• Title/Summary/Keyword: FLOW-3D 수치실험

Search Result 201, Processing Time 0.026 seconds

A Study of Blasting Demolition by Scaled Model Test and PEC2D Analysis (축소모형실험 및 PFC2D해석에 따른 발파해체 거동분석)

  • 채희문;전석원
    • Tunnel and Underground Space
    • /
    • v.14 no.1
    • /
    • pp.54-68
    • /
    • 2004
  • In this study, scaled model tests were performed on blasting demolition of reinforced concrete structures and the experimental results were analyzed in comparison with the results of numerical analysis. The tests were designed to induce a progressive collapse, and physical properties of the scaled model were determined using scale factors obtained ken dimension analysis. The scaled model structure was made of a mixture of plaster, sand and water at the ratio determined to yield the best scaled-down strength. Lead wire was used as a substitute for reinforcing bars. The scaled length was at the ratio of 1/10. Selecting the material and scaled factors was aimed at obtaining appropriately scaled-down strength. PFC2D (Particle Flow Code 2-Dimension) employing DEM (Distinct Element Method) was used for the numerical analysis. Blasting demolition of scaled 3-D plain concrete laymen structure was filmed and compared to results of numerical simulation. Despite the limits of 2-D simulation the resulting demolition behaviors were similar to each other. Based on the above experimental results in combination with bending test results of RC beam, numerical analysis was carried out to determine the blasting sequence and delay times. Scaled model test of RC structure resulted in remarkably similar collapse with the numerical results up to 900㎳ (mili-second).

Analysis of vortex generation tendency around the pump suction using three dimentional numerical model (3차원 수치모형을 이용한 펌프 흡입부 주변의 와류 발생 경향 분석)

  • Byun, Hyun Hyuk;Yang, Jae Hoon;Yoon, Byung Man
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2016.05a
    • /
    • pp.103-103
    • /
    • 2016
  • 최근 기후변화에 따른 집중호우로 도시홍수의 피해가 급격히 증가하고 있다. 특히 인구가 밀집하고 교통량이 많은 대도시의 경우 동일한 호우에 대하여 녹지나 농경지 등에 비해 그 피해가 더 심각하다. 일반적으로 홍수 피해의 직접원인은 외수로 인한 피해와 내수로 인한 피해로 크게 구분할 수 있다. 외수피해는 주로 소하천 및 지천의 범람, 제방의 붕괴 등으로 발생한 것이며 내수피해는 배수로, 하수도 및 펌프장의 내수배제능력 부족이 주된 원인이다. 따라서 도시홍수를 효과적으로 방어하기 위해서는 우선적으로 내배수시설의 성능개선이 선행되어야 할 필요가 있다. 이러한 내배수 시설의 성능 개선을 위해서는 현재 기 설치되어 있는 빗물펌프장의 설계 및 내배수 효율에 대한 성능평가가 필요하다. 하지만 현재 국내 펌프설계기준에는 빗물펌프장의 설계 및 운영에 대한 구체적인 성능 평가 방법이 제시되어 있지 않은 실정이다. 만약, 펌프 흡입수조 및 흡입파이프의 형상이 적절하게 설계되지 못한다면 물이 파이프 입구로 부드럽게 흡입되지 못하고 볼텍스 및 스월이 발생하게 된다. 이러한 볼텍스 및 스월은 펌프 입구 쪽으로 물 뿐 아니라 공기를 함께 흡입시킴으로써 펌프의 효율저하, 소음, 진동을 발생시키며 펌프 파손의 원인이 될 수 있다. 따라서 펌프를 설치하기 전 펌프 설치 후에 발생되는 펌프 흡입부 주변의 흐름특성 변화 및 흐름특성이 구조물에 미치는 영향 등을 고려하기 위하여 수리모형실험이 필요한데, 수리모형실험은 많은 시간과 비용이 들어가기 때문에 이를 대체할 수 있는 방안이 요구된다. 그런 이유로 최근에는 수리모형실험 대신 수치모의를 이용하는 경우가 많다. 수치모의의 결과는 수리실험의 결과와 비교, 검증을 거쳐 신뢰성을 얻는다. 본 연구에서는, 3차원 수치모형의 다양한 난류모델을 이용하여 흡입파이프로 물이 유입될 때 흡입부 내, 외의 수심 별 유속 변화를 분석하고, 그 결과를 이용하여 FLOW 3D 모형의 검증을 수행하였다.

