• Title/Summary/Keyword: F-SCAN

Search Result 343, Processing Time 0.028 seconds

A study of Brain Micro-PET Imaging and Bindingpotential with a Different Specific Activity of 18F-Fallypride in the Small Animal (소동물에서 18F-Fallypride의 비방사능에 따른 뇌의 PET이미지와 Binding Potential 차이에 대한 연구)

  • Cho, Kyu-Sang;Ahn, Sung-Min
    • The Journal of the Korea Contents Association
    • /
    • v.15 no.9
    • /
    • pp.418-424
    • /
    • 2015
  • In this study, we proceed if there are any changes in binding ability of receptor-ligand in some degree of SA and in radioactive uptake from the corpus striatum based on small animal experiment in vivo based on the S.A values. By dividing 18F-Fallypride into 3 S.A values(high S.A : 43.29~74 GBq/umol, ordinary S.A : 20.72~29.23 GBq/umol, low S.A : 6.29~8.51 GBq/umol), we injected directly into the veins and performed 90 minutes of dynamic scan using Micro PET. After scanning, we compared and analyzed with Binding Potential (Binding Potential) from the bilateral striatum. high SA and low SA, ordinary SA and low SA showed significant differences. Also, in the image comparison using 18F-Fallypride show high radioactive uptake in the striatum at high SA and ordinary SA, but the radioactive uptake at low SA is lower than other two SA. Since 18F-Fallypride has affinity to dopamine D2/3 pharmacokinetic, the difference of Binding Potentials at decreased level of SA values was not that significant. However, further PET research of the corpus striatum using 18F-Fallypride is necessary because the differences in images and Binding Potentials at 6.5 times smaller SA values compared to high SA value showed were significant.

Clinical experience with $^{18}F$-fluorodeoxyglucose positron emission tomography and $^{123}I$-metaiodobenzylguanine scintigraphy in pediatric neuroblastoma: complementary roles in follow-up of patients

  • Gil, Tae Young;Lee, Do Kyung;Lee, Jung Min;Yoo, Eun Sun;Ryu, Kyung-Ha
    • Clinical and Experimental Pediatrics
    • /
    • v.57 no.6
    • /
    • pp.278-286
    • /
    • 2014
  • Purpose: To evaluate the potential utility of $^{123}I$-metaiodobenzylguanine ($^{123}I$-MIBG) scintigraphy and $^{18}F$-fluorodeoxyglucose ($^{18}F$-FDG) positron emission tomography (PET) for the detection of primary and metastatic lesions in pediatric neuroblastoma (NBL) patients, and to determine whether $^{18}F$-FDG PET is as beneficial as $^{123}I$-MIBG imaging. Methods: We selected 8 NBL patients with significant residual mass after operation and who had paired $^{123}I$-MIBG and $^{18}F$-FDG PET images that were obtained during the follow-up. We retrospectively reviewed the clinical charts and the findings of 45 paired scans. Results: Both scans correlated relatively well with the disease status as determined by standard imaging modalities during follow-up; the overall concordance rates were 32/45 (71.1%) for primary tumor sites and 33/45 (73.3%) for bone-bone marrow (BM) metastatic sites. In detecting primary tumor sites, $^{123}I$-MIBG might be superior to $^{18}F$-FDG PET. The sensitivity of $^{123}I$-MIBG and $^{18}F$-FDG PET were 96.7% and 70.9%, respectively, and their specificity were 85.7% and 92.8%, respectively. $^{18}F$-FDG PET failed to detect 9 true NBL lesions in 45 follow-up scans (false negative rate, 29%) with positive $^{123}I$-MIBG. For bone-BM metastatic sites, the sensitivity of $^{123}I$-MIBG and $^{18}F$-FDG PET were 72.7% and 81.8%, respectively, and the specificity were 79.1% and 100%, respectively. $^{123}I$-MIBG scan showed higher false positivity (20.8%) than $^{18}F$-FDG PET (0%). Conclusion: $^{123}I$-MIBG is superior for delineating primary tumor sites, and $^{18}F$-FDG PET could aid in discriminating inconclusive findings on bony metastatic NBL. Both scans can be complementarily used to clearly determine discrepancies or inconclusive findings on primary or bone-BM metastatic NBL during follow-up.

