• Title/Summary/Keyword: F-SCAN

Search Result 342, Processing Time 0.027 seconds

$^{18}F$-FDG Colonic Uptake by Oral Anti-Diabetic Drugs Including Metfomin in PET/CT Scan (PET/CT 검사에서 Metformin 성분의 항 당뇨약제에 의한 대장에서의 $^{18}F$-FDG 섭취에 관한 연구)

  • Kim, Sang-Gyu;Park, Hoon-Hee;Kim, Jung-Yul;Bahn, Young-Kag;Lim, Han-Sang;Kim, Jae-Sam;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.50-54
    • /
    • 2010
  • Purpose: The uptake of $^{18}F$-FDG is often observed in normal cell of colon to patients who have non-insulin-dependent diabetes mellitus and had taken anti-diabetic drugs including Metformin in PET/CT scan. In this study, the region of colon was compared between the patients who took anti-diabetic drugs including Metfomin and other patients who took the other anti-diabetic drugs through SUV measurements. Materials and Methods: A hundred eighty patients were studied. 120 patients who have non-insulin-dependent diabetes mellitus (Including Metformin: 60, Excluding Metformin: 60) and 60 patients as a control group were composed. The patient fasted at least 6 hours before receiving an intravenous injection of 370-592 MBq (10-16 mCi) of $^{18}F$-FDG. Scanning from the base of the skull though the mid thigh was performed using the Discovery STe PET/CT Equipment (GE Healthcare, Milwaukee, WI, USA). The highest uptake region was measured SUV among ascending, transverse and descending colon. Results: The values of patients who took the anti-diabetic drugs including Metformin were $6.16{\pm}3.64$ g/mL, $4.41{\pm}2.94$ g/mL, and $5.46{\pm}2.44$ g/mL. The patients who took the anti-diabetic drugs which does not have Metformin were $3.05{\pm}1.39$ g/mL, $2.08{\pm}0.97$ g/mL and $3.15{\pm}1.85$ g/mL. The control group were $2.02{\pm}0.88$ g/mL, $1.68{\pm}0.87$ g/mL and $2.19{\pm}1.88$ g/mL. Conclusion: The effect of the intake of Metformin was observed from the SUV on region of large bowel in this study. Thus, it could be helpful for the results by identifying the ingredient of anti-diabetic drug before the examination and the possibility of interpretation of false positive will be reduced.

  • PDF

The Value of Delayed $^{18}F$-FDG PET/CT Imaging for Differentiating Axillary Lymph Nodes in Breast Cancers (유방암 환자에서 액와 림프절 진단을 위한 $^{18}F$-FDG PET/CT 지연 검사의 유용성)

  • Ji, Young-Sik;Son, Ju-Cheol;Park, Cheol-Woo
    • Journal of radiological science and technology
    • /
    • v.36 no.4
    • /
    • pp.313-318
    • /
    • 2013
  • Positron emission tomography/computed tomography (PET/CT) imaging with fluorodeoxyglucose (FDG) have been used as a powerful fusion modality in nuclear medicine not only for detecting cancer but also for staging and therapy monitoring. Nevertheless, there are various causes of FDG uptake in normal and/or benign tissues. The purpose of present study was to investigate whether additional delayed imaging can improve the diagnosis to differentiate the rates of FDG uptake at axillary lymph nodes (ALN) between malignant and benign in breast cancer patients. 180 PET/CT images were obtained for 27 patients with ALN uptake. The patients who had radiotherapy and chemotherapy were excluded from the study. $^{18}F$-FDG PET/CT scan at 50 min (early phase) and 90 min (delayed phase) after $^{18}F$-FDG injection were included in this retrospective study. The staging of cancers was confirmed by final clinical according to radiologic follow-up and pathologic findings. The standardized uptake value (SUV) of ALN was measured at the Syngo Acquisition Workplace by Siemens. The 27 patients included 18 malignant and 9 ALN benign groups and the 18 malignant groups were classified into the 3 groups according to number of metastatic ALN in each patient. ALNs were categorized less than or equal 3 as N1, between 4 to 9 as N2 and more than 10 as N3 group. Results are expressed as the mean${\pm}$standard deviation (S.D.) and statistically analyzed by SPSS. As a result, Retention index (RI-SUV max) in metastasis was significantly higher than that in non-metastasis about 5 fold increased. On the other hand, RI-SUV max in N group tended to decrease gradually from N1 to N3. However, we could not prove significance statistically in malignant group with ANOVA. As a consequence, RI-SUV max was good indicator for differentiating ALN positive group from node negative group in breast cancer patients. These results show that dual-time-point scan appears to be useful in distinguishing malignant from benign.

