• Title/Summary/Keyword: F-18 FDG-PET/CT

Search Result 330, Processing Time 0.023 seconds

Clinical Application of $^{18}F-FDG$ PET in Ovarian Cancer (난소암에서 $^{18}F-FDG$ PET의 임상 이용)

  • Oh, So-Won;Kim, Seok-Ki
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.42 no.sup1
    • /
    • pp.91-100
    • /
    • 2008
  • Ovarian cancer is often fatal since it is difficult to diagnose early and recurrence is quite frequent despite successful implementation of cytoreductive surgery and chemotherapy, thus exact diagnosis and early detection of recurrence are crucial to patient management. For pre-treatment staging, FDG PET could be helpful in a limited patient group possessing high risks of ovarian cancer. Besides, FDG PET could be recommended to patients with a high suspicion of recurrence i.e. rise of CA-125, especially in cases of conventional diagnostic imaging modalities presenting no evidence of disease because FDG PET provides critical information for treatment planning such as recurrence site or pattern. In order to expand the use of FDG PET to general population at staging or routine surveillance of ovarian cancer, more investigation is needed. The usefulness of FDG PET in evaluating treatment response and prognosis of ovarian cancer has not yet been determined, but it has been reported that FDG PET could evaluate treatment response early and show a close relationship with overall survival. PET/CT has been actively adopted in management of ovarian cancer. Not only in detecting tumor recurrence and evaluating treatment response but also in pre-treatment staging, FDG PET/CT is expected to playa role due to available anatomical information.

Sarcoid-Like Reaction after Complete Remission of Malignancy: CT and 18F-FDG PET/CT Features for the Differential Diagnosis from Lymph Node Metastasis (악성종양의 완전관해 후 발생한 사르코이드증 유사 반응: 림프절 전이와의 감별진단에 유용한 CT와 18F-FDG PET/CT 소견)

  • Hyun Ji Kang;Yookyung Kim;June Young Bae;Jung Hyun Chang;Soo-Hyun Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.82 no.4
    • /
    • pp.903-913
    • /
    • 2021
  • Purpose To identify the imaging features indicative of sarcoid-like reactions in patients with intrathoracic lymphadenopathy after complete remission of malignancies. Materials and Methods This study enrolled five patients with histopathologically confirmed sarcoid-like reactions that developed after cancer remission. The clinical features and findings of CT and 18F-fluorodeoxyglucose (FDG) PET/CT were assessed. Results The underlying malignancies included breast, nasopharyngeal, colon, and endometrial cancer and lymphoma. The time intervals between complete remission of malignancy and the diagnosis of sarcoid-like reaction ranged from 6 to 78 months. CT findings of sarcoid-like reaction included bilateral hilar and mediastinal lymphadenopathies (n = 5), pulmonary nodules (1-15 mm) with peribronchovascular, fissural, or subpleural distribution, and interlobular interstitial thickening in the lungs (n = 4). 18F-FDG PET/CT revealed hypermetabolic uptake in the mediastinal and hilar lymph nodes and both lungs in the absence of extrathoracic uptake (n = 3). The sarcoid-like reactions resolved in all patients after corticosteroid treatment. Conclusion In patients with complete remission of malignancies, newly developed bilateral hilar and mediastinal lymphadenopathies with or without pulmonary nodules of perilymphatic distribution, in the absence of recurrence at the primary tumor site and extrathoracic metastasis, may suggest a sarcoid-like reaction. Such cases warrant histologic evaluation of the lymph nodes to prevent unnecessary systemic chemotherapy.

Clinical Application of $^{18}F-FDG$ PET in Head and Neck Cancer (두경부 종양에서 $^{18}F-FDG$ PET의 임상이용)

  • Kim, Jae-Seung;Bae, Jin-Ho
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.42 no.sup1
    • /
    • pp.6-13
    • /
    • 2008
  • Head and neck cancer is the sixth most common type of human cancer worldwide. Squamous cell carcinoma is the most common cancer of the head and neck. Since $^{18}F-FDG$ PET is very sensitive to detecting squamous cell carcinoma, it has been widely used in patients with head and neck cancers for initial staging, management of recurrent cancers, and therapeutic monitoring. According to clinical research data, $^{18}F-FDG$ PET is expected to be a very helpful diagnostic tool in the management of head and neck cancer.

