• Title/Summary/Keyword: F0 Range

Search Result 1,449, Processing Time 0.031 seconds

Evaluation of gamma-ray and neutron attenuation properties of some polymers

  • Kacal, M.R.;Akman, F.;Sayyed, M.I.;Akman, F.
    • Nuclear Engineering and Technology
    • /
    • v.51 no.3
    • /
    • pp.818-824
    • /
    • 2019
  • In the present work, we determined the gamma-ray attenuation characteristics of eight different polymers(Polyamide (Nylon 6) (PA-6), polyacrylonitrile (PAN), polyvinylidenechloride (PVDC), polyaniline (PANI), polyethyleneterephthalate (PET), polyphenylenesulfide (PPS), polypyrrole (PPy) and polytetrafluoroethylene (PTFE)) using transmission geometry utilizing the high resolution HPGe detector and different radioactive sources in the energy range 81-1333 keV. The experimental linear attenuation coefficient values are compared with theoretical data (WinXCOM data). The linear attenuation coefficient of all polymers reduced quickly with the increase in energy, at the beginning, while decrease more slowly in the region from 267 keV to 835 keV. The effective atomic number of PVDC and PTFE are comparatively higher than the $Z_{eff}$ of the remaining polymers, while PA-6 possesses the lowest effective atomic number. The half value layer results showed that PTFE ($C_2F_4$, highest density) is more effective to attenuate the gamma photons. Also, the theoretical results of macroscopic effective removal cross section for fast neutrons ($\sum_{R}$) were computed to investigate the neutron attenuation characteristics. It is found that the $\sum_{R}$ values of the eight investigated polymers are close and ranged from $0.07058cm^{-1}$ for PVDC to $0.11510cm^{-1}$ for PA-6.

A Study on the Symptom Distress and Suffering of Five Major Cancer Patients (암질병에 따른 암환자의 불편감과 고통에 관한 연구)

