• Title/Summary/Keyword: F-gas

Search Result 1,222, Processing Time 0.028 seconds

Comparison of Gas Exchange Parameters between Same Volume of $N_2-O_2$ and Heliox Inhalation (동일한 상시 호흡량의 $N_2-O_2$ 및 Heliox 투여 시 가스교환지표의 비교)

  • Sohn, Jang-Won;Lim, Chae-Man;Koh, Youn-Suck;Lee, Jong-Deog;Lee, Sang-Do;Kim, Woo-Sung;Kim, Dong-Soon;Kim, Won-Dong
    • Tuberculosis and Respiratory Diseases
    • /
    • v.45 no.1
    • /
    • pp.169-175
    • /
    • 1998
  • Background: Heliox is known to decrease $PaCO_2$ in patients with increased airway resistance by increasing minute ventilation and reducing work of breathing(WOB). Besides these effect, heliox is expected to decrease functional anatomic dead space owing to improvement of peak expiratory flow rate(PEFR) and enhancement of gas distribution. We investigated whether heliox can decrease $PaCO_2$ even at the same minute ventilation (VE) and WOB with $N_2-O_2$ to speculate the effect of the heliox on the anatomic dead space. Material and Method: The subjects were 8 mechanically ventilated patients with asthma or upper airway obstruction(M : F=5 : 3, $68{\pm}10$years) who were under neuromuscular paralysis. The study was consisted of three 15-minutes phases: basal $N_2-O_2$ heliox and washout Heliox was administered via the low pressure inlet of servo 900C, and respiratory parameters were measured by pulmonary monitor(CP-100 pulmonary monitor, Bicore, Irvine, CA, USA). To obtain the same tidal volume(Vt) in heliox phase, the Vt on monitor was adjusted by the factor of relative flow rate of heliox to $N_2-O_2$. Dead space was calculated by Bohr equation. Results: 1) Vt, VE, peak inspiratory pressure(PIP) and peak inspiratory flow rate(PIFR) were not different between $N_2-O_2$ and heliox. 2) PEFR was higher on heliox($0.52{\pm}0.19$L/sec) than $N_2-O_2$($0.44{\pm}0.13$L/sec)(p=0.024). 3) $PaCO_2$(mmHg) were decreased with heliox($56.1{\pm}14.1$) compared to $N_2-O_2$($60.5{\pm}15.9$)(p=0.027). 4) Dead space ventilation(%) were decreased with heliox($73{\pm}9$ with $N_2-O_2$ and $71{\pm}10$ with heliox)(p=0.026). Conclusion: Heliox decreased $PaCO_2$ even at the same VE and WOB with $N_2-O_2$, and the effect was considered to be related with the reduction of anatomic dead space.

  • PDF

Perfluoropolymer Membranes of Tetrafluoroethylene and 2,2,4Trifluofo- 5Trifluorometoxy- 1,3Dioxole.