Reduction of Injection Dose in 18F-FDG Fusion PET (PET-CT 검사에서 18F-FDG 투여량 감소에 대한 고찰)

  • Kim, Jong-Pil;Kim, Jae-Il;Lee, Hong-Jae;Kim, Jin-Eui
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.2
    • /
    • pp.17-21
    • /
    • 2014
  • Purpose With the recent rise of social issue regarding radiation exposure, attention to medical radiation use has been placed under a great spotlight. During PET-CT examination, generally about 40% more of $^{18}F$-FDG is used than EANM recommendation. While maintaining the diagnostic test result, we hope to find optimal injection dose to minimize the $^{18}F$-FDG in patients by utilizing the latest PET-CT scanner which is equiped with the newest technology. Materials and Methods During this experiment, the Biograph Truepoint 40 (siemens, USA) installed in 2007 and mCT 64 (siemens, USA) installed in 2011 were used and evaluated NECR (noise-equivalent counting rate) by using a scatter phantom. For the image quality evaluation of each scanner, we injected 3.7, 4.44 and 5.18 MBq/kg of $^{18}F$-FDG in NEMA IEC Body Phantom and also evaluated SNR between two scanners by using the data acquired at 60, 70, 80, 90, 100, 110 and 120 sec per bed. For the clinical evaluation, actual data of patients who were injected $^{18}F$-FDG 3.7, 4.44, 5.18 MBq/kg were used to compare SNR and draw a final result. Results As a result, mCT 64 peak NECR value was 1.65e+005, which is 10% higher than Turepoint 40. SNR values using the IEC body phantom was 17.9%, 17.4% and 17.1% higher in $^{18}F$-FDG 3.7 MBq/kg, 4.44 MBq/kg and 5.18 MBq/kg. In clinical patients, SNR values of the image mCT 64 was 16.5, which is 25% higher than Turepoint 40 scanner. Conclusion To draw a conclusion from the test result of this experiment, the same quality of SNR could be attained even with 10% reduced injection dose, if when the duration is extended by 10 sec/bed. This optimal result was possible due to enhanced equipment. The NECR (one of the equipment's performance assessment criteria for the scanner) increased by 10% and the SNR (one of the image quality assessment criteria) also increased by 17.5%. Therefore, we can expect to reduce the injection dose without deterioration of image quality. In consequence, it will also help to decrease the patient's anxiety of the radiation exposure.

  • PDF

Comparison between FDG Uptake and Pathologic or Immunohistochemical Parametersin Pre-operative PET/CT Scan of Patient with Primary Colorectal Cancer (원발성 대장-결장암 환자의 치료 전 PET/CT 스캔에서 FDG 섭취 정도와 병리학적 및 면역조직화학적 지표들과의 비교)

  • Na, Sae-Jung;Chung, Yong-An;Maeng, Lee-So;Kim, Ki-Jun;Sohn, Kyung-Myung;Kim, Sung-Hoon;Sohn, Hyung-Sun;Chung, Soo-Kyo
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.43 no.6
    • /
    • pp.557-564
    • /
    • 2009
  • Purpose: To evaluate the relationship between F-18 FDG uptake of tumor in PET/CT scan and pathological or immunohistochemial parameters of colorectal cancer. Materials and Methods: 147 colorectal cancer patients who underwent both pre-operative F-18 FDG PET/CT scan and surgery were included. In cases with perceptible FDG uptake in primary tumor, the maximum standardized uptake value (SUVmax) was calculated. The pathologic results such as site, size, depth of invasion (T stage), growth pattern, differentiation of primary tumor, lymph node metastasis and Dukes-Astler & Coller stage and immunohistochemical markers such as expression of EGFR, MLH1, MSH2 and Ki-67 index were reviewed. Results: 146 out of 147 PET/CT scans with colorectal cancer showed perceptible focal FDG uptake. SUVmax showed mild positive linear correlation with size of primary tumor (r=0.277, p=0.001) and Ki-67 index (r=0.226, p=0.019). No significant difference in F-18 FDG uptake was found according to site, depth of invasion (T stage), growth pattern, differentiation of primary tumor, presence of lymph node metastasis, Dukes-Astler & Coller stage and expression of EGFR. Conclusion: The degree of F-18 FDG uptake in colorectal cancer was associated with the size and the degree of Ki-67 index of primary tumor. It could be thought that FDG uptake of primary tumor has a correlation with macroscopic and microscopic tumor growth.

Clinical Application of $^{18}F-FDG$ PET in Gastric Cancer (위암에서 $^{18}F-FDG$ PET의 임상 이용)