Efficacy of I-123/I-131 Metaiodobenzylguanidine Scan as A Single Initial Diagnostic Modality in Pheochromocytoma: Comparison with Biochemical Test and Anatomic Imaging (갈색세포종의 초기 진단에서 I-123/I-131 Metaiodobenzylguanidine 스캔의 단일 검사로써의 진단 성능: 생화학적 검사, 해부학적 영상과 비교)

  • Moon, Eun-Ha;Lim, Seok-Tae;Jeong, Young-Jin;Kim, Dong-Wook;Jeong, Hwan-Jeong;Sohn, Myung-Hee
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.43 no.5
    • /
    • pp.436-442
    • /
    • 2009
  • Purpose: We underwent this study to evaluate the diagnostic potential of I-123/I-131 metaiodobenzylguanidine (MIBG) scintigraphy alone in the initial diagnosis of pheochromocytoma, compared with biochemical test and anatomic imaging. Materials & Methods: Twenty two patients (M:F=13:9, Age: $44.3{\pm}\;19.3$ years) having the clinical evaluation due to suspicious pheochromocytoma received the biochemical test, anatomic imaging modality (CT and/or MRI) and I-123/I-131 MIBG scan for diagnosis of pheochromocytoma, prior to histopathological confirmation. MIBG scans were independently reviewed by 2 nuclear medicine physicians. Results: All patients were confirmed histopathologically by operation or biopsy (incisional or excisonal). In comparison of final diagnosis and findings of each diagnostic modality, the sensitivities of the biochemical test, anatomic imaging, and MIBG scan were 88.9%, 55.6%, and 88.9%, respectively. And the specificities of the biochemical test, anatomic imaging, and MIBG scan also were 69.2%, 69.2%, and 92.3%, respectively. MIBG scan showed one false positive (neuroblastoma) and one false negative finding. There was one patient with positive MIBG scan and negative findings of the biochemical test, anatomic imaging. Conclusion: Our data suggest that I-123/I-131 MIBG scan has higher sensitivity, specificity, positive predictive value, negative predictive value and accuracy than those of biochemical test and anatomic imaging. Thus, we expect that MIBG scan is e tectively used for initial diagnosis of pheochromocytoma alone as well as biochemical test and anatomic imaging.

Fabrication of Supercapacitors using Silver Nano Paste and Gel Electrolyte (은 나노 페이스트와 젤 전해질을 이용한 슈퍼캐패시터 제작)

  • Yoon, Seong Man;Jang, Hyunjung;Kim, Dae Won;Jang, Yunseok;Jo, Jeongdai;Go, Jeung Sang
    • Clean Technology
    • /
    • v.19 no.4
    • /
    • pp.410-415
    • /
    • 2013
  • The supercapacitors were fabricated using silver (Ag) nano paste and activated carbon paste on the polyimide (PI) film and 5% potassium polyacrylate (PAAK) was used for gel electrolyte. In this paper, the current collector film and the electrode film were fabricated using screen printing. The thickness of printed silver paste was $7.3{\mu}m$ and the sheet resistance has the range of $5-7m{\Omega}/square$. An activated carbon with a surface area of $1,968m^2/g$, an electronic conducting agent (SUPER P, TIMCAL) and poly (4-vinylphenol) were mixed in 2-(2-buthoxyethoxy) ethyl acetate (BCA) with a ratio of 7:1:3 to fabricate the electrode paste. To analyze electrochemical characteristics, cyclic voltammetry was performed to evaluate the stability of the devices under the voltage range of -0.5-0.5 V. The calculated specific capacitances were 44.04 and 8.62 F/g for 10 and 500 mV/s scan rates, respectively.

The Study of Radiation Exposure Reduction by Developing Corpus Striatum Phantom (두개골-선조체 팬텀을 이용한 선량 저감화 방안 연구)

  • Kim, Jung-Soo;Park, Chan-Rok
    • Journal of radiological science and technology
    • /
    • v.40 no.4
    • /
    • pp.595-603
    • /
    • 2017
  • The study is to produced a brain phantom simulating corpus striatum, which can evaluate the progression of parkinson's disease, to investigate possibility of reducing the brain exposure dose to CT while maintaining optimal image quality during PET-CT examinations. CT scans were performed by varying tube voltage (100, 120 kVp) and tube current (80, 140, 200 mAs) with $^{18}F$ FP-CIT injected into the phantom's hot sphere and background (radioactivity ratio 3:1)(reference condition; 120 kVp, 140 mAs). Estimated effective dose was calculated by using conversion factor according to each condition, and image quality was evaluated by setting SNR and CRChot image evaluation factors. Experimental results showed that the predicted effective dose below the CT imaging reference condition was reduced by at least 10% and by up to 60%, and the predicted effective dose beyond the reference condition was increased by 40%. In addition, there was no significant difference between SNR and CRChot of PET images, and it was confirmed that brain dose decreased with decrease of tube voltage and tube current. At the same time, there was no significant change in the quality of the image in terms of SNR and CRChot despite the change in scan conditions. This fact suggests that the quality of the images acquired under the existing dose conditions can be obtained even at low dose conditions and it is expected that it will be possible to use the brain PET-CT scan as a basic data for the research on reduction of dose and improvement of image quality.