  • Arcella, V.;Colaianna, P.;Brinati, G.;Gordano, A.;Clarizia, G.;Tocci, E.;Drioli, E.
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 1999.07a
    • /
    • pp.39-42
    • /
    • 1999
  • Perfluoropolymers represent the ultimate resistance to hostile chemical environments and high service temperature, attributed to the presence of fluorine in the polymer backbone, i.e. to the high bond energy of C-F and C-C bonds of fluorocarbons. Copolymers of Tetrafluoroethylene (TEE) and 2, 2, 4Trifluoro-5Trifluorometoxy- 1, 3Dioxole (TTD), commercially known as HYFLON AD, are amorphous perfluoropolymers with glass transition temperature (Tg)higher than room temperature, showing a thermal decomposition temperature exceeding 40$0^{\circ}C$. These polymer systems are highly soluble in fluorinated solvents, with low solution viscosities. This property allows the preparation of self-supported and composite membranes with desired membrane thickness. Symmetric and asymmetric perfluoropolymer membranes, made with HYFLON AD, have been prepared and evaluated. Porous and not porous symmetric membranes have been obtained by solvent evaporation with various processing conditions. Asymmetric membranes have been prepared by th wet phase inversion method. Measure of contact angle to distilled water have been carried out. Figure 1 compares experimental results with those of other commercial membranes. Contact angles of about 120$^{\circ}$for our amorphous perfluoropolymer membranes demonstrate that they posses a high hydrophobic character. Measure of contact angles to hexandecane have been also carried out to evaluate the organophobic character. Rsults are reported in Figure 2. The observed strong organophobicity leads to excellent fouling resistance and inertness. Porous membranes with pore size between 30 and 80 nanometers have shown no permeation to water at pressures as high as 10 bars. However high permeation to gases, such as O2, N2 and CO2, and no selectivities were observed. Considering the porous structure of the membrane, this behavior was expected. In consideration of the above properties, possible useful uses in th field of gas- liquid separations are envisaged for these membranes. A particularly promising application is in the field of membrane contactors, equipments in which membranes are used to improve mass transfer coefficients in respect to traditional extraction and absorption processes. Gas permeation properties have been evaluated for asymmetric membranes and composite symmetric ones. Experimental permselectivity values, obtained at different pressure differences, to various single gases are reported in Tab. 1, 2 and 3. Experimental data have been compared with literature data obtained with membranes made with different amorphous perfluoropolymer systems, such as copolymers of Perfluoro2, 2dimethyl dioxole (PDD) and Tetrafluorethylene, commercialized by the Du Pont Company with the trade name of Teflon AF. An interesting linear relationship between permeability and the glass transition temperature of the polymer constituting the membrane has been observed. Results are descussed in terms of polymer chain structure, which affects the presence of voids at molecular scale and their size distribution. Molecular Dyanmics studies are in progress in order to support the understanding of these results. A modified Theodoru- Suter method provided by the Amorphous Cell module of InsightII/Discover was used to determine the chain packing. A completely amorphous polymer box of about 3.5 nm was considered. Last but not least the use of amorphous perfluoropolymer membranes appears to be ideal when separation processes have to be performed in hostile environments, i.e. high temperatures and aggressive non-aqueous media, such as chemicals and solvents. In these cases Hyflon AD membranes can exploit the outstanding resistance of perfluoropolymers.

  • PDF

Characterization of Traditional Korean Unifloral Honey Based on the Mono-, Di-, and Trisaccharides (한국산 벌꿀의 밀원별 단당, 이당 및 삼당류의 정량 특성)

  • Jang, Eun-Sook;Kim, In-Suk;Lee, Eun-jin;Seo, Hyun-Sun;Lee, Hye-joung;Kim, Eun;Kim, Kyung-Tae;Kim, Jong-Bae
    • Korean Journal of Food Science and Technology
    • /
    • v.48 no.1
    • /
    • pp.1-8
    • /
    • 2016
  • Sugar profiles of 45 Korean honey samples (15 acacia, 15 multi-floral, 10 chestnut, and 5 artificial honey samples), which are commercially available in the Korean markets, were analyzed using gas chromatography/mass spectrometry (GC/MS) through TMS-oxime and TMS-methoxime derivatization. The average invert sugar contents in acacia, multi-floral, chestnut, and artificial honey samples were $71.2{\pm}1.05$, $68.7{\pm}3.26$, $63.2{\pm}1.85$, and $68.0{\pm}2.10%$, respectively. Fourteen disaccharides were detected from the samples, and the average content of major disaccharides was higher in order of turanose, maltulose, maltose, trehalulose, kojibiose, isomaltose, and nigerose. The average content of total disaccharides was highest in chestnut and lowest in acacia. Seven trisaccharides were detected from the samples, and the average content of trisaccharides was the highest in artificial honeys, which had high erlose content. The total content of disaccharides and trisaccharides was highest ($16.0{\pm}2.03%$) in chestnut honey and lowest ($9.70{\pm}1.75%$) in acacia honey.

