• 제목/요약/키워드: External noise

검색결과 674건 처리시간 0.023초

35㎛ 점탄성수지가 적용된 1.035mm 제진강판의 이종소재간 저항점용접 특성분석 (Characteristic Analysis of Resistance Spot Welding between Dissimilar Materials of 1.035mm Laminated Vibration Damping Steel with 35㎛ Viscoelastic Resin)

  • 배기만;백종진;신창열;김승경;강명창
    • 한국기계가공학회지
    • /
    • 제20권12호
    • /
    • pp.24-29
    • /
    • 2021
  • Recently, owing to the high demand for eco-friendly cars in the automotive industry, noise and vibrations have become major challenges. The use of laminated damping steel is increasing in response to these demands. Laminated damping steel is primarily used in sound insulation plates. The vibration energy is converted into thermal energy due to the viscoelastic resin being located between two steel sheets and being able to damp the vibrations when an external force, such as, noise or vibration is applied to the steel plate. Laminated damping steel is chiefly applied to dash panels in automotive body parts, and because of its structure, junction technology for bonding with other components is necessary. However, there has not been sufficient research conducted on junctions. In this study, regardless of the electrode shape, in the range of 4.0 ~ 8.0 kA welding current, the same welding force and welding time were applied which were 2.8 kN and 200 m/s (12 cycles) and the tensile shear load and nugget size were analyzed after the resistance spot welding between different materials of laminated damping steel with a thickness of 1.035 mm. The results show that in the range of 5 ~ 8 kA welding current, 1.035 mm laminated damping steel meets the MS181-15 standard, which is the technical standard of Hyundai-Kia Motors.

두부 측 방향 방사선검사 시 선원 영상수용체간 거리와 검사 자세 변화가 선량과 영상품질에 미치는 영향 (Assessment of Dose and Image Quality according to the Change of Distance from Source to Image Receptor and the Examination Posture during the Skull Lateral Radiography)

  • 김은혜;주영철;김한용;김동환
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제45권6호
    • /
    • pp.483-489
    • /
    • 2022
  • This study proposes a new skull lateral examination, and provides an improved examination environment for patients and radiologists. The study was divided into three groups. One group was divided into the SID (source to image receptor distance) 110 ㎝ and 180 ㎝ in the skull lateral posture, the other group The other group was divided into an position in contact with the detector and an position without contact with the detector, and the other group was divided into male and female groups, considering that the difference in shoulder width between adult males and females would affect the dose and image quality. For dose evaluation, the ESD (entrance surface dose) was measured at the EAM (external auditory meatus), and the conditions were applied equally at 70 ㎸p, 200 ㎃, and 10 ㎃s. For image quality evaluation, SNR (signal to noise ratio) and CNR (contrast to noise ratio) were measured in frontal sinus, EAM, and sella turcica. As a result of ESD comparison, when sid 110 ㎝ to sid 180 ㎝ was changed among the three groups, ESD values decreased the most to 729.18±4.62 μ㏉ and 224.18±0.74 μ㏉ at 180 ㎝ (p<0.01). The values of SNR and CNR were statistically significant (p<0.01), but there was no qualitative difference. This shows that when the SID is 180 ㎝, it is possible to reduce the dose without lowering the image quality. So, It is suggested that the SID 180 ㎝ is used without contacting the detector when examining the skull lateral.

다각형 용기의 결함 검사 시스템 개발 (Development of Defect Inspection System for Polygonal Containers)

  • 윤석문;이승호
    • 전기전자학회논문지
    • /
    • 제25권3호
    • /
    • pp.485-492
    • /
    • 2021
  • 본 논문에서는 다각형 용기의 결함 검사 시스템 개발을 제안한다. 임베디드 보드는 메인부, 통신부, 입·출력부 등으로 구성된다. 메인부는 주 연산장치로써 임베디드 보드를 구동하는 운영체제가 포팅되어서 외부 통신, 센서 및 제어를 위한 입출력을 제어할 수 있다. 입·출력부는 필드에 설치되어 있는 센서들의 전기적신호를 디지털로 변환하여 메인모듈로 전달하는 역할 및 외부 스텝 모터 제어의 역활을 한다. 통신부는 영상 촬영 카메라 트리거 설정 및 제어 장치의 구동 설정의 역할을 수행한다. 입·출력부는 제어 스위치 및 센서들의 전기적신호를 디지털로 변환하여 메인모듈로 전달하는 역할을 수행한다. 동작 모드 등과 관련한 펄스 입력 등을 받기 위한 입력회로에는 외부 노이즈의 간섭을 최소화하기 위하여 각 입력포트에는 포토커플러를 설계한다. 제안된 다각형 용기의 결함 검사 시스템 개발의 정확성을 객관적으로 평가하기 위하여 다른 머신비전 검사 시스템과 비교를 해야 하지만, 현재 다각형 용기의 머신비전 검사 시스템이 존재하지 않기 때문에 불가능하다. 따라서, 동작 타이밍을 오실로스코프로 측정하여서 Test Time, One Angle Pulse Value, One Pulse Time, Camera Trigger Pulse, BLU 밝기 제어 등과 같은 파형이 정확히 출력됨을 확인하였다.