Genome scan linkage analysis identifies a major quantitative trait loci for fatty acid composition in longissimus dorsi muscle in an F2 intercross between Landrace and Korean native pigs

  • Park, Hee-Bok;Han, Sang-Hyun;Yoo, Chae-Kyoung;Lee, Jae-Bong;Kim, Ji-Hyang;Baek, Kwang-Soo;Son, Jun-Kyu;Shin, Sang-Min;Lim, Hyun-Tae;Cho, In-Cheol
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.30 no.8
    • /
    • pp.1061-1065
    • /
    • 2017
  • Objective: This study was conducted to locate quantitative trait loci (QTL) influencing fatty acid (FA) composition in a large $F_2$ intercross between Landrace and Korean native pigs. Methods: Eighteen FA composition traits were measured in more than 960 $F_2$ progeny. All experimental animals were genotyped with 165 microsatellite markers located throughout the pig autosomes. Results: We detected 112 QTLs for the FA composition; Forty seven QTLs reached the genome-wide significant threshold. In particular, we identified a cluster of highly significant QTLs for FA composition on SSC12. QTL for polyunsaturated fatty acid on pig chromosome 12 (F-value = 97.2 under additive and dominance model, nominal p-value $3.6{\times}10^{-39}$) accounted for 16.9% of phenotypic variance. In addition, four more QTLs for C18:1, C18:2, C20:4, and monounsaturated fatty acids on the similar position explained more than 10% of phenotypic variance. Conclusion: Our findings of a major QTL for FA composition presented here could provide helpful information to locate causative variants to improve meat quality traits in pigs.

Relationships among Obesity, Bone Mineral Density, and Cardiovascular Risks in Post-menopausal Women (폐경 후 여성의 비만, 골밀도와 심혈관질환 위험도 간의 관계)

  • So, Hee-Young;Ahn, Suk-Hee;Song, Rha-Yun;Kim, Hyun-Li
    • Women's Health Nursing
    • /
    • v.16 no.3
    • /
    • pp.224-233
    • /
    • 2010
  • Purpose: This study explored the relationships among obesity, bone mineral density, and cardiovascular risks in post-menopausal women. Methods: One hundred post-menopausal women were recruited via convenience sampling from osteoporosis prevention program participants who were living in a metropolitan city in September 2006. Obesity was evaluated by body mass index, bone mineral density measured by DEXA scan, and cardiovascular risk factors assessed by a guideline of American Heart Association. Results: Seventy-two percent of women were either in the osteopenia or osteoporosis group, while 28% were in normal range in lumbar vertebrae. Obese women had greater bone mineral density in lumbar (F=3.31, p=.040) and femur (F=4.72, p=.011). Variables for cardiovascular risks were significantly different for high density lipoprotein (F=7.51, p=.001), systolic blood pressure (F=5.21, p=.007), and in percent of 10-year cardiovascular disease risk according to obesity. Conclusion: Post-menopausal women are at risk for obesity, osteoporosis, and cardiovascular disease. In order to prevent these conditions, nursing interventions such as resistance and aerobic exercise that reduces body weight and bone loss, increases high density lipoprotein, and reduces systolic blood pressure, should be proposed continually through health promotion programs for postmenopausal women.

