• Title/Summary/Keyword: FA test

Search Result 250, Processing Time 0.025 seconds

The Properties of Polyester Mortars with Various Fillers (충전재에 다른 폴리에스테르 모르타르의 특성)

  • 김성범;윤성진;최낙운;소승영;소양섭
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2003.11a
    • /
    • pp.449-452
    • /
    • 2003
  • The objective of this study is to investigate the basic properties of polyester mortars using ground calcium carbonate(GCC), blast furance slag(BFS), fly ash(FA), ordinary portland cement(OPC) as fillers. Particle size distribution, particle shape and resin absorption of GCC, BFS, FA and OPC are checked. Polyester mortars with GCC, BFS, FA and OPC are prepared with various MEKPO content and tested for working life. The flexural and compressive strengths of the polyester mortars with MEKPO content of 0.5phr are evaluated. As a test result, the average sizes of GCC, BFS, FA and OPC are 9.7$\mu\textrm{m}$, 11.6$\mu\textrm{m}$, 21.2$\mu\textrm{m}$, 29.9$\mu\textrm{m}$. Resin absorption of FA is 1.5times larger than other fillers. The polyester mortar with FA at a MEKPO content of 0.5phr has the longest working life and the maximum flexural and compressive strengths.

  • PDF

Corrosion-Resisting Performance Evaluation of Concrete Mixed with Fly-Ash (플라이애시 혼합 콘크리트의 철근 부식 저항성능 평가)

  • Park, Sang-Soon
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.21 no.1
    • /
    • pp.117-125
    • /
    • 2017
  • The role of fly ash in concrete become impotent with finding the characteristics of fly ash in which it is used as cement replacement material. In this paper, corrosion test results obtained by two test methods such as the long-term exposure corrosion test and the accelerated corrosion test method, were compared to investigated the corrosion resistance between fly ash concrete and normal concrete. Corrosion initiation time was measured in two types of concrete, i.e., one mixed with fly ash(FA) and the other without admixture(OPC). The accelerated corrosion test was carried out by four case, i.e., two samples is a cyclic drying-wetting method combined without carbonation(case 1) and combined with carbonation(case 2), and the other two samples is a artificial seawater ponding test method combined without carbonation(case 3) and combined with carbonation(case 4). Whether corrosion occurs, it was measures using half-cell potential method. The ponding test combined without carbonation was most effective in accelerating corrosion time of steel bars. The results indicated that the corrosion of rebar embedded in concrete occurred according to the order of OPC, FA. The delay relative ratio of corrosion obtained by corrosion initiation time between FA and OPC is 1.04 to 1.27. Consequently, fly ash concrete as the age increases its corrosion resistance was improved compared with OPC concrete.

Performance Analysis of an ORC System for Two Different Working Fluids (두 종류의 다른 작동유체가 ORC 시스템의 성능에 미치는 영향)

  • Chang, Hong-Soon;Song, Yeong-Kil;Han, Young-Sub
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.25 no.7
    • /
    • pp.413-417
    • /
    • 2013
  • The organic Rankine Cycle (ORC) uses a kind of refrigerant as a working fluid that evaporates at relatively low temperature, as the Rankine Cycle uses superheated steam as the working fluid. A small scale ORC test bench was installed, and two different working fluids (R245fa and R134a) were injected into the test bench. The test bench was in operation with the two different working fluids under the same conditions. The effects against the system performance from the different working fluids were analysed, and root causes were identified. Other factors reflecting the power generation efficiency were also found. A conclusion was drawn, that R245fa makes the system perform better, than R134a.