  • Yun, Mi-Jin;Kim, Tae-Sung;Hwang, Hee-Sung
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.42 no.sup1
    • /
    • pp.39-45
    • /
    • 2008
  • PET or PET/CT detects only less than 50% of early gastric cancer and 62-98% of advanced gastric cancer. Therefore, mass screening programs are recommended for all adults over the age of 40 for early detection and early treatment of gastric cancer through endoscopy or various radiological tests. The most important step after diagnosis of gastric cancer is accurate staging, which mainly evaluates tumor resectability to avoid unnecessary surgery. Important factors that affect tumor resectability are whether the tumor can be separated from adjacent organs or important blood vessels, the extent of lymph node metastasis, presence of peritoneal metastasis, or distant organ metastasis. To evaluate the extent of local tumor invasion, anatomical imaging that has superior spatial resolution is essential. There are a few studies on prognostic significance of FDG uptake with inconsistent results between them. In spite of lower sensitivity for lymph node staging, the specificity of CT and PET are very high, and the specificity for PET tends to be higher than that for CT. Limited data published so far show that PET seems less useful in the detection of lung and bone metastasis. In the evaluation of pleural or peritoneal metastasis, PET seems very specific but insensitive as well. When FOG uptake of primary tumor is low, distant metastasis also tends to show low FDG uptake reducing its detection on PET. There are only a few data available in the evaluation of recurrence detection and treatment response using FDG PET or PET/CT.

The Value of Delayed $^{18}F$-FDG PET/CT Imaging for Differentiating Axillary Lymph Nodes in Breast Cancers (유방암 환자에서 액와 림프절 진단을 위한 $^{18}F$-FDG PET/CT 지연 검사의 유용성)

  • Ji, Young-Sik;Son, Ju-Cheol;Park, Cheol-Woo
    • Journal of radiological science and technology
    • /
    • v.36 no.4
    • /
    • pp.313-318
    • /
    • 2013
  • Positron emission tomography/computed tomography (PET/CT) imaging with fluorodeoxyglucose (FDG) have been used as a powerful fusion modality in nuclear medicine not only for detecting cancer but also for staging and therapy monitoring. Nevertheless, there are various causes of FDG uptake in normal and/or benign tissues. The purpose of present study was to investigate whether additional delayed imaging can improve the diagnosis to differentiate the rates of FDG uptake at axillary lymph nodes (ALN) between malignant and benign in breast cancer patients. 180 PET/CT images were obtained for 27 patients with ALN uptake. The patients who had radiotherapy and chemotherapy were excluded from the study. $^{18}F$-FDG PET/CT scan at 50 min (early phase) and 90 min (delayed phase) after $^{18}F$-FDG injection were included in this retrospective study. The staging of cancers was confirmed by final clinical according to radiologic follow-up and pathologic findings. The standardized uptake value (SUV) of ALN was measured at the Syngo Acquisition Workplace by Siemens. The 27 patients included 18 malignant and 9 ALN benign groups and the 18 malignant groups were classified into the 3 groups according to number of metastatic ALN in each patient. ALNs were categorized less than or equal 3 as N1, between 4 to 9 as N2 and more than 10 as N3 group. Results are expressed as the mean${\pm}$standard deviation (S.D.) and statistically analyzed by SPSS. As a result, Retention index (RI-SUV max) in metastasis was significantly higher than that in non-metastasis about 5 fold increased. On the other hand, RI-SUV max in N group tended to decrease gradually from N1 to N3. However, we could not prove significance statistically in malignant group with ANOVA. As a consequence, RI-SUV max was good indicator for differentiating ALN positive group from node negative group in breast cancer patients. These results show that dual-time-point scan appears to be useful in distinguishing malignant from benign.

Clinical Application of $^{18}F-FDG$ PET in Bile Duct Cancer (담도암에서 $^{18}F-FDG$ PET의 임상 이용)

  • Yun, Mi-Jin;Kim, Tae-Sung;Hwang, Hee-Sung
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.42 no.sup1
    • /
    • pp.66-70
    • /
    • 2008
  • Reports about FDG PET in biliary tumor are limited and there are almost no reports regarding its efficacy. Biliary tumor is divided to intrahepatic and extrahepatic bile duct cancer, and intrahepatic bile duct cancer can be further divided to peripheral type which occurs at lobular duct and hilar type which occurs at hepatic hilum. Surgical resection is the only curative method for bile duct tumor, and accurate staging plays an important role in deciding treatment modality. Among intrahepatic bile duct tumors, peripheral type and hilar type have the same histological characteristics, but different clinical manifestations and tumor growth pattern. On PET image, FDG uptake is also different between peripheral type and hilar type. Most of the former shows high FDG uptake at primary and metastasis site so it is very useful for determining stage and changing treatment plans. However, the later is diversified among low uptake and very high uptake. The FDG uptake pattern of hilar type is similar to that of extrahepatic bile duct cancer, and mucinous component is an important factor, which affects FOG uptake. When tumor cells are scattered in desmoplatsic stroma, then FDG uptake is low as well. In contrast, when FDG uptake is high, it is likely to be tubular type which has high tumor density. Tumor growth pattern also affects FDG uptake. Nodular type mostly takes higher FDG compared to infiltrative type. There are many cases where benign inflammatory diseases take high FDG that PET alone can not distinguish malignant lesion from benign lesion. In conclusion, studies about PET using FDG are still limited. Thus, it is hard to make accurate conclusion about the roles of PET or PET/CT in biliary cancers, but peripheral type intrahepatic bile duct cancers and mass forming hilar and extrahepatic bile duct cancers appear to be good indications performing FDG PET or PET/CT.

