• Title/Summary/Keyword: F0 Range

Search Result 1,449, Processing Time 0.03 seconds

Association of Interleukin-27 rs 153109 Single Nucleotide Polymorphism with Spontaneous Resolution of Hepatitis C Virus - Genotype 4a Infection in Egyptian Patients

  • Fawzy, Mariam M;Wahid, Ahmed;Nazmy, Maiiada H;Hashem, Mohamed;Waked, Imam;Abdelwahab, Sayed F
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.17 no.4
    • /
    • pp.2093-2097
    • /
    • 2016
  • Background: HCV is a major global health problem. IL-27 is a member of the IL-6/IL-12 cytokine family with a broad range of anti-inflammatory properties. Recent studies highlighted the effect of a SNP in the IL-27 promoter region on modulating the progression of infectious diseases and individual responses to therapy. Aim of the work: The present study investigated the potential role of (-964 A/G) SNP in the promoter region of IL-27p28 gene (alleles rs153109) on the outcome of HCV infection among genotype 4a infected patients. Materials and Methods: HCV genotyping confirmed that all of the HCV-infected patients had genotype 4a infection. Genomic DNA was extracted from 111 patients with chronic HCV infection, 42 spontaneous resolvers (SR) and 16 healthy controls. IL- 27p28.rs153109 genotyping was assessed using PCR-RFLP then confirmed by DNA sequencing. Results: The frequency of IL-27-p28.rs153109AA, AG, and GG genotypes among chronically infected subjects were 74.8 %, 25.2%, and 0% while among the SR, they were 57.1%, 35.7%, and 7.14%, respectively. Our data show the unique presence of G/G genotype in the SR group (3 patients; 7.14%). Moreover, the "G" allele frequencies among chronic and resolved subjects were 12.6% and 25.0%, respectively (p=0.0136). Importantly, subjects with the GG genotype were more likely to clear their HCV infection than those with the AA genotype (p=0.0118). Conclusions: HCV genotype 4a subjects with the IL-27-p28.rs153109 A/G and G/G genotype were more likely to clear their HCV infection. Therefore, we propose IL- 27p28.rs153109SNPas a genetic biomarker for predicting HCV infection outcome.

A Study on Exposure Indices for Diesel Engine Exhaust in Forklift Operating Areas (지게차 사용 사업장에서 디젤엔진배출물질 노출지표에 관한 연구)

  • Kim, Sangil;Park, Ji Young;Lee, Kyeongmin;Kim, Seung Won
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.26 no.1
    • /
    • pp.38-47
    • /
    • 2016
  • Objectives: The objective of this study was to determine the exposure levels of forklift operators to diesel engine exhaust(DEE) using black carbon(BC), elemental carbon(EC), and nitrogen dioxide($NO_2$) as indicators. Methods: A total of eight forklift operators in six collection companies were assessed over a period of two months from July to September 2015. BC was measured using a real-time monitor and respirable EC samples were analyzed using the NIOSH method 5040. $NO_2$ samples were collected using a passive badge-type sampler. Results: The geometric mean of BC, EC and $NO_2$ were $3.1-19.1{\mu}g/m^3$, $2.1-23.8{\mu}g/m^3$, and 12.5-166.6 ppb at all companies. When forklifts were operating both outside and inside, BC concentrations increased 2.0-5.6 times. The highest increase was observed when forklifts were operating indoors. The increase in BC concentrations varied by company(company A: 2.0 times, B: 3.2 times, C: 5.6 times, D: 2.1 times, E: 5.1 times, F: 2.6 times). The geometric mean of BC, EC, and $NO_2$ for the forklift operators was $9.6{\mu}g/m^3$, $7.9{\mu}g/m^3$, and 48.9 ppb, respectively. The geometric mean of BC, EC, and $NO_2$ for manufacturing workers was $9.3{\mu}g/m^3$, $0.9{\mu}g/m^3$, and 85.2 ppb, respectively. The mean BC and EC exposure levels for the forklift operators were slightly higher than those for manufacturing workers, but $NO_2$ levels for manufacturing workers were higher than those for the forklift operators(p>0.05). Multiple regression analysis revealed that diesel exhaust emissions standard, forklift weight and forklift manufacturer were the most influential factors in determining worker exposure. Conclusions: In the DEE work environment, workers who perform tasks within the workplace as well as inside forklifts as operators are likely to be exposed to a lack of ventilation. Further study of forklift operators' exposure to DEE indicators should be conducted to include a wider range of occupational and environmental situations, such as collection procedures, seasonal situations, types of fuel used, and number of forklifts.