Chemical Characteristics of PM1 using Aerosol Mass Spectrometer at Baengnyeong Island and Seoul Metropolitan Area (백령도 및 서울 대기오염집중측정소 에어로졸 질량 분석기 자료를 이용한 대기 중 에어로졸 화학적 특성 연구)

  • Park, Taehyun;Ban, Jihee;Kang, Seokwon;Ghim, Young Sung;Shin, Hye-Jung;Park, Jong Sung;Park, Seung Myung;Moon, Kwang Joo;Lim, Yong-Jae;Lee, Min-Do;Lee, Sang-Bo;Kim, Jeongsoo;Kim, Soon Tae;Bae, Chang Han;Lee, Yonghwan;Lee, Taehyoung
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.34 no.3
    • /
    • pp.430-446
    • /
    • 2018
  • To improve understanding of the sources and chemical properties of particulate pollutants on the Korean Peninsula, An Aerodyne High Resolution Time of Flight Aerosol Mass Spectrometer (HR-ToF-AMS) measured non-refractory fine particle ($NR-PM_1$) from 2013 to 2015 at Baengnyeong Island and Seoul metropolitan area (SMA), Korea. The chemical composition of $NR-PM_1$ in Baengnyeong island was dominated by organics and sulfate in the range of 36~38% for 3 years, and the organics were the dominant species in the range of 44~55% of $NR-PM_1$ in Seoul metropolitan area. The sulfate was found to be more than 85% of the anthropogenic origin in the both areas of Baengnyeong and SMA. Ratio of gas to particle partition of sulfate and nitrate were observed in both areas as more than 0.6 and 0.8, respectively, representing potential for formation of additional particulate sulfate and nitrate. The high-resolution spectra of organic aerosol (OA) were separated by three factors which were Primary OA(POA), Semi-Volatility Oxygenated Organic Aerosol (SV-OOA), and Low-Volatility OOA(LV-OOA) using positive matrix factorization (PMF) analysis. The fraction of oxygenated OA (SOA, ${\fallingdotseq}OOA$=SV-OOA+LV-OOA) was bigger than the fraction of POA in $NR-PM_1$. The POA fraction of OA in Seoul is higher than it of Baengnyeong Island, because Seoul has a relatively large number of primary pollutants, such as gasoline or diesel vehicle, factories, energy facilities. Potential source contribution function (PSCF) analysis revealed that transport from eastern China, an industrial area with high emissions, was associated with high particulate sulfate and organic concentrations at the Baengnyeong and SMA sites. PSCF also presents that the ship emissions on the Yellow Sea was associated with high particulate sulfate concentrations at the measurement sites.

Study of Selective Etching of GaAs over AlGaAs and InGaP Semiconductors in High Density Planar Inductively Coupled BCl3/SF6 Plasmas (고밀도 평판형 유도결합 BCl3/SF6 플라즈마를 이용한 GaAs/AlGaAs와 InGaP 반도체의 선택적 식각에 관한 연구)

  • Yoo Seungryul;Ryu Hyunwoo;Lim Wantae;Lee Jewon;Cho Guan Sik;Jeon Minhyon;Song Hanjung;Lee BongJu;Ko Jong Soo;Go Jeung Sang;Pearton S. J.
    • Korean Journal of Materials Research
    • /
    • v.15 no.3
    • /
    • pp.161-165
    • /
    • 2005
  • We investigated selective dry etching of GaAs over AlGaAs and InGaP in high density planar inductively coupled $BCl_3/SF_6$ plasmas. The process parameters were ICP source power (0-500 W), RE chuck power (0-30W) and gas composition $(60-100\%\;BCl_3\;in\;BCl_3/SF_6)$. The process results were characterized in terms of etch rate, selectivities of GaAs over AlGaAs and InGaP, surface morphology, surface roughness and residues after etching. $BCl_3/SF_6$ selective etching of GaAs showed quite good results in this study. Selectivities of GaAs $(GaAs:AlGaAs\~36:1,\;GaAs:InGaP\~45:1)$ were superior at $18BCl_3/2SF_6$, 20 W RF chuck power, 300 W ICP source power and 7.5 mTorr. Addition of $(5-15\%)SF_6\;to\;BCl_3$ produced relatively high selectivities of GaAs over AlGaAs and InGaP during etching due to decrease of etch rates of AlGaAs and InGaP (boiling points of etch products: $AlF_3\~1300^{\circ}C,\;InF_3>1200^{\circ}C$ at atmosphere) at the condition. SEM and AFM data showed slightly sloped sidewall and somewhat rough surface$(RMS\~9nm)$. XPS study on the surface of processed GaAs proved a very clean surface after dry etching. It shows that planar inductively coupled $BCl_3/SF_6$ plasmas could be a good candidate for selective dry etching of GaAs over AlGaAs and InGaP.

