• Title/Summary/Keyword: Eye blinking

Search Result 51, Processing Time 0.03 seconds

Model on the Contact Lens Movement from Eye-lid Blinking (순목 작용에 의한 콘택트 렌즈의 운동 모델)

  • Kim, Daesoo
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.9 no.1
    • /
    • pp.145-159
    • /
    • 2004
  • A mathematical model and its computer solution program were proposed to analyze the motion of contact lenses which are being subject to lid-blinking. The equation was derived by incorporating an acceleration induced lid's force exerting on the contact lens, the viscous damping resistance in the tear layer beneath the lens and the sliding frictional force between the lid and the contact lens surface into the formulation of differential equation describing the vibration. The model predicts the time-dependent displacement from the equilibrium postion during/after the blinking. During the blinking, as the time for the completion of one cycle of blinking decreases the off-the-equilibrium displacement of contact lens increases while the decrease of diameter in the contact cause the opposite effect. It is found that lid pressure exerting on the lens cause an insignificant lens displacement from the equilibrium position. After blinking the frequency of damped oscillation of contact lens decreases as the diameter of lens increases, due to the incresed surface while the reduced blinking time does not cause a significant frequency change. This is because that driving force for the contact lens movement posterior to blinking is the capillary-induced force not the lid force.

  • PDF

Comparison of Blinking Patterns When Watching Ultra-high Definition Television: Normal versus Dry Eyes (초고선명 텔레비전 시청 시 정상안과 건성안에서의 눈깜박임 양상 비교)

  • Kang, Byeong Soo;Seo, Min Won;Yang, Hee Kyung;Seo, Jong Mo;Lee, Sanghoon;Hwang, Jeong-Min
    • Journal of The Korean Ophthalmological Society
    • /
    • v.58 no.6
    • /
    • pp.706-711
    • /
    • 2017
  • Purpose: To analyze blinking patterns when watching an ultra-high definition (UHD) television and to compare the results between normal eyes and dry eyes. Methods: A total of 59 participants aged from 13 to 69 years were instructed to watch a colorful and dynamic video on a UHD television for 10 minutes. Before and after watching the UHD television, we measured the best corrected visual acuities, autorefraction, tear-break-up-time, degree of corneal erosion and conjunctival hyperemia via slit lamp biomicroscopy. In addition, questionnaires for the evaluation of eye fatigue and symptoms of a dry eye were completed. The definition of dry eye syndrome was that the tear-break-up-time of one of the eyes was less than 5 seconds, conjunctival injection, or marked corneal erosion. The number of blinks and the duration of blinking were both measured and analyzed at the early and late phases of video-watching. Results: After watching the UHD television in the normal eye group, the tear-break-up-time was significantly decreased (p < 0.001) and the degree of corneal erosion was significantly increased (p = 0.023). However, the subjective symptoms of participants were not aggravated (p = 0.080). There were no significant differences in blinking patterns in the dry eye group. On the other hand, in the normal eye group, the mean blinking time was significantly increased (p = 0.030). Conclusions: Watching an UHD television changes the tear-break-up-time, degree of corneal erosion, and blinking pattern in normal eyes, which may increase the risk of dry eye syndrome.

The characteristic analysis of EEG artifacts (EEG 잡파 특성 분석)

  • Yang, Eun-Joo;Shin, Dong-Sun;Kim, Eung-Soo
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.12 no.4
    • /
    • pp.366-372
    • /
    • 2002
  • EEG is the electrical signal, which is occurred during information processing in the brain. These EEG signal are measured by non-invasive method. EEG has many useful information for brain activity, but artifacts which are included in EEG prevents EEG analysis, so many efforts are devoted to remove these artifacts in EEG. However, this study is going to analysis the feature of the EEG mixed with artifacts in forward-looking way, by using this way, we have found the possibility that is actually applicable to system such as control system. We have made feature difference after the linear as well as nonlinear analysis regarding EEG including typical artifacts, eye-blinking, eye rolling, muscle, and so forth.

The improvement of moving picture quality in TFT-LCD with Blinking Backlight System and Liquid Crystal Overdriving Methode (Blinking Backlight System과 Liquid Crystal Overdriving Methode를 사용한 TFT-LCD의 동영상 화질개선을 위한 연구)

  • Han, Jung-Min;Kim, Jong-Hwan;Kim, Young-Hwan;Kim, Gwi-Yeol;Seo, Dae-Shik
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.05a
    • /
    • pp.146-149
    • /
    • 2005
  • In applying LCD to TV application, one of the most significant factors to be improved is image sticking on the moving picture. LCD is different from CRT in the sense that it's continuous passive device, whichholds images in entire frame period, while impulsetype device generate image in very short time. We realized articulate image generation similar to CRT by CCFL blinking drive and TN-LCD overdriving. As a result, reduced image sticking phenomenon was validated by naked eye and response time measureme.

