• Title/Summary/Keyword: FDR

Search Result 166, Processing Time 0.02 seconds

Scheduling Non-drainage Irrigation in Coir Substrate Hydroponics with Different Percentages of Chips and Dust for Tomato Cultivation using a Frequency Domain Reflectometry Sensor (토마토 수경재배에서 FDR(Frequency Domain Reflectometry) 센서를 활용한 무배액 시스템에 적합한 코이어 배지의 Chip과 Dust 비율 구명)

  • Choi, Eun-Young;Choi, Ki-Young;Lee, Yong-Beom
    • Journal of Bio-Environment Control
    • /
    • v.22 no.3
    • /
    • pp.248-255
    • /
    • 2013
  • This study examined an automated irrigation technique by a frequency domain reflectometry (FDR) sensor for scheduling irrigation for tomato (Solanum lycopersicum L. 'Starbuck F1') cultivation aimed at avoiding effluent from an open hydroponic system with coir substrate containing different ratios of chip-to-dust (v/v) content. Specifically, the objectives were to undertake preliminary measurements of irrigation volumes, leachate volume, volumetric water content and electrical conductivity (EC) in the substrate, plant growth, fruit yield, and water use efficiency resulting from variation in chip content as an initial experiment. Commercial coir substrates containing different percentages of chips and dust (0 and 100%, 30 and 70%, 50 and 50%, or 70 and 30%), two-story coir substrates with different percentages of chips in the lower layer and dust in the upper layer (15 and 85%, 25 and 75%, or 35 and 65%), or rockwool slabs were used. The results showed that a negligible or no leachate was found for all treatments when plants were grown under a technique for scheduling non-drainage irrigation using a frequency domain reflectometry (FDR) sensor. Daily irrigation volume was affected by chip content in both commercial and two-story slabs. The highest plant growth, marketable fruit weight, and water-use efficiency were observed in the plants grown in the commercial coir slab containing 0% chips and 100% dust, indicating that the FDR sensor-auto-mated irrigation may be more useful for tomato cultivation in coir substrate containing 0% chips and 100% dust using water efficiently and minimizing or avoiding leachate and thus increasing yield and reducing pollution. Detailed experiment is necessary to closely focus on determining appropriate irrigation volume at each of irrigation as well as duration of each individual irrigation cycle depending on different physical properties of substrates using an automated irrigation system operated by the FDR sensor.

Development of Continuous Monitoring Method of Root-zone Electrical Conductivity using FDR Sensor in Greenhouse Hydroponics Cultivation (시설 수경재배에서 FDR 센서를 활용한 근권 내 농도의 연속적 모니터링 방법)

  • Lee, Jae Seong;Shin, Jong Hwa
    • Journal of Bio-Environment Control
    • /
    • v.31 no.4
    • /
    • pp.409-415
    • /
    • 2022
  • Plant growth and development are also affected by root-zone environment. Therefore, it is important to consider the variables of the root-zone environment when establishing an irrigation strategy. The purpose of this study is to analyze the relationship between the volumetric moisture content (VWC), Bulk EC (ECb), and Pore EC (ECp) used by plant roots using FDR sensors in two types of rockwool media with different water transmission characteristics, using the method above this was used to establish a method for collecting and correcting available root-zone environmental data. For the experiment, two types of rockwool medium (RW1, RW2) with different physical characteristics were used. The moisture content (MC) and ECb were measured using an FDR sensor, ECp was measured after extracting the residual nutrient solution from the medium using a disposable syringe in the center of the medium at a volumetric moisture content (VWC) of 10-100%. Then, ECb and ECp are measured by supplying nutrient solution having different concentration (distilled water, 0.5-5.0) to two types of media (RW1, RW2) in each volume water content range (0 to 100%). The relationship between ECb and ECp in RW1 and RW2 media is best suited for cubic polynomial. The relationship between ECb and ECp according to volume moisture content (VWC) range showed a large error rate in the low volume moisture content (VWC) range of 10-60%. The correlation between the sensor measured value (ECb) and the ECp used by plant roots according to the volumetric water content (VWC) range was the most suitable for the Paraboloid equation in both media (RW1, RW2). The coefficient of determination the calibration equation for RW1 and RW2 media were 0.936, 0.947, respectively.