Experimental Fetal Cardiopulmonary Bypass in the Fetal Lamb Model (태아양 모델을 이용한 실험적 태아 심폐우회술)

  • 이정렬;임홍국;김원곤;김종성;최정연;김용진
    • Journal of Chest Surgery
    • /
    • v.32 no.6
    • /
    • pp.495-503
    • /
    • 1999
  • Background: We tested the technical feasibility of fetal cardiac bypass and collected baseline data on the fetal hemodynamics and placental functions related to the cardiopulmonary bypass in the fetal lamb model. Material and Method: Eleven fetuses at 120 to 150 days of gestation were subjected to bypass via trans-sternal approach with a 12 G pulmonary arterial cannula and 14 to 18 F venous cannula for 30 minutes. All ewes received general anesthesia with ketamine. In all the fetuses, no anesthetic agents were used except muscle relaxant. Eight served as a group in which placenta was excluded from the extracorporeal circulation by clamping the umbilical cord during the bypass(the oxygenator group) and in the remaining three, the placenta worked as the only source of oxygen supply(the placenta group). Observations were made every 10 minute during a 30-minute bypass and 30-minute post bypass period. No prostaglandin inhibitors were used both in ewes and in fetuses. Result: Weights of the fetuses ranged from 1.9 to 5.2 kg. In the oxygenator group, means of arterial pressure, PaO2, atrial pressure, heart rate, and bypass flow rate ranged 69.8 to 82.6 mmHg, 201.7 to 220.9 mmHg, 4.1 to 4.3 mmHg, 169 to 182/min, and 140.3 to 164.0 ml/kg/min, respectively during bypass, but rapid deterioration of the fetal cardiac functions and the placental gas exchange was observed after the cessation of bypass. In the placenta group, means of arterial pressure decreased from 44.7 to 14.4 mmHg and means of PaCO2 increased from 61.9 to 129.6 mmHg during bypass. Flow rate was suboptimal(74.3 to 97.0 ml/kg/min) during bypass. All hearts fibrillated immediately after the discontinuation of bypass. Conclusion: In this study, the technical feasibility of fetal cardiopulmonary bypass was confirmed in the fetal lamb model. However, further studies with modifications of the bypass including an addition of prostaglandin inhibitor, an application of the total spinal anesthesia on the fetus, a creation of more concise bypass circuit, and a use of active pump are mandatory to improve the outcome.

  • PDF

Prediction of Intubation after Bronchoscopy with Non-invasive Positive Pressure Ventilation Support in Patients with Acute Hypoxemic Respiratory Failure (급성 저산소혈증 환자에서 비침습적 양압환기 적용 하 기관지경 검사 후 기관 삽관의 예측 인자)

