• 제목/요약/키워드: Extinguishing Test

검색결과 104건 처리시간 0.025초

탠덤형 자석 소호기를 사용한 760V급 직류 개폐기의 차단 특성 (760 V-Class DC Switch Breaking Characteristics Using Tandem Type Magnet Extinguisher)

  • 김효성
    • 전력전자학회논문지
    • /
    • 제27권3호
    • /
    • pp.175-179
    • /
    • 2022
  • Magnetic arc extinguishing technology is effective as an extinguishing device for low-voltage direct current (DC) circuit breakers with a resistive load of ≤4 kW. The separation distance between the magnet and the electrical contact must be shortened to increase the magnetic arc extinguishing force. However, if the magnet is installed too close to the electrical contact points, the magnet is exposed to high temperatures due to the arc current generated when the load current is cut off and the magnetism is lost. To solve this problem, the effective magnetic flux density at the electrical contact can be maintained high by placing the arc extinguishing magnet in a tandem structure with the electrical contact point between them, and the proper separation distance between the contact points and the magnet can be maintained. In addition, an electric arc extinguishing technology that emits arc energy using a series circuit of diode and resistor is used to suppress the continuous arc voltage generated by the inductive load. For the proposed circuit breaker, the breaking characteristics are analyzed through the breaking test for the DC load of the 760 V level, the load power of 4 kW, and the time constant of 5 ms, and an appropriate arc extinguishing design guideline is proposed.

금속화재 대응 시 간이소화용구 및 약제의 소화 효과성 분석 (Effectiveness Analysis of Fire Extinguishing Agents for Metal Waste Fires)

  • 권진석;김수영;김태선;박태희;김태동;박민영
    • 한국재난정보학회 논문집
    • /
    • 제19권3호
    • /
    • pp.644-655
    • /
    • 2023
  • 연구목적: 금속의 취급 및 가공 공장과 금속폐기물 저장 공장 등에서 금속이 포함된 화재가 빈번하게 발생하고 있다. 금속화재의 경우는 소화가 어렵고 장시간 소요되므로 대응 시 주의가 필요하다. 본 연구에서는 금속화재의 발생 현황과 문제점 등을 제시하고 국내에서 사용중인 간이소화용구와 약제에 대한 실험을 통해 효과성을 도출하였다. 연구방법: ISO7165의 D급소화기 실험 중 분말 형태의 실험을 준용하여 순도 99.9%, 입자 150 ㎛ 이상의 마그네슘을 착화하여 5가지 간이소화용구, 소화기 및 약제에 대한 비교실험을 하였다. 연구결과: 간이소화용구로는 국내에서 가장 많이 사용되는 건조사와 팽창질석, 사용성 검증이 필요한 황토가루를 사용하였고, 국외에서 인증받아 사용중인 D급 소화기와 국내 금속화재 현장에서 사용된 액상의 수산화실리카를 사용하였다. 결론: 본 실험을 통해 소화효과성과 사용편의성, 경제성 측면을 고려한 결과, 팽창질석이 금속 화재 시 가장 적절한 것으로 도출되었다.

실규모 심부화재 소화특성에 관한 연구 (A Study of Fire Extinguishment Characteristic for the Real Scale Deap-Seated Fire)

  • 김남균;이동호
    • 한국화재소방학회논문지
    • /
    • 제29권2호
    • /
    • pp.13-19
    • /
    • 2015
  • 본 연구는 침윤소화약제의 소화성능평가를 위해 실규모 소화실험을 수행하였다. 실험은 '수동식소화기의 형식승인 및 검정기술기준'에 명시되어 있는 A급 소화실험 방법에 따라 진행하였으며, 목재 외에도 목분과 왕겨를 대상으로 실험을 진행하였다. 소화용수는 물과 국내에서 사용되고 있는 3종의 침윤소화약제를 사용하여 성능평가 실험을 진행함으로써 물과 침윤소화약제의 명확한 변별력을 확인하고자 하였다. 실험 결과 물의 경우에서 내부 온도의 유지시간이 길게 유지되고 침윤소화약제의 경우 빠른 온도 하강을 나타냄을 확인하였으며, 시간에 따른 온도분포를 통해 소화능력의 변별력을 확인하였다. 본 실험 결과를 바탕으로 추후 최적화 침윤소화약제 성능평가 방법을 제시하는데 기초자료로 활용할 수 있을 것으로 판단된다.

