• Title/Summary/Keyword: External Device

Search Result 917, Processing Time 0.029 seconds

Inter-operation between the mobile device and external device (모바일 단말과 외부 장치 모듈과의 자동 연동 시스템)

  • Kim, Sang-Tae;Kim, Hyun-Deok;Park, Won-Kyu;Park, Yoon-Jung;Kim, Young-Cheol;Jung, Youn-Wha;Kim, Won-Gi;Park, Hong-Bae
    • Proceedings of the IEEK Conference
    • /
    • 2006.06a
    • /
    • pp.705-706
    • /
    • 2006
  • A novel plug and play system for a mobile device has been proposed and demonstrated to provide an easy inter-operation between the mobile device and external modules. It supports an automatic installation and execution of the device drivers stored in the external modules into the mobile devices when the external module is connected to the mobile device. It also enables an automatic removal of the derivers when the external module is disconnected from the mobile device, which makes the user use the resource of the mobile devices more efficiently.

  • PDF

A Study on Designing a Proper External Shading Device to Diminish the Cooling Load of a Transparent Glazing Office Building (투명 유리 사무소 건물의 냉방부하 감소를 위한 적정 외부차양 배치에 관한연구)

  • Yim, Sang-Joon;Seo, Hye-Soo;Kim, Byung-Seon
    • KIEAE Journal
    • /
    • v.2 no.4
    • /
    • pp.21-26
    • /
    • 2002
  • Modem architecture represent a great capitalistic, polishing, high-technology image to the public by design. As a result, glass architecture which show 'transmittance' in desinging play a leading part, consequently a role of machine is increasing in controlling an internal environment of building. These movement look like assisting an universal standard building disregarding a each nation's climate peculiarity, if glass building is applied by a proper external shading device. the shading device has a great effect on the reduction of cooling load energy, this research to propose the proper designing scheme of the fixed external shading device. The effect of proper external shading device on the cooling load is evaluated by the numeric simulation.

A Study of External Storage Device File Outflow (외장형 저장장치의 파일유출에 관한 연구)

  • Song, Yu-Jin;Lee, Jae-Yong
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.16 no.2
    • /
    • pp.59-64
    • /
    • 2011
  • A lot of computer users use external memory device. But, same time file efflux incidents are also increasing. There are two ways people use for efflux file. One is moving it after checking file which is running on computer and the other is checking file name only. Checking from running file case, we can identify vestige with running information of applied program but, the case of moving as external device without running file there is no evidence running applied program. So there are a lot of difficulty with forensic investigation. In this paper we suggest the way to help forensic investigation which is method of getting external memory device information of volume and time through its awareness method and connection information and moving to external device without running file after compare the external memory device volume information through link file analysis and getting information of link file formation & access time from link file.

A Study on User Authentication for Roaming in Mobile Device (모바일 디바이스의 로밍을 위한 사용자 인증에 관한 연구)

  • Kang, Seo-Il;Park, Choon-Sik;Lee, Im-Yeong
    • The KIPS Transactions:PartC
    • /
    • v.15C no.5
    • /
    • pp.343-350
    • /
    • 2008
  • In ubiquitous environment, a user has been provided with service and mobility using various devices. The users' network can be divided into a home network (a user belongs to the network through an authentication server) and an external network (when a user moves or external authentication server is). Users can use a mobile device or a device at an external network. In this paper, when a user has access to a service in an external network with a mobile device, there is a skim that a service is securely provided by roaming private information (encryption key etc${\cdots}$) and a skim which gives access to a home network using a device in an external network. If you use these skims, roaming is provided in order that you can use a secure service in an external network.

Evaluation of radiological safety according to accident scenarios for commercialization of spent resin mixture treatment device

  • Choi, Woo Nyun;Byun, Jaehoon;Kim, Hee Reyoung
    • Nuclear Engineering and Technology
    • /
    • v.54 no.7
    • /
    • pp.2606-2613
    • /
    • 2022
  • Spent resin often exceeds radiation limits for safe disposal, creating a need for commercial-scale treatment techniques to reduce resin radioactivity. In this study, the radiological safety of a commercialized spent resin treatment device with a treatment capacity of 1 ton/day was evaluated. The results confirm that the device is radiologically safe in the event of an accident. This device desorbs 14C from the spent resin, allowing disposal as low-level waste instead of intermediate-level waste. The device also reduces overall waste by recycling the extracted 14C. Potential accident scenarios were explored to enable dose assessments for both internal and external exposure while preventing further spillage of the device and processing the spilled resin. The scenarios involved the development of a surface fracture on the resin mixture separator and microwave systems, which were operated under pressure and temperature of 0-6 bar and 0-150 ℃, respectively. In the case of accidents with separator and microwave device, the maximum allowable working time of worker were derived, respectively, considering external and internal exposures. When wearing the respirator corresponding to APF 50, in the case of the microwave device accident scenario, the radiological safety was confirmed when the maximum worker worked within 132.1 h.

