• Title/Summary/Keyword: FE model Calibration

Search Result 25, Processing Time 0.028 seconds

Assessment on Natural Frequencies of Structures using Field Measurement and FE Analysis

  • Kim, Do Hyun;Kim, Ji Young
    • International Journal of High-Rise Buildings
    • /
    • v.3 no.4
    • /
    • pp.305-310
    • /
    • 2014
  • Wind-induced responses of a structure are often evaluated through dynamic analysis, where measured wind forces obtained from a wind-tunnel test and dynamic properties obtained from a FE (Finite Element) model are utilized. However, the FE model generally shows considerable discrepancies in the estimation of natural frequencies compared to field measurements due to some assumptions and simplifications. In this paper, a calibration method that can improve the estimation of natural frequencies in the FE model is proposed, and specific cases are studied for its validity with comparison to the field measurement results.

THE EVOLUTION OF THE GALACTIC GLOBULAR CLUSTERS.: I. METAL ABUNDANCE CALIBRATIONS

  • Lee, See-Woo;Park, Nam-Kyu
    • Journal of The Korean Astronomical Society
    • /
    • v.17 no.2
    • /
    • pp.69-103
    • /
    • 1984
  • Five different calibrations of metal abundances of globular clusters are examined and these are compared with metallicity ranking parameters such as $(Sp)_c$, . Q39 and IR-indices. Except for the calibration $[Fe/H]_H$ by the high dispersion echelle analysis. the other calibration scales are correlated with the morphological parameters of red giant branch. In the $[Fe/H]_H$-scale. the clusters later than ${\sim}F8$ have nearly a constant metal abundance. $[Fe/H]_H{\simeq}-1.05$, regradless of morphological characteristics of horizontal branch and red giant branch. By the two fundamental calibration scales of $[Fe/H]_L$ (derived by the low dispersion analysis) and $[Fe/H]_{{\Delta}s}$ (derived by the spectral analysis of RR Lyrae stars). the globular clusters are divided into the halo clusters with [Fe/H]<-1.0 and the disk clusters confined within the galactocentric distance ${\tau}_G=10\;kpc$ and galactic plane distance |z|=3 kpc. In this case the abundance gradient is given by d[Fe/H]/$dr_G{\approx}-0.05\;kpc^{-1}$ and d[Fe/H]/$d|z|{\simeq}-0.08\;kpc^{-1}$ within ${\tau}_G=20\;kpc$ and |z|=10 kpc, respectively. According to these characteristics of the spatial distribution of globular clusters. the chemical evolution of the galactic globular clusters can be accounted for by the two-zone (disk-halo) slow collapse model when the $[Fe/H]_L$-or $[Fe/H]_{{\Delta}s}$-scale is applied. In the case of $[Fe/H]_H$-scale, the one-zone fast collapse model is preferred for the evolution of globular clusters.

  • PDF

Verification of FE models for various types of structures using measured dynamci properties (동특성 계측을 통한 건물 구조형식별 FE 구조해석 모델의 검증)

  • Kim, Ji-Young;Park, Jae-Keun;Cho, Ja-Ock;Yu, Eun-Jong;Kim, Dae-Young
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2011.04a
    • /
    • pp.598-601
    • /
    • 2011
  • 동적응답과 하중을 정확히 산정하기 위해서는 구조물의 동적특성을 정확히 평가하는 것이 중요하기 때문에, 현재 대부분의 경우 FE 모델을 이용한 Modal 해석을 dldydg하여 동특성을 평가하고 있다. 그러나 실제 건물의 계측결과와 동적특성의 해석결과가 많은 차이를 나타내고 있으므로 해석결과의 신뢰성을 향상하기 위해서는 FE 모델에 대한 Calibration이 수행될 필요성이 있다. 이 논문에서는 초고층, 아파트, 대공간 구조물에 대한 계측을 수행하고 이 결과를 바탕으로 동특성을 정확히 예측하기 위한 FE 모델의Calibration 과정을 제시하였다. 이 결과를 바탕으로 동적특성의 정확성이 풍동실험결과의 신뢰성에 미치는 영향을 분석하였다.