  • PDF

Three-dimensional Numerical Analysis of Dam-break Waves on a Fixed and Movable Bed (고정상 및 이동상 수로에서 댐 붕괴파의 3차원 수치해석)

  • Kim, Dae Geun;Hwang, Gun
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.31 no.4B
    • /
    • pp.333-341
    • /
    • 2011
  • This study analyzed the propagation of dam-break waves in an area directly downstream of a dam by using 3D numerical modeling with RANS as the governing equation. In this area, the flow of the waves has three dimensional characteristics due to the instantaneous dam break. In particular, the dam-break flows are characterized by a highly unsteady and discontinuous flow, a mixture of the sharp flood waves and their reflected waves, a mixture of subcritical and supercritical flow, and propagation in a dry and movable bed. 2D numerical modeling, in which the governing equation is the shallow water equation, was regarded as restricted in terms of dealing with the sharp fluctuation of the water level at the dam-breaking point and water level vibration at the reservoir. However, in this 30 analysis of flood wave propagation due to partial dam breaking and dam-break in channels with $90^{\circ}$ bend, those phenomena were properly simulated. In addition, the flood wave and bed profiles in a movable bed with a flat/upward/downward bed step, which represents channel aggradation or degradation, was also successfully simulated.

Numerical Experimentation of a 2-D B-Spline Higher Order Panel Method (2차원 B-스플라인 기저 고차패널법의 수치실험)

  • Chung-Ho Cho;Chang-Sup Lee
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.37 no.3
    • /
    • pp.27-36
    • /
    • 2000
  • A higher order panel method based on B-spline representation for both the geometry and the velocity potential is developed for the solution of the flow around two-dimensional lifting bodies. Unlike Lee/Kerwin, who placed multiple control points on each panel and solved the overdetermined system of equation by the least square approach, the present method places only as many number of control points as required by the unknowns of the problem. Especially, a null pressure jump Kutta condition at the trailing edge is found to be effective in stabilizing the solution process and in predicting the correct solution. The new approach, is validated to be accurate through comparison with the analytic solution for a 2-D airfoil and to be less time-consuming due to fewer number of panels required than that used in Lee/Kerwin.

  • PDF

Estimation of Hydraulic Effects Inside of Riverbank with Experimental Information Modeling (EIM을 이용한 제외지 수리모형 내 수리영향 분석)

  • Oh, Hee-Chang;Kim, Soo-Young;Joo, Sung-Sik;Lee, Seung-Oh
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2011.05a
    • /
    • pp.147-147
    • /
    • 2011
  • 이상기후 및 극한 홍수 발생빈도의 증가 등으로 인해 많은 수공 구조물이 붕괴 위험에 노출되어 있다. 사전 피해 예방 및 경감을 위해 다양한 수공구조물의 붕괴 현상에 대하여 수리실험적 접근방법을 통한 현상이해 및 예상결과 비교 검증이 필요하다. 그 중에서 제방붕괴에 대한 수리실험은 수치모의를 통한 분석의 어려움 때문에 대부분 모형실험을 통해서 이루어지고 있는 실정이다. 본 연구에서는 실제규모의 제방붕괴 선행실험의 측정결과를 활용하여 실험설계에 이용 하였다. 모형은 실험공간의 규모를 고려하여 축척을 1:10 으로하고, 하도내 흐름 안정을 위해 수로의 길이 는 16, 저폭은 $b\geq10h$를 만족하는 하천으로 설계하여 b를 3m로 설정 하였다. Fr수는 0.29로 원형과 동일하게 하고, 그에 따른 유량 ( )는 0.538m/s로 하였다. 실제 모형 제작에서는 현장 실험실의 펌프용량에 따른 가용유량 ($Q__{max}$)의 제약에 따라 수로가 직선이고 좌우가 대칭인 점을 감안하여 폭을 1/2로 절단 하고 유량은 $0.269m^3/s$(Q/2)를 공급하였다. 위와 같이 모형제작을 위한 실험 설계시 현장 여건을 고려하여 모형을 변형할 경우 EIM(Experimental Information Modeling)을 이용한 수리영향에 대한 분석을 통한 설계검증이 필요하다. FLOW-3D를 이용한 3차원 수치모의를 통하여 동일 지점에서의 유속과 수심을 분석하여 흐름양상을 비교 하였으며, 유속과 수심의 측정위치는 그림 1에 도시하였다. 수치모의 결과 측정지점에서의 수위가 하도 바닥을 기준으로 0.25m로 동일할 경우 수로 단면에 대한 유속 분포가 제방을 기준으로 2b/3까지는 유사한 경향을 보였다. 그 결과, $b\geq10h$인 수로에서 제방붕괴를 위한 모형 설계시 하도 폭을 1/2만 만들 경우에도 실험의 신뢰성이 확보된다는 것을 확인하였다.

  • PDF

Study on Current and Water Quality Characteristics in Yongil Bay (영일만내의 유동과 수질특성에 관한 연구)

  • 김헌덕;김종인;류청로
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2000.10a
    • /
    • pp.246-252
    • /
    • 2000
  • The water quality in Yeongil Bay is getting worse due to the sewage and the waste water from the surrounding industrial complex The study aims to simulate the current system that is necessary to built ecosystem model for the optium water quality control and clarify the correlation of current system characteristics with water quality in Yongil Bay. To clarify the characteristics of coastal water movement system and verify the applicability of the 3-D model, the current system was simulated using 3-D baroclinic model considered tidal current and density effects. As the results of numerical experiments, it is proved the 3-D model is the most appliable on the Yongil Bay where current flows slowly and the flow direction is varied by depths. From the results of simulation considered tidal current only, It am be clearly said the water in Yongil Bay flows in through the surface layer and flows out through the bottom layer. And the fresh water from the Hyongsan river and the heated discharge from POSCO have little effect on the current structure in Yonggil Bay, but have and important effect upon the density structure by diffusion of heat and salt. And the water quality distribution is closely related with the current structure characteristics as well as the tidal residual current system.

