블라인드 도입과 창면적비에 따른 표준건축물의 에너지 수요 저감에 대한 시뮬레이션 연구 (A Study on Simulation for Decreasing Energy Demand According to Window-to-Wall Ratio and Installation Blind System in Building)

  • 강석민;이태규;김정욱
    • 한국건축친환경설비학회 논문집
    • /
    • 제12권6호
    • /
    • pp.531-542
    • /
    • 2018
  • Building energy demands have highly risen in modern society; thus, It is necessary to reduce building energy demands especially commercial buildings adopting a curtain wall architecture. Curtain wall architectures have a high ratio of windows which is a vulnerable in heat insulations as cladding. In order to complement insulation performance of windows in these buildings, there are various methods adopted often such as installing blinds, wing wall and films. There are two suggestions of this paper. 1) WWR (Window-to-Wall Ratio) makes a impaction of energy demands in buildings. 2) Another one is an efficiency of blind systems which are installed in buildings in order to reduce cooling demands. It is also critical to make fundamental model for low-energy building construction by processing a lot of simulation As a result by this study, 1) an external blind system is more useful for reducing cooling energy demands rather than an internal blind system. 2) Buildings which have a large window require more amount of cooling demands. In case of WWR 45%, it needs more cooling energy rather than WWR 15% model's 3) Adopting blind system would reduce energy demands. WWR 45% model with external blind systems reduces about 4% of cooling energy demands compared to same model without any blind systems.4) it is necessary to study an efficiency of blind systems combined with renewable energy and it will be possible to reduce more energy demand in building significantly.

실증 적용을 통한 외부 전동블라인드의 성능 평가 및 개선 방안 (Evaluation and improvement of external electric blinds through field application)

  • 강민우;이희동;오양기
    • 한국음향학회지
    • /
    • 제42권3호
    • /
    • pp.181-188
    • /
    • 2023
  • 일반적인 거주 공간에서 창호는 외부소음에 직접적으로 노출된다. 외부소음을 가장 효과적으로 저감할 수 있는 방법은 내부가 아닌 외부에서 바로 소음을 차단하는 방법이다. 태양 빛 차단을 위한 외부 블라인드는 다양하게 제품화되어 있지만, 우리나라에서는 아직 적극적으로 활용되지 못하고 있다. 앞선 연구에서는 차광용으로 제작된 외부 전동블라인드의 차음성능을 검증하기 위해 공인 실험실에서 실험하였다. 그 결과 일반창호 저감 성능 대비 6 dBA의 추가 차음성능을 검증하였다. 이 연구에서는 외부 전동블라인드의 차음성능을 실제 거주 공간 창호에 실증 적용하여 저감성능을 확인하고자 하였으며, 효과적인 소음저감 성능 추가확보를 위해 개선방안을 모색하고자 하였다. 실험결과, 외부 전동블라인드 자체의 저감 성능은 기본 창호 대비 1 dBA ~ 3 dBA 수준으로 미미했다. 하지만 블라인드 슬릿 사이의 틈새 충진을 통해 2 dBA 수준의 추가 저감성능을 확인하였다.

An Analytical Study on Indoor Thermal Comfort Performance According to the Automatic Control of Internal-External Blind

  • Lee, Do-Hyung;Kim, Tae-Woo;Yoon, Jong-Ho
    • KIEAE Journal
    • /
    • 제14권3호
    • /
    • pp.31-38
    • /
    • 2014
  • The purpose of this study is to analyse PMV (Predicted Mean Vote) and PPD (Predicted Percentage of dissatisfied) by automatic control of slat-type vertical blind. EnergyPlus, a building energy analysis software has been used for this study. The energy model is calibrated in Energy Plus using measured zone temperature and glass surface temperature data for one day and thermal comfort performance inside the building analysis was carried out. The calibrated data has the MBE of 4% and Cv(RMSE) of 10%. The result was that, for better zone thermal comfort, installation of blind on the outside is more appropriate than inside or no blind case. Additionally, different glazing types were compared and it was found that Triple Low-e glass is the most favorable.