  • PDF

FVT Signal Processing for Structural Identification of Cable-stayed Bridge (사장교의 구조식별을 위한 가진실험 데이터분석)

  • 이정휘;김정인;윤자걸
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.14 no.10
    • /
    • pp.923-929
    • /
    • 2004
  • In this research, Forced Vibration Test(FVT) on a cable stayed bridge was conducted to examine the validity of the frequency domain pattern recognition method using signal anomaly index and artificial neuralnetwork. 7he considering structure, Samchunpo Bridge, located in Sachun-Shi, Kyungsangnam-Do, is a cable stayed bridge with the 436 meter span. The excitation force was induced by a sudden braking of a fully loaded truck. and vortical acceleration signals were acquired at 14 points. The initial 2-dimensional FE-model was developed from the design documents to prepare the training sets for the artificial neural network, and then the model calibration was performed with the field test data. As a result of the model calibration, we obtained the FFT spectrums from the model simulation, which was similar to those from the vibration test. These tests and the simulation data will be used for the structural identification using arbitrarily added masses to the bridge.

FVT Signal Processing for Structural Identification of Cable-Stayed Bridge (사장교의 구조식별을 위한 가진실험 데이터분석)

  • 윤자걸;이정휘;김정인
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.11a
    • /
    • pp.619-623
    • /
    • 2003
  • In this research, Forced Vibration Test(FVT) on a cable stayed bridge was conducted to examine the validity of the frequency domain pattern recognition method using signal anomaly index and artificial neural network. The considering structure, Samchunpo Bridge, located in Sachun-Shi, Kyungsangnam-Do, is a cable stayed bridge with the 436 meter span. The excitation force was induced by a sudden braking of a fully loaded truck, and vertical acceleration signals were acquired at 14 points. The initial 2-dimensional FE-model was developed from the design documents to prepare the training sets for the artificial neural network, and then the model calibration was performed with the field test data. As a result of the model calibration, we obtained the FFT spectrums from the model simulation, which was similar to those from the vibration test. These tests and the simulation data will be used fur the structural identification using arbitrarily added masses to the bridge.

  • PDF

FE Model Calibration of Myeong-dong Cathedral Using Vibration Measurement Data (진동 계측 데이터를 이용한 명동 성당 유한요소 모델 개선)

  • Hwang, In Hwan;Jeon, Jin Yong;Kim, Ji Young
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.23 no.11
    • /
    • pp.987-995
    • /
    • 2013
  • One of the most important processes to accurately predict structural responses is to evaluate accurate structural dynamic characteristics using finite element(FE) models. The numerical structural dynamic characteristics usually show considerable discrepancies with the measured ones because structural details are commonly simplified in the FE models. To identify such discrepancies, FE models of them have been calibrated using the measured dynamic characteristics in previous researches. In this study, the dynamic characteristics were measured for a historic cathedral and the FE model of it was calibrated using the measured results as a reference. Finally, a procedure of the FE model construction for the unreinforced masonry cathedral were tentatively proposed.

POLARIZATION-MAGNETIC FIELD CALIBRATION CURVE (편광-자기장 눈금조정 곡선)

  • Kim, Kap-Sung
    • Publications of The Korean Astronomical Society
    • /
    • v.12 no.1
    • /
    • pp.1-21
    • /
    • 1997
  • We have obtained theoretical calibration curves to convert the amount of polarization into the strength of magnetic field, by a numerical calculation of radiation transfer for the polarized spectral line of FeI $6303{\AA}$. In our calculation, three kinds of atmospheric models (VAL-C, penumbra, umbra) have been used to make a proper calibration for an active region composed of quiet, penumbral and umbral areas. It was found that firstly, the results of our calculation depend highly on a kind of atmospheric model rather than on any other input parameters used in a model. Secondly, observed line profile showed m solar spectrum atlas proved to be very similar to the calculated profiles obtained by using a penumbra model. Finally, another method except this calibration curve should be developed to estimate correctly the distribution of magnetic field in solar active region from the observation of polarized spectral line.