Defects and Electrical Properties of NiO and Co3O4-doped ZnO-Bi2O3-Sb2O3 Ceramics (NiO와 Co3O4를 첨가한 ZnO-Bi2O3-b2O3 세라믹스의 결함과 전기적 특성)

  • Hong, Youn-Woo;Lee, Young-Jin;Kim, Sei-Ki;Kim, Jin-Ho
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.26 no.1
    • /
    • pp.38-43
    • /
    • 2013
  • In this study we aims to examine the effects of $Co_3O_4$ and NiO doping on the defects and electrical properties in ZnO-$Bi_2O_3-Sb_2O_3$ (Sb/Bi=0.5) varistors. It seemed to form ${Zn_i}^{{\cdot}{\cdot}}$(0.20 eV) and ${V_o}^{\cdot}$(0.33 eV) as dominant defects in Co and Ni co-doped ZBS system, however only ${V_o}^{\cdot}$ appeared in Co- or Ni-doped ZBS. Even though the same defects it was different in capacitance (1.5~4.5 nF) and resistance ($0.3{\sim}9.5k{\Omega}$). The varistor characteristics were improved with Co and Co+Ni doping (non-linear coefficient, ${\alpha}$= 36 and 29, relatively) in ZBS. The various parameters ($N_d=1.43{\sim}2.33{\times}10^{17}cm^{-3}$, $N_t=1.40{\sim}2.28{\times}10^{12}cm^{-2}$, ${\Phi}b$=1.76~2.37 V, W= 98~118 nm) calculated from the C-V characteristics in our systems did not depend greatly on the type of dopant, which were in the range of a typical ZnO varistors. It should be derived a improved C-V equation carefully for more reliable parameters because the variation of the varistor capacitance as a function of the applied dc voltage is depend on the defect, frequency, and temperature.

A Study on the End-Uses Performance of Fabrics for Korean Folk Clothes (한복지의 소비성능에 관한 연구)

  • Sung Su-Kwang;Kwon Oh-Kyung;Hwang Ji-Young
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.15 no.2 s.38
    • /
    • pp.199-209
    • /
    • 1991
  • In this paper, the fabrics for Korean folk clothes(KFC) undergoes repeated laundering under given condition. After this cyclic laundering was applied, the mechanical properties of the specimen were measured using KES-F system in order to evaluated the end-use performance of fabrics for KFC. And also, the crease recovery of fabrics for KFC were measured by shirley crease recovery tester. 78 different kinds of commercial silk fabrics and polyester fabrics for KFC were used for this study. The experimental results were analysed statistically to relate the mechanical properties and the crease recovery of fabrics for KFC. Furthermore, these changes in dimensional stability, mechanical properties and handle of fabrics for KFC were discussed in comparison with those values for silk fabrics and polyester fabrics. The results obtained are as follows. 1. Regardless of materials, remarkable increase are observed in shrinkage of the fabrics for KFC about repeated laundering, but dull increase are observed in shrinkage after 10 cycles of the repeated laundering. On the other hand, slack extend are observed in dimensions after 20 cycles of the repeated laundering. The shrinkage of fabrics for KFC after 10 cycles of the lundering showed that the silk fabrics are $1.74{\pm}0.33\%$ (warp direction) and $1.35{\pm}0.23\%$ (weft direction) and the polyester fabrics are $1.45{\pm}0.22\%$ (warp direction) and $1.25{\pm}0.23\%$ (weft direction). 2. Except for tensile property, these changes in mechanical properties of fabrics for KFC by laundering have $\pm$ 16 range of bending, shearing, compression, surface, thickness & weight as compared with before laundering. Particularly, the LT and RT about $1\~3$ cycles of the repeated laundering showed remarkable decrease. And SMD, WC, T & W of fabrics for KFC by the laundering were more increased than one for original fabrics. But B, 2HB, G, 2HG, 2HGS were decreased more than one for original fabrics. 3. 'Stiffness', 'Anti-drape', 'Crispness' and 'Scroop' hand values decrease and'Fullness & softness', 'Flexibility & softness' hand values increase with repeated laundering. 4. Remarkable decrease are observed in crease recoveries about $1\~5$ cycles of the repeated lundering, but slack decrease are observed in crease recoveries after 5 cycles of repeated laundering. The crease recovery of fabrics for KFC have negative(-) correlation with LT, RT, G, RC and MMD, This fact implies that the smaller these values, the larger the crease recovery. The crease recovery of fabrics for KFC has a high degree of correlation with the mechanical properties such as shearing, compression, surface property. And also, the crease recovery are expected by measuring the mechanical properties such as G, 2HG, 2HGS, RC, WC, LC, MIU, MMD and SMD, according to the obtained regression equation.