축소모형 실험을 통한 침윤소화약제 소화성능 평가 (Wetting Agent Performance Evaluation Using Scale Model)

  • 김남균;임경범;이동호
    • 한국화재소방학회논문지
    • /
    • 제28권2호
    • /
    • pp.20-25
    • /
    • 2014
  • 본 연구는 자체제작 축소모형 실험 장치를 이용하여 목재를 대상으로 침윤소화약제의 소화성능평가를 수행하였다. 축소모형실험의 최적조건 확인을 위해 소화용수의 양과 목재의 수를 변화시켜 조건설정 실험을 진행한 결과 20 pieces의 목재를 적층한 후 물과 소화용수 100 mL를 살수한 경우에 한하여 소화성능의 변별력을 확인하였다. 따라서 해당 조건에서 현재 사용되고 있는 국내외 침윤소화약제를 대상으로 소화성능을 평가한 결과, 물의 경우에서만 재 발화가 발생하는 것을 확인하였다. 또한 살수 시간에 따른 온도분포를 통해 소화능력의 변별력을 판단할 수 있었다. 본 실험 결과를 바탕으로 추후 최적화 침윤소화약제 성능평가 방법을 제시하는데 기초자료로 활용할 수 있을 것으로 판단된다.

무인기관실의 효과적인 자동소화장치 개발 연구 (A Study on the Development of Fire Extinguishing System for Machinery Spaces of Small craft)

  • 강대선;이찬재;김동석;곽지현
    • 선박안전
    • /
    • 통권21호
    • /
    • pp.15-30
    • /
    • 2006
  • A study developing the dry powder fire extinguishing system inside the simulated machinery spaces of small boats was performed. Fire tests were conducted inside the compartments having volumes 2.9, 4.5, 8㎥ respectively. The openings and fans were estavlished on the walls of the compartments. Diesel oil was used for the test ruel, In addition fire extinguishing nozzles using dry powder were installed downward at ceiling and horizontally at the wall or conner. All fires in the test were extinguished under system activation and there was no reignition.

  • PDF

불활성계와 할로카본계 복합 소화약제 및 소화시스템 개발 (Inert and Halogenated compounds Fire Fighting Agent And Fire Fighting System Research)

  • 최근주;안상수;김종원;정종진
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 2009년도 춘계학술논문발표회 논문집
    • /
    • pp.165-171
    • /
    • 2009
  • A compound agent that mixes inert gas agents and halocarbon agents and a complex fire suppression system using the compound agent have been developed. The ultimate goal of this study is to develop the extinguishing agent which doesn't destroy the ozone layer and has low GWP and to develop the fire suppression system. As a result of the test and research for inert gas agents and halocarbon agents, nitrogen and FK-5-1-12 were selected finally and have been tested and studies for three years. Thus, the optimal extinguishing agent and fire suppression system have been accomplished. The performance of the agent and system was tested according to KFI performance test technical standards for gas fire extinguishing system and the fitness of the agent and system for a fire was certified by Korea Fire Industry Technology Institute (KFI).

  • PDF

A study on the corrosion evaluation and lifetime prediction of fire extinguishing pipeline in residential buildings

  • Jeong, Jin-A;Jin, Chung-Kuk;Lee, Jin Uk
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제39권8호
    • /
    • pp.828-832
    • /
    • 2015
  • This study is conducted for the evaluation of corrosion and lifetime prediction of fire extinguishing pipelines in residential buildings. The fire extinguishing pipeline is made of carbon steel. Twenty-four samples were selected among all the fire extinguishing pipelines in a building; the selection was based on specimenspositions, pipeline diameters, and pipeline thickness. Analysis was conducted by using the results of visual inspection, electrochemical potentiodynamic anodic polarization test, pitting depth measurements, and extreme value statistics with the Gumbel distribution. The maximum pitting depth and remaining life were statistically predicted using extreme value statistics. During visual inspection, pitting corrosion was observed in several samples. In addition, extreme value statistics demonstrated that there were several pipelines that were very sensitive to pitting corrosion. However, the pitting corrosion was not critical in all the pipelines; thus, it was necessary to change only those pipelines that were severely corroded.

