• 제목/요약/키워드: F0 Range

검색결과 1,445건 처리시간 0.027초

기존 하수처리장에서의 처리 효율개선에 관한 연구 (A Study on the improvement of treatment efficiency in a conventional sewage treatment plant)

  • 안철우;박진식;문추연
    • 환경위생공학
    • /
    • 제15권3호
    • /
    • pp.50-56
    • /
    • 2000
  • In this study, sewage were treated with operating Two-step Aeration System and conventional activated sludge process together in a condition. At the same HRT 8hr of Two-step Aeration System and Activated Sludge Process, BOD treatment efficiency of 1st sedimentation basin effluent 36.9% by Two-step Aeration system was 12.3% higher than 24.65 by Activated Sludge Process and the COD treatment efficiency 39.8% by two-step Aeration System was 11.6.3% higher than 28.2% by Activated Sludge Process. BOD and COD treatment efficiencies of 2nd sedimentation basin effluent were 88.1% and 85.6% Two-step Aeration System and were 83.8% and 82.3% Activated Sludge Process. In the first treatment, as BOD was relatively removed a lot, F/M ratio 0.17, $0.21{\cdot}BOD/kg{\cdot}MLSS.d$ was maintained by Activated Sludge Process. Therefore it was proved that organic matter treatment efficiency by Two-step Aeration System os Higher than by Activated Sludge Process in a aeration time 8hr. $NH_4^{+}-N$ treatment efficiencies were 55.5% by Two-step Aeration System and 39.75 by Activated sludge Process. $NO_3^{-}-N$ concentration in 2nd. sedimentation basin effluent were 3.33% by Two-step Aeration System and 2.36% by Activated Sludge Process. From this result, Two-step Aeration System was proved more advantageous treatment process for nitrification than Activated Sludge Process. The fluctuation range of BOD, COD and SS concentration in 2nd sedimentation basin effluent $16~33mg/{\ell}$, $15~23mg/{\ell}$ and $14~22mg/{\ell}$ by Two-step Aeration System was smaller than $16~57mg/{\ell}$, $15~25mg/{\ell}$ by Activated sludge Process. Overall the fluctuation range in 2nd sediment basin effluent by was smaller than by Activated Sludge Process. As a result, it is possible for this Two-step Aeration with no facility investment and a little of operation condition change in a conventional sewage treatment plant to get stability and nitrification of treatment water quality.

  • PDF

류천(柳川) 창연광상(蒼鉛鑛床) 광석광물(鑛石鑛物), 유체포유물(流體包有物) 및 안정동위원소(安定同位元素) (Ore Minerals, Fluid Inclusions and Stable Isotopes of the Yucheon Bismuth Deposits, Korea)

  • 이현구;유봉철;김상중
    • 자원환경지질
    • /
    • 제29권2호
    • /
    • pp.139-150
    • /
    • 1996
  • The Yucheon Bi deposits at Cheongha, Gyeongsangbugdo, is of a middle Paleogene (49 Ma) vein type, and is hosted in sandstone and shale of Banyawal formation in Cretaceous age. Based on mineral paragenesis, vein structure and mineral assemblages, two minera1ization stages were distinguished. The stage I consists of quartz with small amount of chlorite, pyrite, epidote, hal1oysite, vermiculite, serpentine and rutile associated with sericitization. The stage II is characterized by Bi minera1ization such as bismuthinite, Bi-Cu-Pb-S mineral, tetradymite, native gold, pyrite, pyrrhotite, arsenopyrite, wolframite, rutile, hematite, sphalerite, chalcopyrite, galena with alteration of sericite, chlorite, K-feldspar, albite and epidote. Fluid inclusion data indicate that fluid temperature and NaCl equivalent wt.% salinity range from 431 to $150^{\circ}C$ and from 19.2 to 0.18wt.% in the stage II. Evidence of boiling during the base-metal minera1ization indicates pressures 241 to 260 bars. Sulfur fugacity($-log\;f_{S2}$) deduced by mineral assemblages and compositions ranges from 5.1 to 5.7atm in early stage, from > 8.4 atm in middle stage and from 13.5 to 19.3 atm in late stage. It suggests that complex histories of progressive coo1ing, dilution and boiling were occurred by the mixing of the fluids. The ${\delta}^{34}S$, ${\delta}^{18}O$ and ${\delta}D$ data range from 2.5 to 3.9%, -0.5 to -4.1% and -29.7 to -47%, respectively. It indicated that hydrothermal fluids may be magmatic origin with boiling and mixing of meteoric water increasing paragenetic time.