  • PDF

Experimental and Numerical Study on the Air-assist Atomizer Spray Droplets (2유체 분무 액적의 거동에 관한 실험 및 수치 해석적 연구)

  • Kim, D.I.;Oh, S.H.
    • Journal of ILASS-Korea
    • /
    • v.3 no.4
    • /
    • pp.65-76
    • /
    • 1998
  • An experimental and numerical study of a spray flow is performed to investigate the spray characteristics using an air-assisted atomizer. A Partical Dynamic Analyzer(PDA) is used to measure SMD, dmp velocity, and drop number density whose the initial conditions have considerable effect on the numerical results. The measured experimental data have been used to asses the accuracy of model predictions. Numerical investigation is made with the Eulerian - Lagrangian formulism. Turbulent dispersion effects using a Monte-Carlo method, turbulent modulation effect and entrainment of air are also numerically simulated. Results show that the numerical predictions of SSF(Stochastic Separated Flow) analysis yielded reasonable agreement with the experimental data. However, the model calculations for small drops produced the inconsistent numerical results due to the effect of surrounding air entrainment.

  • PDF

Experimental and Computational Studies for Flow Distribution In a Rectangular Duct System with Two Branches (두 개의 분지관을 가진 직사각형 덕트 내의 유량배분에 관한 실험 및 수치계산 연구)

  • 윤영환;배택희;박원구
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.9
    • /
    • pp.766-773
    • /
    • 2002
  • Flow distributions in a rectangular duct with two branch ducts are measured by 5 W laser doppler velocity meter. The fluid flows are also computed by commercial soft-ware of STAR-CD for comparison between them. The Reynolds numbers in the main duct are from 4,226 to 17,491. The ratios distributed into two branches from the main duct are in-variant to Reynolds numbers according to both of numerical and experimental results. However computed velocity profiles at exit of each branch are somewhat different from measured profiles at the same location.

Experimental and Numerical Study on the Performance Characteristics of an Open Channel Type Regenerative Pump (개수로형 재생펌프의 성능특성에 관한 실험적 및 수치해석적 연구)

  • Shin, Dong-Yun;Choi, Chang-Ho;Hong, Soon-Sam;Kim, Jin-Han
    • The KSFM Journal of Fluid Machinery
    • /
    • v.11 no.5
    • /
    • pp.7-14
    • /
    • 2008
  • Open channel type regenerative pump has been used in various industrial fields. It generates high pressure with low flow rate. However, it has low efficiency because of its complex flow pattern, We studied performance experiments and 3D numerical flow analysis of a regenerative pump. Through the numerical analysis, we could get the internal flow pattern and profile of a regenerative pump. Also, we examined leakage flow effects due to the gap between casing and impeller and stripper clearance. For the numerical analysis verification, we performed experiments and they had similar tendency at the design point.

Feasibility Calculation of FaSTMECH for 2D Velocity Distribution Simulation in Meandering Channel (사행하천의 2차원 유속분포 모의를 위한 FaSTMECH 모형의 적용성 검토)

  • Son, Geunsoo;You, Hojun;Kim, Dongsu
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.34 no.6
    • /
    • pp.1753-1764
    • /
    • 2014
  • Numerical flow simulation models in the riverine environments have been widely utilized for analyzing flow dynamics in various degrees in researches and practical applications. However, most of the simulated results have been validated based on the data from indoor experimental models or very limited in-situ measurements. Therefore, it has been required to more accurately validate the performance of the numerical models in terms of the detailed field observations. In particular, it was also hard to validate the performances of the existing numerical models in the real meandered river channels that encompass more sophisticated flow and geometric structures. Recently, advancements of the modern flow measuring instrumentations such as acoustic Doppler current profilers (ADCPs) enabled us to efficiently acquire the detailed flow field in the broad range of river channels, thus that it became to be possible to accurately validate any numerical models with the field observations. In this study, based on the detailed flow measurements in a actual meandered river channel using ADCP, we validated FaSTMECH model in iRIC in terms of water surface elevation, which is relatively new but began to get highlighted in the research areas. As the validation site, a meandering channel in River Experiment Center of KICT was chosen, which has 6.5 m of width, 0.38m of flow depth, 1.54 m3/s of flow discharge, 0.61 m/s of mean flow velocity, and 1.2 of sinuosity. As results, whereas the FaSTMECH precisely simulated water surface elevation, simulated velocity field in the bend did not match well with ADCP dataset.