• Title/Summary/Keyword: Expressway tunnel

Search Result 86, Processing Time 0.026 seconds

Behavior of braced wall due to distance between tunnel and wall in excavation of braced wall nearby tunnel (터널에 인접한 흙막이굴착 시 터널 이격거리에 따른 거동특성)

  • Ahn, Sung Joo;Lee, Sang Duk
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.20 no.4
    • /
    • pp.657-669
    • /
    • 2018
  • In recent years, the development of complex urban areas has become saturated and much attention has been focused on the development of underground space, and deep excavation is frequently performed in order to increase the utilization of underground space due to the enlargement of buildings and the high rise of buildings. Therefore, in this study, we tried to understand the behavior of the braced wall and the behavior of the tunnel adjacent to the wall according to the stiffness of the wall and the distance between the tunnel and wall. As a result of the study, the deformation of the braced wall tended to decrease with increasing the stiffness of the wall, and the axial force acting on the struts was also different according to the stiffness of braced wall. When the stiffness of the braced wall is small (2 mm), the point at which the axial force of the braces maximizes is near 0.3H of the wall. When the stiffness of the braced wall is large (5 mm), the axial force is maximum at around 0.7H of the wall. Also, the tunnel convergence occurred more clearly when the separation distance from the braced wall was closer, the stiffness of the wall was smaller, and the tunnel convergence was concentrated to the lower right part. The ground settlement due to the excavation of the ground tended to decrease as the distance between tunnel and braced wall was closer to that of the tunnel, which is considered to be influenced by the stiffness of the tunnel.

Development of a programming logic to estimate the wall friction coefficient in vehicle tunnels with piston effects (교통환기력이 작용하는 터널 내 벽면마찰계수 추정을 위한 프로그램 로직 개발)

  • Kim, Hyo-Gyu;Choi, Pan-Gyu;Ryu, Ji-Oh;Lee, Young-Hoon
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.20 no.1
    • /
    • pp.39-53
    • /
    • 2018
  • Generally, the total ventilation resistance coefficient in a tunnel consists of inlet/outlet loss coefficient, wall friction coefficient, and other loss coefficient caused by sudden expansion and contraction of cross-section, etc. For the tunnel before opening, when the running ventilation fan is stopped, the wind speed in the tunnel is reduced by the total ventilation resistance drag. The velocity decay method is comparatively stable and easy to estimate the wall friction coefficient in the pre-opening tunnel. However, the existing study reported that when the converging wind speed is a negative value after the ventilation fan stops, it is difficult to estimate the wall friction coefficient according to the velocity decay method. On the other hand, for the operating tunnel in which the piston effect acts, a more complex process is performed; however, a reasonable wall friction coefficient can be estimated. This paper aims at suggesting a method to minimize the measurement variables of the piston effect and reviewing a method that can be applied to the operating tunnel. Also, in this study, a new method has been developed, which enables to calculate an variation of the piston effect if the piston effect is constant with a sudden change of external natural wind occurring while the wind speed in the tunnel decreases after the ventilation fan stops, and a programming logic has been also developed, which enables dynamic simulation analysis in order to estimate the wall friction coefficient in a tunnel.

Fire resistance assessment of segment lining with PP fiber amount (PP섬유 혼입량에 따른 세그먼트 라이닝의 화재저항성 평가)

  • Choi, Soon-Wook;Kang, Tae-Ho;Lee, Chulho;Kim, Hae Song;Ahn, Byoungcheol;Chang, Soo-Ho
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.23 no.5
    • /
    • pp.303-314
    • /
    • 2021
  • With the high quality/high stiffness/high strength of segment lining, segment lining is increasingly used as the final lining of the tunnel. Precast concrete lining has higher quality and strength than field concrete. Paradoxically, this contributes to greater damage to concrete in the event of a fire in a tunnel. In this study, tests were conducted to determine the fire resistance performance of segment linings according to fiber content in fire resistance methods using synthetic fibers such as PP fibers. As a result, it was confirmed that fire resistance performance required by the relevant project can be secured when using 1.5 kg/m3 of PP fiber. In addition, comparison of the results of PP fibers with PET, a similar synthetic fiber, showed better fire resistance performance than when PP fibers were used.