  • PDF

A Pilot Study on Factors Associated with Presentation Delay in Patients Affected with Head and Neck Cancers

  • Baishya, Nizara;Das, Ashok Kumar;Krishnatreya, Manigreeva;Das, Anupam;Das, Kishore;Kataki, Amal Chandra;Nandy, Pintu
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제16권11호
    • /
    • pp.4715-4718
    • /
    • 2015
  • Background: Patient delay can contribute to a poor outcome in the management of head and neck cancers (HNC). The main objective of the present study was to investigate the factors associated with patient delay in our population. Materials and Methods: Patients with cancers of the head and neck attending a regional cancer center of North East India were consecutively interviewed during the period from June 2014 to November 2014. The participation of patients was voluntary. The questionnaire included information on age, gender, residential status, educational qualification, monthly family income, any family history of cancer, and history of prior awareness on cancer from television (TV) program and awareness program. Results: Of 311 (n) patients, with an age range of 14-88 years (mean 55.4 years), 81.7% were males and 18.3% females (M:F=4.4). The overall median delay was 90 days (range=7 days-365 days), in illiterate patients the median delay was 90 days and 60 days in literate patients (P=0.002), the median delay in patients who had watched cancer awareness program on TV was 60 days and in patients who were unaware about cancer information from TV program had a median delay of 90 days (p=0.00021) and delay of <10 weeks was seen in 139 (44.6%) patients, a delay of 10-20 weeks in 98 (31.5%) patients, and a delay of 20-30 weeks in 63 (20.2%) patients. Conclusions: Education and awareness had a significant impact in reduction of median patient delay in our HNC cases.

Remediation of heavy metal-contaminated soils using eco-friendly nano-scale chelators

  • Lim, Heejun;Park, Sungyoon;Yang, Jun Won;Cho, Wooyoun;Lim, Yejee;Park, Young Goo;Kwon, Dohyeong;Kim, Han S.
    • Membrane and Water Treatment
    • /
    • 제9권3호
    • /
    • pp.137-146
    • /
    • 2018
  • Soil washing is one of the most frequently used remediation technologies for heavy metal-contaminated soils. Inorganic and organic acids and chelating agents that can enhance the removal of heavy metals from contaminated soils have been employed as soil washing agents. However, the toxicity, low removal efficiency and high cost of these chemicals limit their use. Given that humic substance (HS) can effectively chelate heavy metals, the development of an eco-friendly, performance-efficient and cost-effective soil washing agent using a nano-scale chelator composed of HS was examined in this study. Copper (Cu) and lead (Pb) were selected as target heavy metals. In soil washing experiments, HS concentration, pH, soil:washing solution ratio and extraction time were evaluated with regard to washing efficiency and the chelation effect. The highest removal rates by soil washing (69% for Cu and 56% for Pb) were achieved at an HS concentration of 1,000 mg/L and soil:washing solution ratio of 1:25. Washing with HS was found to be effective when the pH value was higher than 8, which can be attributed to the increased chelation effect between HS and heavy metals at the high pH range. In contrast, the washing efficiency decreased markedly in the low pH range due to HS precipitation. The chelation capacities for Cu and Pb in the aqueous phase were determined to be 0.547mmol-Cu/g-HS and 0.192mmol-Pb/g-HS, respectively.

Assessment of Semen Quality among Workers Exposed to Heat Stress: A Cross-Sectional Study in a Steel Industry

  • Hamerezaee, Masoud;Dehghan, Somayeh F.;Golbabaei, Farideh;Fathi, Asad;Barzegar, Loghman;Heidarnejad, Naseh
    • Safety and Health at Work
    • /
    • 제9권2호
    • /
    • pp.232-235
    • /
    • 2018
  • Background: This study was conducted to investigate the heat stress and semen quality among male workers in a steel industry in Iran and investigate the relationship between heat stress indices and semen parameters. Methods: The study was conducted on workers exposed (n = 30) and unexposed (n = 14) to heat in a steel industry. After obtaining a brief biography of the selected employees, scrotal temperature, oral temperature, and environmental parameters were measured, and their semen samples were analyzed according to the procedure recommended by the World Health Organization. The heat stress indices, including wet-bulb globe temperature (WBGT) and predicted heat strain (PHS), in their workplace were calculated according to environmental parameters (ISO 7243:1989 and 7933:2004, respectively). Results: Time-weighted averages of WBGT and PHS ($35.76^{\circ}C$ and 491.56 $w/m^2{\frac{w}{m^2}}$, respectively) for the exposed group were higher than threshold limit values. The mean difference of environmental, physiological, and semen parameters (exception: pH of semen), and also WBGT and PHS indices were statistically significant (p < 0.05) between the two groups. Mean semen parameters were in the normozoospermic range. WBGT and PHS indices showed significantly "negative" correlation with physiological parameters (scrotal and oral temperature) and most semen parameters (semen volume, sperm morphology, sperm motility, sperm count; p < 0.05); moreover, the correlation of WBGT with these parameters was stronger than PHS. Conclusion: Semen parameters of the studied workers exposed to heat were in the borderline level of normozoospermic range, and their semen parameters were significantly lower than controls. For better assessment of occupational environment concerning physiological and semen parameters in steel industries, WBGT can be a more useful index.

