• Title/Summary/Keyword: Eye contact

Search Result 211, Processing Time 0.026 seconds

A Study for Rationalization of Lifting Lug Design of Ship Block (선박블록 탑재용 러그구조의 설계합리화를 위한 연구)

  • 함주혁
    • Journal of Ocean Engineering and Technology
    • /
    • v.11 no.4
    • /
    • pp.249-261
    • /
    • 1997
  • A basic study on the lifting lug design has performed through the rational and systematic process. In order to evaluate the proper design-load distribution around lug eye investigation of contact force between lifting lug and shackle pin is performed using non-linear parametric analysis idealized by gap element models. Gap element modeling and nonlinear analysis procedures are illustrated and discussed based on MSC/NASTRAN. Some analysis and design guides are suggested through the consideration of several important effects such as stress distribution pattern, circumferential contact force distribution along the lug eye face, loading share rate between lug main plate and doubler, effect of loading direction, relation between applied force and deflection and size effect of shackle pin radius. Additionally optimum design studies are performed and general trends according to the variation of design parameters are suggested.

  • PDF

Comparisons of the Change in Soft Contact Lenses Parameters and the Cleaning Efficiency after Eyeliner Deposition (아이라이너 침착에 의한 소프트 콘택트렌즈 파라미터의 변화 및 세척효과의 비교)

  • Park, Mijung;Kim, Sa Hyun;Ku, Bo Kyoung;Kim, So Ra
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.18 no.2
    • /
    • pp.107-115
    • /
    • 2013
  • Purpose: This study was conducted to investigate the change of soft contact lens parameters after eyeliner deposition and compare the cleaning efficiency and the recovery rate of lens parameters by different cleaning methods. Methods: The eyeliner was deposited on three types of soft contact lenses made of different materials for 1 hour, 4 hours and 6 hours and those lenses were washed by the eyeglasses ultrasonic cleaning and by hands. The changes in visible light transmittance, diameter and surface of those lenses were compared before and after cleaning of the lens. Results: The visible light transmittance of soft contact lenses decreased along with the deposition time of eyeliner. The patterns of the eyeliner deposition on soft contact lens appeared differently depending on the physical properties of the lens material. Thus, the largest eyeliner deposition was found on narafilcon A lens. The diameters of hilafilcon B and etafilcon A lenses were decreased, however, the diameter of narafilcon A lens was increased. The cleaning efficiency of the eyeliner deposition was greater with the multipurpose solution by hands than with the eyeglasses ultrasonic cleaner. However, the recovery of lens parameters such as the lens diameter, visible light transmittance and lens surface due to the eyeliner deposition to its original state was limited. Conclusions: From these results, it is suggested to minimize eye makeup when wearing soft contact lens. Furthermore, the reduced wearing time and shorter cycle of lens replacement may be needed by considering a change of lens parameter when the repeat eye makeup is applied.

Comparison of Accommodative Response among Emmetropes, Spectacle and Contact Lens Wearer (정시, 안경 및 콘택트렌즈 착용자의 조절반응량 비교)

  • Lee, Kyu-Byung;Park, Jeehyun;Kim, Hyojin
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.17 no.4
    • /
    • pp.403-410
    • /
    • 2012
  • Purpose: The purposes of this study are to investigate accommodative response among emmetropes, spectacle wearer and contact lens wearer, and correlation between refractive error and accommodative respons for each group. Methods: The 72 subjects(144 eyes) who do not have any ocular diseases were participate in this study. Subjects were categorized into emmetropes, spectacle wearer and contact lens wearer by refractive error using closed-field auto-refractometer. We measured dominant eye, naked/habitual visual acuity and refractive error of monocular/binocular vision of refractive error for far/near distance with open-field auto-refractometer and calculated accommodative lag. Results: There were no significant difference of accommodative lag between right and left eye dominant and non-dominant eye, monocular and binocular vision, and spectacle lens wearer and contact lens wearer, However the accommodative lag of binocular vision was severe than monocular vision at near. The lag of myopia was larger than emmetropes, and male was larger than female. Significant correlation was found between refractive error and accommodative lag in total subjects and the same result was found in emmetropes and contact lens wearer. However there were no significant correlation in the spectacle wearer. Conclusions: There were significant difference between emmetrops and myopes in terms of accommodative lag, however accommodative lag of spectacle wearer was not different with contact lens wearer in myopes. There were also significant correlation between refractive error and accommodative lag in emmetropes and contact lens wearer, but the accommodative lag of spectacle wearer was not significantly correlated with refractive error.

