• 제목/요약/키워드: FACTs

검색결과 2,499건 처리시간 0.027초

Optimal Placement for FACTS to Improve Static Voltage Stability

  • Gu, Min-Yan;Baek, Young-Sik
    • KIEE International Transactions on Power Engineering
    • /
    • 제4A권3호
    • /
    • pp.141-145
    • /
    • 2004
  • FACTS devices, such as the Thyristor Controlled Series Compensator (TCSC) and Static Var Compensators (SVC), can help increase system load margin to improve static voltage stability. In power systems, because of the high cost and the effect value, the optimal placement for FACTS devices must be determined. This paper investigates the use of the series device (SVC) and the parallel device (TCSC) from the point of load margin to increase voltage stability. It considers the sensitivity of load margin to the line reactance and eigenvector of the collapse. The study has been carried out on the IEEE 14 Bus Test System to verify the validity and efficiency of the method. It reveals that incorporation of FACTS devices significantly enhance load margin as well as system stability.

대규모 전려계통에서의 하위 송전계통 축약을 이용한 FACTS 위치선정 연구 (FACTS Site Selections in Large Power Systems using Subtransmission System Reduction)

  • 장병훈;추진부;권세혁
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제48권11호
    • /
    • pp.1429-1433
    • /
    • 1999
  • This paper proposes the FACTS site selection method using subtransmission system reduction. A general method which uses the sensitivity of the variation in voltage and reactive power has been used to determine the location of shunt type FACTS device, but there is a difficulty to finding a proper location due to the overestimation of the effect of sub-transmission systems. Therefore, there is a need to reduce sub-transmission system for finding an effective location of shunt type FACTS devices such as SVC(Static Var Compensator), STATCOM(Static Synchronous Compesator), and so on.

  • PDF

수도권 FACTS 상호영향 및 과도특성 분석 (Interaction and Transient Analysis to FACTS Devices in Seoul Area)

  • 윤종수;김재한;이성두;최장흠;서보혁
    • 전기학회논문지
    • /
    • 제59권11호
    • /
    • pp.1929-1935
    • /
    • 2010
  • This paper describes the operation effect of FACTS devices in the Korean power system. At the year of 2010, three FACTS devices is under commercial operation in the Seoul area. Among them, 345kV ${\pm}100MVA$ STATCOM at Mi-Geum substation and 345kV ${\pm}200MVA$ SVC at Dong-Seoul substation are very close at their electrical and geographical distance. Therefore, the additional analysis including interaction and mutual transient is necessary. Therefore, a detailed EMTDC/PSCAD simulation model was developed and steady-state/transient analysis was implemented.

단일 선로고장시 정적 안전도 향상을 위한 유연송전기기 운전 방안 (A Security-oriented Operation Scheme of FACTS Devices to Cope with A Single Line-faulted Contingency)

  • 임정욱
    • 조명전기설비학회논문지
    • /
    • 제18권3호
    • /
    • pp.149-155
    • /
    • 2004
  • 본 논문에서는 상정사고 해석을 통해 결정된 가장 심각한 단일 선로고장에 대하여 부하차단이나 재급전을 하지 않고, 유연송전기기의 운전만으로 안전도를 향상시켜 이를 극복할 수 있는 방법을 제시하였다. 즉, 직렬, 병렬, 직병렬보상기기 등 유연송전기기의 각 종류별로 정적 안전도 여유를 최대화하고 안전도 지수를 최소화하는 방법을 개발하였고, 이를 통하여 각 유연송전기기의 최적 운전점을 결정하는 방법을 개발하였다. 여기서, 정적 안전도 지수는 선로 조류 및 모선 전압에 관한 안전도를 정량화하여 식으로 나타낸 것이다. 안전도 지수가 작아지면 안전도 여유는 커지는데, 본 논문에서는 안전도 지수를 반복계산법으로 최소화하였다. 본 논문에서는 제안한 방법은 IEEE 57모션개통에 적용하여 제안된 방법의 정당성을 수치적으로 입증하였다.