  • Kwon, Mi-Hyoung;Kim, Boon-Han
    • Asian Oncology Nursing
    • /
    • v.3 no.2
    • /
    • pp.145-154
    • /
    • 2003
  • Purpose: The study was to furnish basic raw materials that evaluate the efficacy of meatal care according to the form and the relative importance of symptom distress which most of cancer sufferers have been experienced. For that, an investigation of five diverse major cancer symptom distress made a comparison between symptom distress and degree of suffering. Method: Study subjects were 138 inpatients with stomach cancer, lung cancer, hepatocellular carcinoma(HCC), large intestine cancer and breast cancer, except those in the terminal-stage, in 'H' university hospital in Seoul and 'K' center in Ilsan gathered from November 20, 2002 to February 20, 2003. To measure the correlation between feeling of discomfort and agony caused by cancer, 5 point scale (from zero to four), stood on the basis of Symptom Distress Scale (SDS, Rodes & Watson, 1987), was used for this study and the Cronbach's coefficient alpha was 0.95. Accumulated data was analyzed with SPSS 10.0 for window, also used by ANOVA and Duncan's Multiple Range Test. Pearson's Correlation Analysis. Results: 1. Symptom distress of cancer patients was noted and defined in their severity-fatigue, anorexia, pain, depression, dyspepsia, changing appearance and nausea. The degree of symptom distress was fatigue, dyspepsia, depression, anorexia, pain, changing appearance and the degree of suffering was nausea, pain, anorexia, dyspepsia, vomiting, breathing difficulty, changing appearance and fatigue. 2. Examining the difference of degree of symptom distress in each cancer cases, it takes the precedence of them. First, in case of stomach cancer, depression, pain, vomiting and nausea were shown in sequence. In case of lung cancer depression, pain, sleeping problem, anxiety, changing appearance, inattentiveness and vomiting were showed in sequence, depression, changing appearance, sleeping problem, pain in case of HCC, depression, pain in case of large intestine cancer and lastly in case of breast cancer changing appearance, depression, pain and anxiety were shown in sequence. The category of the degree of symptom distress that has a signifiant difference was anorexia, activity discomfort, fatigue, constipation or diarrhea, breathing difficulty, dyspepsia, caughing, fever or chillness, scotoma and urinary disorder. Verifying the highest degree of symptom distress in each cancer cases, anorexia was 1.94(F=4.00, p<.01) in stomach cancer, activity discomfort was 0.97(F=3.08, p<.01) in lung cancer and HCC, fatigue was 2.32(F=4.64, p<.01) in HCC, constipation or diarrhea was 1.83(F=22.31, p<.001) in large intestine cancer, breathing difficulty was 1.83(F=4.00, p<.01) in lung cancer, dyspepsia was 2.69(F=9.98, p<.001) in stomach cancer, coughing was 1.53(F=20.49, p<.001) in lung cancer, fever or chillness was 1.23(F=6.88, p<.001) in lung cancer, scotoma was 1.20(F=3.02, p<.05) in lung cancer and urinary disorder was 1.54(F=11.56, p<.001) in HCC. 3. Examining the difference degree of suffering on cancer cases, the result was as follows; depression of lung cancer was 1.17(F=3.76, p<.01), anorexia of stomach cancer was 1.61(F=3.89, p<.01), constipation or diarrhea of large intestine cancer was 1.42(F=10.43, p<.001), changing appearance of breast cancer was 1.65(F=5.43, p<.001), breathing difficulty of lung cancer was 2.27(F=18.57, p<.001), dyspepsia of stomach cancer was 1.97(F=13.56, p<.001), coughing of lung cancer was 1.70(F=22.07, p<.001), fever or chillness of lung cancer was 1.13(F=4.41, p<.01), scotoma of lung cancer was 0.87(F=3.34, p<.05), anxiety of lung cancer was 0.87(F=4.50, p<.001) and urinary disorder of HCC was 1.43(F=16.71, p<.001). 4. In consequence, comparing between symptom distress and degree of suffering on cancer patients undergoing chemotherapy, lung cancer patients showed the highest feeling of discomfort following stomach cancer, HCC, breast cancer and large intestine cancer(F=2.88, p<.05). On those undergoing radiotherapy, lung cancer, HCC, breast cancer, large intestine cancer was in sequence(F=3.78, p<.05) and those resisting radiotherapy, lung cancer, HCC, stomach cancer, large intestine cancer and breast cancer was in sequence(F=2.72, p<.05). 5. Correlation between symptom distress and degree of suffering on cancer patients was generally significant. Conclusion: this study not only defines a significant correlation between symptom distress and degree of suffering but also proffers basic data to evaluate the efficient meatal care depending upon diverse spectrums of symptom distress and degree of suffering.

  • PDF

Layer Thickness-dependent Electrical and Optical Properties of Bottom- and Top-emission Organic Light-emitting Diodes

  • An, Hui-Chul;Na, Su-Hwan;Joo, Hyun-Woo;Kim, Tae-Wan
    • Transactions on Electrical and Electronic Materials
    • /
    • v.10 no.1
    • /
    • pp.28-30
    • /
    • 2009
  • We have studied organic layer-thickness dependent electrical and optical properties of bottom- and top-emission devices. Bottom-emission device was made in a structure of ITO(170 nm)/TPD(x nm)/$Alq_3$(y nm)/LiF(0.5 nm)/Al(100 nm), and a top-emission device in a structure of glass/Al(100 nm)/TPD(x nm)/$Alq_3$(y nm)/LiF(0.5 nm)/Al(25 nm). A hole-transport layer of TPD (N,N'-diphenyl-N,N'-di(m-tolyl)-benzidine) was thermally deposited in a range of 35 nm and 65 nm, and an emissive layer of $Alq_3$ (tris-(8-hydroxyquinoline) aluminum) was successively deposited in a range of 50 nm and 100 nm. Thickness ratio between the hole-transport layer and the emissive layer was maintained to be 2:3, and a whole layer thickness was made to be in a range of 85 and 165 nm. From the current density-luminance-voltage characteristics of the bottom-emission devices, a proper thickness of the organic layer (55 nm thick TPD and 85 nm thick $Alq_3$ layer) was able to be determined. From the view-angle dependent emission spectrum of the bottom-emission device, the peak wavelength of the spectrum does not shift as the view angle increases. However, for the top-emission device, there is a blue shift in peak wavelength as the view angle increases when the total layer thickness is thicker than 140 nm. This blue shift is thought to be due to a microcavity effect in organic light-emitting diodes.