Reducing the wind pressure at the leading edge of a noise barrier

  • Han, Seong-Wook;Kim, Ho-Kyung;Park, Jun-Yong;Ahn, Sang Sup
    • Wind and Structures
    • /
    • v.31 no.3
    • /
    • pp.185-196
    • /
    • 2020
  • A method to reduce the wind pressure at the leading edge of a noise barrier was investigated by gradually lowering the height of a member added to the end of the noise barrier. The shape of the lowered height of the added member was defined by its length and slope, and the optimal variable was determined in wind tunnel testing via the boundary-layer wind profile. The goal of the optimal shape was to reduce the wind pressure at the leading edge of the noise barrier to the level suggested in the Eurocode and to maintain the base-bending moment of the added member at the same level as the noise-barrier section. Using parametric wind tunnel investigation, an added member with a slope of 1:2 that protruded 1.2 times the height of the noise barrier was proposed. This added member is expected to simplify, or at least minimize, the types of column members required to equidistantly support both added members and noise barriers, which should thereby improve the safety and construction convenience of noise-barrier structures.

A probabilistic assessment of ground condition prediction ahead of TBM tunnels combining each geophysical prediction method (TBM 현장에서 막장전방 예측기법 결과의 확률론적 분석을 통한 지반상태 평가)

  • Lee, Kang-Hyun;Seo, Hyung-Joon;Park, Jeongjun;Park, Jinho;Lee, In-Mo
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.18 no.3
    • /
    • pp.257-272
    • /
    • 2016
  • It is usually not an easy task to counter-measure on time and appropriately when confronting with troubles in mechanized tunnelling job-sites because of the limitation of available spaces to perform those actions with the existence of disk cutter, cutter head, chamber and other various apparatus in Tunnel Boring Machine (TBM). So, it is important to predict the ground condition ahead of a tunnel face during tunnel excavation. Efforts have been made to utilize geophysical methods such as elastic wave survey, electromagnetic wave survey, electrical resistivity survey, etc for predicting the ground condition ahead of the TBM tunnel face. Each prediction method among these geophysical methods has its own advantage and disadvantage. Therefore, it might be needed to apply several geophysical methods rather than just one to predict the ground condition ahead of the tunnel face in the complex and/or mixed grounds since those methods will compensate among others. The problem is that each prediction method will give us different answer on the predicted ground condition; how to combine different solutions into a most reasonable and representative predicted value might be important. Therefore, in this study, we proposed a methodology how to systematically combine each prediction method utilizing probabilistic analysis as well as analytic hierarchy process. The proposed methods is applied to a virtual job site to confirm the applicability of the model to predict the ground condition ahead of the tunnel face in the mechanized tunnelling.

Retraction: A numerical study on the fire smoke behavior by operating the fire prevention system in tunnel-type structure (논문 취소: 터널형 구조물의 방재시설 가동에 따른 화재연기 거동에 관한 수치 해석적 연구)

  • Lee, Ho-Hyung;Choi, Pan-Gyu;Lee, Sang-Don;Heo, Won-Ho;Jo, Jong-Bok
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.21 no.1
    • /
    • pp.189-199
    • /
    • 2019
  • In this study, behaviors of fire smoke in the operation of disaster prevention facilities (smoke damper, jet fan) in a tunnel-type structure (soundproof tunnel) were investigated numerically and results of the investigation were compared and analyzed. Through the simulation and analysis, it was found that there was a significant change in the patterns of fire smoke between the opening of the ceiling of a fire vehicle and the closing, and it was shown that the critical temperatures of PC and PMMA, main materials of a soundproof tunnel were not exceeded. In addition, the simulation of installation intervals of smoke dampers showed that the maximum temperature of a soundproof tunnel without smoke dampers was $552^{\circ}C$ while it reached $405^{\circ}C$ when smoke dampers were installed at the installation interval of 50 m. The simulation of the operation of a jet fan showed that the maximum temperature of a soundproof tunnel without a jet fan was $549^{\circ}C$ while it reached only $86^{\circ}C$ when a jet fan was operating. Therefore, it is highly expected that they could create a favorable environment for evacuation and protection of soundproofing materials, and it would be necessary to promote basic studies on tunnels serving various functions and purposes.