염도계 및 Mohr법으로 측정된 HMR 제품의 나트륨 함량과 제품 영양표시 상의 나트륨 함량 비교 (Comparison of Sodium Contents in Nutrition Facts and Sodium Contents of HMR products by Salinity Meter and Mohr Method)

  • 김순미;박희옥
    • 한국식생활문화학회지
    • /
    • 제34권6호
    • /
    • pp.761-770
    • /
    • 2019
  • Two experiments were conducted to determine how much sodium in food could be detected using a salinity meter. First, the salinity of mixed solutions of 0 to 6% sugar, 0 to 5% oil, and 0 to 6.4% MSG in a 1% NaCl solution was measured using a salinity meter and a Mohr titration method, and the results were compared with the calculated sodium expectations. As a result, the sodium contents of the sugar solutions and MSG solutions measured using a salinity meter were lower than the expected concentrations at 2% or more and 0.8% or more, respectively (p<0.05). The salinity of the 18 HMR products was measured in the same way, and the results were then compared with the sodium contents of the nutrition facts. The average sodium content of all products measured using the salinity meter and Mohr method was 1.12 times and 1.06 times the sodium content of the nutrition facts, respectively. On the other hand, the differences between the products were significant. The correlation coefficients between the nutrition facts and salinity meter, the nutrition facts and the Mohr method, and the salinity meter and Mohr method were 0.885, 0.920, and 0.950, respectively (p<0.01).

전력시스템 동특성 해석을 위한 전압원 FACTS 기기의 Newton 전류 주입형 모델링에 관한 연구 (VSI FACTS Modeling Using Newton-Type Current Injection Method for Studying Power System Dynamics)

  • 박정수;손광명;장길수
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제55권7호
    • /
    • pp.281-289
    • /
    • 2006
  • Advanced controllers among Flexible AC Transmission System(FACTS) devices employ self-commutated switching converters, VSI (Voltage Sourced Inverters), as the synchronous voltage source. Such controllers are SSSC (Static Synchronous Series Compensator), STATCOM (Static Synchronous Compensator) and UPFC (Unified Power Flow Controller). UPFC is series-shunt combined controller. Its series and shunt inverters can be modeled as SSSC and STATCOM but the dependant relation between the inverters is very complex. For that reason, the complexity makes it difficult to develop the UPFC model by simply combining the SSSC and STATOM models when we apply the model for conventional power system dynamic simulation algorithm. Therefore, we need each relevant models of VSI type FACTS devices for power system analysis. This paper proposes a modeling approach which can be applied to modeling of VSI type FACTS devices. The proposed method using Newton-type current injection method can be used to make UPFC, SSSC, and STATCOM models. The proposed models are used for 2-area test system simulation, and the results verify their effectiveness.

중학생의 영양 성분 표시에 대한 구매 행동 및 이용 실태 - 충북 지역을 중심으로 - (The Actual State of Food Purchasing Behaviors Regarding Nutrition Facts Labels among Middle School Students in Chungbuk Area)

  • 김명희;최미경;김미원;전예숙;김미선
    • 한국식품영양학회지
    • /
    • 제23권4호
    • /
    • pp.492-500
    • /
    • 2010
  • This study conducted a questionnaire survey of 482 male and female second graders in middle schools located in Cheongju, Chungcheongbukdo. This study lays its purpose on establishing the nutrition facts labeling system by understanding eating habits and analyzing the actual state of reading nutrition facts labels and degrees of understanding them among middle school students, and helping them to engage in right food purchasing activities and through it result in developing sound eating habits by providing them with basic material to be employed to actively utilize nutrition facts for choosing and buying healthy foods. As a result of surveying regarding the actual state of reading food labels, regarding degrees of recognition of food labels, it was revealed that 91.1% of female students recognized them, while 42.1% of male students did not recognize them, indicating lower levels of recognition among the male group. Regarding reasons for not checking food labels, 49.2% indicated habitual purchasing, followed by poor contents in the label(20.2%), ununderstandable contents(17.7%), and the lower reliability of the contents(6.9%). As a result of surveying regarding the actual state of reading nutrition facts labels, in recognition of nutrition facts labels, female rather than male students showed higher degrees of recognition, and degrees of recognition were found to differ according to parents' total income and mothers' educational attainments.

