• 제목/요약/키워드: FEA Simulation

검색결과 222건 처리시간 0.031초

물 순환 시스템용 BLDCM의 센서리스 제어 방식에 따른 출력 특성 비교 (Output Characteristic Comparison of BLDC Motor for Water Circulation System According to Sensorless Control Methods)

  • 김성안;조윤현
    • 전기학회논문지
    • /
    • 제66권9호
    • /
    • pp.1325-1333
    • /
    • 2017
  • The sensorless control of blushless DC motor(BLDCM) is based on the $120^{\circ}$ control in which the back electromotive force(Back EMF) for estimating the position of the rotor can be detected. However, the $120^{\circ}$ control has a disadvantage that the torque constant is small as compared with $180^{\circ}$ control which can not detect the back EMF. The $150^{\circ}$ control which complements these problems makes it possible to detect the back EMF and improve the torque constant by 12.5% compared to the $120^{\circ}$ control. Therefore, this paper compares the output characteristics of BLDCM through finite element method analysis (FEA) by the conventional and proposed control methods of BLDCM for water circulation system and proposes design for downsizing and weight reduction of BLDCM according to secured torque constant. The validity of the proposed control and design proposal is proved through simulation and experimental results by comparing the output characteristics of $120^{\circ}$ control and $150^{\circ}$ control.

구조해석을 통한 보조발전기 경량화에 관한 연구 (A Study on the Light Weighting of APU through Structural Analysis)

  • 김혜은;김진훈;노상완;김병호;백현무
    • 품질경영학회지
    • /
    • 제47권4호
    • /
    • pp.895-910
    • /
    • 2019
  • Purpose: The purpose of this study is to lighten the APU (Auxiliary Power Unit) structure of the KAAV (Korea Assault Amphibious Vehicle) through structural analysis. Methods: Commercially-available program (MIDAS.NFX) was used for finite element analysis. Frequency response analysis was performed through linear static and mode analyses to verify the structural stability according to the change of the structural materials. Results: Numerical simulation (linear static, mode and frequency response analyses) results showed that the safety factor of the APU was over 1.5 even under the worst case conditions. The APU made by aluminum structures was expected to be available in the military field, since every requirements in the KDS (Korean Defense Specifications) was fulfilled during the various tests and evaluations. Conclusion: The structural analysis was verified that the structural stability of the APU structure of the KAAV after change of the structural material.

A Fault Diagnostic Method for Position Sensor of Switched Reluctance Wind Generator

  • Wang, Chao;Liu, Xiao;Liu, Hui;Chen, Zhe
    • Journal of Electrical Engineering and Technology
    • /
    • 제11권1호
    • /
    • pp.29-37
    • /
    • 2016
  • Fast and accurate fault diagnosis of the position sensor is of great significance to ensure the reliability as well as sensor fault tolerant operation of the Switched Reluctance Wind Generator (SRWG). This paper presents a fault diagnostic scheme for a SRWG based on the residual between the estimated rotor position and the actual output of the position sensor. Extreme Learning Machine (ELM), which could build a nonlinear mapping among flux linkage, current and rotor position, is utilized to design an assembled estimator for the rotor position detection. The data for building the ELM based assembled position estimator is derived from the magnetization curves which are obtained from Finite Element Analysis (FEA) of an SRWG with the structure of 8 stator poles and 6 rotor poles. The effectiveness and accuracy of the proposed fault diagnosis method are verified by simulation at various operating conditions. The results provide a feasible theoretical and technical basis for the effective condition monitoring and predictive maintenance of SRWG.

High Speed Segmental Stator Type 4/3 SRM: Design, Analysis, and Experimental Verification

  • Hieu, Pham Trung;Lee, Dong-Hee;Ahn, Jin-Woo
    • Journal of Electrical Engineering and Technology
    • /
    • 제12권5호
    • /
    • pp.1864-1871
    • /
    • 2017
  • This paper presents a design of a 2-phase segmental stator type 4/3 switched reluctance motor (SRM) for air-blower application. The air-blower requires only one direction rotation, high rotor speed without torque dead-zone. In order to satisfy the requirements of the load, the rotor of the 4/3 proposed SRM is designed with wider rotor pole arc and non-uniform air-gap is applied on the rotor shape. With a special rotor structure, the motor generates a wider positive torque region and has no torque dead-zone. The stator of the proposed SRM is constructed with two segmental C-cores, and there are no magnetic connections between 2 C-cores. The flux follows in a short closed loop in each C-core and has no reversal flux in the stator. The static and dynamic characteristics of the proposed motor are analyzed by the finite element method (FEA) and Matlab-Simulink, respectively. In order to verify the design, a prototype of the proposed motor has manufactured for laboratory test. The performance of the proposed motor is verified by the simulation and experimental results.

Bio-inspired leaf stent for direct treatment of cerebral aneurysms: design and finite element analysis

  • Zhou, Xiang;You, Zhong;Byrne, James M.D.
    • Smart Structures and Systems
    • /
    • 제8권1호
    • /
    • pp.1-15
    • /
    • 2011
  • Cerebral aneurysm is common lesion among adult population. Current methods for treating the disease have several limitations. Inspired by fern leaves, we have developed a new stent, called leaf stent, which can provide a tailored coverage at the neck of an aneurysm and thus prevent the blood from entering the aneurysm. It alone can be used to treat the cerebral aneurysm and therefore overcomes problems existing in current treating methods. The paper focuses on the numerical simulation of the leaf stents. The mechanical behaviour of the stent in various designs has been investigated using the finite element method. It has been found that certain designs provide adequate radial force and have excellent longitudinal flexibility. The performance of certain leaf stents is comparable and even superior to those of the commercially available cerebral stents such as the Neuroform stent and the Enterprise stent, commonly used for stent assisted coiling, while at the same time, providing sufficient coverage to isolate the aneurysm without using coils.