Synthesis of FDR-SPC Resin and PIV Measurement for Frictional Drag-reduction (마찰저항 저감을 위한 고분자 수지 합성 및 PIV 유동장 계측)

  • Chung, Sungwoo;Kim, Eunyoung;Chun, Ho Hwan;Park, Hyun;Lee, Inwon
    • Journal of the Korean Society of Visualization
    • /
    • v.12 no.1
    • /
    • pp.49-53
    • /
    • 2014
  • In this study, a novel FDR-SPC is first synthesized in this study. The drag reducing functional radical such as PEGMA (Poly(ethylene) glycol methacrylate) has been utilized to participate in the synthesis process of the SPC. The types of the baseline SPC monomers, the molecular weight and the mole fraction of PEGMA were varied in the synthesis process. The resulting SPCs were coated to the substrate plates for the subsequent hydrodynamic test for skin friction measurement. In a low-Reynolds number flow measurement using PIV (Particle Image Velocimeter), a significant reduction in Reynolds stress was observed in a range of specimen, with the maximum drag reduction being 15.9% relative to the smooth surface.

Gene Screening and Clustering of Yeast Microarray Gene Expression Data (효모 마이크로어레이 유전자 발현 데이터에 대한 유전자 선별 및 군집분석)

  • Lee, Kyung-A;Kim, Tae-Houn;Kim, Jae-Hee
    • The Korean Journal of Applied Statistics
    • /
    • v.24 no.6
    • /
    • pp.1077-1094
    • /
    • 2011
  • We accomplish clustering analyses for yeast cell cycle microarray expression data. To reflect the characteristics of a time-course data, we screen the genes using the test statistics with Fourier coefficients applying a FDR procedure. We compare the results done by model-based clustering, K-means, PAM, SOM, hierarchical Ward method and Fuzzy method with the yeast data. As the validity measure for clustering results, connectivity, Dunn index and silhouette values are computed and compared. A biological interpretation with GO analysis is also included.

Advanced Frequency Estimation Technique using Gain Compensation (이득 보상에 의한 개선된 주파수 추정 알고리즘)

  • Park, Chul-Won
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.59 no.2
    • /
    • pp.173-178
    • /
    • 2010
  • Frequency is an important operating parameter of a power system. Due to the sudden change in generation and loads or faults in power system, the frequency is supposed to deviate from its nominal value. It is essential that the frequency of a power system be maintained very close to its nominal frequency. And monitoring and an accurate estimation of the power frequency by timing synchronized signal provided by FDR is essential to optimum operation and prevention for wide area blackout. As most conventional frequency estimation schemes are based on DFT filter, it has been pointed out that the gain error by change in magnitude could cause the defects when the power frequency is deviated from nominal value. In this paper, an advanced frequency estimation scheme using gain compensation for fault disturbance recorders (FDR) is presented. The proposed scheme can reduce the gain error caused when the power frequency is deviated from nominal value. Various simulation using both the data from EMTP package and user's defined arbitrary signals are performed to demonstrate the effectiveness of the proposed scheme. The simulation results show that the proposed scheme can provide better accuracy and higher robustness to harmonics and noise under both steady state tests and dynamic conditions.

