• Title/Summary/Keyword: F0 Range

Search Result 1,444, Processing Time 0.029 seconds

A Study on the Dielectric Properties of Silicone Rubber Filled with Silica (실리카 충진된 실리콘 고무의 유전 특성에 관한 연구)

  • Lee, Sung Ill
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.26 no.11
    • /
    • pp.810-815
    • /
    • 2013
  • In this study, the capacitance and dielectric loss tangent of the silicone rubber which is combined with filler (30 phr~50 phr) have been measured on the range of 100 Hz~100 kHz and $30{\sim}170^{\circ}C$. It was found that when the frequency is 0.1 kHz~100 kHz and the silicone rubber is combined with 30 phr to 50 phr of filler, the capacitance of silicone rubber has increased by about 28.6 pF to 33 pF in 30 phr of filler, about 20 pF to 46.1 pF in 40 phr of filler and about 36.4 pF to 44 pF in 50 phr of filler. It seems that the volume of dielectric loss has gradually increased due to the temperature rise and the rotating of dipole in electric field through the electric dipole generated by the Si-O group which is induced by adding of filler, or the carbonyl group which is caused by oxidation. It seems that the dielectric dispersion in 0.1 kHz is caused by molecular motion of Siloxane group in main chain, and the dielectric dispersion in 10 kHz is caused by molecular motion of Methyl group in side chain.

Effects of Knee Balance Taping Therapy on Knee Pain and Range of Motion in the Elderly (슬관절 밸런스 테이핑 요법이 노인의 무릎 통증과 관절가동범위에 미치는 효과)

  • Kim, Doomi;Kim, Bokyoung;Kwon, Oh-Yun;Park, Kyungsook
    • Journal of Digital Convergence
    • /
    • v.16 no.6
    • /
    • pp.213-222
    • /
    • 2018
  • This study purposed to verify the effects of knee balance taping therapy on knee pain and knee range of motion in the elderly with knee pain. The Quasi-experimental design, nonequivalent control group pretest-posttest was used in this study. Data collected from December 5 to 10, 2014. The participants were older than 60 with knee pain visiting senior community centers. Non-medicated elastic tapes were applied around the knee in the experimental group(n=21) and were not applied in the control group(n=19). Knee pain and range of motion were measured 3 times (before, after 1 hour, after 24 hours). Data were analyzed using ${\chi}^2$ test, Fisher's exact test, Mann-Whitney test, t-test, Repeated measure ANOVA with the SPSS version 21.0 program. The experimental group showed significantly decreased knee pain (F=34.03, p<.001) and increase in knee range of motion (F=7.83, p=.006). The results of this study confirm that knee balance taping therapy is an effective intervention for reducing pain and improving range of motion in elderly with knee pain.

Mode of Occurrences and Depositional Conditions of Arsenopyrite from the Yeonhwa 1 Mine, Korea (연화 제1광산에서의 유비철석의 산상과 배태 조건)

  • Lee, Young-Up;Chung, Jae-Il
    • Journal of the Mineralogical Society of Korea
    • /
    • v.16 no.1
    • /
    • pp.1-17
    • /
    • 2003
  • The chemical composition of the arsenopyrite Ib adjoining“triple mutual contact”arsenopyrite + pyrite + hexagonal pyrrhotite may serve as a useful geothermometer in Stage II. In this study it corresponds to temperature T=33$0^{\circ}C$ and f( $S_2$)=10$^{-9.5}$ atm. And the pyrite-hexagonal pyrrhotite buffer curve indicates the probable range of the two variables; T= 315∼345$^{\circ}C$, and f( $S_2$)=10$^{-1}$0.5/∼10$^{-9}$ atm. The present antimony-bearing arsenopyrite (arsenopyrite Ic) is characterized by relatively high content of antimony, ranging from 4.95 to 8.91 percent Sb by weight and excess of iron and deficiency of anions are evident. Such a high antimonian arsenopyrite has never been known within single grain. But being the high content of antimony as in the arsenopyrite Ic, it does not serve as a geothermometer. The results of microprobe analyses for four pairs of asenopyrite and sphalerite in Stage III indicate the temperature range from 310 to 34$0^{\circ}C$, and sulphur fugacity range from 10$^{-10}$ ∼10$^{-9}$ atm. These values seem to correspond with those inferred from the Fe-As-S system.m..