A Solid-Contact Indium(III) Sensor based on a Thiosulfinate Ionophore Derived from Omeprazole

  • Abbas, Mohammad Nooredeen;Amer, Hend Samy
    • Bulletin of the Korean Chemical Society
    • /
    • 제34권4호
    • /
    • pp.1153-1159
    • /
    • 2013
  • A novel solid-contact indium(III)-selective sensor based on bis-(1H-benzimidazole-5-methoxy-2-[(4-methoxy-3, 5-dimethyl-1-pyridinyl) 2-methyl]) thiosulfinate, known as an omeprazole dimer (OD) and a neutral ionophore, was constructed, and its performance characteristics were evaluated. The sensor was prepared by applying a membrane cocktail containing the ionophore to a graphite rod pre-coated with polyethylene dioxythiophene (PEDOT) conducting polymer as the ion-to-electron transducer. The membrane contained 3.6% OD, 2.3% oleic acid (OA) and 62% dioctyl phthalate (DOP) as the solvent mediator in PVC and produced a good potentiometric response to indium(III) ions with a Nernstian slope of 19.09 mV/decade. The constructed sensor possessed a linear concentration range from $3{\times}10^{-7}$ to $1{\times}10^{-2}$ M and a lower detection limit (LDL) of $1{\times}10^{-7}$ M indium(III) over a pH range of 4.0-7.0. It also displayed a fast response time and good selectivity for indium(III) over several other ions. The sensor can be used for longer than three months without any considerable divergence in potential. The sensor was utilized for direct and flow injection potentiometric (FIP) determination of indium(III) in alloys. The parameters that control the flow injection method were optimized. Indium(III) was quantitatively recovered, and the results agreed with those obtained using atomic absorption spectrophotometry, as confirmed by the f and t values. The sensor was also utilized as an indicator electrode for the potentiometric titration of fluoride in the presence of chloride, bromide, iodide and thiocyanate ions using indium(III) nitrate as the titrant.

치과용 Ti-6Al-4V 합금 골 고정판 표면에 형성된 나노튜브의 부식거동 (Corrosion Behavior of Nanotube Formed on the Bone Plate of Ti-6Al-4V Alloy for Dental Use)

  • 김원기;이충환;정재헌;최한철
    • 한국표면공학회지
    • /
    • 제43권1호
    • /
    • pp.25-30
    • /
    • 2010
  • Titanium and titanium alloys are widely used for orthopedic and dental implants for their superior mechanical properties, low modulus, excellent corrosion resistance and good biocompatibility. In this study, corrosion behaviors of nanotube formed on the bone plate of Ti-6Al-4V alloy for dental use have been investigated. $TiO_2$ nanotubes were formed on the dental bone plates by anodization in $H_3PO_4$ containing 0.6 wt % NaF solution at $25^{\circ}C$. Electrochemical experiments were performed using a conventional three-electrode configuration with a platinum counter electrode and a saturated calomel reference electrode. Anodization was carried out using a scanning potentiostat (EG&G Co, Model 263A USA), and all experiments were conducted at room temperature. The surface morphology was observed using field emission scanning electron microscopy (FE-SEM) and energy dispersive x-ray spectroscopy(EDS). The corrosion behavior of the dental bone plates was examined using potentiodynamic test(potential range of -1500~2000 mV) in a 0.9% NaCl solution by potentiostat (EG&G Co, PARSTAT 2273. USA). The inner diameter of nanotube was about 150~180 nm with wall thickness of about 20 nm. The interspace of nanotube to nanotube was 50 nm. The passive region of the nanotube formed bone plates showed the broad range compared to non-nanotube formed bone plates. The corrosion surface of sample was covered with corrosion products.