궤간 가변 윤축의 잠금부품들에 대한 구조해석 (Structural Analysis of Locking Parts in the Gauge -Adjustable Wheelset)

  • 김철수;장천수;장승호;김정규
    • 한국철도학회논문집
    • /
    • 제11권1호
    • /
    • pp.33-38
    • /
    • 2008
  • 이종궤간(협궤/표준궤/광궤)이 존재하는 유라시아 철도네트워크(TCR 및 TSR 등)의 운송시간 및 비용을 절감하기 위하여, 이 구간을 자유롭게 운행할 수 있는 궤간 가변 장치의 개발이 중요하다. 따라서 궤간가변차량의 안전성을 확보하기 위하여 각 시스템 및 부품들의 구조해석을 통한 건전성을 평가하는 것이 필요하다. 본 연구에서는 개발중인 궤간가변 윤축시스템의 안정성 검토의 연구의 일환으로서, 궤간 변환구간 및 곡선부 주행시 차륜의 횡압하에 잠금부품들 사이의 접촉응력을 유한요소해석 시뮬레이터를 이용하여 평가하였다.

플립칩의 매개변수 변화에 따른 보드레벨의 동적신뢰성평가 (Dynamic Reliability of Board Level by Changing the Design Parameters of Flip Chips)

  • 김성걸;임은모
    • 한국생산제조학회지
    • /
    • 제20권5호
    • /
    • pp.559-563
    • /
    • 2011
  • Drop impact reliability assessment of solder joints on the flip chip is one of the critical issues for micro system packaging. Our previous researches have been showing that new solder ball compositions of Sn-3.0Ag-0.5Cu has better mechanical reliability than Sn-1.0Ag-0.5Cu. In this paper, dynamic reliability analysis using Finite Element Analysis (FEA) is carried out to assess the factors affecting flip chip in drop simulation. The design parameters are size and thickness of chip, and size, pitch and array of solder ball with composition of Sn1.0Ag0.5Cu. The board systems by JEDEC standard including 15 chips, solder balls and PCB are modeled with various design parameter combinations, and through these simulations, maximum yield stress and strain at each chip are shown at the solder balls. It is found that larger chip size, smaller chip array, smaller ball diameter, larger pitch, and larger chip thickness have bad effect on maximum yield stress and strain at solder ball of each chip.

자동차 전장부품의 유한요소 모델링 및 실험적 검증 (Finite Element Modeling and Experimental Verification of the Automotive Electronics)

  • 오세종;이해진;강원호;이정윤;오재응
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 추계 학술대회논문집(수송기계편)
    • /
    • pp.204-207
    • /
    • 2005
  • A reliable and practical finite element modeling technique to predict the lifetime of automotive electronics is important for engineers in reliability. In reliability evaluation on the automotive electronics, most studies rarely used FE model verification process. The material properties and boundary conditions are very important factors in this process to assure the reliability of the automotive electronics. This study aims to develop a better and more accurate FE model in order to predict fatigue life of the automotive electronics using Virtual Qualification lifetime assessment techniques. After conducting the modal analysis by the experiments to grasp a system characteristic, this paper presents material properties and boundary conditions that is obtained by the comparisons of FEA simulation results using DOE technique and the experiment results.

  • PDF

고온초전도 Homopolar 전동기용 계자코일의 설계 및 특성평가 (Design and Test of HTS Homopolar Motor Field coil)

  • 이재득;이상호;김호민;이언용;백승규;권영길;홍정표;박민원;유인근
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.784-785
    • /
    • 2008
  • In general, in most case of high temperature superconducting (HTS) rotating machinery, HTS field coil is rotated. HTS homopolar motor field coil is nat necessary to be rotated and the torque of motor is not strongly related with the field coil. Therefore, HTS homopolar motor has a superior mechanical stability comparing with other HTS rotating machines. These advantages can make the design of HTS field coil and cryostat much more simple. In this paper, HTS field coil was fabricated and tested. Before test, authors habe estimated the critical current of HTS field coil at 77K by simulation using FEA (Finite Element Analysis) software and power law equation. The experiment details and results are presented in this paper, and discussed. The field windings are made with HTS Bi-2223 wire which operates at 77K.

  • PDF

플레이트의 소성변형 과정이 재건술에서 플레이트 안정성에 미치는 영향 (On the Stability of the Permanently Bent Mini-plate in Reconstructive Surgery)

  • 박시명;이득희;노건우
    • 한국CDE학회논문집
    • /
    • 제21권3호
    • /
    • pp.234-241
    • /
    • 2016
  • Conventional bent plate used in mandibular reconstruction surgery needs safety verification since its mechanical properties are changed due to the plastic deformation during the bending process. In this study we investigate stability of the plastically deformed plate and the plate with the same shape without plastic deformation through the finite element analysis(FEA). First we simulate the process of plate bending to fit the defect in patient. Then, the other plate is modelled to represent a customized plate with the same shape of the plastically deformed one, but without any residual stresses from plastic deformation. After binding these plates to the mandible, we conduct the masticatory simulation. Finally, we compare the resulting Von Mises stress of the customized plate and of the bent plate. The bent plate shows much higher stress than the customized one due to the residual stresses form the bending process. The study shows that plastic deformation in the plate may decrease the safety of the reconstruction surgery.