Usefulness of $^{18}F$-FDG PET/CT in Locoregional Recurrence of Differentiated Thyroid Cancer: Comparison PET/CT to PET and Neck Ultrasonography for Biopsy-proven Lesions (갑상선유두암 재발 진단에서 $^{18}F$-FDG PET/CT와 경부초음파검사 병용의 유용성: PET, 경부초음파검사 그리고 혈청 티로글로불린 (thyroglobulin)의 비교)

  • Kim, Kun-Ho;Shong, Min-Ho;Seo, Young-Duk;Kim, Seong-Min
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.43 no.5
    • /
    • pp.411-420
    • /
    • 2009
  • Purpose: The aim of this study was to investigate the usefulness of $^{18}F$-FDG PET/CT with neck ultrasonography (neck US) in patients with recurrent, papillary thyroid cancer. Material and methods: This retrospective study (December 2006 to April 2008) enrolled sixty-one patients (ninety-one lesions) who underwent high-dose $^{131}I$-ablation therapy after total thyroidectomy, and evaluated recurred papillary thyroid cancer. All lesions were confirmed by histopathology and compared histopathologic findings to PET, PET/CT, and neck US findings. Results: In sixty-one patients (57 women, 4 men; age range, 24-81 years, mean 49 years; 61 papillary carcinomas), the sensitivity, specificity, accuracy of $^{18}F$-FDG PET/CT was 87.2%, 64.0%, 78.1% on a patient basis and 92.3%, 66.7%, 80.9% on a lesion basis, respectively. The sensitivity, specificity, accuracy of $^{18}F$-FDG PET was 71.8% (p=0.03), 59.0% (p=1.00), 67.2% (p=0.03) on a patient basis and 78.8% (p<0.01), 64.1% (p=1.00), 72.5% (p=0.02) on a lesion basis, respectively. The sensitivity, specificity, accuracy of neck US was 71.1% (p=0.07), 52.2% (p=0.75), 63.9% (p=0.05) on a patient basis and 71.2% (p<0.01), 61.5% (p=1.00), 67.0% (p=0.06) on a lesion basis, respectively. Combined $^{18}F$-FDG PET/CT with neck US improved the sensitivity, specificity, accuracy to 94.7% (p=0.50), 82.6% (p=0.13), 90.2% (p=0.03) on a patient basis and 96.2% (p=0.50), 89.7% (p<0.01), 93.4% (p<0.01) on a lesion basis, respectively. Conclusion: $^{18}F$-FDG PET/CT demonstrated significantly higher sensitivity than neck US for the detection of recurred papillary thyroid cancer lesions. Furthermore, combined $^{18}F$-FDG PET/CT with neck US showed more improved sensitivity, specificity, accuracy for diagnosis of recurrent papillary thyroid cancer.

Quality Characteristics of Yogurt Supplemented with Angelica gigas Nakai Leaf Extract (참당귀잎 추출물을 첨가한 요구르트의 품질 특성)

  • Kim, JiYoun;Han, JeongA;Kang, Hyeoncheol;Lee, Jaehak;Kim, Hee-Yeon;Lim, Young-Soon
    • Journal of Dairy Science and Biotechnology
    • /
    • v.37 no.4
    • /
    • pp.237-246
    • /
    • 2019
  • In this study, quality characteristics of yogurt supplemented with Angelica gigas Nakai leaf extract were examined. The pH of the yogurt ranged from 4.40 to 4.45 and the titratable acidity ranged from 0.96% to 0.98%. The viscosity tended to decrease with the addition of the Angelica gigas Nakai leaf extract, but did not affect stability during storage. In the range of 0.1% to 0.3%, lactic acid bacteria were present in the range of 1.9×109 to 3.2×109 CFU/mL. The decursin content in yogurt was quantitatively analyzed, depending on the addition of 0.1% to 0.3% of Angelica gigas Nakai leaf extract and was found to be 0.26 ㎍/g, 15.23 ㎍/g, and 23.57 ㎍/g respectively. Organic acid showed the highest generation of lactic acid. The antioxidant properties of yogurt were shown to increase with the addition of the Angelica gigas Nakai leaf extract. The sensory score of yogurt supplemented with 0.1% of the Angelica gigas Nakai leaf extract was highly valued, at a level similar to that of plain yogurt. Yogurt supplemented with 0.2% of the extract was rated above the normal score of 6.31 to 6.50. As shown by the results, the optimal concentration of Angelica gigas Nakai leaf extract for addition to yogurt was within 0.2%.