Comparative Performance Evaluations of Eye Detection algorithm (눈 검출 알고리즘에 대한 성능 비교 연구)

  • Gwon, Su-Yeong;Cho, Chul-Woo;Lee, Won-Oh;Lee, Hyeon-Chang;Park, Kang-Ryoung;Lee, Hee-Kyung;Cha, Ji-Hun
    • Journal of Korea Multimedia Society
    • /
    • v.15 no.6
    • /
    • pp.722-730
    • /
    • 2012
  • Recently, eye image information has been widely used for iris recognition or gaze detection in biometrics or human computer interaction. According as long distance camera-based system is increasing for user's convenience, the noises such as eyebrow, forehead and skin areas which can degrade the accuracy of eye detection are included in the captured image. And fast processing speed is also required in this system in addition to the high accuracy of eye detection. So, we compared the most widely used algorithms for eye detection such as AdaBoost eye detection algorithm, adaptive template matching+AdaBoost algorithm, CAMShift+AdaBoost algorithm and rapid eye detection method. And these methods were compared with images including light changes, naive eye and the cases wearing contact lens or eyeglasses in terms of accuracy and processing speed.

Product Analysis and Development of Amblyopia Eye Patch for Children

  • Lim, Hosun;Sung, Juyoung
    • Fashion, Industry and Education
    • /
    • v.14 no.2
    • /
    • pp.1-10
    • /
    • 2016
  • In the present study, the materials, sizes, and designs of blind eye patch products of skin-adhesive type and glass-attachment type currently available in the market will be analyzed and ergonomically appropriate blind eye patches will be developed. Although these skin-adhesive type eye patches were easy to use, they had shortcomings such as skin troubles due to the adhesive used on the weak and sensitive skin of children and the fact that eyebrows are pulled out and the skin is irritated when the eye patches are detached after being attached. The non-adhesive type eye patches were blind patches to be worn by putting into glasses. These products were made using diverse materials such as neoprene, non-woven fabrics, and felt and showed differences in tactile impressions and irritation to the skin depending on material characteristics. In addition, most products were efficient in blocking light with three-dimensional oval designs comprising darts. In the present study, blind eye patches were designed to reduce skin troubles by using sweat-absorbing and quick-drying functional materials with soft tactile impressions. In addition, to increase the effect to block light and the degree of tight contact with the skin when the blind eye patches are worn compared to existing eye patch designs, the sides of the wings of the blind eye patches were widened, glass frame fixing plates were added, and the darts were made to be curved thereby making an ergonomic design reflecting the shape of the face. The non-adhesive type blind eye patches developed in the present study are considered to enhance the wearing sensation with the use of the material without skin irritation but with cushioning feelings and the ergonomic design reflecting the contour of the face.

