Browse > Article
http://dx.doi.org/10.5050/KSNVE.2013.23.11.987

FE Model Calibration of Myeong-dong Cathedral Using Vibration Measurement Data  

Hwang, In Hwan (Hanyang University)
Jeon, Jin Yong (Hanyang University)
Kim, Ji Young (Daewoo Institute of Construction Technology, Daewoo E&C)
Publication Information
Transactions of the Korean Society for Noise and Vibration Engineering / v.23, no.11, 2013 , pp. 987-995 More about this Journal
Abstract
One of the most important processes to accurately predict structural responses is to evaluate accurate structural dynamic characteristics using finite element(FE) models. The numerical structural dynamic characteristics usually show considerable discrepancies with the measured ones because structural details are commonly simplified in the FE models. To identify such discrepancies, FE models of them have been calibrated using the measured dynamic characteristics in previous researches. In this study, the dynamic characteristics were measured for a historic cathedral and the FE model of it was calibrated using the measured results as a reference. Finally, a procedure of the FE model construction for the unreinforced masonry cathedral were tentatively proposed.
Keywords
Myeong-dong Cathedral; Vibration Measurement; FE Model;
Citations & Related Records
Times Cited By KSCI : 1  (Citation Analysis)
연도 인용수 순위
1 Sima, J. F., Roca, P. and Climent, M., 2011, Nonlinear Response of Masonry Wall Structures Subjected to Cyclic and Dynamic Loading, Engineering Structures, Vol. 33, No. 6, pp. 1955-1965.   DOI   ScienceOn
2 Lourenco, B. P., Trujillo, A., Mendes, N. and Ramos, F. L., 2012, Seismic Performance of the St. George of the Latins Church; Lessons Learned from Studying Masonry Ruins, Engineering Structures, Vol. 40, No. 1, pp. 501-518.   DOI   ScienceOn
3 Lee, J. H., Kim, J. S., Kim, H. W. and Park, B. C., 2012, Correlation Evaluation between Damage and Natural Frequency on URM Walls, Proceedings of the KSNVE Annual Spring Conference, pp. 493-494.   과학기술학회마을
4 Kim, J. S., Kim, H. W., Lee, J. H. and Park, B. C., 2012, Natural Frequency Analysis of Mansonry Buildings under Seismic Excitations, Proceedings of the KSNVE Annual Spring Conference, pp. 495-496.
5 Choi, J. S. and Min, K. W., 2012, A Case Study of Analysis and Evaluation of Vibration by Construction of Cast in Place Concrete Pile in the Neighboring Areas of Heunginjimun, Transactions of the Korean Society for Noise and Vibration Engineering, Vol. 22, No. 9, pp. 870-878.   과학기술학회마을   DOI   ScienceOn
6 HKS, 2012, ABAQUS/Explicit User's Manual Version 6.12, Hibbitt, Karlsson & Sorensen, Inc., Rawtucket, RI.
7 Cultural Heritage Administration of Korea, 2002, Myeong-dong Cathedral Research Investigation Report, Cultural Heritage Administration of Korea, Seoul.
8 Brincker, R., Ventura, C. E. and Andersen, P., 2001, Damping Estimation by Frequency Domain Decomposition, Proceeding of 19th International Modal Analysis Conference(IMAC), 4359(1), pp. 698-703.
9 Ministry of Land, Infrastructure and Transport, 2009, Building Structure Standards of Korea(KBC 2009), Ministry of Land, Infrastructure and Transport
10 Korea Infrastructure Safe and Technology Corporation, 2010, Precision Safety Diagnosis Report of Myeong-dong Cathedral, Catholic Archdiocese of Seoul.
11 Applied Technology Council(ATC), 1998, Evaluation of Earthquake Demaged Concrete and Masonry Wall Buildings(FEMA 306), Federal Emergency Management Agency(FEMA).
12 Li, Q. S., Xiao, Y. Q. and Wonga, A., 2004, Field Measurements of Typhoon Effects on Super Tall Building, Engineering Structures, Vol. 26, No. 2, pp. 233-244.   DOI   ScienceOn
13 Kim, J. Y., Yu, E. J., Kim, D. Y. and Tamura, Y., 2011, Long-term Monitoring of Wind-induced Responses of a Large-span Roof Structure, J. Wind Eng. Ind. Aerodyn., Vol. 99, No. 9, pp. 955-963.   DOI   ScienceOn
14 Lia, Q. S., Xiao, Y. Q., Fu, J. Y. and Li, Z. N., 2007, Full-scale Measurements of Wind Effects on the Jin Mao Building, J. Wind Eng. Ind. Aerodyn., Vol. 95, No. 6, pp. 445-466.   DOI   ScienceOn
15 Fu, J. Y., Li, Q. S., Wu, J. R., Xiao, Y. Q. and Song, L. L., 2008, Field Measurements of Boundary Layer Wind Characteristics and Wind-induced Responses of Super-tall Buildings, J. Wind Eng. Ind. Aerodyn., Vol. 96, No. 8-9, pp. 1332-1358.   DOI   ScienceOn
16 Kim, J. Y., Yu, E. J., Kim, D. Y. and Kim, S. D., 2009, Calibration of Analytical Models to Assess Wind-induced Acceleration Responses of Tall Buildings in Serviceability Level, Engineering Structures, Vol. 31, No. 9, pp. 2086-2096.   DOI   ScienceOn
17 Wu, C., Hao, H. and Lu, Y., 2005, Dynamic Response and Damage Analysis of Masonry Structure and Masonry Infilled RC Frame to Blast Ground Motion, Engineering Structures, Vol. 27, No. 3, pp. 323-333.   DOI   ScienceOn
18 Mallardo, V., Malvezzi, R., Milani, E. and Milani, G., 2008, Seismic Vulnerability of Historical Mansonry Buildings; A Case Study in Ferrere, Engineering Structures, Vol. 30, No. 8, pp. 2223-2241.   DOI   ScienceOn
19 Park, J. N., Towashiraporn, P., Craig, I. J. and Goodnod, J. B., 2009, Seismic Fragility Analysis of Low-rise Unreinforced Masonry Structures, Engineering Structures, Vol. 31, No. 1, pp. 125-137.   DOI   ScienceOn