Analysis of Accelerated Soft Error Rate for Characteristic Parameters on Static RAM (정적 RAM 특성 요소에 의한 소프트 에러율의 해석)

  • Gong, Myeong-Kook;Wang, Jin-Suk;Kim, Do-Woo
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.55 no.4
    • /
    • pp.199-203
    • /
    • 2006
  • This paper presents an ASER (Accelerated Soft Error Rate) integral model. The model is based on the facts that the generated EHP/s(electron hole pairs) are diminished after some residual range of the incident alpha particle, where residual range is a function of the incident angle and the capping layer thickness over the semiconductor junction. The ASER is influenced by the flux of the alpha particles, the junction area ratio, the alpha particle incident angle when the critical charge is same as the collected charge, and the sizes of the alpha source and the chip. The model was examined with 8M static RAM samples. The measured ASER data showed good agreement with the calculated values using the model. The ASER decreased exponentially with respect to the operational voltage. As the capping layer thickness increases up to $16{\mu}m$, the ASER increases, and after that thickness, the ASER decreases. The ASER increased as the depth of BNW increased from $0{\mu}m\;to\;4{\mu}m$. and then saturated. The ASER decreased as the node capacitance increased from 2fF to 5fF.

A Study on the Health Promoting Behaviors Depending on the Response Patterns of HLOC in Korean Adults (한국 성인의 건강통제위 반응유형별 건강증진행위)

  • Gu, Mee-Ock;Eun, Young
    • Journal of Korean Academy of Nursing
    • /
    • v.28 no.3
    • /
    • pp.739-750
    • /
    • 1998
  • The purpose of this study was to identify the response patterns of Health Locus of Control (HLOC) and to analysis of the health promoting behaviors depending on the response patterns of HLOC in Korean adults. The sample was composed of 300 healthy adults ranged from twenties to seventies. In data analysis, SPSS PC/sup +/ program was utilized for descriptive statistics, pearson correlation, ANOVA and cluster analysis. The results of the study were as follows : 1. The average scores of HLOC in Korean were HLOC-I : 24.12(range 6-30), HLOC-P : .21.72, HLOC-C : 17.46. 2. The total mean score of the health promoting behavior scale was 2.50 (range 1-4), and the mean scores on the subscales were ; self actualization 2.60, health responsibility 2.14, exercise 2.28, nutrition 3.16, interpersonal support 2.74, stress management 2.15. 3. The HLOC-I and health promoting behavior were correlated positively(r =0.184, p=0.001), and the HLO-C and the health promoting behavior were correlated negatively(r=-0.102, p=0.039). The HLOC-P and the health promoting behavior weren't correlated in the level of statistical significance. 4. The response patterns of HLOC in Korean adults were identified 6 types, such as pure internal, pure chance, believers in control, yea sayer, nay sayer, and complex control. The type of believers in control and the type of yea sayer were subdivided in two different types. The believers in control was the largest group(33.67%), and yea sayer was the next large group(26.33%). The pure chance and the complex control type was the smallest groups. 5. There was a significant difference in health promoting behavior depending on the response patterns of HLOC(F=2.67, p=0.010). There were also significant differences in 4 subscales of health promoting behavior : self actualization(F=3.12, P=0.003), health responsibility(F=2.15, P=0.038), nutrition(F=5.08, p=0.000), and interpersonal support(F=2.26,p=0.029). These results suggest that the response patterns of HLOC is the important factor to predict the level of health promoting behavior in Korean adults.

  • PDF

A Study on the Factors Affecting Asbestos Exposure Level from Asbestos Abatement in Building Demolition Sites (석면 해체·제거시 공기 중 노출수준과 영향요인)

  • Kim, Ji-Yeong;Lee, Song-Kwon;Lee, Jeong Hee;Lim, Mu Heok;Kang, Sungwook;Phee, Young Gyu
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.19 no.1
    • /
    • pp.8-15
    • /
    • 2009
  • This study was examined to find out asbestos exposure level the factors which affected the level at asbestos abatement sites. We visited a total of thirteen building demolition sites(3 apartments, 3 schools, 4 stores, and 3 houses) were visited to collect samples and related data from August to November, 2006. The results of this study were as follows 1. The results of an analysis of bulk samples to identify types of asbestos at the asbestos abatement sites showed that the kinds of the asbestos detected were chrysotile by 50.0%, were tremolite by 2.6%, and were the contents of chrysotile by 3 to 20%. 2. The geometric mean concentration of asbestos was 0.007 f/cc(range 0.001-0.34 f/cc) and its geometric standard deviation was 5.83. Of the samples, however, 12 exceeded the Korean Occupational Exposure Limit(0.1f/cc). 3. Of the materials, textile material had the highest concentration with geometric mean of 0.016 f/cc. When asbestos-containing materials were removed using T type tools, the geometric mean concentration of asbestos was 0.061 f/cc. The level by this method was much higher than by other removal methods. In analysis by the type of building, the geometric mean concentration of asbestos in stores was 0.042 f/cc and was higher than in other buildings. 4. The Poisson regression analysis was applied to find out the factors that affect the airborne asbestos concentration. As a result of the analysis, removal using a T type tool was the most important factor affecting the asbestos concentration(p<0.01). In conclusion, the airborne asbestos concentration(geometric mean) in asbestos abatement sites was 0.007 f/cc(0.001~0.34 f/cc), and 12(14.6%) of all samples were over the 0.1 f/cc. These results showed that asbestos abatement workers have been exposed to the high level of airborne asbestos because they have not been keeping asbestos removal rule. In accordance with increases of the number of building demolition sites, the better government regulation on asbestos abatement methods should be made and be performed well at building demolition sites.

