• Title/Summary/Keyword: Eye point

Search Result 340, Processing Time 0.022 seconds

Object Magnification and Voice Command in Gaze Interface for the Upper Limb Disabled (상지장애인을 위한 시선 인터페이스에서의 객체 확대 및 음성 명령 인터페이스 개발)

  • Park, Joo Hyun;Jo, Se-Ran;Lim, Soon-Bum
    • Journal of Korea Multimedia Society
    • /
    • v.24 no.7
    • /
    • pp.903-912
    • /
    • 2021
  • Eye tracking research for upper limb disabilities is showing an effect in the aspect of device control. However, the reality is that it is not enough to perform web interaction with only eye tracking technology. In the Eye-Voice interface, a previous study, in order to solve the problem that the existing gaze tracking interfaces cause a malfunction of pointer execution, a gaze tracking interface supplemented with a voice command was proposed. In addition, the reduction of the malfunction rate of the pointer was confirmed through a comparison experiment with the existing interface. In this process, the difficulty of pointing due to the small size of the execution object in the web environment was identified as another important problem of malfunction. In this study, we propose an auto-magnification interface of objects so that people with upper extremities can freely click web contents by improving the problem that it was difficult to point and execute due to the high density of execution objects and their arrangements in web pages.

Spatial Information Search Features Shown in Eye Fixations and Saccades (시선의 고정과 도약에 나타난 공간정보 탐색 특성)

  • Kim, Jong-Ha
    • Korean Institute of Interior Design Journal
    • /
    • v.26 no.2
    • /
    • pp.22-32
    • /
    • 2017
  • This research is to analyze the spatial information search features which shown by Eye fixation and movement and conducted eye tracking experiment for targeting sports shop spatial images which it are same but looks different. This is able to find out the eye movement feature according to placement of goods from the eye movement and movement distance of spatial visitor, and the result can be defined as following. First, the whole original-reverse left / right images have a higher number of observations in the [IN] area than in the [OUT] area. This is because after eye taking high observations in LA area of [IN] have been jump-over [OUT], performed search activities in low eye fixation without high eye fixation. Second, there was a difference in the frequency of the observation data as the composition of the images changed. The original image has been often fixed the eyes in LA area, and the one that has been observed for a long time is reverse left / right image. Also, fixation point was shown higher at the reverse left / right image as jump-over from [OUT] area to [IN] area. If LA area seen as reverse left / right image, it is located in right-hand side. The case where the dominant area is on the right side has a characteristic that the eye fixation is longer. This can be understand that the arrangement of products for attract the customer's attention in the commercial space might be more effective when it is on the right side. Third, the moving distance(IN ${\rightarrow}$ OUT) of the sight pointed to external from LA area was long in the both original-reverse left / right images, but it is no relation with search direction([IN${\rightarrow}$OUT] [IN${\rightarrow}$OUT]) of the sight. In other words, the sight that entered in LA area can be seen as visual perception activity for re-searching after big jump-over, in the case go in to outward (OUT area) after searching for more than certain time. The fact that the moving distance of eye is relatively short in the [IN ${\rightarrow}$ OUT] process considered as that the gaze that stays outside the LA area naturally enters in to LA area.

The Clinical Tests for Treatment Improvement Comparison in Myopia between Eye Acupuncture Massage Machine (NURIEYE-1) and Acupuncture (경도근시(가성근시 포함) 환자에 있어 눈 경혈 마사지기와 침치료간의 증상개선 효과 비교를 위한 임상시험(단일기관, 무작위 배정))

  • Kim, Mi-Bo;Kim, Kyu-Kon;Hong, Sang-Hun;Ko, Woo-Shin;Yoon, Hwa-Jung
    • The Journal of Korean Medicine Ophthalmology and Otolaryngology and Dermatology
    • /
    • v.22 no.3
    • /
    • pp.80-94
    • /
    • 2009
  • Objective : The purpose of this clinical research is the investigation of the effects between acupuncture group(control group) and NURIEYE-1 group (experimental group) in myopia Methods : Comparison clinical study was conducted with the randomly arranged 32 patients for acupuncture group(control group) and NURIEYE-1 group(experimental group). For effectiveness evaluation, eye sight test, MQOL and DITI were tested three times with visits for every 4 weeks. With SAS, Statistical analysis was performed by using paired t-test and two sample t-test. Statistical significance was achieved with less than 5% probability (p<0.05). Result : 1. There was no significant effect from the eye sight comparison between the two group. We had improved results in average with MQOL, however, there was no statistical significance. Though there was also no significant result with DITI average comparison between two group, we witnessed significant effect in some part of MQOL. 2. Nevertheless Periodical comparison test showed weak significance with eye sight and DITI, significant effect was found in some part of MQOL. 3. With periodical comparison tests, there were significant effects in eye sight, MQOL and DITI with the experimental groups and control groups, respectively. Conclusion : There was no significant eye sight improvement. However, with acupuncture point stimulation, we think there are some positive effects for the relaxation of excessive stress in eyes.