Association between oropharyngeal microbiome and weight gain in piglets during pre and post weaning life

  • Bugenyi, Andrew Wange;Cho, Ho-Seong;Heo, Jaeyoung
    • Journal of Animal Science and Technology
    • /
    • v.62 no.2
    • /
    • pp.247-262
    • /
    • 2020
  • Birth weight and subsequent weight gain is of critical importance in the survival and performance of piglets on a commercial swine farm setting. Oropharyngeal microbiome could influence immunity, and feeding behavior thus impacting health and weight gain. We used 16S rRNA gene sequencing to profile the composition and predicted metabolic functionality of the oropharyngeal microbiota in 8 piglets (4 with a birthweight ≤ 1.0 kg and 4 with a birthweight ≥ 1.7 kg) at 11, 26, and 63 days of age. We found 9 genera that were significantly associated with average daily gain (ADG) at 11 days (false discovery rate, FDR < 0.05) and 26 days of age (FDR < 0.1), respectively. The microbial functional profile revealed several pathways associated with ADG (FDR < 0.05). Among these, pathways related to degradation of catechols showed a positive association with ADG at 11, 26, and 63 days of age, implying a potential to breakdown the host-derived catecholamines. We also noted that pathways related to the biodegradation of nucleosides and nucleotides increased with ADG during the pre-weaning phase, while those involved in their biosynthesis decreased. Our findings provide insights into the oropharyngeal microbial memberships and metabolic pathways that are involved in a piglet's weight gain. Thus, providing a basis for the development of strategies aimed at improving weight gain in pigs.

Comparison of multiscale multiple change-points estimators (SMUCE와 FDR segmentation 방법에 의한 다중변화점 추정법 비교)

  • Kim, Jaehee
    • The Korean Journal of Applied Statistics
    • /
    • v.32 no.4
    • /
    • pp.561-572
    • /
    • 2019
  • We study false discovery rate segmentation (FDRSeg) and simultaneous multiscale change-point estimator (SMUCE) methods for multiscale multiple change-point estimation, and compare empirical behavior via simulation. FSRSeg is based on the control of a false discovery rate while SMUCE used for the multiscale local likelihood ratio tests. FDRSeg seems to work best if the number of change-points is large; however, FDRSeg and SMUCE methods can both provide similar estimation results when there are only a small number of change-points. As a real data application, multiple change-points estimation is done with the well-log data.

Formal Methodology for Safety Analysis of Security Protocols (보안 프로토콜의 안전성 분석을 위한 정형적 방법론)

  • Kim Il-Gon;Jeon Chul-Wuk;Kim Hyun-Seok;Choi Jin-Young;Kang In-Hye
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.15 no.1
    • /
    • pp.17-27
    • /
    • 2005
  • With the development of wire and wireless based networks, a various security protocols have been proposed to protect important resources and user information against attackers. However, many security protocols have found oかy to be later vulnerable to attacks. In this Paper, we introduce the formal methodology to verify the safety of security protocols in the design phase, and we take advantage of the formal methodology which uses Casper/CSP and FDR tools by introducing the verification example of EKE protocol and BCY protocol. Lastly, we propose a new BCY protocol after verifying it's safety.

Verification of Soil Volumetric Water Content Measured by TDR, FDR Sensors (TDR, FDR 센서로 측정한 토양수분 함량의 정확성 검정)