Feline panleukopenia virus infection in imported cats

  • Kang, Sang-Chul;Kang, Kyung-Il;Jean, Young-Hwa;Kim, Jae-Hoon
    • Korean Journal of Veterinary Research
    • /
    • v.47 no.4
    • /
    • pp.437-441
    • /
    • 2007
  • The cases of feline panleukopenia virus (FPLV) infection were diagnosed in three imported cats. All cats died within one week after mild emaciation, depression and anorexia. One cat showed yellowish watery diarrhea. At necropsy, all cats had segmental hemorrhage on the serosa and mucosa of the small intestine. Histopathologically, severe diffuse necro-hemorrhagic enteritis was observed in small intestine especially in jejunum and ileum. The crypts of Lieberkuhn were dilated and contained necrotic epithelia. Severely damaged epithelia of crypts were transformed into bizarre shapes. Multifocal lympholysis and lymphoid depletion were found in Peyer's patches and other lymphoid tissues. Direct fluorescent antibody (FA) test revealed the characteristic FPLV antigen in the cytoplasms of crypt epithelial cells. Based on the clinical signs, characteristic pathologic findings and FA test, these cases were diagnosed as FPLV infection. In our best knowledge, this study is the first case report for FPLV infection in imported cats in Korea.

Improved Focal Liver Lesion Detection by Increasing Flip Angle During Gadoxetic Acid-Enhancement in MRI (Gadoxetic acid 조영증강 자기공명영상에서 숙임각 변화에 따른 국소 간종양 검출능 비교)

  • Lee, SeJy;Kim, Young-Keun
    • Journal of radiological science and technology
    • /
    • v.38 no.2
    • /
    • pp.115-120
    • /
    • 2015
  • To study the differences of focal liver lesion image detection at 3 minute, 10 minute and 15 minute time points on gadoxetic acid (GA)'s enhanced MR imaging with a flip angle (FA) of $30^{\circ}$ compared with a $11^{\circ}$. The subjects were 69 patients evaluated with GA enhanced MR imaging with 3.0T MR scanner. The patients are total 35(23 men and 7 women at the mean age of 60.4 years), hepatocellular carcinoma(23) and metastsis(12) except for normal, cyst and hemangioma. After GA was injected, FA $11^{\circ}$ and $30^{\circ}$ images were obtained at 3 minute, 10 minute and 15 minute time points respectively. After quantitative and qualitative assessment of each image was done, statistical analysis was performed by using the independent sample T-test. From both quantitative and qualitative assessment of 3 minute and 10 minute MR images after the injection of GA, FA $30^{\circ}$ images was found to be superior than FA $11^{\circ}$, but there were no statistical significance. However, at 15 minute time point, Statistically significant FA $30^{\circ}$ image(p<0.05) was better than FA $11^{\circ}$ therefore, the FA $30^{\circ}$ improves the focal liver lesion detection. FA $30^{\circ}$ of MR image can detect liver lesion more sensitively than the existing $FA11^{\circ}$ image after GA contrast enhancement at 15 minute time point.

Condensation Heat Transfer Coefficients of R245fa on a Plain Tube (수평관에서 R245fa의 응축 열전달계수)

  • Shim, Yun-Bo;Park, Ki-Jung;Jung, Dong-Soo;Kim, Jong-Seong
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.19 no.8
    • /
    • pp.555-562
    • /
    • 2007
  • In this study, condensation heat transfer coefficients (HTCs) of R22, R134a, R245fa and R123 are measured on a horizontal plain tube. All data are taken at the vapor temperature of $39^{\circ}C$ with a wall subcooling temperature $3-8^{\circ}C$. Test results show the HTCs of newly developed alternative low vapor pressure refrigerant, R245fa, on a plain tube are 9.5% higher than those of R123 while they are 3.3% and 5.6% lower than those of R134a and R22 respectively. Nusselt's prediction equation for a plain tube underpredicts the data by 13.7% for all refrigerants while a modified equation yielded 5.9% deviation against all data. From the view point of environmental safety and condensation heat transfer, R245fa is a long term good candidate to replace R123 used in centrifugal chillers.