  • PDF

Synthesis of ${\alpha}$-Alumina Nanoparticles Through Partial Hydrolysis of Aluminum Chloride Vapor (염화알미늄 증기의 부분가수분해를 통한 알파 알루미나 나노입자 제조)

  • Park, Hoey Kyung;Yoo, Youn Sug;Park, Kyun Young;Jung, Kyeong Youl
    • Korean Chemical Engineering Research
    • /
    • v.49 no.5
    • /
    • pp.664-668
    • /
    • 2011
  • Spherical alumina precursors represented by $AlO_xCl_y(OH)_z$, 30~200 nm in particle diameter, were prepared by partial hydrolysis of $AlCl_3$ vapor in a 500 ml reactor. Investigated on the particle morphology and size were the effects of the reaction time, the stirring speed and the reaction temperature. The particle morphology and size was insensitive to the reaction time in the range 20 to 300 s. The variation of the stirring speed from 0 to 300 and 800 rpm showed that the particle size was the largest at 0 rpm. As the temperature was varied from 180 to 190, 200, $140^{\circ}C$, the particle size showed a maximum at $190^{\circ}C$. By calcination of the as-produced particles at $1,200^{\circ}C$ for 6h with a heating rate of $10^{\circ}C$/min, ${\alpha}$-alumina particles 45 nm in surface area equivalent diameter were obtained. The particle shape after calcination turned wormlike due to sintering between neighboring particles. A rapid calcination at $1400^{\circ}C$ for 0.5 h with a higher heating rate of $50^{\circ}C$/min reduced the sintering considerably. An addition of $SiCl_4$ or TMCTS(2,4,6,8-tetramethylcyclosiloxane) to the $AlCl_3$ reduced the sintering effectively in the calcination step; however, peaks of ${\gamma}$ or mullite phase appeared. An addition of $AlF_3$ to the particles obtained from the hydrolysis resulted in a hexagonal disc shaped alumina particles.

Distribution of Bacterial Decomposers in Lake Khuvsgul, Mongolia (몽골 훕스굴 호수 수층에서 유기물질 분해세균의 분포)