  • PDF

Dose Assessment of the Eye of the Operator in the Field of Angiography and Interventional Radiography (혈관조영 및 중재적 시술 분야 내 종사자의 눈에 대한 선량평가)

  • Kim, Jung-hoon;Cho, Yong-In
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.2
    • /
    • pp.209-216
    • /
    • 2018
  • In the field of angiography and interventional radiology, it is said that the risk of radiation exposure to the eyes is high due to the characteristics of work, but currently divided dose assessment and management are not carried out in reality. Therefore, in this study, in order to evaluate the dose of the operator in the surgical environment and to analyze the shields, firstly, we selected the point where the operator is mainly located, evaluated the exposure dose of the eye after attaching the pocket dosimeter to the lateral angle point of the head and neck phantom, and evaluate shielding effect when wearing lead glasses that is currently commercialized. Secondly, we evaluated the tendency of the exposure dose of the eye and the shielding effect through simulation in the same geometric structure as the actual measurement. As a result, in the case of measurement using a dosimeter, the cumulative dose increased with the increase of the fluoroscopic time, and the tendency was different according to the position of the operator. Simulation results show that the dose distribution of the eye lens in the mathematical phantom is about 1.1 ~ 1.3 times higher than that of the cornea. Also, The protective effect of the lead glasses showed a shielding effect of at least 3.7 ~ 21.4% in each eye.

Guidelines for Free-Hand Aspiration(FHA) of Putaminal Hemorrhage (피각부 자발성 뇌내출혈의 혈종흡입술을 위한 지표)

  • Yim, Sin Gil;Oh, Min Suk;Lim, Jun Seob;Kang, Myung Gi;Kwak, Yeon Sang;Park, Seung Gyu;Song, Gyung Bae;Kim, Han Yung
    • Journal of Korean Neurosurgical Society
    • /
    • v.30 no.sup2
    • /
    • pp.294-299
    • /
    • 2001
  • Objectives : CT-guided stereotactic evacuation for spontaneous intracerebral hemorrhage can minimize the brain damage and can be performed safely and simply under local anesthesia. But that procedure is time consuming and has a risk of rebleeding because of the stress during head pin fixation. So authors describe easy and precise guidelines for FHA of putaminal hemorrhage without stereotactic instrument. Methods and Materials : We analyzed the data of 298 patients who underwent CT-guided stereotactic aspiration of putaminal hematoma in our hospital between January 1990 and December 2000. We divided the patients into three groups according to the location of hematoma : anterior portion, middle portion and posterior portion of putamen. Total number of catheters inserted into the hematoma were 345 and there were with regard to the direction and depth of catheters. Results : Proposed guidelines of catheter insertion to putaminal hemorrhage in our institution. 1) hematoma at the anterior portion of putamen ; Direction of catheter was the midpupillary line of the eye and the point intersecting a line drawn from the burr hole to a point between external auditory meatus(EOM) and 1cm posterior to EOM. Depth of catheter was 6-6.5cm. 2) hematoma at the middle portion of putamen ; Direction of catheter was the midpupillary line of the the eye and the point intersecting a line drawn from the burr hole to a point between 1cm and 2cm posterior to EOM. Depth of catheter was 6.5-7cm. 3) hematoma at the posterior portion of putamen ; Direction of catheter was 15 degree laterally from the midpupillary line of the eye and the point intersecting a line drawn from the burr hole to a point between 2cm and 3cm posterior to EOM. Depth of catheter was 7-7.5cm. We have performed FHA of putaminal hemorrhage in 48 cases according to this guideline. All catheter were inserted exactly at the center of hematoma and average operation time was about 30 minutes. Conclusion : Our proposed guidelines for putaminal hemorrhage are considered to be safe and simple method with similar accuracy and rapid decompression compared with traditional stereotactic method. Main advantages of this technique were unnecessity of stereotactic frame application and less time requirement for hematoma removal.

  • PDF

Electrical Budgets Measurements in PCI Express System (PCI Express 시스템의 전기 파라미터 측정)

  • Gwon, Won-Ok;Kim, Seong-Un
    • Electronics and Telecommunications Trends
    • /
    • v.22 no.4 s.106
    • /
    • pp.133-143
    • /
    • 2007
  • PCI Express는 고속 차동신호를 사용한 점대점(point-to-point) 프로토콜로 신호무결성(signal-integrity) 측정을 위해 기존의 병렬버스신호와 다른 파라미터(parameter)들이 사용되고 있다. PCI Express 시스템에서 중요한 전기 파라미터는 loss와 jitter이며 eye diagram을 통해서 분석이 가능하다. 본 고는 PCI Express 송수신 버퍼의 전기 규격과 애드인카드(add-in card) 시스템의 전기적 여유(budgets)의 의미와 분석을 다룬다. 또한 실제적인 PCI Express 시스템에서 전기 파라미터들을 측정하고 분석, 디버깅의 방법을 다룬다.

Design and Implementation of Real-time three dimensional Tracking system of gazing point (삼차원 응시 위치의 실 시간 추적 시스템 구현)

  • 김재한
    • Proceedings of the IEEK Conference
    • /
    • 2003.07c
    • /
    • pp.2605-2608
    • /
    • 2003
  • This paper presents design and implementation methods of the real-time three dimensional tracking system of the gazing point. The proposed method is based on three dimensional data processing of eye images in the 3D world coordinates. The system hardware consists of two conventional CCD cameras for acquisition of stereoscopic image and computer for processing. And in this paper, the advantages of the proposed algorithm and test results ate described.