The Usefulness of $^{18}F$-FDG PET/CT for Predicting the Response of Locally Advanced Rectal Cancer to Neoadjuvant Chemoradiation Therapy (국소 진행된 직장암의 $^{18}F$-FDG PET/CT를 이용한 항암방사선치료의 반응성 예측)

  • Kang, Jin-Kyu;Kim, Mi-Sook;Choi, Chul-Won;Jeong, Su-Young;Yoo, Seong-Yul;Cho, Chul-Koo;Yang, Kwang-Mo;Yoo, Hyung-Jun;Cheon, Gi-Jeong;Shin, Young-Joo;Seo, Young-Seok
    • Radiation Oncology Journal
    • /
    • v.27 no.3
    • /
    • pp.111-119
    • /
    • 2009
  • Purpose: This study aimed at assessing the value of fluorine-18 fluorodeoxyglucose positron emission tomography ($^{18}F$-FDG PET) for predicting the response of locally advanced rectal cancer to neoadjuvant CRT. Materials and Methods: Between August 2006 and January 2008, we prospectively enrolled 20 patients with locally advanced rectal cancer and who were treated with neoadjuvant CRT at the Korea Institute of Radiological and Medical Sciences. The treatment consisted of radiation therapy and chemotherapy, and this was followed by curative resection 6 weeks later. All the patients underwent $^{18}F$-FDG PET/CT both before CRT and 6 weeks after completing CRT. The measurements of the FDG uptake ($SUV_{max}$), the absolute difference (${\Delta}SUV_{max}$) and the percent $SUV_{max}$ difference (response index, $RI_{SUV}$) between the pre- and post-CRT $^{18}F$-FDG PET/CT scans were assessed. The measurements of the metabolic volume, the absolute difference (${\Delta}$metabolic volume) and the percent metabolic volume difference (response index, $RI_{metabolic\;volume}$) were also assessed. Results: Of the 20 patients who underwent surgery, 11 patients (55%) were classified as responders according to Dworak's classification. The post-CRT $SUV_{max}$ was significantly lower than the pre-CRT $SUV_{max}$. However, there were no significant differences in the $SUV_{max}$ and the metabolic volume reduction between the responders and non-responders. We used a minimum $SUV_{max}$ reduction of 67% as the cut-off value for defining a response, with a sensitivity of 45.5%, a specificity of 88.9%, a positive predictive value of 77% and a negative predictive value of 53.8%. Conclusion: Although there were no statistically significant results in this study, other studies have revealed that $^{18}F$-FDG PET/CT has the potential to assess the tumor response to neoadjuvant CRT in patients with locally advanced rectal cancer.

Evaluation of 18F-FDG PET/CT Image Distortion by NEMA IEC Body Phantom (NEMA IEC Body Phantom을 이용한 18F-FDG PET/CT 영상의 왜곡 평가)

  • Park, jooncheol;Yang, hanjoon
    • Journal of the Korea Safety Management & Science
    • /
    • v.15 no.4
    • /
    • pp.427-433
    • /
    • 2013
  • Recently, 18F-FDG PET based CT scan was a critical examination that the after, before plan diagnosis and treatment of tumors. But, due to the distortion of SUV that should be proportional to the metabolic rate of glucose in the tumor, the other measurement methods are being on study. In this study, compared the degree of distortion of SUV that according to the volume of the tumor analysis ROI and VOI using the NEMA IEC Phantom. The results, the SUVmax, mean value are rapidly decreased with threshold value 500 mm2 interval of the ROI analysis, 1500 mm3 interval of the VOI analysis. When compared SUVmax value SUVmean, ROI and VOI analysis VOI measurements was 1.077 times higher SUVmax was 0.981 times highe compared to the value of the ROI measurement. Compare MTV, SUV 2.0 as measured by the volume of the VOI to Volume showed a slightly higher results(Volume / MTV = $93.4 %{\pm}14.8 %$). Considering the above results, Tumor evaluation by 18F-FDG PET / CT scan Consider each threshold value should be analyzed due to larger SUV's Distortion depending on the size of the tumor. VOI analysis is recommended. because it showed the VOI analysis is higher than the ROI analysis SUVmax and lower SUVmean due to VOI analysis than once as a measure of the wider area as measured ROI analysis. MTV (R2 = 0.999), a result close to the actual size of the tumor. but, more research is needed in this regard, because SUV according to the standards of value are affected.