• 제목/요약/키워드: Exposure sheet

검색결과 103건 처리시간 0.025초

변형 DEEP X-ray를 이용한 마이크로 렌즈 및 V-groove 제작 (Microlens Micro V-groove Fabrication by the Modified LIGA Process)

  • 이정아;이승섭;전병희
    • 소성∙가공
    • /
    • 제13권3호
    • /
    • pp.290-295
    • /
    • 2004
  • Mircolens and microlens V-groove are realized using a novel fabrication technology based on the exposure of a resist, usually PMMA, to deep X-rays and subsequent thermal treatment and inclined deep X-ray lithography, respectively. The fabrication technology is very simple and produces microlenses and microlens V-groove with good surface roughness of several nm. The molecular weight and glass transition temperature of PMMA is reduced when it is irradiated with deep X-rays. The microlenses were produced through the effects of volume change, surface tension, and reflow during thermal treatment of irradiated PMMA. Microlenses were produced with diameters ranging from 30 to $1500\mu\textrm{m}$. The surface X-ray mask is also fabricated to realize microlens arrays on PMMA sheet with a large area. The size of the micro V-groove is fabricated in the range of 12~$60\mu\textrm{m}$.

동시(同時) 이선질(二線質)에 의한 Chest Radiography의 연구(硏究) (A Study on the Chest Radiography by Simultaneous Double Radiation Quality)

  • 임태랑;석전유치;진등굉일;전전미향
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제12권1호
    • /
    • pp.17-23
    • /
    • 1989
  • We have developed of the exposure technique for the chest radiography to get different contrast in left and right lung fields simultaneously for the effective diagnosis, I.E., get high contrast to detect tuberculosis, dispersal shadow or exudative lesions of early tuberculosis and get better sharpness and wider latitude to detect growing lesions of lung cancer or lesions overlapped with bones. As a result, by using an additional filter Cu 1.2mm with BX-III screen side and sheet of yellow cellophane on BF-III screen side at the conventional KV ($80KV{\sim}100KV$) for the chest X-ray, we can get similar densities in both left and right lung fields and, thus, this method is considered to be very effective for the quality diagnosis for the routine chest radiography.

  • PDF

변형 LIGA 공정을 통해 제작된 마이크로 렌즈 어레이의 모델링 및 성형 (Modeling and Replication of Microlens Arrays Fabricated by a Modified LIGA Process)

  • 김동성;이현섭;이봉기;양상식;이승섭;권태헌
    • 소성∙가공
    • /
    • 제15권1호
    • /
    • pp.34-41
    • /
    • 2006
  • Microlens arrays were fabricated by a modified LIGA process composed of the exposure of a PMMA (Polymethylmethacrylate) sheet to deep x-rays and subsequent thermal treatment. A successful modeling and analyses for microlens formation were presented according to the experimental procedure. A nickel mold insert was fabricated by the nickel electroforming process on the PMMA microlens arrays fabricated by the modified LIGA process. For the replication of microlens arrays having various diameters with different foci on the same substrate, both hot embossing and microinjection molding processes have been successfully utilized with the fabricated mold insert. Replicated microlenses showed very good surface roughness with the order of 1 nm. The focal lengths of the injection molded microlenses were successfully estimated theoretically and also measured experimentally.

극저주파전자계에 대한 WHO의 건강영향평가 고찰 (Exposure to extremely low frequency fields and public health)

  • 황종선;이달형;김영조;이상진;김재준
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 춘계학술대회 논문집 전기설비전문위원
    • /
    • pp.360-361
    • /
    • 2009
  • 1970년대부터 극저주파전자계가 인체건강에 유해한지에 대한 궁금증이 증가하고 있는 실정이다. 또한 그 시기로부터 중요한 이슈에 대한 해결방안과 향후 연구방향에 대한 지표설정을 위해 많은 연구가 행해져 왔다. 본 고에서는 세계보건기구(WHO)가 2007년 극저주파전자계와 인체건강의 관계 검토를 마무리한 공식보고서(Fact sheet No.322) 결과를 고찰해 보고자 한다.

