• Title/Summary/Keyword: F and $F^{+}$-Center

Search Result 4,102, Processing Time 0.037 seconds

Method to Reduce the Activity Loss and Pain when Injecting 18F-Florbetaben (18F-Florbetaben 주사 시 Activity 손실과 통증 감소를 위한 방법)

  • Kwon, Hyeong Jin;Choi, Jin Wook;Lee, Hyeong Jin;Woo, Jae Ryong;Kim, Yoo Kyeong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.20 no.2
    • /
    • pp.42-45
    • /
    • 2016
  • Purpose Neuracep is used to other diagnostic evaluations of the brain to estimate beta-amyloid neuritic plaque density in adult patients with cognitive impairment and inspected cognitive impairment. $^{18}F-Florbetaben$ specially has moderate lipophilicity and property of the added ethanol. It is the subject of interest of the patient pain and residual activity after injecting. Our study is effective injection method of the radiopharmaceutical and patient care. So it is for the highest quality image. Materials and Methods Patients were targeted 70 subjects, it was injected mean $259{\pm}74MBq$ to the patients ($^{18}F-FDG$: 20 subjects, $^{18}F-FP-CIT$: 20 subjects, $^{18}F-Florbetaben$: 30 subjects). After injection (reflusing 2 times, reflusing 3 times) using a 3-way set, it measured the residual activity. When injecting $^{18}F-Florbetaben$, we evaluated the effective injection methods(3-way set method and heparin cap method). The average residual activity after the injection was compared using a statistical analysis of SPSS 12.0(ANOVA, t-test analysis). Also, elemental analysis was performed on $^{18}F-Florbetaben$ by GC (Gas Chromatography). Results When reflusing 2 times measured residual activity as follows ($^{18}F-FDG$: 1.48 MBq, $^{18}F-FP-CIT$: 7.4 MBq, $^{18}F-Florbetaben$: 32.6 MBq). And when reflusing 3 times measured residual activity as follows ($^{18}F-FDG$: 1.85 MBq, $^{18}F-FP-CIT$: 3.7 MBq, $^{18}F-Florbetaben$: 36.3 MBq). There was a significant difference when reflusing 2 times(P < 0.05) and reflusing 3 times (P < 0.05). But when reflusing 3 times, there was no significant difference relation FDG and FP-CIT (P > 0.05). $^{18}F-Florbetaben$ Residual activity according to the injection method was a significant difference (P < 0.05). GC analysis results were measured ethanol: 207665 ppm and acceton: 377.4 ppm. Conclusion $^{18}F-Florbetaben$ was high residual activity compared to FDG and FP-CIT. Heparin cap method was effective when $^{18}F-Florbetaben$ was injected. $^{18}F-Florbetaben's$ ethanol component analysis was highly measured. So it is recommended that inject to 6 sec/ml or more in order to reduce the pain.

  • PDF

Accuracy of [$^{18}F$]FDG PET after Surgery and Radiotherapy in Head and Neck Cancers (두경부종양에서 수술 및 방사선 치료 후 [$^{18}F$FDG PET의 진단적 정확도)

  • Yang, Weon-Il;Choi, Chang-Woon;Lee, Yong-Sik;Kim, Byeung-Il;Lee, Jae-Sung;Lim, Sang-Moo;Shim, Yoon-Sang;Hong, Sung-Woon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.33 no.6
    • /
    • pp.466-474
    • /
    • 1999
  • Purpose: The purpose of this study was to evaluate the diagnostic accuracy of [$^{18}F$]FDG PET in the diagnosis of recurrent head and neck cancer after the completion of surgery and radiotherapy in patients with head and neck cancers. Materials and Methods: In fifty-nine patients with head and neck cancers whole body [$^{18}F$]FDG PET studies were performed. According to the different therapeutic modalities, patients were divided into four groups (Group I; pre-treatment, Group II: surgery, Group III; radiotherapy, Group IV; both surgery and radiotherapy). [$^{18}F$]FDG PET images were compared with clinical, CT and histopathologic findings. Results: for detection of metastatic lymph nodes in 14 patients of pre-treatment group (group I), the sensitivity and specificity of PET were 100% (10/10) and 75% (3/4), and those of CT were 80% (8/10) and 100% (4/4). For detection of recurrence in 45 patients of post-treatment group, overall sensitivity and specificity of PET were 96.2% (25/26) and 78.9% (15/19) [(100% and 75% in group II, 80% and 10% in group III, and 100% and 100% in group IV)] without significant difference from pre-treatment group (P>0.1). In detecting recurrence, the sensitivity and specificity of [$^{18}F$]FDG PET were 90.9% (10/11) and 20% (1/5) in 16 patients who underwent [$^{18}F$]FDG PET within 2 months after the completion of treatment. The specificity of these patients was significantly lower than that of 29 patients (100% of sensitivity and specificity) who underwent [$^{18}F$]FDG PET 2 months after treatment (p<0.05). Conclusion: [$^{18}F$]FDG PET is an accurate diagnostic modality for the detection of recurrence in head and neck cancer. Post-therapy [$^{18}F$]FDG PET should be obtained at least 2 months after the completion of surgery or radiotherapy.