Changes in Optical and Surface Properties of Contaminated Soft Contact Lenses (표면 오염시 소프트콘택트렌즈의 재질에 따른 가시광선투과도 및 표면 변화)

  • Kim, Jungeun;Jung, Boyoung;Noh, Hyeran
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.17 no.1
    • /
    • pp.83-89
    • /
    • 2012
  • Purpose: This article was to study the optical and surface properties of soft contact lenses (SCL) exposed to eye make-ups. Methods: Rates of the light transmission of etafilcon A (HEMA based hydrogel lens) and lotrafilcon B (silicone based hydrogel lens) exposed to four different cosmetics over time were investigated. After cleansed with multi-purpose solution (MPS), rates of the light transmission and surface change of lens that were exposed to the cosmetics for 7 consecutive days were analyzed. Results: Visible light transmissions of all lenses exposed to cosmetics decreased to 93.35% (HEMA based hydrogel lens) and 90% (silicone based hydrogel lens) compared with those of the fresh SCLs, such as 97.8% and 96.4%, respectively. It was found that cosmetic residues from powder eye shadow and mascara attached to the lenses were not removed completely when cleansed with MPS. Especially with silicone based hydrogel lens, we found a decrease in visible light transmission of the lens and noticeable particles on lens surface imaged by SEM. Conclusions: Depending on types of eye make-ups and contact lens materials, make-ups were not completely eliminated with current cleansing methods and that caused a decrease in optical property and a change in surface property of the lenses.

Patient′s Preferances for Nurse′s Nonverbal Expressions of Warmth During Nursing Rounds and Administration of Oral Medication (간호회진과 경구투약시 환자가 선호하는 간호사의 비언어적 온정행위에 관한 연구)

  • 김형선;김문실
    • Journal of Korean Academy of Nursing
    • /
    • v.20 no.3
    • /
    • pp.381-398
    • /
    • 1990
  • Nursing involves deep human interpersonal relationships between nurses and patients. But in modem Korea, the nurse - patient relationship tends to be ritualistic and mechanestic. Patients usually express the hope that nurses be more tender and kind. Patients expect nurses to express their warmth especially through nonverbal behaviour. This study was conducted to identify patients' preferences for nurse's nonverbal expressions of warmth. Through the confirmation of these preferences, nurses may learn how to enhance their interpersonal relationships with patients. Subjects for the study were 73 patients who had been admitted to a university teaching hospital for at least three days and agreed to be interviewed by the investigator. The interactions were studied nonverbal expressions of warmth during nursing rounds and administration of oral medication. The interview schedule was expecially designed by the investigator to measure the nurse's posture, the distance between the nurse and the patient, the nurse's eye contact, facial expression, hand motion and head nodding. Data analysis included frequencies, percentages and X²-test. The results of this study may be summerized as follows : 1. Patient's preferences for nurse's nonverbal expressions of warmth during nursing rounds. Preferred nurse's posture was sitting(50.7%) or standing(49.3%) opposite the patient. Preferred distance between the nurse and the patient was close to the bed(93.2%), less than 1m. Preferred eye contact was directed to the patient's eyes or their affected part (41.1%). Preferred facial expression was a smile(97.3%). Preferred hand motions were light gestures(41.1%). Patients preferred head nodding which approved their own opinions(69.9%). 2. Patient's preferences for nurse's nonverval expressions of warmth during administration of oral medication. Preferred nurse's posture was standing and waiting to confirm that the medication had been taken(58.9%). Preferred distance from the patient was at arm's length, 0.5-1m(64.4%). Patients preferred direct eye contact(58.9%) and a smile(94.5%). Patients preferred that the nurse put the medicine directly the patient's hand(64.4%). Whether the nurse nodded her head or not was not considered important. 3. The relation of general characteristics and patient's preferences for nurse's nonverbal expressions of warmth during nursing rounds and administration of oral medication. During nursing rounds, the age of subjects(p=0.010) and the standard of education(p=0.026) related to the distance between the nurse and the patient. The sick hospital ward related to the eye contact(p=0.017) and facial expression(p=0.010). During administration of oral medication, the age of subjects(p=0.044) and days of hospital treatment (p=0.043) and the sick hospital ward(p=0.0004) related to the facial expression. From this study, nurses can learn what kind nonverbal expressions of warmth are preferred by patients during rounds and administration and thus will enhance nurse- patient interpersonal relationships.