Two dimensional tin sulfide for photoelectric device

  • Patel, Malkeshkumar;Kim, Joondong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2016.02a
    • /
    • pp.389.1-389.1
    • /
    • 2016
  • The flexible solid state device has been widely studied as portable and wearable device applications such as display, sensor and curved circuits. A zero-bias operation without any external power consumption is a highly-demanding feature of semiconductor devices, including optical communication, environment monitoring and digital imaging applications. Moreover, the flexibility of device would give the degree of freedom of transparent electronics. Functional and transparent abrupt p/n junction device has been realized by combining of p-type NiO and n-type ZnO metal oxide semiconductors. The use of a plastic polyethylene terephthalate (PET) film substrate spontaneously allows the flexible feature of the devices. The functional design of p-NiO/n-ZnO metal oxide device provides a high rectifying ratio of 189 to ensure the quality junction quality. This all transparent metal oxide device can be operated without external power supply. The flexible p-NiO/n-ZnO device exhibit substantial photodetection performances of quick response time of $68{\mu}s$. We may suggest an efficient design scheme of flexible and functional metal oxide-based transparent electronics.

  • PDF

Device for Catheter Placement of External Ventricular Drain

  • Ann, Jae-Min;Bae, Hack-Gun;Oh, Jae-Sang;Yoon, Seok-Mann
    • Journal of Korean Neurosurgical Society
    • /
    • v.59 no.3
    • /
    • pp.322-324
    • /
    • 2016
  • To introduce a new device for catheter placement of an external ventricular drain (EVD) of cerebrospinal fluid (CSF). This device was composed of three portions, T-shaped main body, rectangular pillar having a central hole to insert a catheter and an arm pointing the tragus. The main body has a role to direct a ventricular catheter toward the right or left inner canthus and has a shallow longitudinal opening to connect the rectangular pillar. The arm pointing the tragus is controlled by back and forth movement and turn of the pillar attached to the main body. Between April 2012 and December 2014, 57 emergency EVDs were performed in 52 patients using this device in the operating room. Catheter tip located in the frontal horn in 52 (91.2%), 3rd ventricle in 2 (3.5%) and in the wall of the frontal horn of the lateral ventricle in 3 EVDs (5.2%). Small hemorrhage along to catheter tract occurred in 1 EVD. CSF was well drained through the all EVD catheters. The accuracy of the catheter position and direction using this device were 91% and 100%, respectively. This device for EVD guides to provide an accurate position of catheter tip safely and easily.

A Study on Development of Wireless Check-up Device for Captive Flight Test (탑재비행시험용 무선 점검장치 개발에 대한 연구)

  • Ryu, Sang-Gyu;Joo, Junghyun;Ko, Myoungjun
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.22 no.4
    • /
    • pp.501-508
    • /
    • 2019
  • In this paper, a study on a wireless check-up method of test equipment for captive flight test(CFT) was conducted. For CFT, test equipment is mounted on a POD, and check-up is carried on the test equipment's. For check-up the POD wirelessly, battery, power distribution unit, wireless communication devices were designed within the POD, and a check-up device is designed outside of the POD. Once the external check-up device sends a 'start signal' to the POD, it performs the overall check-up procedures and transmits the 'end signal' to the external check-up device. Detailed check-up results are stored in an internal storage device, and are possible to read from external check-up device if necessary, thereby improving the reliability of the wireless check-up. By implementing and applying these wireless check-up system, the reliability of the check-up was enhanced by dynamical and movable check-up, and safety is guaranteed as the check-up was carried without access to the aircraft.

INTERNAL VS. RIGID EXTERNAL DISTRACTION DEVICE FOR THE MAXILLARY HYPOPLASIA OF CLEFT PATIENTS (구순구개열 환자의 상악골 열성장에서 골신장술을 위한 Internal distraction device와 Rigid external distraction의 비교)

  • Paeng, Jun-Young;Myoung, Hoon;Hwang, Soon-Jung;Seo, Byoung-Moo;Choi, Jin-Young;Lee, Jong-Ho;Choung, Pill-Hoon;Baek, Seung-Hak;Kim, Myung-Jin
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.27 no.4
    • /
    • pp.324-333
    • /
    • 2005
  • Distraction osteogenesis for the advancement of hypoplastic maxilla of cleft patients has shown successful results. In this report, rigid external distraction(RED) system and internal distraction device were used for maxillary advancement. Each system has its advantages and disadvantages. Larger amount of advancement can be achieved with RED system. But complex external device may give patients psychological stress. Internal device is invisible. However its distraction amount have limitation for the advancement (< 20mm) and the vector cannot be changed freely during distraction. The authors treated five cleft patients with maxillary hypoplasia(three with RED system and two with internal distractor). Their results were clinically satisfactory. We present the pros and cons of RED and internal system for maxillary distraction osteogenesis.

Analysis of Parameters Affecting on Durability of CID Filter using Numerical Method (수치적 접근을 통한 CID필터 형상이 내력에 미치는 영향 분석 연구)

  • Bui, V.H.;Kim, S.M.;Ku, T.W.;Kim, J.;Kang, B.S.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2008.05a
    • /
    • pp.391-394
    • /
    • 2008
  • Durability of product is an important technical parameter of a current interception device (CID) filter. This parameter is influenced by several factors, such as: environment condition, external force, shape of device, heat and so on. In this study, the effect of the geometry of the device on durability was carried out. The effect of shape on durability of device is presented by force-carrying capacity that a device can sustain a maximum external force. Studied parameters of the CID filter's geometry include clearance, thickness, and corner radius. Fracture criterion of Cockcroft and Latham was also used to predict the maximum force-carrying capacity of device.

  • PDF