Validity and Reliability of Korean Version of the Family Management Measure (Korean FaMM) for Families with Children having Chronic Illness (만성질환 아동 가족의 한국어판 가족관리 측정도구(Family Management Measure [FaMM])의 타당도와 신뢰도)

  • Kim, Dong Hee;Im, Yeo Jin
    • Journal of Korean Academy of Nursing
    • /
    • v.43 no.1
    • /
    • pp.123-132
    • /
    • 2013
  • Purpose: To develop and test the validity and reliability of the Korean version of the Family Management Measure (Korean FaMM) to assess applicability for families with children having chronic illnesses. Methods: The Korean FaMM was articulated through forward-backward translation methods. Internal consistency reliability, construct and criterion validity were calculated using PASW WIN (19.0) and AMOS (20.0). Survey data were collected from 341 mothers of children suffering from chronic disease enrolled in a university hospital in Seoul, South Korea. Results: The Korean version of FaMM showed reliable internal consistency with Cronbach's alpha for the total scale of .69-.91. Factor loadings of the 53 items on the six sub-scales ranged from 0.28-0.84. The model of six subscales for the Korean FaMM was validated by expiratory and confirmatory factor analysis (${\chi}^2$ <.001, RMR<.05, GFI, AGFI, NFI, NNFI>.08). Criterion validity compared to the Parental Stress Index (PSI) showed significant correlation. Conclusion: The findings of this study demonstrate that the Korean FaMM showed satisfactory construct and criterion validity and reliability. It is useful to measure Korean family's management style with their children who have a chronic illness.

Determination of fracture toughness in concretes containing siliceous fly ash during mode III loading

  • Golewski, Grzegorz Ludwik
    • Structural Engineering and Mechanics
    • /
    • v.62 no.1
    • /
    • pp.1-9
    • /
    • 2017
  • This paper describes laboratory tests carried out to evaluate the influence of class F fly ash (FA) on fracture toughness of plain concretes, specified at the third model fracture. Composites with the additives of: 0%, 20% and 30% siliceous FA were analysed. Fracture toughness tests were performed on axial torsional machine MTS 809 Axial/Torsional Test System, using the cylindrical specimens with dimensions of 150/300 mm, having an initial circumferential notch made in the half-height of cylinders. The studies examined effect of FA additive on the critical stress intensity factor $K_{IIIc}$. In order to determine the fracture toughness $K_{IIIc}$ a special device was manufactured.The analysis of the results revealed that a 20% FA additive causes increase in $K_{IIIc}$, while a 30% FA additive causes decrease in fracture toughness. Furthermore, it was observed that the results obtained during fracture toughness tests are convergent with the values of the compression strength tests.

A Study on the Properties of High Fluidity Concrete Incorporating Lime Stone Powder and Fly Ash (석회석 미분말 및 플라이애쉬 치환율 변화에 따른 고유동 콘크리트의 특성에 관한 연구)

  • 조병영;윤길봉;황인성;한민철;윤기원;한천구
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2001.11a
    • /
    • pp.287-292
    • /
    • 2001
  • This paper investigates the properties of high fluidity concrete incorporating lime stone powder and fly ash. Lime stone powder(LSP) and fly ash(FA) contents are varied with. According to test results, as LSP and FA contents increase, fluidity, air content and placeability shows a declining tendency. For the temperature history, both LSP and FA have favorable effects on reducing hydration heat, moreover, LSP reduces hydration heat more than FA. LSP shows undesirable strength loss as its content increases. FA also decreases the strength at early age, but it enhances later age strength. Accordingly LSP is expected to improve the quality at fresh concrete and reduce hydration heat, while it causes strength loss.

  • PDF

Study of the Telemetry Ground Station for FA-50 Flight Test Instrumentation System (신규 형상에 따른 FA-50 지상계측 방안 연구)

  • Lee, Ju-Ha;Kim, Bo-Sung;Yoo, Byeong-Seon
    • Journal of the Korean Society for Aviation and Aeronautics
    • /
    • v.16 no.4
    • /
    • pp.20-25
    • /
    • 2008
  • The purpose of this study is leading to reduce the setup time and cost of the ground telemetry system for FA-50 program. And using the accumulated experience during T-50 and TA-50 development period, remove the risk of development and construct the optimal ground telemetry system for FA-50. For this study, collect the ground telemetry data of the T-50/TA-50, analyze the data and problems and then suggest the optimal telemetry ground system for FA-50.

  • PDF