farmers can purchase and install, is necessary for medium and small scaled farmer who is suffering from the pollutants and who does not have capacity to install expensive sterilization. In this paper, we propose ICT fusion combined plasma access control system which can utilize the principle of low temperature plasma lamp, to introduce disinfection system, to ensure convenience and safety that enables integrated control.

Effect of Step Height and Visual Feedback on the Lower Limb Kinematics Before and After Landing

  • Jangwhon Yoon
    • Physical Therapy Korea
    • /
    • v.31 no.1
    • /
    • pp.29-39
    • /
    • 2024
  • Background: Landing from a step or stairs is a basic motor skill but high incidence of lateral ankle sprain has been reported during landing with inverted foot. Objects: This study aimed to investigate the effect of landing height and visual feedback on the kinematics of landing and supporting lower limbs before and after the touch down and the ground reaction force(GRF)s. Methods: Eighteen healthy females were voluntarily participated in landing from the lower (20 cm) and the higher (40 cm) steps with and without visual feedback. To minimize the time to plan the movement, the landing side was randomly announced as a starting signal. Effects of the step height, the visual feedback, or the interaction on the landing duration, the kinematic variables and the GRFs at each landing event point were analyzed. Results: With eyes blindfolded, the knee flexion and ankle dorsiflexion on landing side significantly decreased before and after the touch down. However, there was no significant effect of landing height on the anticipatory kinematics on the landing side. After the touch down, the landings from the higher step increased the knee flexion and ankle dorsiflexion on both landing and supporting sides. From the higher steps, the vertical GRF, anterior GRF, and lateral GRF increased. No interaction between step height and visual feedback was significant. Conclusion: Step height and visual feedback affected the landing limb kinematics independently. Visual feedback affected on the landing side while step height altered the supporting side prior to the touch down. After the touch down, the step height had greater influence on the lower limb kinematics and the GRFs than the visual feedback. Findings of this study can contribute to understanding of the injury mechanisms and preventing the lateral ankle sprain.

Effect of light touch on body sway during a stable posture with blocked visual information

  • Kim, Jong-Gun;Kim, Jin-Hong;Do, Kwang-Sun;Yim, Jongeun
    • Physical Therapy Rehabilitation Science
    • /
    • v.5 no.3
    • /
    • pp.138-142
    • /
    • 2016
  • Objective: The purpose of this study was to investigate how light touch with a finger affects balance ability when a posture is maintained in the condition of visual information blockage and to provide a fundamental material for developing balance ability in the process of rehabilitation treatment. Design: Cross-sectional study. Methods: The study subjects were 17 healthy men and women in their twenties and thirties who were studying at S University in Seoul. The system was comprised of an equilateral triangular force platform. Subjects were asked to step on the foot position of the force platform (Good Balance, Finland) barefooted for 30 seconds, with eyes closed, hands hanging down loosely, and feet comfortably apart. It was connected to a laptop by using Bluetooth technology. An experiment was conducted in the following three circumstances: 1) no-touch trial, 2) light touch to the back (T7 area), and 3) light touch to the middle finger of the left hand. Each subject was given a 10-minute break between consecutive measurements. The experimental circumstances were performed randomly. Anteroposterior sway (APSV), mediolateral sway velocity (MLSV), and velocity moment (VM) were measured. Results: The APSVs (mm/s) were $9.32{\pm}3.37$ and $5.45{\pm}2.98$; the MLSVs (mm/s), $6.39{\pm}3.35$ and $3.31{\pm}2.48$; and VM ($mm^2/s$), $17.13{\pm}11.75$ and $6.76{\pm}8.31$ in the first and second experimental circumstances, respectively. APSV, MLSV, and VM values were significantly improved with the 1) no-touch trial and 2) light touch to the back trail conditions compared with the 3) light touch to the middle finger of the left hand condition (p<0.05). Conclusions: This study revealed that the balance ability for maintaining a body posture was influenced more by light touch to the back (T7) than by light touch with the sensitive fingertip and body sway diminished after visual information was blocked.

Gait Phases Detection from EMG and FSR Signals in Walkingamong Children (근전도와 저항 센서를 이용한 보행 단계 감지)

  • Jang, Eun-Hye;Chi, Su-Young;Lee, Jae-Yeon;Cho, Young-Jo;Chun, Byung-Tae
    • Science of Emotion and Sensibility
    • /
    • v.13 no.1
    • /
    • pp.207-214
    • /
    • 2010
  • The aim of this study was to investigate upper and lower limb muscle activity using EMG(electromyogram) sensors while walking and identify normal gait pattern using FSR(force sensing resistor) sensor. Fifteen college students participated in this study and their EMG and FSR signal were measured during stopping and walking trials. EMG signals from upper(pectoralis major and trapezius) and lower limbs(rectus femoris, biceps femoris, vastus medialis, vastus lateralis, semimembranosus, semitendinosus, soleus, peroneus longus, gastrocnemius medialis, and gastrocnemius lateralis) were obtained using the surface electrodes. FSR measured pressures on 8 areas of the sole of the foot during walking. EMG results showed that all muscle activities except for vastus lateralis and semimembranosus during walking had higher amplitudes than stopping. Additionally, muscle activities associated with stance and swing phase during walking were identified. Results on FSR showed that stance and swing phases were detected by FSR signals during a gait cycle. Eight gait phases-initial contact, loading response, mid stance, terminal stance, pre swing, initial swing, mid swing, and terminal swing- were classified.

  • PDF

The Scientific Analysis of Aged' Shoe for Health Promotion (노인 건강증진용 신발의 운동과학적 효과분석)

  • Jin, Young-Wan;Kwak, Yi-Sub
    • Journal of Life Science
    • /
    • v.21 no.9
    • /
    • pp.1336-1345
    • /
    • 2011
  • The purpose of this study was to analyze and compare the effects of exercise science of shoes for Aged' health promotion. Kinematic and kinetic data were collected using cinematography and the Zebris system (Zebris Emed Sensor Platform, GR-DVL9800) to analyze pressure of foot and ground reaction force. Subjects recruited were 20 healthy elderly men. They walked at 1.36m/sec velocity wearing type A (domestic), type B (foreign) and walking shoes (A company). One-way ANOVA was used to analyze statistics. The results were as following: no significant differences were observed in gait variables among the three groups (p<0.05). There was a significant difference in max pronation angle of heels examined among the three groups (p<0.05). There were no significant differences in kinetic variables (ground reaction force and max pressure) among the three groups (p<0.05). A physiology study was performed to analyze the effects of walking with shoes with silver added to them on percent body fat, resting metabolic rate and energy expenditure. Sixty adults males were recruited from the public health center. They were divided into four groups. C: control group (n=20), EY: elderly Y group (n=20), and EO: elderly O group (n=20). The results of this study were as follows: percent body fat was decreased following each exercise period, however, not all the groups showed a significant difference. The change of resting metabolic rate was significantly increased in HI (high intensity) and LI (low intensity) periods in the C and EY groups. However, there was no significant difference in the EO group. The mean energy expenditure during and after exercise were significantly lowered in all periods compared to the control group.