Effect of Glucose Level on Brain FDG-PET Images (FDG를 이용한 Brain PET에서 Glucose Level이 영상에 미치는 영향)

  • Kim, In-Yeong;Lee, Yong-ki;Ahn, Sung-Min
    • Journal of radiological science and technology
    • /
    • v.40 no.2
    • /
    • pp.275-280
    • /
    • 2017
  • In addition to tumors, normal tissues, such as the brain and myocardium can intake $^{18}F$-FDG, and the amount of $^{18}F$-FDG intake by normal tissues can be altered by the surrounding environment. Therefore, a process is necessary during which the contrasts of the tumor and normal tissues can be enhanced. Thus, this study examines the effects of glucose levels on FDG PET images of brain tissues, which features high glucose activity at all times, in small animals. Micro PET scan was performed on fourteen mice after injecting $^{18}F$-FDG. The images were compared in relation to fasting. The findings showed that the mean SUV value w as 0.84 higher in fasted mice than in non-fasted mice. During observation, the images from non-fasted mice showed high accumulation in organs other than the brain with increased surrounding noise. In addition, compared to the non-fasted mice, the fasted mice showed higher early intake and curve increase. The findings of this study suggest that fasting is important in assessing brain functions in brain PET using $^{18}F$-FDG. Additional studies to investigate whether caffeine levels and other preprocessing items have an impact on the acquired images would contribute to reducing radiation exposure in patients.

A Development of High Power Activated Carbon Using the KOH Activation of Soft Carbon Series Cokes

  • Kim, Jung-Ae;Park, In-Soo;Seo, Ji-Hye;Lee, Jung-Joon
    • Transactions on Electrical and Electronic Materials
    • /
    • v.15 no.2
    • /
    • pp.81-86
    • /
    • 2014
  • The process parameter in optimized KOH alkali activation of soft carbon series coke material in high purity was set with DOE experiments design. The activated carbon was produced by performing the activation process based on the set process parameters. The specific surface area was measured and pore size was analyzed by $N_2$ absorption method for the produced activated carbon. The surface functional group was analyzed by Boehm method and metal impurities were analyzed by XRF method. The specific surface area was increased over 2,000 $m^2/g$ as the mixing ratio of activation agent increased. The micro pores in $5{\sim}15{\AA}$ and surface functional group under 0.4 meq/g were obtained. The contents of the metal impurity in activated carbon which is the factor for reducing the electrochemical characteristics was reduced less than 100 ppm through the cleansing process optimization. The electrochemical characteristics of activated carbon in 38.5 F/g and 26.6 F/cc were checked through the impedance measuring with cyclic voltammetry scan rate in 50~300 mV/s and frequency in 10 mHz ~100 kHz. The activated carbon was made in the optimized activation process conditions of activation time in 40 minutes, mixing ratio of activation agent in 4.5 : 1.0 and heat treatment temperature over $650^{\circ}C$.

The Effect of Pelvic Tilt Exercise with Changing the Body Position on Foot Contact Pattern in Hemiplegic Patients (자세에 따른 골반경사운동이 편마비 환자의 발 접촉양상에 미치는 효과)

  • Jang, Sang-Hun;Park, Soo-Jin;Kim, Min-Hee;Kim, Joong-Hwi;Kim, Jin-Sang
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.5 no.3
    • /
    • pp.445-453
    • /
    • 2010
  • Purpose : The purpose of this study was to investigate the effect of pelvic tilt exercise with changing the body position on foot contact pattern in the hemiplegic patients. Methods : Thirty seven hemiplegic patients were randomly divided 3 groups; control group (CG), sitting exercise group (SIEG) and standing exercise group (STEG). F-mat system and F-scan system were used for the measurement of foot contact pattern of hemiplegic side in walking. Data were analyzed statistically using paired t-test and one-way ANOVA. Results : The results were as follows : 1) Contact area of CG and SIEG were not significant difference in walking. Contact area of STEG was significant increased in walking. 2) Anteroposterior distance of COP of SIEG and STEG were significant increased in walking. Conclusion : These results suggest that pelvic tilt exercise in sitting and standing position are effective in the improvement of Anteroposterior distance of COP and gait stability are increased in only standing position.

DIAGNOSTIC ACCURACY OF $^{18}F$-FDG IN NODAL NEGATIVE ORAL SQUAMOUS CELL CARCINOMA (구강암 환자에서 경부 임파절 평가에 대한 $^{18}F$-FDG PET(Fluorine 18-Labelled Deoxyglucose Positron Emission Tomography)의 유용성)

  • Choi, Eun-Joo;Kang, Sang-Hoon;Kim, Ki-Ho;Nam, Woong;Kim, Hyung-Jun;Cha, In-Ho
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.33 no.6
    • /
    • pp.597-600
    • /
    • 2007
  • PET is one of the most widely used verification methods for evaluation of metastasis on the lymph nodes of the neck in oral cancer patients. The purpose of this study was to assess the correlation between PET findings and histopathologic findings in patients who had been diagnosed as squamous cell carcinoma and performed neck dissection. Thirty-four necks in 25 patients had been evaluated on pathologic lymph nodes and the data were compared with preoperative PET scan. The sensitivity of PET at the level of the neck was 72.7%, specificity was 60%, and accuracy was 79.2%. Since FDG-PET show high false-positive results, it should be used with other diagnostic tools for evaluation of lymph node metastasis.