  • PDF

Fluorine doping effect of ZnO film by RF magnetron sputtering (RF magnetron sputtering을 이용한 ZnO 박막의 F 도핑 효과)

  • Ku, Dae-Young;Kim, In-Ho;Lee, In-Kyu;Lee, Kyeong-Seok;Park, Jong-Keuk;Lee, Taek-Sung;Baik, Young-Jun;Cheong, Byung-Ki;Kim, Won-Mok
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.07b
    • /
    • pp.1023-1028
    • /
    • 2004
  • RF magnetron sputtering을 이용하여 증착한 투명전도성 ZnO 박막의 F 도핑량에 따른 전기, 구조, 광학적 특성에 대해 고찰하였다. 순수 ZnO와 ZnO : $ZnF_2$(1.3 wt%) 그리고 ZnO : $ZnF_2$(10 wt%) 3개의 타겟들을 2개씩 조합 각각의 rf 파워를 조절하여 co-sputtering 방법으로 $ZnF_2$ wt%를 변화시켜 박막내의 F 도핑량을 조절하였다. 증착된 박막들은 열처리에 따른 물성 변화를 분석하기 위해 $5{\times}10^{-7}$ torr 이하의 진공 분위기에서 $300^{\circ}C$에서 2 시간 동안 열처리하였다. XRD 분석 결과 제작된 모든 ZnO 박막은 (002) 우선 방위 특성을 보였고 F 도핑량 증가에 따라 (101), (110), (100) 방향의 약한 피크들이 나타났으며, 이러한 구조적 특성 변화는 이동도의 변화와 밀접한 관계가 있는 것으로 나타났다. Auger로 박막 내의 F 량을 분석한 결과 최대 5.9 at%의 F이 포함되어 있었으며, 열처리 후 캐리어 농도와 이동도는 증가하였고 최고 $37cm^2/Vs$의 이동도를 나타내었으며, 모든 박막들은 가시광 영역에서 81 % 이상의 투과도를 가졌다.

  • PDF

Identification and Cloning of a Fraction 1 Protein of Yersinia pestis that Produces Protective Immune Responses

  • Kim Jong-Hyun;Cho Seung-Hak;Jang Hyun-Chul;Lee Hee-Cheul;Kim Young-Il;Kang Yeon-Ho;Lee Bok-Kwon
    • Journal of Microbiology and Biotechnology
    • /
    • v.16 no.8
    • /
    • pp.1180-1184
    • /
    • 2006
  • The capsule that surrounds Yersinia pestis cells is composed of a protein-polysacchride complex; the purified protein component is fraction I (F1) antigen. We report the cloning of the cafl gene and its expression in Escherichia coli using the vector pETl02/D-TOPO and the F1-specific monoclonal antibody. The recombinant F1 (rF1) antigen had a molecular size of 17.5 kDa, which was identical to that of the F1 antigen produced by Y. pestis. Recombinant F1 protein was found to react to polyclonal antiserum to Y. pestis Fl. Recombinant F1 was purified by ProBond purification system and induced a protective immune response in BALB/c mice challenged with up to 10$^5$ virulent Y. pestis. Purified rF1 protein was used in an ELISA to evaluate the ability of a method to detect antibodies to Y. pestis in animal sera. These results strongly indicated that the rF1 protein is a suitable species-specific immunodiagnostic antigen and vaccine candidate.