An Experimental Study of the Nozzle Lip Thickness Effect on Supersonic Jet Screech Tones

  • Aoki Toshiyuki;Kweon Yong-Hun;Miyazato Yoshiaki;Kim Heuy-Dong;Setoguchi Toshiaki
    • Journal of Mechanical Science and Technology
    • /
    • 제20권4호
    • /
    • pp.522-532
    • /
    • 2006
  • It is well known that screech tones of supersonic jet are generated by a feedback loop driven by the instability waves. Near the nozzle lip where the supersonic jet mixing layer is receptive to external excitation, acoustic disturbances impinging on this area excite the instability waves. This fact implies that the nozzle lip thickness can influence the screech tones of supersonic jet. The objective of the present study is to experimentally investigate the effect of nozzle-lip thickness on screech tones of supersonic jets issuing from a convergent-divergent nozzle. A baffle plate was installed at the nozzle exit to change the nozzle-lip thickness. Detailed acoustic measurement and flow visualization were made to specify the screech tones. The results obtained obviously show that nozzle-lip thickness significantly affects the screech tones of supersonic jet, strongly depending on whether the jet at the nozzle exit is over-expanded or under-expanded.

Force Control of Hybrid Actuator Using Learning Vector Quantization Neural Network

  • Aan Kyoung-Kwan;Chau Nguyen Huynh Thai
    • Journal of Mechanical Science and Technology
    • /
    • 제20권4호
    • /
    • pp.447-454
    • /
    • 2006
  • Hydraulic actuators are important in modern industry due to high power, fast response, and high stiffness. In recent years, hybrid actuation system, which combines electric and hydraulic technology in a compact unit, can be adapted to a wide variety of force, speed and torque requirements. Moreover, the hybrid actuation system has dealt with the energy consumption and noise problem existed in the conventional hydraulic system. Therefore, hybrid actuator has a wide range of application fields such as plastic injection-molding and metal forming technology, where force or pressure control is the most important technology. In this paper, the solution for force control of hybrid system is presented. However, some limitations still exist such as deterioration of the performance of transient response due to the variable environment stiffness. Therefore, intelligent switching control using Learning Vector Quantization Neural Network (LVQNN) is newly proposed in this paper in order to overcome these limitations. Experiments are carried out to evaluate the effectiveness of the proposed algorithm with large variation of stiffness of external environment. In addition, it is understood that the new system has energy saving effect even though it has almost the same response as that of valve controlled system.

대칭형 보에 의해 보강된 등방성 평판의 음향방사에 관한 연구 (A Study on Sound Radiation from Isofropic Plates Stiffened by Symmetrical Reinforced Beams)

  • 김택현
    • 한국생산제조학회지
    • /
    • 제7권1호
    • /
    • pp.41-50
    • /
    • 1998
  • The detemination of sound pressure radiated from peoriodic plate structures is fundamental in the estimation of noise levels in aircraft fuselages and ship hull structures. As a robust approach to this problem, here a very general and comprehensive analytical model for predicting the sound radiated by a vibrating plate stiffened by periodically spaced orthogonal symmetric beams subjected to a sinusoidally time varying point load is developed. The plate is assumed to be infinite in extent, and the beams are considered to exert both line force and moment reactions on it. Structural damping is included in both plate and beam materials. A space harmonic series representation of the spatial variables is used in conjunction with the Fourier transform to find the sound pressure in terms of harmonic coefficients. From this theoretical model. the sound pressure levels on axis in a semi-infinite fluid (water) bounded by the plate with the variation in the locations of an external time harmonic point force on the plate can be calculated efficiently using three numerical tools such as the Gauss-Jordan method, the LU decomposition method and the IMSL numerical package.