  • Song, Jae-Uk;Kim, Su-A;Choi, E Ryoung;Kim, Soo Min;Choi, Hee Jung;Lim, So Yeon;Park, So Young;Suh, Gee Young;Jeon, Kyeongman
    • Tuberculosis and Respiratory Diseases
    • /
    • v.67 no.1
    • /
    • pp.21-26
    • /
    • 2009
  • Background: Non-invasive positive pressure ventilation (NPPV) ensures adequate gas exchange during bronchoscopy in spontaneously breathing, hypoxemic patients, thus avoiding endotracheal intubation. However, in some patients, endotracheal intubation is eventually required after bronchoscopy. This study investigated the incidence of intubation and predictors of a need for emergency intubation prior to NPPV bronchoscopy initiation. Methods: On a retrospective basis, we reviewed the medical records of 36 patients (median age, 55 years; interquartile range [IQR], 43~65 years) with acute hypoxemic respiratory failure who required NPPV during bronchoscopy between January 2005 and October 2007. Results: All patients were hypoxemic (median $PaO_2/FiO_2$ ratio 155; IQR 90~190), but tolerated bronchoscopy with NPPV support. SOFA score and SAPS II score immediately before NPPV initiation were 4 (3~7) and 36 (30~42), respectively. Seventeen (47%) patients needed endotracheal intubation at a median time of 22 (2~50) hours after bronchoscopy. Patients who needed intubation after bronchoscopy had a higher in-hospital mortality (11 [65%] vs. 4 [21%], p=0.017). Upon multiple logistic regression analysis, the need for intubation after bronchoscopy was independently associated with a $P_aO_2/FiO_2$ ratio (OR, 0.961; 95% CI, 0.924~0.999; p=0.047) immediately before NPPV initiation for bronchoscopy. Conclusion: The severity of the hypoxemia immediately prior to NPPV initiation for bronchoscopy was associated with the need for intubation after bronchoscopy in patients with hypoxemic respiratory failure.

Evaluation of Hemodynamic Failure with Acetazolamide Challenged $^{123}I-IMP$ Brain SEPCT and PET (PET과 Acetazolamide 부하 $^{123}I-IMP$ 뇌혈류 SPECT를 이용한 혈역학적 부전의 평가)

  • Chun, Kyung-Ah;Cho, In-Ho;Won, Kyu-Jang;Lee, Hyung-Woo;Hayashida, Kohei
    • The Korean Journal of Nuclear Medicine
    • /
    • v.37 no.2
    • /
    • pp.94-102
    • /
    • 2003
  • Purpose : Cerebral blood flow (CBF) reactivity to acetazolamide (ACZ) is useful to select patients with hemodynamic failure. However, it is still a matter of speculation that varying degrees of regional CBF increases after ACZ administration represent the severity or stage of regional hemodynamic failure as assessed by positron emission tomography (PET). We studied to elucidate whether ACZ challenge $^{123}I-IMP$ brain single photon emission tomography (SPECT) can accurately grade the seventy of regional hemodynamic failure. Materials and Methods: Eighteen patients (M: 16, F: 2, average age: 61 years) with unilateral occlusive disease of the internal carotid artery or the trunk of the middle cerebral artery (MCA). Patients undewent $^{123}I-IMP$ brain SPECT study with acetazolamide challenge and PET study was carried out within 2 weeks before and after SPECT study. Five healthy volunteers with a mean age of 48 years (range: 28-73 yr, M: 3, F: 2) underwent PET studies to determine normal values. In SPECT study, an asymmetry index (Al)-the percentage of radioactivity of region of interest (ROI) in the occlusive cerebrovascular lesion to the contralateral homologous ROI-was used for numerical evaluation of relative $^{123}I-IMP$ distribution. In PET study, regional CBF, oxygen extraction fraction (OEF), cerebral metabolic rate of oxygen ($CMRO_2$) and cerebral blood volume (CBV) values were measured with $^{15}O-labeled$ gas inhalation method and the values were used for comparison with Al (Al during acetazolamide challenge-Al of basal study) on the SPECT study. ROls were classified by severity into three groups (normal, stage I and stage II). Results: Mean values of Al in areas with normal, stage I and stage II hemodynamic failure were $6.25{\pm}7.77%\;(n=107),\;-10.38{\pm}10.41%\:(n=117)\;and\;13.30{\pm}10.51%\;(n=140)$, respectively. Al significantly differed with each groups (p<0.05). Correlation between Al and CBF, OEF and CBV/CBF in hemisphere with occlusive cerebrovascular lesion was 0.20 (p<0.01), -0.28 (p<0.01) and -0.28 (p<0.01), respectively. Conclusion: We concluded that $^{123}I-IMP$ brain SPECT with acetazolamide challenge could determine the severity ad stage of regional hemodynamic failure as assessed by PET.