Enzymatic properties of the N- and C-terminal halves of human hexokinase II

  • Ahn, Keun-Jae;Kim, Jong-Sun;Yun, Mi-Jin;Park, Jeon-Han;Lee, Jong-Doo
    • BMB Reports
    • /
    • v.42 no.6
    • /
    • pp.350-355
    • /
    • 2009
  • Although previous studies on hexokinase (HK) II indicate both the N- and C-terminal halves are catalytically active, we show in this study the N-terminal half is significantly more catalytic than the C-terminal half in addition to having a significantly higher $K_m$ for ATP and Glu. Furthermore, truncated forms of intact HK II lacking its first N-terminal 18 amino acids ($\Delta$18) and a truncated N-terminal half lacking its first 18 amino acids ($\Delta$18N) have higher catalytic activity than other mutants tested. Similar results were obtained by PET-scan analysis using $^{18}F-FDG$. Our results collectively suggest that each domain of HK II possesses enzyme activity, unlike HK I, with the N-terminal half showing higher enzyme activity than the C-terminal half.

Thin Film Energy Storage Device with Spray-Coated Sliver Paste Current Collector

  • Yoon, Seong Man;Jang, Yunseok;Jo, Jeongdai;Go, Jeung Sang
    • ETRI Journal
    • /
    • v.39 no.6
    • /
    • pp.874-879
    • /
    • 2017
  • This paper challenges the fabrication of a thin film energy storage device on a flexible polymer substrate specifically by replacing most commonly used metal foil current collectors with coated current collectors. Mass-manufacturable spray-coating technology enables the fabrication of two different half-cell electric double layer capacitors (EDLC) with a spray-coated silver paste current collector and a Ni foil current collector. The larger specific capacitances of the half-cell EDLC with the spray-coated silver current collector are obtained as 103.86 F/g and 76.8 F/g for scan rates of 10 mV/s and 500 mV/s, respectively. Further, even though the half-cell EDLC with the spray-coated current collector is heavier than that with the Ni foil current collector, smaller Warburg impedance and contact resistance are characterized from Nyquist plots. For the applied voltages ranging from -0.5 V to 0.5 V, the spray-coated thin film energy storage device exhibits a better performance.

Micro-Structural and Electrochemical Properties of Activated Carbon Synthesized from Natural Bamboo (천연 대나무로부터 합성된 활성 탄소의 미세구조 및 전기화학적 특성)

  • YANG, DONG-CHEOL;KIM, SU-WON;CHOURASHIYA, M.G.;PARK, CHOONG-NYEON;PARK, CHAN-JIN
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.30 no.5
    • /
    • pp.418-427
    • /
    • 2019
  • Activated carbon was synthesized from bamboo charcoal by KOH activation at various temperatures for electrochemical double layer capacitor applications. The micro-structural and surface properties of all the samples were characterized by X-ray diffraction, scanning electron microscopy and N2 adsorption/desorption isotherm method. The electrochemical properties of the activated bamboo charcoal were examined by cyclic voltammetry in the potential window of -1.0 to 0.2 V in 6 M KOH electrolyte at different scan rates. An electrode made from the sample activated with 7.5 M KOH and heat treated at $750^{\circ}C$ for 3 h gave a maximum capacitance of 553 F/g at 1 mV/s and 450 F/g at 10mV/s.

Effect of Change in Degrees of Inclination during Treadmill Gait Training on EEG of Stroke Patients (경사도 각도에 따른 트레드밀 보행훈련 시 뇌졸중 환자의 뇌파에 미치는 영향)

  • Sun-Min Kim;Dong-Hoon Kim;Sang-Hun Jang
    • PNF and Movement
    • /
    • v.22 no.1
    • /
    • pp.139-149
    • /
    • 2024
  • Purpose: This study aimed to investigate the effects of gradually increasing treadmill inclination on the electroencephalogram (EEG) of stroke patients during gait training. Methods: Three stroke patients who were diagnosed with stroke within six months and capable of walking on a treadmill were selected as subjects. EEG electrodes were attached at Fp1, Fp2, F3, F4, C3, C4, P3, and P4 positions of the cerebral hemispheres using the International 10-20 system. The intervention involved walking for 2 minutes each at 0 degrees, 15 degrees, and 30 degrees inclination on the treadmill while focusing on a target point located in front during the treadmill gait training. The EEG (Smartingmobi, Serbia) generated when the treadmill gradient gradually increased was measured. In addition, relative alpha and relative beta waves were visualized through the Brain mapping program in the TeleScan program to assess the changes in each brain region for the activity of the EEG. Results: The relative alpha wave value decreased as treadmill inclination increased, while the relative beta wave value increased. Conclusion: Gradually increasing the inclination during treadmill gait training appears to be a crucial parameter for increasing the brain activity levels of stroke patients.