• 제목/요약/키워드: External Insulation

검색결과 209건 처리시간 0.027초

COMS 특별세션 (THERMAL CONTROL DESIGN FOR COMS)

  • Jun, Hyoung-Yoll;Kim, Jung-Hoon;Kim, Sung-Hoon;Yang, Koon-Ho
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2007년도 Proceedings of ISRS 2007
    • /
    • pp.199-202
    • /
    • 2007
  • COMS (Communication, Ocean and Meteorological Satellite) is a geostationary satellite and has been developing by KARI for communication, ocean observation and meteorological observation. Conventional thermal control design, using MLI (Multi Layer Insulation), OSR (Optical Solar Reflector), heater and heat pipe, is utilized. Ka-band components are installed on South wall, while other equipment for sensors are installed on the opposite side, North wall. High dissipating communication units are located on external (surface) heat pipe and are covered by internal insulation blankets to decouple them from the rest of the satellite. External satellite walls are covered by MLI or OSR for insulation from space and for rejection internal heat to space. The ocean and meteorological sensors are installed on optical benches on the top floor to decouple thermally from the satellite. Single solar array wing is adopted in order to secure clear field of view of radiant cooler of IR meteorological sensor. This paper presents principles of thermal control design for the COMS.

  • PDF

외부 오염 환경하에서 고분자 절연재료의 표면 누설전류 측정 및 열화 패턴 분석 (Deterioration Pattern Analysis and Surface Leakage Current of Electrical Insulation in External Pollution)

  • 김영석;송길목;김선구
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.2080-2081
    • /
    • 2007
  • In this paper, the polymer insulators which had been used for electrical insulation were investigated surface leakage current and deterioration pattern. Because the electrical fault took place at the dust occurrence area due to environmental pollution. In particular, the dust accumulates easily on insulation material which is exposed an external long time. The leakage current brings out electrical fault after all. Also, it is need to variation of material and shape to repress a leakage current on electrical material. In this paper, we measured a leakage current on electrical material of facilities by dust, and in experiments the prevention to electrical fault was studied.

  • PDF

Stability analysis of an insulationless HTS pancake coil under the magnitude of external magnetic field

  • Jung, Sung-Jun;Kim, Gyeong-Hun;Kim, Kwangmin;Park, Minwon;Yu, In-Keun
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제14권4호
    • /
    • pp.41-45
    • /
    • 2012
  • An HTS (high temperature superconducting) coil without insulation has been investigated since a metallic insulation was suggested in the mid-1980s. The advantage of an insulationless HTS pancake coil is that it is more stable than an insulated HTS pancake coil. This paper focuses on the various characteristics of the insulationless HTS pancake coil related with stability, especially under the external magnetic field. Because HTS pancake coil may be influenced by the external magnetic field in a real operational environment of electrical devices. First, charge-discharge test was performed for the characteristics evaluation of the insulationless HTS pancake coil as compared with insulated HTS pancake coil in liquid nitrogen at 77 K. Based on the experiment results, characteristics evaluation of the insulationless HTS pancake coil was implemented under the external magnetic field. In order to carry out the experiment, we have fabricated a cylindrical solenoid coil to apply the magnetic field. The various characteristics of the insulationless HTS pancake coil were evaluated for charge-discharge and over-current conditions. This paper proves that the insulationless HTS pancake coil is more stable than the insulated HTS pancake under the external magnetic field.

제로에너지 주택용 요소기술 조합에 따른 에너지절감에 관한 연구 (Energy Saving by Combination of Element Technologies of Zero-Energy House)

  • 신현철;장건익
    • KIEAE Journal
    • /
    • 제15권4호
    • /
    • pp.77-84
    • /
    • 2015
  • Purpose: In 2008, As the green growth policy was presented, Green Building is made any effort to propagation. In this paper, the respective technologies that are able to considerably reduce the energy demands for heating, cooling, hot-water, lighting and ventilation among the variety of technologies were selected. Method: Design factors such as (1) External insulation, (2) Triple glazing window, (3) LED lighting, (4) External venetian blind, (5) Geothermal and (6) Heat recovery ventilator were derived. In addition, energy saving effects in terms of energy demand, energy consumption and energy cost were investigated using EnergyPlus, building energy analysis tool. Result : The results were as follows. (1) It can be seen that high insulated triple glazing window, heat recovery ventilator and external insulation technology is excellent for energy demand. (2) Unlike energy demand, saving effect of energy consumption and energy cost was shown in order of Geothermal > Triple Window > Heat recovery Ventilation> Insulation> LED Lighting > EVB Blind.

화재 지연형 바탕조정재의 기초물성 평가에 관한 연구 (Evaluation on the Properties of Fire Retardant Surface Preparation Mortars)

  • 류화성;신상헌;김득모;송성용
    • 한국건축시공학회지
    • /
    • 제18권6호
    • /
    • pp.559-567
    • /
    • 2018
  • 외단열 마감 공법에서 사용되는 바탕조정재는 화재가 발생하는 경우 얇은 마감과 폴리머의 연소로 인해 표면부가 급속하게 붕괴되어 화재에 취약한 소재이다. 본 연구에서는 열적 성능이 우수한 팽창 흑연을 사용할 경우 바탕조정재의 성능을 개선할 수 있을 것으로 기대하였다. 실험결과, 팽창흑연을 사용한 바탕조정재는 부착강도 저하 및 물흡수계수 등의 감소가 발생하는 문제점이 있으나 플라이애시와 실리카흄을 사용하여 물리적 성능이 향상되는 것으로 나타났다. 팽창흑연을 사용한 바탕조정재는 복합 단열 시험체 표면의 페놀폼은 화염에 의한 표면 뚫림이 나타나지 않아 열원의 투과를 감소시킬 수 있을 것으로 나타났다.