A Design of 1.42 - 3.97GHz Digitally Controlled LC Oscillator (1.42 - 3.97GHz 디지털 제어 방식 LC 발진기의 설계)

  • Lee, Jong-Suk;Moon, Yong
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.49 no.7
    • /
    • pp.23-29
    • /
    • 2012
  • The LC-based digitally controlled oscillator (LC-DCO), a key component of the all digital phase locked loop (ADPLL), is designed using $0.18{\mu}m$ RFCMOS process with 1.8 V supply. The NMOS core with double cross-coupled pair is chosen to realize wide tuning range, and the PMOS varactor pair that has small capacitance of a few aF and the capacitive degeneration technique to shrink the capacitive element are adopted to obtain the high frequency resolution. Also, the noise filtering technique is used to improve phase noise performance. Measurement results show the center frequency of 2.7 GHz, the tuning range of 2.5 GHz and the high frequency resolution of 2.9 kHz ~7.1 kHz. Also the fine tuning range and the current consumption of the core could be controlled by using the array of PMOS transistors using current biasing. The current consumption is between 17 mA and 26 mA at 1.8V supply voltage. The proposed DCO could be used widely in various communication system.

Thermo-Mechanical Fatigue Crack Propagation Behaviors of 1.5Cr-0.67Mo-0.33V Alloy (1.5Cr-0.67Mo-0.33V강의 열피로 크랙전파 거동)

  • 송삼홍;강명수
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.19 no.9
    • /
    • pp.2133-2141
    • /
    • 1995
  • The thermo-mechanical fatigue tests were performed on the specimens extracted from 1.5Cr-0. 67Mo-0.33V alloy. The characteristics of thermo-mechanical fatigue crack propagation were examined and reviewed in view of fracture mechanics. The results obtained from the present study are summarized as follows : (1) The propagation characteristics of isothermal low-cycle fatigue crack are dominated by .DELTA.J$_{f}$ in case of PP waveform, and .DELTA.J$_{c}$ in case of CP waveform. (II)The propagation characteristics of thermo-mechanical fatigue crack are dominated by .DELTA.J$_{c}$ for in-phase case, and by .DELTA.J$_{c}$ for out-of-phase. The present results were in good agreement with the equation of propagation law for isothermal low-cycle fatigue crack in case of thermo-mechanical fatigue.tigue.e.

Nickel(II) Determination by Spectrophotometry Coupled with Preconcentration Technique in Water and Alloy Samples

  • Rekha, Dasari;Kumar, Jengiti. Dilip;Jayaraj, Bellum;Lingappa, Y.;Chiranjeevi, Pattium
    • Bulletin of the Korean Chemical Society
    • /
    • v.28 no.3
    • /
    • pp.373-378
    • /
    • 2007
  • A micro organism Agrobacterium tumifacient as an immobilized cell on a solid support was presented as a new biosorbent in a simple and sensitive spectrophotometry determination of Ni(II) in various samples using 4-hydroxy benzaldehyde-4-bromophenyl hydrazone as a color developing agent (λmax 497 nm) at pH 4.0 ± 0.2. Beer's law was obeyed over the range of 0.01-0.1 μg L-1. The molar absorptivity and Sandell's sensitivity were 1.285 × 105 L mol-1cm-1 and 0.007245 μg cm-2 respectively. Under these conditions, the preconcentration factor obtained was 82, and the detection limit achieved was 0.05 μg L-1. The detailed study of various interfering ions made the method more sensitive and selective. The recovery of Ni(II) from various samples range from 97.75 to 99.35%. The present method was successfully applied for the determination of Ni(II) in spiked, natural water and alloy samples. The proposed method was compared with reported methods in terms of Student's ‘t'-test and Variance ratio ‘f'-test which indicates that there is no significant difference between proposed and literature method at 95% confidence level.