Infinite Selectivity Etching Process of Silicon Nitride to ArF PR Using Dual-frequency $CH_2F_2/H_2/Ar$ Capacitively Coupled Plasmas (Dual-frequency $CH_2F_2/H_2/Ar$ capacitively coupled plasma를 이용한 실리콘질화물과 ArF PR의 무한 선택비 식각 공정)

  • Park, Chang-Ki;Lee, Chun-Hee;Kim, Hui-Tae;Lee, Nae-Eung
    • Journal of the Korean institute of surface engineering
    • /
    • v.39 no.3
    • /
    • pp.137-141
    • /
    • 2006
  • Process window for infinite etch selectivity of silicon nitride $(Si_3N_4)$ layers to ArF photoresist (PR) was investigated in dual frequency superimposed capacitive coupled plasma (DFS-CCP) by varying the process parameters such as low frequency power $(P_{LF})$, $CH_2F_2$ and $H_2$ flow rate in $CH_2F_2/H_2/Ar$ plasma. It was found that infinite etch selectivities of $Si_3N_4$ layers to the ArF PR on both blanket and patterned wafers can be obtained for certain gas flow conditions. The etch selectivity was increased to the infinite values as the $CH_2F_2$ flow rate increases, while it was decreased from the infinite etch selectivity as the $H_2$ flow rate increased. The preferential chemical reaction of the hydrogen with the carbon in the polymer film and the nitrogen on the $Si_3N_4$ surface leading to the formation of HCN etch by-products results in a thinner steady-state polymer and, in turn, to continuous $Si_3N_4$ etching, due to enhanced $SiF_4$ formation, while the polymer was deposited on the ArF photoresist surface.

F-RATIONALITY OF A PURE SUBRING OF AN F-RATIONAL RING

  • Moon, Myung-In
    • Communications of the Korean Mathematical Society
    • /
    • v.12 no.4
    • /
    • pp.851-854
    • /
    • 1997
  • In this paper we will show that the pure subring R of F-rational ring S is F-rational when R is a one-dimensional ring, or S is a Gorenstein ring. And we will give a condition that a pure subring of an F-rational ring is to be F-rational.

  • PDF

Effects of Exercise Prescription Service and Participation Level on Satisfaction and Reuse Intention of Fitness Center Users (피트니스센터 이용자들의 운동처방환경서비스와 참가정도가 이용만족도 및 재이용의도에 미치는 영향)

  • Park, Hye-Min;Yang, Jung-Su;Lee, Sang-Duk;Yoo, Shin-Hwan
    • Journal of Korea Entertainment Industry Association
    • /
    • v.13 no.4
    • /
    • pp.217-228
    • /
    • 2019
  • This study was designed to investigate the effect of exercise prescription service on user satisfaction and reuse intention of fitness center users in C region, Gangwon-do. The subjects of this study were 250 fitness center users aged 20 and over. Survey was conducted to examine users satisfaction and reuse intention. The final analysis data is 227 copies and the results are as follows. First, there was a significant difference in sex at the facility of satisfaction of use(t=2.308, p=.022). The marriage showed a significant difference in the price among user satisfaction(t=2.490, p=.014) and reuse intention(t=-1.968, p=.05). Age showed significant differences in the duration of participation(F=7.117, p=.000), frequency (F=6.171, p=.000), and intensity(F=2.791, p=.027). User satisfaction showed significant differences according to price(F=6.171, p=.000), leader(F=3.083, p=.017) and reuse intention(F=2.699, p=.032). There was a significant difference in education groups in terms of duration of participation(F=3.656, p=.007) and frequency(F=3.164, p=.015). leader(F=5.170, p=.001) and price(F=2.899, p=.023) were different in user satisfaction. Jobs showed a significant difference in the duration of participation(F=4.685, p=.000), intensity(F=2.373, p=.023) and reuse intention(F=4.840, p=.000). Monthly income showed a significant difference in user satisfaction(F=4.651, p=.001) and facility(F=2.606, p=.037). Second, there was a significant difference in the duration of participation according to presence or absence of exercise prescription service(t=-4.410, p=.000). There was also significant differences in the user satisfaction(t=-7.951, p=.000), leader(t=5.304, p=.000), facility(t=2.033, p=.043) and reuse intention(t=4.640, p=.000) in terms of the presence of exercise prescription service. Third, in the relation between exercise prescription service and the participation level, there was a significant effect of the leader(β=.221, p=.001) and the price(β=.135, p=.045) of user satisfaction, and the reuse intention(β=.182, p=.007). Fourth, among the user satisfaction influenced by exercise prescription service, facilities(β=.178, p=.005) and leader(β=.497, p=.000) were found to affect reuse intention.

