DOI QR코드

DOI QR Code

Comparison of Blinking Patterns When Watching Ultra-high Definition Television: Normal versus Dry Eyes

초고선명 텔레비전 시청 시 정상안과 건성안에서의 눈깜박임 양상 비교

  • Kang, Byeong Soo (Department of Ophthalmology, Seoul National University College of Medicine) ;
  • Seo, Min Won (Department of Electrical and Computer Engineering, Seoul National University College of Engineering) ;
  • Yang, Hee Kyung (Department of Ophthalmology, Seoul National University College of Medicine) ;
  • Seo, Jong Mo (Department of Ophthalmology, Seoul National University College of Medicine) ;
  • Lee, Sanghoon (Department of Electrical and Electronic Engineering, Yonsei University College of Engineering) ;
  • Hwang, Jeong-Min (Department of Ophthalmology, Seoul National University College of Medicine)
  • 강병수 (서울대학교 의과대학 안과학교실) ;
  • 서민원 (서울대학교 공과대학 전기.정보공학부) ;
  • 양희경 (서울대학교 의과대학 안과학교실) ;
  • 서종모 (서울대학교 의과대학 안과학교실) ;
  • 이상훈 (연세대학교 공과대학 전기전자공학부) ;
  • 황정민 (서울대학교 의과대학 안과학교실)
  • Received : 2016.10.06
  • Accepted : 2017.05.17
  • Published : 2017.06.15

Abstract

Purpose: To analyze blinking patterns when watching an ultra-high definition (UHD) television and to compare the results between normal eyes and dry eyes. Methods: A total of 59 participants aged from 13 to 69 years were instructed to watch a colorful and dynamic video on a UHD television for 10 minutes. Before and after watching the UHD television, we measured the best corrected visual acuities, autorefraction, tear-break-up-time, degree of corneal erosion and conjunctival hyperemia via slit lamp biomicroscopy. In addition, questionnaires for the evaluation of eye fatigue and symptoms of a dry eye were completed. The definition of dry eye syndrome was that the tear-break-up-time of one of the eyes was less than 5 seconds, conjunctival injection, or marked corneal erosion. The number of blinks and the duration of blinking were both measured and analyzed at the early and late phases of video-watching. Results: After watching the UHD television in the normal eye group, the tear-break-up-time was significantly decreased (p < 0.001) and the degree of corneal erosion was significantly increased (p = 0.023). However, the subjective symptoms of participants were not aggravated (p = 0.080). There were no significant differences in blinking patterns in the dry eye group. On the other hand, in the normal eye group, the mean blinking time was significantly increased (p = 0.030). Conclusions: Watching an UHD television changes the tear-break-up-time, degree of corneal erosion, and blinking pattern in normal eyes, which may increase the risk of dry eye syndrome.

목적: 초고선명 화질의 화면 시청이 눈깜박임 양상에 미치는 영향을 알아보고, 건성안과 정상안에서 눈깜박임이 어떻게 다른지 비교하고자 하였다. 대상과 방법: 만 13-69세 남녀 59명(118안)을 대상으로 초고선명 텔레비전의 채도가 높고 움직임이 큰 영상을 10분 동안 시청하도록 하였다. 시청 전후 각각 최대교정시력, 자동굴절검사, 세극등검사로 평가한 눈물막 파괴시간, 각막염색 정도, 결막 충혈 정도를 조사하였고, 이와 함께 눈의 피로도 또는 건성안 증상 평가를 위한 설문조사를 함께 시행하였다. 눈물막 파괴시간이 양안 중 하나라도 5초 이하이거나 결막 충혈이 경도 이상으로 있거나, 각막미란이 뚜렷하게 있을 때를 건성안으로 정의하였고, 시청 초반과 후반에 각각 눈깜박임 횟수 및 시간 등을 영상 분석을 통해 측정하였다. 결과: 정상안군에서 영상을 시청한 후 평균 눈물막 파괴시간이 감소하고(p<0.001), 평균 각막미란 정도도 심해졌지만(p=0.023), 피검사자가 느끼는 주관적 눈의 피로도 및 건성안 증상은 변화가 없었다(p=0.080). 건성안군에서는 눈깜박임 양상이 시청 초기와 후기에 통계적으로 유의한 차이를 보이지 않았으나, 정상안군에서는 시청 초기에 비해 후기에 통계적으로 유의하게 평균 깜박임 시간이 증가하였다(p=0.030). 결론: 초고선명 텔레비전 시청은 정상안에서 눈물막 파괴시간과 각막미란 정도에 영향을 주며, 눈깜박임 변화를 초래하여 건성안 발생 위험을 높일 수 있겠다.

Keywords

Acknowledgement

Grant : Research on Human Safety and Contents Quality Assessment for Realistic Broadcasting

Supported by : Institute for Information and communications technology promotion