  • PDF

Influence of time-of-day on respiratory function in normal healthy subjects

  • Kwon, Yong Hyun
    • The Journal of Korean Physical Therapy
    • /
    • 제25권6호
    • /
    • pp.374-378
    • /
    • 2013
  • Purpose: Human body have biological rhythmic pattern in a day, which is affected by internal and external environmental factors. We investigated whether respiratory function was fluctuated according to the influence of time-of-day (around at 9 am, 1 pm, and 6 pm) in health subjects, using pulmonary function test (PFT). Methods: Eighteen healthy volunteers (8 men, mean ages; $22.4{\pm}1.6$, mean heights; $166.61{\pm}9.60$, mean weight; $59.3{\pm}10.3$) were recruited. Pulmonary function test (PFT) was measured at three time points in day, around 9 am, 1 pm, and 6 pm in calm research room with condition of under 55dB noise level, using a spirometer (Vmax 229, SensorMecis, USA). Forced vital capacity (FVC), forced expiratory volume at one second (FEV1), FVC/FEV1, and peak expiratory flow (PEF) were acquired. Results: In comparison of raw value of PFT among three time points, subjects showed generally better respiratory function at 9 am, than at other points, although no significance was found. In comparison of distribution of ranking for respiratory function in each individual, only PEF showed significant difference. In general, distributional ratio of subjects who showed best performance of respiratory function in a day was high. Conclusion: These findings showed that circadian rhythm by diurnal pattern was not detected on respiratory function throughout all day. But, best performance on respiratory function was observed mostly in the morning, although statistical significance did not exist.

Development of Wearable Device for Hearing Impaired people Using Arduino

  • Jeon, An-Gyoon;Jeong, Dong-won;Lee, Sang-Hyun
    • International journal of advanced smart convergence
    • /
    • 제8권4호
    • /
    • pp.214-220
    • /
    • 2019
  • Hearing impaired people are apt to be in danger because they can't detect danger with sound. Hearing impaired people have less risk-detection ability than non-disabled people because of lack of hearing. There are many devices to help the hearing impaired, such as hearing aids. A hearing aids can be helpful, but it may not be available depending on the degree or type of hearing loss for example, to the hearing-impaired people with little remaining hearing of high frequencies, ordinary hearing aids are not very useful for understanding the high frequency consonants and it requires a high cost, from thousands to tens of thousands of dollars. Also, it is difficult for the underprivileged, such as the low-income bracket and the elderly, to use them because they are difficult to manage. Therefore, this paper describes the development of low-cost wearable device to assistant a hearing-impaired people using Arduino. Also, it accepts values from switches or sensors and can control external electronic devices such as LEDs and motors to create objects that can interact with the environment. In this is paper, through sound sensors, the ambient sound was taken as an analogue value and transmitted to the aduino board, and the vibration motor was operated when the noise was generated, so that the user could be aware of the occurrence of danger.

A semispherical SQUID magnetometer system using high sensitivity double relaxation oscillation SQUIDs for magnetoencephalographic measurements

  • Lee, Yong-Ho;Hyukchan Kwon;Kim, Jin-Mok;Kim, Kwoong;Park, Yong-Ki
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제5권1호
    • /
    • pp.21-26
    • /
    • 2003
  • We designed and constructed a multichannel superconducting quantum interference device (SQUID) magnetometer system to measure magnetic fields from the human brain. We used a new type of SQUID, the double relaxation oscillation SQUID (DROS). With high flux-to-voltage transfers of the DROS, about 10 times larger than the dc SQUIDs, simple flux-locked loop circuits could be used for SQUID operation. Also the large modulation voltage of the DROS, typically being 100 $mutextrm{V}$, enabled stable flux-locked loop operation against the thermal offset voltage drift of the preamplifier. The magnetometers were fabricated using the Nb/AlOx/Nb junction technology. The SQUID system consists of 37 signal magnetometers, distributed on a semispherical surface, and 11 reference channels were installed to pickup background noises. External feedback was used to eliminate the magnetic coupling with the adjacent channels. The liquid helium dewar has a capacity of 29 L and boil-off rate of about 4 L/d with the total 48 channel insert. The magnetometer system has an average noise level of 3 fT/√Hz at 100 Hz, inside a shielded loon, and was applied to measure auditory-evoked fields.

폴리우레탄 코팅제에 있어서 Hard Segment와 Soft Segment의 조성 및 함량변화가 내마모성에 미치는 영향 (The Influence of Soft/Hard Segment Composition and Content on the Abrasion Resistance of Polyurethane Coating Agents)

  • 손형석;전동근;박성진;김용성;권귀택;김기수
    • 한국자동차공학회논문집
    • /
    • 제22권5호
    • /
    • pp.5-12
    • /
    • 2014
  • Weatherstrip coatings of urethane and silicon type which are fit to EPDM and thermoplastic materials are used in sealing systems for automotive applications for noise reduction and high slip characteristics for external applications, respectively. Polyurethane binder was successfully synthesized from poly(butyladiphate)diol (PBAD), poly(tetramethylene)glycol (PTMG) and isocyanate as starting materials. Then, polyurethane coating agents were prepared by using various additives. To investigate effects of segment types on the abrasion resistance of polyurethane coating agents, thin films based on polyurethane coating materials were fabricated. With increasing the amount of hard segment in the coating agent, abrasion resistance, modulus and tensile strength of the coating films were improved, but the elongation of the coating films was decreased.