서울 일부 지하철 공기 중 라돈과 토론 발생 특성 (Characteristics of airborne radon and thoron levels monitored in Seoul Subway stations and circulation lines)

  • 곽현석;김소연;박지훈;최상준;박동욱
    • 한국산업보건학회지
    • /
    • 제29권2호
    • /
    • pp.176-184
    • /
    • 2019
  • Objective: This study aims to characterize airborne radon and thoron levels ($Bq/m^3$) generated from working environments in three subway stations in Seoul. Method: A radon and thoron detector (EQF3220) was used to monitor real-time airborne radon and thoron levels ($Bq/m^3$) and their daughters ($Bq/m^3$) every two hours. They were monitored not only in the driver's cabin of seven circulation lines, but also three offices, platforms, and water pump reservoirs in the three stations. Results: The average levels of radon and thoron were $67.9Bq/m^3$ (range; $7.2-619.4Bq/m^3$) and $44.4Bq/m^3$ (range; $4.3-819.2Bq/m^3$), respectively. Notably, higher than legal airborne radon levels ($600Bq/m^3$) were frequently monitored in the driver's cabin of seven circulation lines. Airborne radon levels monitored in the platforms and administrative offices were found to be over $100Bq/m^3$. The average equilibrium factors (F) were 0.12 and 0.06, respectively. The percentages detected were found to be 84.9 for radon and 72.4 for thoron, respectively. Conclusions: Significant airborne radon and thoron levels were frequently found to be generated in subway facilities including water reservoirs, platforms and driver's cabins. Further study is necessary to thoroughly investigate airborne radon and thoron in all subway stations and to devise proper measures.

교대근무 간호사의 스트레스 반응, 신체활동, 수면위생이 수면의 질에 미치는 영향 (The Influence of Stress Response, Physical Activity, and Sleep Hygiene on Sleep Quality of Shift Work Nurses)

  • 정지영;구미옥
    • 한국산학기술학회논문지
    • /
    • 제17권6호
    • /
    • pp.546-559
    • /
    • 2016
  • 본 연구의 목적은 교대근무 간호사를 대상으로 스트레스 반응, 신체활동, 수면위생과 수면의 질의 관계를 분석하고, 수면의 질에 미치는 영향요인을 파악하기 위함이다. 연구대상은 경남 C시에 소재한 대학병원과 종합병원에서 교대근무 하는 간호사 168명이었고, 자료수집기간은 2016년 3월 25일부터 2016년 3월 31일까지 였다. 연구도구는 Pittsburgh Sleep Quaility Index, Stress Response Inventory, Korean version International Physical Activity Questionnaire Short Form 및 Sleep Hygiene Practice Scale을 사용하였다. SPSS WIN 18.0을 이용하여 빈도, 백분율, 평균, 표준편차, t-test, ANOVA 및 사후검증, Pearson correlation coefficient, Hierarchical mutiple regression으로 분석하였다. 연구결과, 교대근무 간호사의 수면의 질은 7.35점(범위 0-21점), 스트레스 반응은 2.20점(범위 1-5점), 신체활동량은 3986MET-min/week, 수면위생은 2.73점(범위 1-6점)이었다. 수면의 질은 교대근무 간호사의 특성 중 교대근무 경력, 건강상태, 일주기 리듬에서 유의한 차이를 보였다. 수면의 질에 영향을 미친 변수는 교대근무경력, 수면위생, 스트레스 반응, 신체활동으로 나타났으며 설명력은 40%(F=8.16, p<.001)였다. 따라서, 교대근무 간호사의 수면의 질을 향상시키기 위하여 수면위생 증진 교육을 실시하고, 스트레스 반응을 줄이기 위한 전략을 사용하도록 하며, 중간정도의 신체활동을 권장하는 것이 필요하다.

The Effects of Dietary Phosphorus on the Growth Performance and Phosphorus Excretion of Dairy Heifers

  • Zhang, B.;Wang, C.;Wei, Z.H.;Sun, H.Z.;Xu, G.Z.;Liu, J.X.;Liu, H.Y.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제29권7호
    • /
    • pp.960-964
    • /
    • 2016
  • The objective of this study was to investigate the effects of reducing dietary phosphorus (P) on the frame size, udder traits, blood parameters and nutrient digestibility coefficient in 8- to 10-month-old Holstein heifers. Forty-five heifers were divided into 15 blocks according to the mo of age and were randomly assigned one of three dietary treatments: 0.26% (low P [LP]), 0.36% (medium P [MP]), or 0.42% (high P [HP]) (dry matter basis). Samples were collected at the wk 1, 4, 8. The results show that low dietary P had no effect on body measurement. The blood P concentration decreased with decreasing dietary P (p<0.05), while the blood calcium content of LP was higher than that of the MP and HP groups (p<0.05), though still in the normal range. The serum contents of alkalinephosphatase, potassium, and magnesium were similar among the treatments. No differences were found in all nutrients' apparent digestibility coefficients with varied dietary P. However, with P diet decreased from HP to LP, the total fecal P and urine P concentration declined significantly, as did fecal water soluble P (p<0.05). In conclusion, reducing the dietary P from 0.42% to 0.26% did not negatively affect the heifers' growth performance but did significantly lessen manure P excretion into the environment.