콘크리트내 표면매립보강된 FRP의 내화단열방법과 연단거리에 따른 온도변화 (Temperature Variation Corresponding to the Protection Method and Edge Distance in Near-Surface-Mounted FRP in Concrete with Fire Protection)

  • 임종욱;서수연
    • 대한건축학회논문집:구조계
    • /
    • 제35권11호
    • /
    • pp.137-146
    • /
    • 2019
  • Recently, the Near-Surface-Mounting method using Fiber reinforced polymer (FRP) has been developed and applied to the reinforcement of many concrete structural members. However, as a part of the fire resistance design, there is a lack of research related to fire insulation for the areas reinforced with FRP. In case of NSM reinforcement, there is a difference in the transferred temperature from the external surface to the groove corresponding to the location of the groove where the FRP is embedded, and the effect of this should be reflected in the fireproof insulation design. Therefore, in this study, after forming grooves for surface embedding in concrete blocks, fireproof insulation reinforcement was performed using Calcium Silicate (CS) fireproof board and an experiment to evaluate the temperature transfer was performed. By observing the temperature at these groove positions, the reduction of temperature transfer according to fireproof insulation detail was studied. As a result, when the NSM-FRP is properly fire-insulated using the CS-based fireproof board, the epoxy inside the groove does not reach its glass transition temperature until the external temperature reaches $800^{\circ}C$.

API-581에 의한 정량적 위험기반검사에서 탄소강 및 저합금강의 외부부식에 치한 사고발생 가능성 해석 (- Analysis of Likelihood of Failure for the External Corrosion of Carbon and Low Alloy Steels through the Quantitative Risk Based Inspection using API-581 -)

  • 이헌창;김환주;장서일;김태옥
    • 대한안전경영과학회지
    • /
    • 제6권4호
    • /
    • pp.239-248
    • /
    • 2004
  • Likelihood of failure for the external corrosion of carbon and low alloy steels, which affect to a risk of facilities, was analyzed quantitatively through the risk based inspection using API-581 BRD. We found that the technical module subfactor (TMSF) decreased as the inspection number increased and it increased as the Inspection effectiveness and the used year increased. In this condition, the TMSF showed high value for the case of the marine/cooling tower drift area as a corrosion driver, poor quality of coating, no insulation, and low insulation condition.

유기질 단열재 종류별 수중정치기간에 따른 pH 변화에 관한 연구 (SOrganic matter insulation by type of Study on pH change according to underwater settling period)

  • 홍상훈;유남규;서은석;김해나;김봉주;정의인
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2019년도 추계 학술논문 발표대회
    • /
    • pp.87-88
    • /
    • 2019
  • Research has been conducted in many fields for the zero energy of domestic buildings. Among them, the development of insulation has become an essential element. Accordingly, researches are being made to improve the performance of organic insulating materials, and PF boards having the lowest thermal conductivity among organic insulating materials have been in the spotlight. However, problems have arisen due to the problems of durability of insulation materials such as PF boards and past acidification, and the durability of insulation materials is deteriorated when moisture or water enters due to crack gaps during the insulation of the basement layer or the external insulation method. In regard to the durability of the insulation, when the organic insulators of different kinds were placed in water, the pH was weakly basic in all organic insulation materials except PF, and the PF was about 4 pH. As a result, the PF should be continuously reviewed, and further analysis should be carried out to determine what causes acidification.

  • PDF

불연성 무기 단열재를 화재확산 방지구조로 적용한 외단열 마감시스템의 화재성능 (Effect of External Thermal Insulation Composite System with a Non-combustible Calcium Silicate Based Mineral on The Mitigation for Reducing Fast Spread of Flame)

  • 이종찬;박종철;송훈
    • 한국건축시공학회지
    • /
    • 제16권5호
    • /
    • pp.397-403
    • /
    • 2016
  • 건축물의 에너지 절약기준이 강화됨에 따라 단열성능이 우수한 외단열 공법의 적용이 증가 추세에 있으나, 빈번한 화재사고로 외단열 화재확산 방지를 위한 규정이 강화되었다. 따라서, 기존 EPS 외단열 시스템의 단열성능을 확보하면서 화재안전성을 향상하기 위하여 불연성 단열재를 화재확산 방지구조로 적용한 EPS 외단열 시스템의 대형 화재시험을 ISO 13785-2에 의하여 수행하였고, 그 결과, 시간에 따른 시험체의 외형분석에서 EPS 단열재만 사용한 외단열 공법보다 우수한 화재확산 방지효과가 있는 것으로 판단되었고, 온도 및 열류량 측정결과에서도 하단부보다 상단부의 온도 및 열류량이 낮게 측정되어 차열효과가 있는 것으로 판단되었다.

공항 인근 건물(호텔)에서의 벽체구조의 차음성능에 관한 연구 (An experimental study on sound insulation of building elements of the hotel near airport)

  • 이성호;정갑철;양관섭
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 춘계학술대회논문집
    • /
    • pp.579-585
    • /
    • 2002
  • This study has measured and evaluated the sound insulation of building elements of the hotel near airport. That measurement was made in both the actual site and laboratory. The differences of sound insulation performance in between granite and double glass were measured. Moreover, the difference of sound insulation was analyzed. For the measurement, this study has tried several methodologies, and analyzed the differences respectively. The results from this analysis were applied to produce a design guides for sound insulation to prevent external noise and to make more silent indoor space which satisfied the standard rate of noise.

  • PDF