Self Oscillating Double Conversion Mixer for low cost mm-wave system (밀리미터파 대역에서 저가격화 시스템을 위한 Self Oscillating Double Conversion Mixer)

  • Lee, Sang-Jin;Ahn, Dan;Lee, Mun-Kyo;Kwon, Hyuk-Ja;Baek, Tae-Jong;Jun, Byoung-Chul;Park, Hyun-Chang;Rhee, Jin-Koo
    • Proceedings of the IEEK Conference
    • /
    • 2006.06a
    • /
    • pp.491-492
    • /
    • 2006
  • The MMIC (Microwave Monolithic Integrated Circuit) self oscillating double conversion mixer was designed and fabricated for the V-band transmitter applications. The MMIC self oscillating double conversion mixer which dose not need external local oscillator was designed using GaAs PHEMT technology. The first self oscillating mixer use PHEMT technology. The first self oscillating mixer use PHEMT for $f_{LO}$ signal generation and $f_{IF}$ signal is applied at gate port and $f_{RF1}$ signal is generated at a drain port of first stage. The second gate mixer use PHEMT for $f_{LO}$ signal and $f_{RF1}$ signal is applied at gate port and $f_{RF2}$ signal is output at a drain port of second stage.

  • PDF

Frequency effect of TEOS oxide layer in dual-frequency capacitively coupled CH2F2/C4F8/O2/Ar plasma

  • Lee, J.H.;Kwon, B.S.;Lee, N.E.
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.02a
    • /
    • pp.284-284
    • /
    • 2011
  • Recently, the increasing degree of device integration in the fabrication of Si semiconductor devices, etching processes of nano-scale materials and high aspect-ratio (HAR) structures become more important. Due to this reason, etch selectivity control during etching of HAR contact holes and trenches is very important. In this study, The etch selectivity and etch rate of TEOS oxide layer using ACL (amorphous carbon layer) mask are investigated various process parameters in CH2F2/C4F8/O2/Ar plasma during etching TEOS oxide layer using ArF/BARC/SiOx/ACL multilevel resist (MLR) structures. The deformation and etch characteristics of TEOS oxide layer using ACL hard mask was investigated in a dual-frequency superimposed capacitively coupled plasma (DFS-CCP) etcher by different fHF/ fLF combinations by varying the CH2F2/ C4F8 gas flow ratio plasmas. The etch characteristics were measured by on scanning electron microscopy (SEM) And X-ray photoelectron spectroscopy (XPS) analyses and Fourier transform infrared spectroscopy (FT-IR). A process window for very high selective etching of TEOS oxide using ACL mask could be determined by controlling the process parameters and in turn degree of polymerization. Mechanisms for high etch selectivity will discussed in detail.

  • PDF

Rapid Energy Transfer Mechanism of F Electronic Excitation to the Vibration of Randomly Distributed $OH^- in KCI

  • 장두전;아철승
    • Bulletin of the Korean Chemical Society
    • /
    • v.19 no.10
    • /
    • pp.1063-1068
    • /
    • 1998
  • The nature of F electronic excitation energy transfer to OH- vibrational levels in KCl crystals is the exchange interaction, although the transfer process exhibits three temporally distinguishable components depending on the distance between excited F center and OH-. The critical distance as well as rate of the major energy transfer process in randomly distributed samples increases rapidly as OH- librational motions become active with temperature rise. The excited state character introduced into the OH- ground electronic state by perturbation is essential for the exchange interaction. The perturbation is brought about by the expanded electron cloud of excited F center for OH- associated to F center, whereas by librations and lattice vibrations perpendicular to the bond axis for isolated OH- . F excitation quenching efficiency by OH- is dependent on the variation of the critical distance rather than the rate as the rate is much faster than the normal F bleach recovery rate.