  • PDF

Vibration based damage detection in a scaled reinforced concrete building by FE model updating

  • Turker, Temel;Bayraktar, Alemdar
    • Computers and Concrete
    • /
    • v.14 no.1
    • /
    • pp.73-90
    • /
    • 2014
  • The traditional destructive tests in damage detection require high cost, long consuming time, repairing of damaged members, etc. In addition to these, powerful equipments with advanced technology have motivated development of global vibration based damage detection methods. These methods base on observation of the changes in the structural dynamic properties and updating finite element models. The existence, location, severity and effect on the structural behavior of the damages can be identified by using these methods. The main idea in these methods is to minimize the differences between analytical and experimental natural frequencies. In this study, an application of damage detection using model updating method was presented on a one storey reinforced concrete (RC) building model. The model was designed to be 1/2 scale of a real building. The measurements on the model were performed by using ten uni-axial seismic accelerometers which were placed to the floor level. The presented damage identification procedure mainly consists of five steps: initial finite element modeling, testing of the undamaged model, finite element model calibration, testing of the damaged model, and damage detection with model updating. The elasticity modulus was selected as variable parameter for model calibration, while the inertia moment of section was selected for model updating. The first three modes were taken into consideration. The possible damaged members were estimated by considering the change ratio in the inertia moment. It was concluded that the finite element model calibration was required for structures to later evaluations such as damage, fatigue, etc. The presented model updating based procedure was very effective and useful for RC structures in the damage identification.

The Construction of Initial Analytical Models Structural Health Monitoring of a Masonry Structure

  • Kim, Seonwoong;Kim, Ji Young;Hwang, In Hwan
    • International Journal of High-Rise Buildings
    • /
    • v.4 no.3
    • /
    • pp.191-198
    • /
    • 2015
  • It is important to accurately predict structural responses to external excitations such as typhoons and earthquakes when designing structures for serviceability. One of the key procedures to predict reliable vibration responses is to evaluate accurate structural dynamic properties using finite element (FE) models, which properly represent the realistic behavior of buildings. In the case of historic masonry buildings, structural damage could also be caused by ambient vibrations or impacts. Therefore, the preservation plans of historic buildings for low-level vibrations or impacts should be provided by analyzing structural damages within serviceability levels. For this purpose, it is required to provide FE model construction and response analysis methods verified with field measurement data. In this research, long-term field measurement was performed for a cathedral and its dynamic properties were evaluated using measured data. Then, the model was calibrated based on the measured dynamic properties and an overall construction method for the masonry cathedral was proposed. Using the measured accelerations, the vibrations of the belfry were analyzed using the calibrated FE model and finally, the FE model for the cathedral was verified by comparing the measured accelerations with the modeled results.

CALIBRATION OF VECTOR MAGNETOGRAMS BY SOLAR FLARE TELESCOPE OF BOAO

  • MOON YONG-JAE;PARK YOUNG DEUK;YUN HONG SIK
    • Journal of The Korean Astronomical Society
    • /
    • v.32 no.1
    • /
    • pp.65-73
    • /
    • 1999
  • In this study we present a new improved nonlinear calibration method for vector magnetograms made by the Solar Flare Telescope of BOAO. To identify Fe I 6302.5 line, we have scanned monochromatic images of the line integrated over filter passband, changing the location of the central transmission wavelength of a Lyot filter. Then we obtained a filter-convolved line profile, which is in good agreement with spectral atlas data provided by the Sacramento Peak Solar Observatory. The line profile has been used to derive calibration coefficients of longitudinal and transverse fields, employing the conventional line slope method under the weak field approximation. Our improved nonlinear calibration method has also been used to calculate theoretical Stokes polarization signals with various angles of inclination of magnetic fields. For its numerical test, we have compared input magnetic fields with the calibrated ones, which have been derived from the new improved non-linear method and the conventional method respectively. The numerical test shows that the calibrated fields obtained from the improved method are consistent with the input fields, but not with those from the conventional method. Finally, we applied our new improved method to a dipole model which characterizes a typical field configuration of a single, round sunspot. It is noted that the conventional method remarkably underestimates the transverse field component near the inner penumbra.

  • PDF