Recommended Practice on the Precautinary System and Installation to prevent electrical fire from reoccurring in underground tunnel (지하구조물내 전기재해 방지를 위한 설치지침 및 예방시스템 구축)

  • Kim, Se-Dong;Kim, Young-Jin;Kang, Jae-Mo
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2005.05a
    • /
    • pp.337-341
    • /
    • 2005
  • Most utiltity systems are subject to frequent changes, often due to increased loads and demand to up-grade quality of service provided. Urban renewal, expressway construction and suburban growth have also caused significant changes in urban utility distribution systems. Recently, it is required that a guideline for planning of a complete system, the reasonable design and construction methods for the efficient installation common utility tunnels must be estabilished. It prompts drastic measures to guard cities and their inhabitants against the horror of massive fires in the future. Preparedness holds the key to safety.

  • PDF

Traffic Flow Characteristics and Model on Multi-lane Roads in Urban Areas (도시내 다차선도로의 교통류특성 및 모형 연구 - 한남대교 지역을 중심으로 -)

  • 김성우;김동녕
    • Journal of Korean Society of Transportation
    • /
    • v.14 no.2
    • /
    • pp.7-29
    • /
    • 1996
  • Traffic flow characteristics is analysed on eight multi-lane roads which are unsignalized in urban areas. Data of traffic flow rates by classification and average speed were gathered every ten minutes interval for twenty-four hours. Machine (NC-90A) was used to acquire the field data. The major purpose of this study is to build up speed-density models on urban arterial roads. Five different kinds of models were tested. Those models are Greenshields' model, Greenberg's model, modified Greenberg's model, Underwood's model and Drake's model. The modified Greenberg's model fits best at six points and the Greenshield's model fits best two points out of eight points. The breakpoint(Kb) of modified Greenberg's model is between 10 and 32 pcphpl. Capacity drawn from speed-volume relationships were appeared to be arround 2,000 and 2,200 pcphpl at the Hannam Bridge and the Hannam Overpass and 1,100 and 1,700 pcphpl at Namsan Tunnel(No1) and the beginning point of Gyeong-Bu Expressway.

  • PDF

A study on the precautinary measures to prevent electrical fire from reoccurring in underground tunnel (공동구내 전기화재 미연 방지를 위한 예방시스템 구축 사례 고찰)

  • Kim, Se-Dong
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2004.05a
    • /
    • pp.429-433
    • /
    • 2004
  • Most utiltity systems are subject to frequent changes, often due to increased loads and demand to up-grade quality of service provided. Urban renewal, expressway construction and suburban growth have also caused significant changes in urban utility distribution systems. Recently, it is required that a guideline for planning of a complete system, the reasonable design and construction methods for the efficient installation common utility tunnels must be estabilished. It prompts drastic measures to guard cities and their inhabitants against the horror of massive fires in the future. Preparedness holds the key to safety.

  • PDF

Underground cavity remediation using membrane grouting method

  • Seung-Hyun Kim;Young-Hoon Jung;Jong-Ho Shin
    • Geomechanics and Engineering
    • /
    • v.38 no.5
    • /
    • pp.455-466
    • /
    • 2024
  • Ground collapse may occur around the tunnel when the cavity caused by groundwater runoff cannot resist the surcharge load. Any cavities or subsidence must be managed to avoid dangerous situations by stabilizing the ground through appropriate remedial measures. Trench and trenchless grouting methods can generally be used for the cavity restoration. The trench method is difficult to properly control the injection range and may cause environmental problems due to grout leakage and damages to the adjacent structures due to grouting pressure. In this study, Membrane-grouting method (MGM) is proposed, which, can be an appropriate trenchless grouting method that fills the void tightly and effectively controls the injection range. This method can be an alternative to eliminating the influence of adjacent structures and environmental pollution by inserting a membrane into the cavity and filling the membrane with grout. The membrane blocks the outflow of grout. In addition, it is easy to control the injection pressure to avoid heaving failure. This paper investigates the principle and application of the MGM using a theoretical method, model test and numerical analysis.