• Title/Summary/Keyword: Exterior Parts

Search Result 119, Processing Time 0.032 seconds

A Study on the Fire Cause Analysis of Motor Damage (전동기 소손에 대한 화재 원인 분석에 관한 연구)

  • Lee, Chun-Ha;Ok, Kyung-Jae;Kwon, Byung-Duck
    • Fire Science and Engineering
    • /
    • v.21 no.4
    • /
    • pp.59-64
    • /
    • 2007
  • We studied on the fires about the electrical motors in this paper. We compared and analyzed about the transformation and damage state of single-phase induction motors used in the home appliances when we applied electrical overload and exterior flame. This experiment was progressed by the electrical overload application test and the exterior flame application test through the locked rotor of motor. In case of the exterior flame application test, it is divided into the apply voltage case and not apply voltage case. The result of an experiment through the locked rotor of motor, it was able to observe the short-circuit marks between layers at the winding coil parts, and it was appeared a transformed dendritic tissue structure of winding coil by the electrical overload test. The application voltage and the application exterior flame, it was confirmed that the stator winding coil parts were remain original shapes and observed that the color of the winding coil's circumference was changed to red. The non-application voltage and the application exterior flame, it was observed that the stator winding coil parts were transformed quite from original shapes. It was observed that the color of the winding coil and circumference parts was changed to red at the same case of non-application voltage.

A Study on the Affordance of Façade design in Domestic Five-star Hotels (국내 5성급 호텔 입면디자인의 시지각적 지원성에 관한 연구)

  • Kim, Su-Hee;Kim, Bong-Ae
    • Korean Institute of Interior Design Journal
    • /
    • v.25 no.1
    • /
    • pp.181-191
    • /
    • 2016
  • The purpose of this study is to analyze affordance of façade design by extracting analysis elements of affordance in façade design domestic five-star hotels. The subjects of this study were 88 domestic five-star hotels; we selected literature review and case study as methodology. The analysis elements included mass forms, exterior colors, window frame patterns, exterior characteristics, and door types based on the visual perception factors of façade design from the concept of affordance. The results of the study were as follows. First, the mass forms were divided into stackable, integral, and connection types, and stackable type was most frequent. Second, exterior colors were divided into achromatic, red, yellow, and opaque color parts, and the achromatic parts were most frequent. Third, the window frame patterns were divided into grid, irregular, full, horizontal, and vertical windows, and grid windows were most frequent. Fourth, the exterior characteristics were divided into formative mass, horizontal partition, design contrast, tiled roof, and facility connection, and the formative mass was most frequent. Fifth, the door types were divided into porch, piloti, and wall type, and porch was most frequent. The results of this study showed that the façade design elements such as mass forms, exterior colors, window frame patterns, exterior characteristics, and door types intentionally contained affordance.

Exterior Vision Inspection Method of Injection Molding Automotive Parts (사출성형 자동차부품의 외관 비전검사 방법)

  • Kim, HoYeon;Cho, Jae-Soo
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.23 no.2
    • /
    • pp.127-132
    • /
    • 2019
  • In this paper, we propose a visual inspection method of automotive parts for injection molding to improve the appearance quality and productivity of automotive parts. Exterior inspection of existing injection molding automobile parts was generally done by manual sampling inspection by human. First, we applied the edge-tolerance vision inspection algorithm ([1] - [4]) for vision inspection of electronic components (TFT-LCD and PCB) And we propose a new visual inspection method to overcome the problem. In the proposed visual inspection, the inspection images of the parts to be inspected are aligned on the basis of the reference image of good quality. Then, after partial adaptive binarization, the binary block matching algorithm is used to compare the good binary image and the test binary image. We verified the effectiveness of the edge-tolerance vision check algorithm and the proposed appearance vision test method through various comparative experiments using actual developed equipment.

Numerical analysis on curtain cooling in Liquid Rocket Engine of 10tf-thrust Level using Kerosene as a Fuel (케로신을 연료로 하는 10톤급 액체로켓엔진의 막 냉각에 관한 해석적 연구)

  • 남궁혁준;한풍규;조원국
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2003.10a
    • /
    • pp.78-82
    • /
    • 2003
  • The cooling mechanism for a regenerative cooling liquid rocket engine of 10tf-thrust using kerosene as a fuel was studied from the viewpoint of curtain cooling. Based on the concept of a highly-stratified gas flow in the combustion chamber, the cross section of the combustion chamber was spilt into 2 independent parts, core and exterior part. Additional fuel is injected into the exterior section and gas temperature can be reduced in the exterior section. Consequently, the heat flux into the coolant and wall temperature are reduced and the thermal stability of a liquid rocket engine could be improved.