드론을 활용한 케이블지지교량 안전점검 사각지대 해소 기술 (Cable-supported Bridge Safety Inspection Blind Spot Elimination Technology using Drones)

  • 이성진;주봉철;김정호
    • 한국방재안전학회논문집
    • /
    • 제15권4호
    • /
    • pp.31-38
    • /
    • 2022
  • 케이블로 상부구조가 지지되는 특수교량의 경우 특수한 장비와 인력이 없이는 접근이 어려운 사각지대가 다수 존재하고 있어, 안전점검에 많은 애로사항이 발생하고 있는 것이 현실이다. 본 연구에서는 사장교와 현수교 등 케이블지지교량의 안전점검 사각지대를 검토하고, 드론을 활용하여 사각지대를 해소할 수 있는 방안을 연구하는 것이 목적이다. 이를 위해 해상에 위치한 사장교를 드론을 활용하여 케이블과 보강형 그리고 주탑을 점검하였다. 본 연구를 통해 드론을 활용하여 점검자의 접근이 어려운 특수교량의 외부 안전점검이 가능함을 확인하였다. 특히 특수교량의 점검사각지대인 주탑 외부 상태 및 손상 확인을 위한 드론 점검은 매우 효과적인 안전점검 방법이다.

시각장애인의 보행보조를 위한 스마트폰 케이스 구현 (Development of Walking Assist Smartphone Case for Blind People)

  • 최진우;정구민
    • 한국정보전자통신기술학회논문지
    • /
    • 제8권3호
    • /
    • pp.239-242
    • /
    • 2015
  • 시각장애인들은 외출을 하기 위해 보행 보조기기를 사용하고 있다. 또한, 최근에는 보행 보조기기뿐만 아니라 음성인식 명령기능을 탑재한 스마트폰도 이용하고 있다. 이러한 추세에 따라, 본 논문에서는 시각장애인 보행 보조를 위한 스마트 폰 케이스를 설계하고 구현하였다. 조도 센서와 스마트폰 카메라 플래시를 이용하여 어두운 장소에서 자신의 위치를 알려주는 자기 위치 알림 시스템과 초음파 센서를 이용하여 장애물을 감지하고 시각장애인들에게 음성으로 경고를 해주는 음성 경고 시스템을 제공한다. 이를 이용하면 시각장애인은 어두운 곳에서 자신의 위치를 알리고, 전방의 장애물을 피해갈 수 있어서 보다 안전하게 보행하여 사고를 방지할 수 있다.

외부 전동블라인드의 사양에 따른 창호 차음성능 개선 효과 (Improvement of sound insulation performance of windows according to the specifications of the external electric blinds)

  • 강민우;이희동;오양기
    • 한국음향학회지
    • /
    • 제41권6호
    • /
    • pp.621-628
    • /
    • 2022
  • 도로교통 소음이나 항공기 소음 등의 건물 외부소음을 저감하기 위한 가장 현실적인 방안은 각 건물의 발코니와 창호, 외벽 등 수음점에서의 차음성능을 강화하는 것이다. 그러나 아직 건물 외부의 차양장치가 광범위하게 사용되지 않고 있는 현실에 비추어 루버나 블라인드 등의 창호 외부장치를 활용하는 차음성능 개선 연구는 많지 않다. 특히 외장형 블라인드는 아침-저녁의 강한 일사의 유입을 건물 외부에서 차단하는 차광 효과 뿐 아니라 출퇴근 시간대에 발생하는 피크 소음을 차단하는 차음 효과도 동시에 목표할 수 있다. 이 연구에서는 가장 효율적인 창호 외부 차양장치의 하나인 외부 전동블라인드(External Electric Blind, EEB)를 활용하여 외부소음에 대한 차음성능을 개선하고자 하는 연구를 수행하였다. 차광 용도로 개발된 외부 전동블라인드의 구성을 변화시켜가면서 다양한 차음성능 실험을 수행하였다. 이를 통해 일반 창호의 저감 성능 대비 외부 전동블라인드를 설치함으로써 6 dB의 추가 차음성능을 얻을 수 있음을 검증하였다.

한국 직장여성의 일상 상황별 추구하는 자기이미지와 선호 패션스타일 (The Preferred Fashion Style and Self-image that Korean Career Women's Seek According to Daily Situations)