Amount and Chemical Characteristics of the Epicuticular Waxes on Leaves at Active Tillering and Heading Stages of Rice Varieties (벼 품종들의 분얼성기 및 출수기의 엽표면Wax의 양 및 화학적 조성)

  • Yong Woong, Kwon;Bong Jin, Chung
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.37 no.2
    • /
    • pp.185-197
    • /
    • 1992
  • Differences in the amount and chemical characteristics of the epicuticular waxes on rice leaves were studied for the active tillering and heading stages of rice varieties differing widely in gross leaf-surface property and genetics. The amount of waxes on surfaces of rice leaf-blades was determined by extraction with chloroform and chemical composition of the waxes was characterized by thin layer chromatography, gas liquid chromatography and infrared spectrophotometry. The amount of waxes varied by variety and significantly with growth stage. The amount at the heading stage was 1.7 to 3.6 mg/g fresh weight of leaves, which was two to three times as much as that at the tillering stage of 0.8 to 1.8 mg/g fresh weight. The waxes consisted of seven chemical classes, namely diols, fatty acids, fatty alcohols, fatty aldehydes, fatty esters, saturated and unsaturated hydrocarbons. Diols and unsaturated hydrocarbons were identified as new chemical classes of the rice epicuticular waxes. The polar constituents such as dials, fatty acids and fatty alcohols and the non-polars such as fatty aldehydes, fatty esters, and saturated and unsaturated hydrocarbons were identified at the heading stage, but at the tillering stage only the non-polar compounds were identified. In the carbon numbers (C) of the chemical classes, diols were composed entirely of C30 and acids were mainly of C30 and C31. In alcohols, primary alcohols were composed of C13 and C32, and the secondary alcohols were of C14, C16 and / or C30 regardless of the rice varieties. The acid portion of fatty esters, mainly composed of C22 and C23, showed low cabon numbers compared with the aldehydes. The alcohol portion of them showed a wide distribution in carbon numbers from C13 to C26 depending on the rice varieties. Hydrocarbons had odd carbon numbers, consisting mainly of C29 and C31.

  • PDF

A study on the emission characteristics of greenhouse gases according to the vehicle technology, fuel oil type and test mode (차량기술, 연료 유종 및 시험모드 특성에 따른 온실가스의 배출특성 연구)

  • Lee, Jung-Cheon;Lee, Min-Ho;Kim, Ki-Ho;Park, An-Young
    • Journal of the Korean Applied Science and Technology
    • /
    • v.34 no.4
    • /
    • pp.962-973
    • /
    • 2017
  • Concerns about an air pollution are gradually increasing at home and abroad. The automotive and fuel researchers are trying to reduce emissions and greenhouse gases of vehicles through a research on new engine designs and innovative after-treatment systems using clean fuels (eco-alternative fuel) and fuel quality improvements. In this paper, we stduy the emission characteristics of greenhouse gases on seven vehicles using gasoline, diesel, and LPG by legal test mode in domestic and abroad.(Urban mode, Highway mode, rapidly acceleration and deceleration, using air conditioner, low temperature condition) Regardless of fuels, most of the greenhouse gases tend to show the worst results in cold FTP-75 mode. In the case of A vehicles (2.0 MPI) and B vehicles (2.4 GDI) using a gasoline fuel, the factors that increase greenhouse gases are in order of a rapidly acceleration and deceleration, using air conditioner, low temperature condition. But G vehicles(LPLi) have different emission characteristics from another vehicles. In the case of A vehicles (2.0 w/o DPF) and B vehicles (2.2 with DPF) using a diesel fuel, the factors that increase greenhouse gases are in order of a rapidly acceleration and deceleration, using air conditioner, low temperature condition. However, the factor of F vehicles are in order of low temperature condition, using air conditioner, rapidly acceleration and deceleration. In conclusion, it will be an effective method to apply different technologies of emission reduction for each fuel.