  • PDF

Acute Effects of Prolonged 15minnute Static Stretching on Foot Contact Area Surface and Foot Pressure Changed in Young Adults (15분간의 지속적인 스트레칭이 족저압과 족저면적 변화에 미치는 영향)

  • Kuk, Jung-Seok
    • Journal of Korean Physical Therapy Science
    • /
    • v.18 no.4
    • /
    • pp.59-64
    • /
    • 2011
  • Purpose : The purpose of this study was to evaluate the effects of the stretching of the calf muscles on foot pressure and contact area in young adult. Participants stood on a wedge board that was sloped between 15~25 degree for 15min. After stretching participants stood quietly on force plate, result was recorded. Participants stood on a force plate for 1 min in eye closed condition, and them the foot pressure and area was recorded. The following variables were calculated off-line: anterior and posterior foot pressure and contact area, medial and lateral foot pressure and contact area. Results showed that anterior pressure change due to stretch, but mediolateral was not significant. This result suggested that stretching of the calf muscle has the effect of increasing anterior pressure by flexibility change on calf muscle, so this effects might be effective intervention for reduce of serious problem to neurologic patients in therapy session.

  • PDF

A Study of Navajo Textiles in the Transitional Period (19세기후반 전환시대 Navajo 인디언직물의 고찰)

  • 정미실
    • Journal of the Korean Home Economics Association
    • /
    • v.40 no.8
    • /
    • pp.37-48
    • /
    • 2002
  • The purpose of this study was to survey Navajo's textiles of the transitional period(1868-1890) and to examine appearance background of those textiles. The two study questions were central to the project. 1) What were characteristics of eye-dazzler and pictorial in the transitional period? 2) How developed was the American trader's role? To perform the purpose, literatures on this subject were surveyed, investigation of textiles in Arizona State Museum and Historical Museum of Arizona were accomplished. The results of this study were as follows: 1. Eye-dazzler is called because of their small, serrate triangle and diamond patterns in intense, contrasting colors. Eye-dazzler mostly used Germantown yam and wedge-weave technique. Germantown was a plied yam colored with synthetic dyes. Wedge-weave technique used optical illusions and an undulating technique to create an effect of motion and rhythmic symmetry. 2. The Americans began to intern Navajos at Bosque Redondo, New Mexico in 1863. During their stay at Bosque Redondo, the Navajo came into greater contact with Rio Grande blankets. The influence of designs of these becomes increasingly important in the eye-dazzler. 3. Pictorial materials included rich new sources the railroad provided and living environment of animals, plants, hogans, neighbors, deities that interested the Navajo. Also, sandpainting textiles were a pictorial. Three types of textiles utilized: yei, yeibichai, and sandpainting tapestry. 4. The arrival of the railroad caused many changes for the lives and textiles of the Navajos. The railroad brought a new client into the Navajo, and the Navajos attempted new textiles with design-inspiring fresh materials to adjust taste of the eastern purchasers.

Development of Eye-Tracking System Using Dual Machine Learning Structure (이중 기계학습 구조를 이용한 안구이동추적 기술개발)

  • Gang, Gyeong Woo;Min, Chul Hong;Kim, Tae Seon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.7
    • /
    • pp.1111-1116
    • /
    • 2017
  • In this paper, we developed bio-signal based eye tracking system using electrooculogram (EOG) and electromyogram (EMG) which measured simultaneously from same electrodes. In this system, eye gazing position can be estimated using EOG signal and we can use EMG signal at the same time for additional command control interface. For EOG signal processing, PLA algorithms are applied to reduce processing complexity but still it can guarantee less than 0.2 seconds of reaction delay time. Also, we developed dual machine learning structure and it showed robust and enhanced tracking performances. Compare to conventional EOG based eye tracking system, developed system requires relatively light hardware system specification with only two skin contact electrodes on both sides of temples and it has advantages on application to mobile equipments or wearable devices. Developed system can provide a different UX for consumers and especially it would be helpful to disabled persons with application to orthotics for those of quadriplegia or communication tools for those of intellectual disabilities.