이산화탄소 소화설비 현장 방출시험 방법론에 관한 고찰 (A Study on On-site Discharge Testing for Carbon Dioxide Fire Extinguishing Systems)

  • 박준현;강태석;김재환;김위경
    • 한국화재소방학회논문지
    • /
    • 제29권4호
    • /
    • pp.26-32
    • /
    • 2015
  • 이산화탄소 소화설비는 질식소화가 주된 소화작용이므로 제한된 시간 내에 소화약제를 방출하여 방호구역의 산소농도를 기준치 이하로 유지시키는 능력이 확보되어야 한다. 국내에서 이산화탄소 소화설비는 국민안전처 고시에 따라 인증된 설계프로그램을 사용하여 소화설비를 설계하고 있다. 그러나 소화설비가 설치된 방호구역의 기하학적 구조는 성능인증 단계의 모의실험장치와 차이가 있기 때문에 설계프로그램 적용 범위를 벗어난 소화설비 설계가 이루어질 수 있다. 특히, 저압식 이산화탄소 소화설비는 배관 내 유동현상에 따라 소화약제 방출량이 변하므로 소화설비 설치 후에 현장 방출시험을 통하여 성능을 확인할 필요가 있다. 현재까지 국내 외 기술기준에는 방출시험에 대한 방법론이 구체적으로 명시되어 있지 않다. 본 논문에서는 국내외 기술기준을 비교 분석하고, 방출시험 사례분석을 통하여 현장 방출시험 방법론을 제시하였다.

선박화재 적용 단백포 소화약제의 안정제에 따른 소화특성 (Characteristics of Protein Foam Agent by Stabilizer on the Ship Fire Extinguishment)

  • 이응우;신창섭
    • 한국안전학회지
    • /
    • 제30권4호
    • /
    • pp.79-85
    • /
    • 2015
  • Onboard fire extinguishing system is important to protect cargo and human lives and every oil tanker has foam type fire extinguishing system. Because of environmental problem, agent which contains materials such as Perfluorinated compounds are regulated and the development of the environmental friendly agent is required. The protein foam has less environmental pollution problem and has an excellent fire extinguish performance to oil fire. In the research, bivalency metal salts were added as stabilizer to increase fire resistance and stability of the foam. Ferrous sulfate, Iron chloride and Nickel chloride were used and to adjust to vessel, sea water was applied. As a stabilizer increased, the expansion ratio was raised. However 25% drainage time was decreased over 2.0 wt.% which is knowable that the foam brokes easily. The amount of generated foam was measured to check fluidity of foam and it appeared that when $FeSO_4$ 1.2 wt.% was added, the amount of generated foam reached large and also the 25% drainage time was high. To evaluate the fire extinguishing performance for oil fire, the small scale oil fire test was executed. When $FeSO_4$ 1.2 wt.% was added, fire extinguishing time was in its shortest which informs fluidity of foam and stability are important factors on fire extinguishing efficiency.

포 소화약제를 혼합한 미분무수 소화시스템의 소화성능 향상 방안에 관한 실험적 연구 (An Experimental Study on the Improvement of Fire Extinguishing Performance of Water Mist with Foam)

  • 황원준;김황진;오규형;이성은;김성원
    • 한국화재소방학회논문지
    • /
    • 제23권3호
    • /
    • pp.61-66
    • /
    • 2009
  • 본 연구에서는 미분무수 노즐을 이용하여 설치높이 변화에 따른 3종의 포 소화 약제를 각각 혼합하여 소화성능 실험을 수행하였다. 소화성능 실험 결과 순수한 물과 기존의 3%형 수성막포를 사용한 경우보다는 2%형 미분무수 전용 수성막포와 1%형 합성계면활성제포가 더욱 빠른 소화시간을 나타내었다. 또한, 순수한 물만을 사용한 경우에는 3.5m, 포 소화 약제를 사용하였을 때에는 4m의 설치높이에서 가장 좋은 소화효과 나타내었다.