  • 홍혜림;김영인
    • 복식
    • /
    • 제66권7호
    • /
    • pp.50-68
    • /
    • 2016
  • The objectives of this study are to identify the self-image and preferred fashion styles that Korean career women seek in different daily situations, and to propose a positioning map in accords with the findings. The study conducted a survey and in-depth interviews. The study used twenty items of self-image adjectives extracted from existing studies, and eighteen fashion style stimuli collected by examining women's wear brands. The study surveyed 329 career women. Their daily situation was classified into five situations; external meeting and presentation, ordinary work, wedding and family gathering, blind date or date, and meeting with friends and acquaintances. The analysis results of this study showed that self-image and fashion style preferences are relevant to daily situation. The image most sought in external meetings and presentation was the 'Elegant' image, and the image most sought in meetings with friends and acquaintances was the 'active' image. Women on dates or blind dates sought the 'feminine' image the most, however they preferred to avoid this image during external meetings and presentations. Among fashion styles, the 'elegant/classic' style was most preferred, and the 'sexy/avant-garde' style had the lowest preference among all the styles. 'Mannish' was preferred in ordinary work and meeting with friends and acquaintances, however, it was shown as having the lowest preference level in blind dates or dates. The 'romantic/natural' style was highly preferred in meeting with friends and acquaintances, however it had a low level of preference for external meetings and presentations. This study has significance in providing practical information to utilize in fashion industry by identifying the relationship between self-image and preferred fashion style sought by career women according to daily situation, and using the results to propose a positioning map.

Seismic Behavior Investigation on Blind Bolted CFST Frames with Precast SCWPs

  • Wang, Jingfeng;Shen, Qihan;Li, Beibei
    • 국제강구조저널
    • /
    • 제18권5호
    • /
    • pp.1666-1683
    • /
    • 2018
  • To explore seismic behavior of blind bolted concrete-filled steel tube (CFST) frames infilled with precast sandwich composite wall panels (SCWPs), a series tests of blind bolted square CFST frames with precast SCWPs under lateral low-cyclic loading were conducted. The influence of the type of wall concrete, wall-to-frame connection and steel brace setting, etc. on the hysteretic curves and failure modes of the type of composite structure was investigated. The seismic behavior of the blind bolted CFST frames with precast SCWPs was evaluated in terms of lateral load-displacement relation curves, strength and stiffness degradation, crack patterns of SCWPs, energy dissipation capacity and ductility. Then, a finite element (FE) analysis modeling using ABAQUS software was developed in considering the nonlinear material properties and complex components interaction. Comparison indicated that the FE analytical results coincided well with the test results. Both the experimental and numerical results indicated that setting the external precast SCWPs could heighten the load carrying capacities and rigidities of the blind bolted CFST frames by using reasonable connectors between frame and SCWPs. These experimental studies and FE analysis would enable improvement in the practical design of the SCWPs in fabricated CFST structure buildings.

기존 학교 건물의 외피 성능 개선 방안에 관한 연구 (The Improvement of Building Envelope Performance in Existing School Building)

  • 방아영;박세현;김진희;김용재;김준태
    • KIEAE Journal
    • /
    • 제15권4호
    • /
    • pp.69-76
    • /
    • 2015
  • Purpose: This study is to investigate the effects of facade insulation and window remodeling of an existing old middle school building on the reduction of energy consumption. Method: To analyze energy performance of building, using DesignBuilder v3.4, building energy simulation tool based EnergyPlus engine. Energy consumption and problem of target building was analyzed based on data and survey. Based on building energy simulations it analyzed the variation of energy demand for the building according to U-value of wall, glazing properties and external shading devices. Result: When insulation of building was reinforced, cooling and heating load was decreased. Glazing properties that minimize cooling and heating energy consumption were analyzed. In conclusion, it is important to choose SHGC and U-value of window fit in characteristic of target building. Setting external blind for cooling load decreases 5%.

제로에너지 주택용 요소기술 조합에 따른 에너지절감에 관한 연구 (Energy Saving by Combination of Element Technologies of Zero-Energy House)

  • 신현철;장건익
    • KIEAE Journal
    • /
    • 제15권4호
    • /
    • pp.77-84
    • /
    • 2015
  • Purpose: In 2008, As the green growth policy was presented, Green Building is made any effort to propagation. In this paper, the respective technologies that are able to considerably reduce the energy demands for heating, cooling, hot-water, lighting and ventilation among the variety of technologies were selected. Method: Design factors such as (1) External insulation, (2) Triple glazing window, (3) LED lighting, (4) External venetian blind, (5) Geothermal and (6) Heat recovery ventilator were derived. In addition, energy saving effects in terms of energy demand, energy consumption and energy cost were investigated using EnergyPlus, building energy analysis tool. Result : The results were as follows. (1) It can be seen that high insulated triple glazing window, heat recovery ventilator and external insulation technology is excellent for energy demand. (2) Unlike energy demand, saving effect of energy consumption and energy cost was shown in order of Geothermal > Triple Window > Heat recovery Ventilation> Insulation> LED Lighting > EVB Blind.