  • PDF

Effects of Working Postures on Headache/Eye Strain in Korean Waged Workers: The 5th Working Condition Survey(2017) (근무자세가 두통/눈의 피로에 미치는 영향: 제5차 2017년 근로환경조사)

  • Kim, You Hyun;Koh, Seokjae;Cho, Kyung Min;Chae, Jinkyeong;Oh, Hyun Jung;Chang, Sei-Jin
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.32 no.2
    • /
    • pp.116-128
    • /
    • 2022
  • Objectives: The aim of this study was to examine the association of working posture with headache/eye strain in Korean waged workers. Methods: Data were collected from the 5th Korean Working Condition Survey. A total of 30,955 workers participated in this study. A four-items of working postures were measured using a 7-point Likert scale, and we categorized them into three groups ('normal', 'moderate', and 'severe') each 4 items. Headache/eye strain were measured using a self-administrative questionnaire ('yes' vs. 'no'). To examine the relationship between the total working postures score and headache/eye strain, we summed a 4-items of working postures. It was categorized into five groups according to the severity of exposures('normal', 'mild', 'moderate', 'severe', and 'very severe'). The multivariate logistic regression analysis was performed using the IBM SPSS(Ver. 25), and a p<.05 was considered significant. Results: The results show that 'fatiguing and painful posture' and 'posture repetitively using hands or arms' were associated with headache/eye strain after controlling for control variables. The total working posture score was positively associated with headache/eye strain. People with higher levels of the total working posture score were more likely to increase the risk of headache/eye strain compared to those of normal(OR: 1.844, 95% CI: 1.549~2.195 for 'mild'; OR: 2.564, 95% CI: 2.152~3.503 for 'moderate'; OR: 4.140, 95% CI: 3.432~4.994 for 'severe'; OR: 7.613, 95% CI: 5.625~10.304 for 'very severe') (p<.05 for trend). Conclusions: These results indicate that inappropriate working postures might play a crucial role in developing headache/eye strain. It is needed to improve the working environment, especially focusing on reducing inappropriate working posture at the organizational level.

Parafovea Information Processing of Adults and Adolescents in Reading: Diffusion Model Analysis on Distributions of Eye Fixation Durations (글읽기에서 나타난 성인과 청소년의 중심와주변 정보처리: 고정시간 분포에 대한 확산모형 분석)

  • Choo, Hyeree;Koh, Sungryong
    • Korean Journal of Cognitive Science
    • /
    • v.31 no.4
    • /
    • pp.103-136
    • /
    • 2020
  • This study compares the parafovea preview effect of adolescent group and adult group with different ages using eye tracking experiment. Also, this study confirms that the starting point parameter of the one boundary diffusion model can explain the data obtained through eye tracking experiments. In two experiments, parafoveal information processing was examined using the boundary technique. In Experiment 1, reading times were compared between the conditions given high frequency words preview versus masking preview. In Experiment 2, the condition in which low frequency words were given to parafovea preview information and the condition in which parafovea preview was masked were compared. We found that both the adolescent group and the adult group showed a parafovea preview effect. Also, first fixation, single fixation, and gaze duration of the two groups were different based on the word property shown in the parafovea. The first fixation data obtained in the two experiments were divided into quantiles and fitted into one boundary diffusion model. From the results, we argue that the parafovea preview information processing in the reading was described as the starting point parameter of the one boundary diffusion model.

A Study on the Face Image to Shape Differences and Make up (얼굴의 형태적 특성과 메이크업에 의한 얼굴 이미지 연구)

  • Song, Mi-Young;Park, Oak-Reon;Lee, Young-Ju
    • Korean Journal of Human Ecology
    • /
    • v.14 no.1
    • /
    • pp.143-153
    • /
    • 2005
  • The purpose of this research is to study face images according to the difference of facial shape and make-up. A variety of face images can be formulated by computer graphic simulation, combining numerously different facial shapes and make-up styles. In order to check out the diverse images by make-up styles, we applied five forms of eye brows, two types of eye shadows, and three lip shapes to the round-shaped face of a model. The question sheet, used with a operational stimulant in the experiment, contained 28 articles, composed of a pair of bi-ended adjective in 7 point scale. Data were analyzed using Varimax perpendicular rotation method, Duncan's Multiple Range Test, and Three-way ANOVA. After comparing various results of make-up application to various face types, we could find that facial shape, eye-brows, eye-shadow, and lip shapes influence interactively on total facial images. As a result of make-up image perception analyses, a factor structure was divided into mildness, modernness, elegance, and sociableness. Speaking of make-up image in terms of those factors, round form make-up style showed the highest level of mildness. Upward and straight style of make-up had the highest of modernness. Elegance level went highest when eye shadow style was round form and lip style was straight. Lastly, an incurve lip make-up style showed the highest of sociableness.

  • PDF