Effects of Alkalinity on the Nitrification Capability of Nonwoven Fabric Filter Bioreactor (부직포 여과막 생물반응조에서 알칼리도가 질산화 성능에 미치는 영향)

  • Bae, Min-Su;Ahn, Yoon-Chan;Jang, Myung-Bae;Cho, Yun-Kyung;Cho, Kwang-Myeung
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.29 no.7
    • /
    • pp.783-792
    • /
    • 2007
  • To investigate the effects of alkalinity on the nitrification capability of the nonwoven fabric filter bioreactor(NFBR), an experiment was performed for 641 days at a hydraulic retention time of approximately 11 hours by changing the influent concentration of $NH_3-N$ from 54 mg/L to 1,400 mg/L and alkalinity from 43 mg/L to 10,480 mg/L. The MLSS concentration reduced from an initial value of 2,650 mg/L down to 830 mg/L, then increased up to 8,340 mg/L. Though the volumetric loading rate varied in a range of $0.120\sim3.130$ kg $NH_3-N/m^3-day$, the F/M ratio showed a narrow range of $0.067\sim0.414$ kg $NH_3-N/kg$ MLSS-day. The average nitrification efficiency at each experimental stage resulted in the range of $35.2\sim100%$, and the maximum nitrification rate was 2.970 kg $N/m^3-day$ or 0.489 g N/g MLVSS-day. The nitrifiers' fraction of the MLVSS increased up to 100% from an initial value of 7.1% and the biofilm formed on the nonwoven fabric filter showed a very low nitrifiers' fraction of mere 2.2%. The growth yield of the MLSS and the alkalinity consumption rate were computed to be 0.117 g VSS/g N removed and 7.08 g alkalinity/g $NO_x^--N$ produced, respectively. Results of the research suggest that NFBR could be an adequate process for nitrification of wastewaters with high ammonia concentrations.

Optimization of Process Variables for Grinding of Ibuprofen using Response Surface Methodology (반응표면분석법을 이용한 이부프로펜의 분쇄공정변수의 최적화)

  • Sim, Chol-Ho
    • Korean Chemical Engineering Research
    • /
    • v.51 no.6
    • /
    • pp.685-691
    • /
    • 2013
  • Ibuprofen, non-steroidal anti-inflammatory drugs; NSAIDs, is a highly crystalline substance with the pharmaceutical properties of poor solubility and low bioavailability. The size reduction of ibuprofen is needed to improve the solubility. The objective of this study is to optimize the grinding condition of ibuprofen. Grinding of ibuprofen was carried out using a planetary mill. Grinding parameters were optimized using Box-Behnken experimental design method. The physical characteristics of ground ibuprofen were investigated for the particle size by particle size analyzer, for the crystal size by X-ray diffraction (XRD), and for the tensile strength by tensile/compression tester. The optimum conditions for the milling of ibuprofen were 290 rpm of the revolution number of mill, 24.6 g of the weight of sample, and 10 minutes of grinding time. The measured value of the particle size of ground ibuprofen at these optimum conditions was $13.5{\mu}m$. The results showed that the crystal size of ibuprofen was reduced by the planetary milling process. In case the relative density of the tablets formulated of ground ibuprofen was range of 0.85~0.90, the tensile strength of them was range of 1$2{\sim}14Kg_f/cm^2$.