Effect of $Al_2O_3$ Additives on Microwave Dielectric Properties of (Ba,Ca,Mg)-$Nd_2O_3-TiO_2+10wt%Bi_2O_3$ Ceramics ($Al_2O_3$ 첨가가 (Ba,Ca,Mg)-$Nd_2O_3-TiO_2+10wt%Bi_2O_3$ 세라믹의 마이크로파 유전특성에 미치는 영향)

  • 최지원;강종윤;하종윤;윤석진;김현재;정현진;윤기현
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1999.05a
    • /
    • pp.653-656
    • /
    • 1999
  • Effect of $Al_2O_3$ Additives on Microwave Dielectric Properties of $0.15(Ba_{0.85}Ca_{(0.15-y)}Mg_y)$-0.125 $Nd_2O_3-0.60TiO_2+10wt%Bi_zO_3$ (y=0.05, 0.08) Ceramics was investigated. To control of $\tau\;{f}$ on microwave dielectric properties of $0.15(Ba_{0.85}Ca_{(0.15-y)}Mg_y)$-0.125 $Nd_2O_3-0.60TiO_2+10wt%Bi_zO_3$ ceramics $Al_2O_3$ was doped in the composition range of 0 to 0.15 wt%. As a result, dielectric constant was decreased from 94 to 80 but $Q\cdot{f}_0$ value was increased from 4980 to 5210 GHz and temperature coefficient of resonant frequency can be controlled from +9 to -10$ppm^\circ{C}$ as an increase of$Al_2O_3$ doping concentration. Especially, a new microwave dielectric material having $\varepsilon\;_r=84,\;Q\cdot{f}_0=5120\;GHz\;and\;\tau_f=0\;ppm/^\circ{C}$ was obtained at $Al_2O_3$ doping concentration of 0.08 wt%.

  • PDF

The Structural and Microwave Dielectric Properties of the BMT Ceramics with Sintering Temperature and BCN Composition Ratio (소결온도와 BCN 초성에 따른 BMT 세라믹스의 구조 및 마이크로파 유전특성)

  • Choe, Ui-Seon;Lee, Mun-Gi;Ryu, Gi-Won;Lee, Seong-Gap;Lee, Yeong-Hui
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.51 no.7
    • /
    • pp.305-310
    • /
    • 2002
  • The microwave dielectric properties of Ba(Mg$_{1}$3/Ta$_{2}$3/O$_3$-Ba(Co$_{1}$3/Nb$_{2}$3/O$_3$[BMT-BCN] ceramics were investigated. The specimens were prepared by the conventional mixed oxide method with the sintering temperature of 15$25^{\circ}C$~1575$^{\circ}C$. It was found that Ba(Mg$_{1}$3/Ta$_{2}$3/O$_3$[BMT] and BCN formed a solid solution with complex perovskite structure. As increasing the mole fraction of BCN, dielectric constant increased while the temperature coefficient of resonant frequency was changed from positive to negative value. The highest value of quality factor, Q$\times$f$_{0}$=138,205GHz, obtained in the 0.9BMT-0.1BCN ceramics sintered at 1575$^{\circ}C$. In the range of x$\geq$0.4, the dielectric constant was about 30. The 0.55BMT-0.45BCN ceramics sintered at 15$25^{\circ}C$ for 5 hours showed the microwave dielectric properties of $\varepsilon$$_{r}$=30.21, Q$\times$f$_{0}$=85,789GHz and $\tau$$_{f}$=2.9015ppm/$^{\circ}C$.EX>.