가정내 아동에 대한 성적 학대사실의 발견방법에 관한 일 연구 (A Study on Ways of Finding sexual Abuse Facts of Children at Home)

  • 전형미
    • 대한가정학회지
    • /
    • 제35권6호
    • /
    • pp.191-203
    • /
    • 1997
  • This paper is study the ways of finding sexual abuse facts of children at home and the standards of recognizing such facts. The investigation and recognition about sexual abuse of children are necessary for remedy or care of children and their family and also for punishment upon the harmer or sanction against him by family laws. But, on account of the characteristics of sexual abuse acts and the standpoint that sufferers are children, it's very difficult to find those kinds of facts. Medical examinations, observations by specialists behavioral indicators, use of dolls & other props, and interviewing are applied to finding sexual abuse facts of children. However, these investigating methods have many uppermost limits, and don't necessarily have conformable conclusions. especially 'interviewing' is essentially used to find a child who has suffered sexual abuses and to investigate and examine a harmer who has been charged with such sexual acts. but 'interviewing' has no less obstacles in reality than has some utilities. For that reason, a follow-up study of (what is) the most effective method is required, with the case=by-case application of other methods. And along with that, it must be taken into consideration that, in process of finding a sexually abused child and in ex post facto measure against accompanying ill effects, the child's protection and the family's privacy ought to be legally guaranteed. So to speak, in making and enforcing the family laws, a profound study of the family to produce good fruits must be made.

  • PDF

안정도 향상을 위한 한전계통에서의 FACTS 투입 방안 모색 (Investment method of FACTS for improvement of stability for KEPCO System)

  • 강상균;이병준;권세혁;송화창;윤종수;장병훈
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 A
    • /
    • pp.208-210
    • /
    • 2005
  • 본 논문에서는 전압 불안정성을 해소시키기 위한 방안으로 FACTS를 투입하기 위한 방안에 대하여 논의 하였다. 우선적으로 전압안정도 기준을 수립하고 상정사고에 대하여 PV 해석을 실시하고 전압안정도 기준을 만족시키지 못하는 사고를 스크리닝 한다. 각 상정 사고에 대하여 선정된 전압안정도 기준을 만족하도록 하기 위한 FACTS 투입 방안에 대하여 논의하였다. 일반적으로 전압안정도 측면에서 취약위치를 선정하는 방법으로 VQ해석이나 Tangent vector에 의한 Bus sensitivity를 구하여 부하변화에 대한 전압 감도(dV/$dP_{TOTAL}$)가 큰 모선을 취약 위치로 선정하는 방법, 또는 Modal Analysis를 통해 구한 참여인수값이 큰 모선을 취약 모선으로 선정하는 방법이 있다. 이 논문에서는 VQ해석과 Tangent vector를 이용한 해석 방법을 이용하여 전압안정도 측면에서 취약 위치 및 전압안정도 향상을 위한 FACTS 투입 후보지를 선정하였고 전압안정도 기준을 만족시키기 위해 각 후보지에 투입해야할 FACTS 용량을 산정하였다. 마지막으로 실질적으로 수도권 주요 모선에 모두 FACTS를 투입한 결과와 논문에서 사용한 방법과의 결과를 비교하여 적절한 절차를 사용하여 FACTS가 투입되었음을 확인하였다.

  • PDF

전압안정도 향상을 위한 FACTS의 적용과 Bifurcation이론 해석 (FACTS Application for the Voltage Stability with the Analysis of Bifurcation Theory)

  • 주기성;김진오
    • 전력전자학회논문지
    • /
    • 제5권4호
    • /
    • pp.394-402
    • /
    • 2000
  • 본 논문온 전압안정도에 Brfurcation 이론을 적용하여 해석하고, FACTS기가인 SVC와 UPFC를 전력계통에 연계하였을 때 전압안정도가 향상되는 효과를 보여주고 있다. 전압안정도는 일반적으로 시스템 파라미터(유효전력 또는 무효전력}를 포행하는 고도의 비선형 동적시스템의 식들에 의해 표현된다. 때때로 전력계통에서의 파라미터 변이는 시스템 불안정을 일으키는 복잡한 동작을 일으킬 수도 있다. 전력계통에서의 FACTS의 연계는 이러한 전압안정도의 범위를 증가시킨다. FACTS를 이용하여 불안정한 HopF Bifurcation과 Saddle Node Bihlfcation을 지연시킴에 의해서 전압안정도기 향상됨을 사례연구를 통하여 입증하였다.

  • PDF