A Novel System with EMG-controlled FES Enhanced Gait Function and Energy Expenditure for Older Adults

  • Jang-hoon Shin;Hye-Kang Park;Joonyoung Jung;Dong-Woo Lee;Hyung cheol Shin;Hwang-Jae Lee;Wan-hee Lee
    • Physical Therapy Rehabilitation Science
    • /
    • v.13 no.2
    • /
    • pp.152-162
    • /
    • 2024
  • Objective: This study was conducted to analyze the effect of wearable Electromyography-controlled functional electrical stimulation (EMG-controlled FES) System on Gait Function and cardiopulmonary metabolic efficiency during walking in older adults. Design: Cross-section study Methods: Total 22 older adult participants suitable to selection criteria of this study participated in this study. The EMG-controlled FES System, which functions as a wearable physical activity assist FES system was used. All participations performed randomly assigned two conditions (Non-FES assist [NFA], FES assist [FA]) of walking. In all conditions, spatio-temporal parameters and kinematics and kinetics parameters during walking was collected via 3D motion capture system and 6 minutes walking test (6MWT) and metabolic cost during walking and stairs climbing was collected via a portable metabolic device (COSMED K5, COSMED Srl, Roma, Italy). Results: In Spatio-temporal parameters aspects, The EMG-controlled FES system significantly improved gait functions measurements of older adults with sarcopenia at walking in comparison to the NFA condition (P<0.05). Hip, knee and ankle joint range of motion increased at walking in FA condition compared to the NFA condition (P<0.05). In the FA condition, moment and ground reaction force was changed like normal gait during walking of older adults in comparison to the NFA condition (P<0.05). The EMG-controlled FES system significantly reduced net cardiopulmonary metabolic energy cost, net energy expenditure measurement at stairs climbing (P<0.05). Conclusions: This study demonstrated that EMG-controlled FES is a potentially useful gait-assist system for improving gait function by making joint range of motion and moment properly.

Synthesis and Micellar Characterization of CBABC Type PLGA-PEO-PPO-PEO-PLGA Pentablock Copolymers

  • Seong, Haseob;Cho, Eun-Bum;Oh, Joongseok;Chang, Taihyun
    • Bulletin of the Korean Chemical Society
    • /
    • v.35 no.8
    • /
    • pp.2342-2348
    • /
    • 2014
  • Poly(lactic-co-glycolic acid) (PLGA) were grafted to both ends of Pluronic$^{(R)}$ F68 ($(EO)_{75}(PO)_{30}(EO)_{75}$) triblock copolymer to produce poly{(lactic acid)$_m$-co-(glycolic acid)$_n$}-b-poly(ethylene oxide)$_{75}$-b-poly(propylene oxide)$_{30}$-b-poly(ethylene oxide)$_{75}$-b-poly{(lactic acid)$_m$-co-(glycolic acid)$_n$} (PLGA-F68-PLGA) pentablock copolymers. Molecular weights of PLGA blocks were controlled and five kinds of pentablock copolymers with different PLGA block lengths were synthesized using in-situ ring-opening polymerization of D,L-lactide and glycolide with tin(II) 2-ethylhexanoate ($Sn(Oct)_2$) catalyst. PLGA-F68-PLGA pentablock copolymers were characterized by $^1H$- and $^{13}C$-NMR, GPC, and TGA. The numbers (2m, 2n) of repeating units for lactic acid and glycolic acid inside PLGA segments were obtained as (48, 17), (90, 23), (125, 40), (180, 59), and (246, 64), with $^1H$-NMR measurement. From NMR data, the resultant molecular weights were determined in the range of 12,700-29,700, which were similar to those obtained from GPC. Polydispersity index was increased in the range of 1.32-1.91 as the content of PLGA blocks increased. TG and DTG thermograms showed discrete degradation traces for PLGA and F68 blocks, which indicate the weight fractions of PLGA blocks in pentablock copolymers can be calculated by TG profile and it is possible to remove PLGA block selectively. Hydrodynamic radius and radius of gyration of pentablock copolymer micelle were obtained in the range of 46-68 nm and 31-49 nm, respectively, in very dilute (i.e. 0.005 wt %) aqueous solution of THF:$H_2O$ = 10:90 by volume at $25^{\circ}C$.