  • Hur, Seung-Oh;Jung, Kang-Ho;Park, Chan-Won;Ha, Sang-Keon;Kim, Jeong-Gyu
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2007.05a
    • /
    • pp.229-235
    • /
    • 2007
  • 관개나 수분수지 규명을 위한 기본적인 자료는 토양수분 함량이다. 그러나, 포장상태에서의 토양수분 함량은 직접 측정하는 것이 쉽지 않기 때문에 많은 경우 건조기를 이용한 중량수분 함량측정 방법을 이용하거나 토양수분 포텐셜 측정용인 텐시오미터를 이용한 토양수분의 에너지 특성을 관개에 활용하는 것이 현실이었다. 중량수분 함량은 시료를 채취해서 건조하기 때문에 시료채취 당시의 토양수분 함량을 아는 것이 어렵고, 토양수분 포텐셜은 에너지를 측정하는 것이기 때문에 이 역시 토양의 수분함량을 얻는 것이 불가능 하다. 따라서, 최근에 이런 측정상의 어려움을 극복하기 위해 여러 나라에서 포장에서의 토양수분 함량을 직접 측정하는 다양한 센서를 개발하고 있고 있다. 그 중 몇 가지는 현재 우리나라에 공급되고 있는데, 가격 등의 문제로 별로 알려져 있지는 않다. 센서는 현장에서 수분함량을 파악할 수 있는 장점이 있기 때문에 관개에 직접 적용이 가능하며 자동화시설이나 수분수지 모형 산정에도 활용할 수 있다. 본 시험은 우리나라에 소개되어 있는 몇 가지의 토양수분 측정용 센서를 현장에서 코어를 이용해 측정한 용적수분 함량과 비교하여 센서의 정확도나 이용 가능성을 검정하고자 하였다. 코어를 이용해 실측한 토양 용적수분 함량과 비교하고자 7종의 센서를 선택해 실험에 이용하였다. 가격이 비싼 것으로 알려진 TDR 형태의 센서가 2종이었으며, 나머지 5종은 FDR 형태의 센서였다. TDR 센서는 Soilmoisture사에서 제작한 MiniTrase와 Imko 사의 Trime이고, FDR은 Sentek사에서 개발한 EasyAG, EnviroSCAN과 Delta-T사에서 제작한 PR-1과 WET-2 및 Decagon사에서 제작한 $ECH_2O$ 센서였다. 실헙방법은 본량사양토인 포장에서 건조한 상태인 시험구와 물이 포화된 시험구를 만들어 놓고, 그곳에서 센서 종류별로, 측정 깊이별로 토양의 용적수분 함량을 측정하고, 센서로 측정한 위치 바로 옆에서 코어를 이용해 토양시료를 채취하고 이를 건조기에 건조해 용적수분 함량을 측정하였다. 비교결과 TDR인 MiniTrase가 결정계수$(r^2)$가 0.964이고 표준오차(SE)가 0.01로 좋은 결과를 보여줬고 WET-2가 $r^2$와 SE가 0.932와 0.013이였으며 EasyAG는 0.877과 0.0211, EnviroSCAN은 0.803과 0.0259의 값을 보였다. 일반적으로 토양수분 함량 측정오차가 1% 미만인 센서가 정확한 수분함량 해석을 유도할 것이지만 위의 센서 중 MiniTrase를 비롯한 4개의 센서 정도가 토양의 수분 함량을 측정하는데 유용할 것이라는 결론을 얻었다.

  • PDF

Evaluation of Oil Infiltration Behavior in Porous Media Using Dielectric Response (유전율에 의한 지반 매질내 유류침투거동 분석)

  • Kim Man-Il;Jeong Gyo-Cheol
    • The Journal of Engineering Geology
    • /
    • v.15 no.1
    • /
    • pp.29-39
    • /
    • 2005
  • For detecting a ground contamination survey, soil sampling method have been used a drilling or coring technique in general. However these methods are very difficult to systematically real-time monitoring of variation of contamination degree in field. ]'n this research frequency Domain Reflectometry (FDR) system was suggested and carried out to experimental approaches for determination of oil contamination on surface and underground. Experimental method using FDR method was discussed with feasibility of measurement in the laboratory column test. It is determined to degree of oil contamination due to response of dielectric constant re-lated with volumetric water content(θ/sub w/) and volumetric oil content( θ/sub al/ ) of saturated and unsaturated soil media. And physical properties such as effective porosity and oil residual ratio of saturated soil media were also measured through real-time monitoring works using installed FDR measurement sensors, which are defected characteristics of oil movement in the saturated soil media under the soil column tests. In the results of these experiments, a range of effective porosity was estimated to about 0.35 compared with initial porosity 0.40 of manufactured saturated soil media, which is also calculated to about 87.5% to the ratio of initial porosity to effective porosity. Finally oil residual ratio which is compared with volumetric water content and volumetric oil content was calculated about 62.5%.