  • PDF

Evaluation of Flow Experience by using Psychophysiological Visual Feedbacks

  • Kim, Jung Yong;Min, Seung Nam;Park, Yong Duck
    • Journal of the Ergonomics Society of Korea
    • /
    • v.32 no.6
    • /
    • pp.481-487
    • /
    • 2013
  • Objective: The present study aims to evaluate the visual reactions of users when they are playing games of different flow levels, and to explore the visual variables that can sensitively reflect the different flow levels. Background: The flow is defined as a psychological state where interface users feel their actions in a virtual setting identical to those in real environment. To measure the flow states of users, the questionnaire-based FSS(Flow State Scale) has mostly been used. However, this method is a qualitative test that has limits in terms of the accuracy of users' flow experiences. Therefore, more accurate methods to measure users' flow experiences are required. Method: Ten subjects participated in the experiment, where the independent variables were three games with different flow levels(puzzle games, dot drawing and coloring) and the time frame(the first and last 10 seconds in game playing), whereas the dependent variables included the pupil size and the frequency and duration of eye blinking. This study was a within-subject design. Each participant performed three types of games with different flow levels 3 times for each for 10 minutes, and their visual reactions to each game were measured. Results: The higher the flow cause the bigger pupil size(p<0.01) and the lower eye blinking frequency(p<0.1), indicating that different types of games lead to different flow levels. The pupil size during the last 10 seconds when the flow level was higher was bigger by 2.1% compared with that during the first 10 seconds in game playing(p<0.1), and the eye blinking frequency decreased by 12%(p<0.01). Conclusion: It was found out that the pupil size and the frequency and duration of eye blinking were psychophysiological indices for evaluating users' flow experiences, which could quantify the flow states users go through. The psychophysiological variables capable of measuring diverse aspects of the flow need diversifying to be applicable to precise measurement of the flow. Application: These studies are warranted for both quantitative analysis of flow levels and qualitative improvement of cyber leisure in line with development of healthy games.

Clinical Observation on 3 Cases of Dry Eye Syndrome (안구 건조증 환자의 치험 3례)

  • Choi, Eun-Hee;Jeon, Ju-Hyun;Kim, Young-Il
    • Journal of Acupuncture Research
    • /
    • v.24 no.4
    • /
    • pp.237-245
    • /
    • 2007
  • Objective : The Dry Eye Syndrome is characterized by reduction of the stability of the tearfilm and a set of alterations of the eye surface which could relate to tear quality, normal makeup of tearfilm and alterations in blinking or regular closing of eyelids. We treated 3 patients who was suffering with severe Dry Eye Syndrome and assessed the effectiveness of Oriental Medicine in the treatment of Dry Eye Syndrome. Methods : The patients were treated by acupunture, Gi Guk Yang Hyeol-decoction(Qijuyangxie-decoction). The improvement of the symptom was judged the subjective symptoms by the change of Ocular Surface Disease Index. Result : We observed in 2 cases of the patient significant decrease in the frequency of subjective symptoms, 1 case was not treated. Conclusion: The Oriental Medicine had effective results in Dry Eye syndrome. We need to have more observation and examination of Dry Eye syndrome.

  • PDF

Characteristics of Motion-blur Free TFT-LCD using Short Persistent CCFL in Blinking Backlight Driving

  • Han, Jeong-Min;Ok, Chul-Ho;Hwang, Jeoung-Yeon;Seo, Dae-Shik
    • Transactions on Electrical and Electronic Materials
    • /
    • v.8 no.4
    • /
    • pp.166-169
    • /
    • 2007
  • In applying LCD to TV application, one of the most significant factors to be improved is image sticking on the moving picture. LCD is different from CRT in the sense that it's continuous passive device, which holds images in entire frame period, while impulse type device generate image in very short time. To reduce image sticking problem related to hold type display mode, we made an experiment to drive TN-LCD like CRT. We made articulate images by turn on-off backlight, and we realized the ratio of Back Light on-off time by counting between on time and off time for video signal input during 1 frame (16.7 ms). Conventional CCFL (cold cathode fluorescent lamp) cannot follow fast on-off speed, so we evaluated new fluorescent substances of light source to improve residual light characteristic of CCFL. We realized articulate image generation similar to CRT by CCFL blinking drive and TN-LCD overdriving. As a result, reduced image sticking phenomenon was validated by naked eye and response time measurement.

A Method to Identify the Identification Eye Status for Drowsiness Monitoring System (졸음 방지 시스템을 위한 눈 개폐 상태 판단 방법)

  • Lee, Juhyeon;Yoo, Hyoungsuk
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.12
    • /
    • pp.1667-1670
    • /
    • 2014
  • This paper describes a method for detecting the pupil region and identification of the eye status for driver drowsiness detection system. This program detects a driver's face and eyes using viola-jones face detection algorithm and extracts the pupil area by utilizing mean values of each row and column on the eye area. The proposed method uses binary images and the number of black pixels to identify the eye status. Experimental results showed that the accuracy of classification eye status(open/close) was above 90%.

A survey on the visual fatigue measurement methods (시각피로의 측정방법에 관한 조사연구)

  • 이남식;박재희;김유창
    • Proceedings of the ESK Conference
    • /
    • 1994.04a
    • /
    • pp.32-37
    • /
    • 1994
  • This paper surveys the various methodologies for the objective measurement of visual fatigue. Visual fatigue is a psychophysiological symtom caused by the excessive use of eyes and it can be used as an important measure of the effectiveness and the safety of visual displays. The purpose of this paper is to compare the various visual fatigue measurement methodologies in a sense of the suitability for the ergonomic research. The measurement methodologies based on accommodation, convergence, visual evoked potential, eye movement, eye blinking, and flicker fusion were discussed and compared.

  • PDF