  • Jung, You-Jung;Jung, Da-Woon;Kim, Ju-Young;Zo, Young-Gun;Yim, Joung-Han;Lee, Hong-Kum;Ahn, Tae-Seok
    • Korean Journal of Microbiology
    • /
    • v.45 no.2
    • /
    • pp.119-125
    • /
    • 2009
  • To understand the ecological function of heterotrophic bacterial community in water column of large freshwater lakes in the permafrost zone, we investigated the structure and function of bacterial community in Lake Khuvsgul, Mongolia. Species composition of overall bacterial community was analyzed by denaturing gradient gel electrophoresis (DGGE) of 16S rRNA gene fragments, and bacteria that can be cultured at 10oC were isolated and characterized. Based on the depth profile of environmental parameters, thermocline and chemocline were recognized at the 5~10 m zone of the water column. The stratified DGGE profile indicated that the discontinuity of water properties might influence the structure of bacterial community: band profiles in the 0~5 m zone were diverse with large change by depth, but the profile was relatively stable at the $\geq$10 m zone, with predominance of the band identified as Acidovorax facilis. Bacterial cultures were screened for protease, cellulase, amylase and lipase activity, and 23 isolates were selected for high activity of the hydrolytic enzymes. The isolates were identified based on their 16S rRNA gene sequences. In the surface water (zero meter depth), Acidovorax defluvii and Sphingobacterium faecium with high cellulase activity were present. Flavobacterium succinicans, Mycoplana bullata and A. facilis were stably predominant isolates at 2 m, 5 m, and $\geq$10 m depths, respectively. F. succinicans isolates showed high protease activity while M. bullata isolates showed moderate levels of protease and celluase activity. A. facilis isolates showed either cellulase or lipase activity, exclusively to each other. According to the profile of growth rates of the isolates in the temperature range of $0\sim42^{\circ}C$, the surface-zone (0~5 m) isolates were facultative psychrophiles while isolates from $\geq$10 m depth were typical mesophiles. This stratification is believed to be due to stratified availability of organic materials to the bacterial decomposers. In the water column below the chemoline, the environment is extremely oligotrophic so that the trait of rapid growth in low temperature might not be demanded by deep-lake decomposers. The stratified distribution of community composition and decomposer activity in Lake Khuvsgul implies that ecological functions of bacterial community in lakes of cold region are sharply divided by water column stratification.

Investigation of Autoignition of Propane and n-Butane Blends Using a Rapid Compression Machine

  • Kim, Hyunguk;Yongseob Lim;Kyoungdoug Min;Lee, Daeyup
    • Journal of Mechanical Science and Technology
    • /
    • v.16 no.8
    • /
    • pp.1127-1134
    • /
    • 2002
  • The effects of pressure and temperature on the autoignition of propane and n-butane blends were investigated using a rapid compression machine (RCM) , which is widely used to examine the autoignition characteristics. The RCM was designed to be capable of varying the compression ratio between 5 and 20 and minimize the vortex formation on the cylinder wall using a wedge-shaped crevice. The initial temperature and pressure of the compressed gas were varied in range of 720∼900 K and 1.6∼ 1.8 MPa, respectively, by adjusting the ratio of the specific heat of the mixture by altering the ratio of the non-reactive components (N$_2$, Ar) under a constant effective equivalence ratio (ø$\_$f/= 1.0) The gas temperature after the compression stroke could be obtained from the measured time-pressure record. The results showed a two-stage ignition delay and a Negative Temperature Coefficient (NTC) behavior which were the unique characteristic of the alkane series fuels. As the propane concentration in the blend were increased from 20% and 40% propane, the autoignition delay time increased by approximately 41 % and 55% at 750 K. Numerical reduced kinetic modeling was performed using the Shell model, which introduced some important chemical ideas, represented by the generic species. Several rate coefficients were calibrated based on the experimental results to establish an autoignition model of the propane and n-butane blends. These coefficients can be used to predict the autoignition characteristics in LPG fueled Sl engines.

Site Classification and Design Response Spectra for Seismic Code Provisions - (II) Proposal (내진설계기준의 지반분류체계 및 설계응답스펙트럼 개선을 위한 연구 - (II) 제안)