System Design and Performance Analysis of $MnO_2$ Pseudo-capacitor for Digital Communication Applications (디지털 통신 응용을 위한 $MnO_2$, Pseudo-capacitor의 시스템 설계 및 성능평가)

  • Seong W. K.;Hong M. S.;Kim S. W.
    • Journal of the Korean Electrochemical Society
    • /
    • v.3 no.4
    • /
    • pp.241-245
    • /
    • 2000
  • The objective of this work Is to design, fabricate, and characterize pseudo-capacitor using amorphous $MnO_2\;nH_2O$ electrode material. The cyclic voltammogram under 100mV/s scan rate of the material shows the electrochemically stable potential window of 1V and the specific capacitance of 250F/g. The TDMA pulse test result indicates that the TDMA system (2 parallel-pseudo-capacitor systems) has the ohmic voltage drop of 0.22V and the capacitor voltage drop of 0.38V. The total voltage drop of the TDMA system is 0.60V and less than 1V of which value is the maximum voltage drop requirement or the TDMA satellite phone. Also, the TDMA system had the ESR of $55m{\Omega}$ and the capacitance of 105mF. Therefore, it is confirmed that the TDMA system has the application feasibility as load-leveling capacitor for the satellite phone.

Evaluation of the Response of Radiotherapy to Squamous Cell Carcinoma of the Head and Neck using $^{18}FDG-PET$ (두경부 편평상피세포암종에서 $^{18}FDG-PET$을 이용한 방사선치료 반응평가)

  • Lee Sang-Wook;Ryu Jin-Sook;Yi Byong-Yong;Kim Jong-Hoon;Ahn Seung-Do;Shin Seong-Soo;Kim Sang-Yoon;Nam Soon-Yuhl;Song Si-Yeol;Yoon Sang-Min;Park Jin-Hong;Kim Sung-Bae;Kim Jae-Seung
    • Korean Journal of Head & Neck Oncology
    • /
    • v.19 no.1
    • /
    • pp.58-62
    • /
    • 2003
  • Purpose: To evaluate the efficacy of positron emission tomography with 2-[F-18] fluoro-2-deoxy-D-glucose in discrimination of response in the nasopharyngeal carcinoma patients who treated with radiotherapy. Methods and Materials: Twenty-four patients who underwent FDG-PET scan before and after radiotherapy for no disseminated head and neck carcinoma at the Asan Medical Center between August 2001 and September 2002 were evaluate by prospective analysis. First FDG-PET scan performed before radiotherapy within 1 month, and second FDG-PET scan performed 1 month after radiotherapy. FDG-PET images were analyzed by standard uptake value (SUV). Follow-up period was more than 6 months. Results: The pretreatment SUV was 3.4-14.0 (median: 6.0) and posttreatment SUV was ground level-7.7 (median: 2.0). The overall sensitivity and specicity of FDG-PET to evaluate residual tumors in the nasopharyngeal carcinoma patients were 94% and 94%. Conclusion: FDG-PET is effective in evaluation of radiation response in the nasopharyngeal carcinoma. We think that the timing of one month after finished radiotherapy FDG-PET scan was not too fast to evaluation of radiation response.

Change of PET Image According to CT Exposure Conditions (CT 촬영 조건에 따른 PET 영상의 변화)

  • Park, Jae-Yoon;Kim, Jung-hoon;Lee, Yong-Ki
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.3
    • /
    • pp.473-479
    • /
    • 2019
  • PET-CT improves performance and reduces the time by combining PET and CT of spatial resolution, and uses CT scan for attenuation correction. This study analyzed PET image evaluation. The condition of the tube voltage and current of CT will be changed using. Uniformity phantom and resolution phantom were injected with 37 MBq $^{18}F$ (fluorine ; 511 keV, half life - 109.7 min), respectively. PET-CT (Biograph, siemens, US) was used to perform emission scan (30 min) and penetration scan. And then the collected image data were reconstructed in OSEM-3D. The same ROI was set on the image data with a analyzer (Vinci 2.54, Germany) and profile was used to analyze and compare spatial resolution and image quality through FWHM and SI. Analyzing profile with pre-defined ROI in each phantom, PET image was not influenced by the change of tube voltage or exposure dose. However, CT image was influenced by tube voltage, but not by exposure dose. When tube voltage was fixed and exposure dose changed, exposure dose changed too, increasing dose value. When exposure dose was fixed at 150 mA and tube voltage was varied, the result was 10.56, 24.6 and 35.61 mGy in each variables (in resolution phantom). In this study, attenuation image showed no significant difference when exposure dose was changed. However, when exposure dose increased, the amount of dose that patient absorbed increased too, which indicates that CT exposure dose should be decreased to minimum to lower the exposure dose that patient absorbs. Therefore future study needs to discuss the conditions that could minimize exposure dose that gets absorbed by patient during PET-CT scan.