  • PDF

A Study on the Cooling Mechanism in Liquid Rocket Engine of 10tf-Thrust Level using Kerosene as a Fuel (케로신을 연료로 하는 10톤급 액체로켓엔진의 냉각 기구에 관한 연구)

  • Han, Pung-Gyu;Nam-Gung, Hyeok-Jun;Jo, Won-Guk
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.31 no.10
    • /
    • pp.66-72
    • /
    • 2003
  • The cooling mechanism for a liquid rocket engine of 10tf-thrust using kerosene as a fuel was studied from the viewpoint of both the regenerative and curtain cooling. Based on the concept of a highly-stratified gas flow in the combustion chamber, the cross section of the combustion chamber was spilt into 2 independent parts, core and exterior part. Additional fuel is injected into the exterior section and gas temperature can be reduced in the exterior section. Consequently, the heat flux into the coolant and wall temperature are reduced and the thermal stability of a liquid rocket en g i.ne could be improved.

MC Design and Construction for Standardization of Exterior Materials of Modular Building (모듈러건축의 외장재 모듈정합설계 및 시공)

  • Chung, Joon-Soo;Lim, Seok-Ho;Seol, Wook-Je;Baek, Cheong-Hoon
    • Journal of the Architectural Institute of Korea Planning & Design
    • /
    • v.34 no.6
    • /
    • pp.31-37
    • /
    • 2018
  • With the progress of national policy researches on the modular construction, many studies have been conducted regarding the standardization of interior building materials. However, studies on the standardization of exterior building materials are still insufficient, and there are no dedicated exterior materials for modular construction. In this regard, this study investigated the necessary of standardization through the analysis on 7 kinds of exterior materials used in general buildings and exterior building materials applied to modular apartment houses in order to establish design criteria for the standardization of dedicated modular exterior materials. Based on the analysis results, assembly reference plane in conjunction with inside dimensions was set, and panelizing standardized in five parts was proposed to solve the problem of low exterior material standardization rate. It also proposed elastic gasket and steel bracket details that can compensate for the fabrication errors of unit boxes and construction errors in stacking.

A Study on the Color of the Building Exterior for Visual Effects (시각적 효과를 위한 건물 외관 색채 연구)

  • Han, Hae-Ryon
    • Proceedings of the Korean Institute of Interior Design Conference
    • /
    • 2005.05a
    • /
    • pp.257-258
    • /
    • 2005
  • The university building which is located in Daehak-ro where the commercial buildings are. The color of the building exterior and the signs are various to distinguish. To recognize the building exterior among the surrounding areas, it needs visual and bright color on it. The blue and white selected from the color of university identity. The core of the building is treated as a tower In vertically and white color is painted. And the rest parts of the building are treated horizontally and blue color is painted. The color of the building exterior shows the visual effects not only symbolism but attention.

  • PDF

Development of Paint-free Metallic Plastic Material for Automotive Parts (자동차 부품용 무도장 메탈릭 플라스틱 소재 개발)

  • Choi, Min Jin;Cho, Jeong-Min;Choi, Young Ho;Choi, Min Ho;Lee, Choon Soo;Sung, Han Ki;Lee, Kyoung Sil;Park, Ki Hun;Hwang, Se Jong
    • Korean Chemical Engineering Research
    • /
    • v.60 no.2
    • /
    • pp.295-299
    • /
    • 2022
  • In this paper, paint-free metallic plastic material, polypropylene (PP) and acrylonitrile styrene acrylate (ASA) materials were investigated on the applications for bumper skid plate and outside mirror housing parts. In order to maximize metallic effect, type, size and content of aluminum pigment were optimized based on flop index. Hybrid aluminum pigments with different aspect ratios were used to conceal weld lines. By controlling the fluidity of the material, the flow mark problem, generated on the surface of the part, was resolved. We also investigated the surface defects of flow and weld lines by using the developed modeling and simulation.

A Study on the Planning Characteristics of Interior Space Aiming for the Exterior Space in Mixed-Use Development (복합용도개발 내부공간의 외부공간 지향성에 관한 계획특성 연구)

  • Kim, Suk-Ki;Sung, Lee-Yong
    • Korean Institute of Interior Design Journal
    • /
    • v.22 no.3
    • /
    • pp.43-51
    • /
    • 2013
  • The purpose of this study is analysing the characteristics of interior space aiming for the exterior space in mixed-used development. The range of this study is limited as passage, department store, shoppingmall and Mixed Use Development. The method of this study is as follows. First, analysing the 7 samples of the interior space aiming for the exterior space in MXD through the framework of public character categorized as 5 factors, accessibility, openness, comfort properties, connectivity, convenience in use. Second, drawing a conclusion from the precedent step. The result of this study is as follows. First, the interior space has become bigger with time. And the public character is expanded with having the same structure of the city space. Second, the interior space solves the problem of the exterior space of city but prefers the same factors with the exterior space. Third, the street in the interior space has the characteristics of openness and comfort properties through diversification. And the open space is planned in various parts of the MXD and has the character of accessibility and connectivity.