  • Cho, Hyung Ik;Satish, Manandhar;Kim, Dong Soo
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.20 no.4
    • /
    • pp.245-256
    • /
    • 2016
  • In the companion paper (I - Database and Site Response Analyses), site-specific response analyses were performed at more than 300 domestic sites. In this study, a new site classification system and design response spectra are proposed using results of the site-specific response analyses. Depth to bedrock (H) and average shear wave velocity of soil above the bedrock ($V_{S,Soil}$) were adopted as parameters to classify the sites into sub-categories because these two factors mostly affect site amplification, especially for shallow bedrock region. The 20 m of depth to bedrock was selected as the initial parameter for site classification based on the trend of site coefficients obtained from the site-specific response analyses. The sites having less than 20 m of depth to bedrock (H1 sites) are sub-divided into two site classes using 260 m/s of $V_{S,Soil}$ while the sites having greater than 20 m of depth to bedrock (H2 sites) are sub-divided into two site classes at $V_{S,Soil}$ equal to 180 m/s. The integration interval of 0.4 ~ 1.5 sec period range was adopted to calculate the long-period site coefficients ($F_v$) for reflecting the amplification characteristics of Korean geological condition. In addition, the frequency distribution of depth to bedrock reported for Korean sites was also considered in calculating the site coefficients for H2 sites to incorporate sites having greater than 30 m of depth to bedrock. The relationships between the site coefficients and rock shaking intensity were proposed and then subsequently compared with the site coefficients of similar site classes suggested in other codes.

An experimental study on the cooling performance and the phase shift between piston and displacer in the Stirling cryocooler

  • Park, S. J.;Y. J. Hong;Kim, H. B.;D. Y. Koh;B. K. Yu;Lee, K. B.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.5 no.1
    • /
    • pp.111-117
    • /
    • 2003
  • In the design of the split type free displacer Stilting cryocooler the motion of the displacer is very important to decide the cooling capacity, which depends upon the working gas pressure, the swept volume in the compression space and the expansion space, operating frequency, the phase shift between piston and displacer, etc. In this study, Stirling cryocooler actuated by the electric farce of the dual linear motor is designed and manufactured. Cool down characteristics of the cold end with laser displacement sensor in the expander of the Stilting cryocooler is evaluated. The charging pressure was 15kg$_{f}$/$\textrm{cm}^2$ and operating frequency was 50Hz. Input power and the lowest temperature were about 32W and 67K, respectively. And, displacement of the piston is measured by LVDTs (Linear Variable Differential Transformers), displacement of thedisplacer is measured by laser optic method, and phase shift between piston and displacer is discussed. As the peak-to-peak pressure of the compressor was increased, peak-to-peak displacement of the displacer was increased. The peak-to-peak displacement of the displacer increases in the range of 0 - 64.5Hz(resonant frequency of the displacer), but decreases steeply when the operating frequency is bigger than the resonant frequency. Finally when the phase shift between displacements of the Piston and displacer is 45。, operating frequency is optimum and is decided by resonant frequency of the expander, mass and cross section area of the displacer and constant by friction and flow resistance.e.

A Research on a Cross Post-Distortion Balanced Linear Power Amplifier for Base-Station (기지국용 Cross Post-Distortion 평형 선형 전력 증폭기에 관한 연구)

  • Choi, Heung-Jae;Jeong, Hee-Young;Jeong, Yong-Chae;Kim, Chul-Dong
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.18 no.11
    • /
    • pp.1262-1270
    • /
    • 2007
  • In this paper, we propose a new distortion cancellation mechanism for a balanced power amplifier structure using the carrier cancellation loop of a feedforward and post-distortion technique. The proposed cross post-distortion balanced linear amplifier can reduce nonlinear components as much as the conventional feedforward amplifier through the output dynamic range and broad bandwidth. Also the proposed system provides higher efficiency than the feedforward. The capacities of power amplifier and error power amplifier in the proposed system are analyzed and compared with those of feedforward amplifier. Also the operation mechanisms of the three kind loops are explained. The proposed cross post-distortion balanced linear power amplifier is implemented at the IMT-2000($f_0=2.14\;GHz$) band. With the commercial high power amplifiers of total power of 240 W peak envelope power fer base-station application, the adjacent channel leakage ratio measurement with wideband code division multiple access 4FA signal shows 18.6 dB improvement at an average output power of 40 dBm. The efficiency of fabricated amplifier Improves about 2 % than the conventional feedforward amplifier.