  • PDF

압연강판 접착제 접합부의 환경 접합강도에 미치는 온도 및 침수시간의 영향 (Effect of Temperature and Immersion Time on the Environmental Adhesive Strength of Adhesively Bonded Joints of Rolled Steel Sheet)

  • 송준희;이희제;임재규
    • 대한기계학회논문집A
    • /
    • 제26권12호
    • /
    • pp.2662-2669
    • /
    • 2002
  • Recently structural applications of adhesive bonding method have been increased extensively in automobile industry. Adhesively-bonded joints which are used in automobile field are exposed to various environmental conditions. In this study, several environmental factors were concerned to evaluate their effects on the adhesive strength such as air temperature, water temperature, exposed time in water. The specimens are exposed for 1, 10 and 100 hours at various air temperatures to evaluate the effects of the air and water temperature on the adhesive strength. It is proved that the adhesive strength decrease with rising the air and water temperature, and the adhesive strength decrease steeply at the higher temperature with increasing the exposure time in water.

Photoresist Thermal Reflow를 이용한 Microlens Array 제작 (Fabrication of Microlens Array Using Photoresist Thermal Reflow)

  • 황성기;백상훈;권진혁;박이순
    • 한국광학회지
    • /
    • 제20권2호
    • /
    • pp.118-122
    • /
    • 2009
  • PET 필름 위에 LCD 백라이트의 프리즘 집광시트의 역할을 대체 할 수 있는 microlens array(MLA) 시트를 설계하고 제작하였다. Photoresist thermal reflow 공정으로 두께 $100{\mu}m$ PET 필름 위에 MLA를 제작하였고, 노광 시간과 reflow의 온도, 시간 등의 변수에 따른 MLA의 형상 변화를 측정하였다.

이온빔 처리를 통한 은나노와이어 전극의 전기적 특성과 안정성 향상 (Improvement of Electrical Property and Stability of Silver Nanowire Transparent Electrode Via Ion-beam Treatment)

  • 정성훈;이승훈;김도근
    • 한국표면공학회지
    • /
    • 제50권6호
    • /
    • pp.455-459
    • /
    • 2017
  • The development of flexible transparent electrode has been paid attention for flexible electronics. In this study, we have developed transparent electrode based on silver nanowires with improved electrical property and stability through ion-beam treatment. The energetic particles of ion-beam could sinter junctions of each silver nanowires and etch out polyvinylpyrollidone(PVP) coated on silver nanowires. The sheet resistance of silver nanowire transparent electrode was reduced by 74%, and the resistance uniformity was increased about 3 times after exposure of ion beam. Moreover, the stability at $85^{\circ}C$ of temperature and 85% of relative humidity could be also improved.

X-ray 식각된 PMMA의 다양한 현상조건에 따른 현상특성 (Development Characteristics of PMMA fabricated by X-ray Lithography in Various Development Conditions)

  • 김윤호;박준식;이인규;박순섭
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 하계학술대회 논문집 Vol.5 No.1
    • /
    • pp.284-287
    • /
    • 2004
  • Micro-structures fabricated by X-ray lithography are largely affected by doses, development conditions and other factors. For these reasons, PMMA development rates and its surface profiles under various development conditions were obseued. Development rates were measured in the rage from 1 to 6 $kJ/cm^3$ using the 9C1 white beamline of Pohang light source(PLS). In this experiment, we observed that development rates of stacked PMMA sheet using Si filter were relatively higher than that of not using Si filter. Furthermore, development rates in condition with the acoustic agitation(1 MHz, 3.67 $W/cm^3$) were twice than that in dipping condition with $35^{\circ}C$ developer considering the PMMA sheets-substrate bond strength

  • PDF

변형 LIGA 공정을 통해 제작된 마이크로 렌즈 어레이의 모델링 및 성형 (Modeling and Replication of Microlens Arrays Fabricated by a Modified LIGA Process)

  • 김동성;이현섭;이봉기;양상식;이승섭;권태헌
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 2005년도 금형가공,미세가공,플라스틱가공 공동 심포지엄
    • /
    • pp.23-28
    • /
    • 2005
  • Microlens arrays were fabricated using a modified LIGA process based on the exposure of a PMMA (Polymethylmethacrylate) sheet to deep x-rays and subsequent thermal treatment. A successful modeling and analyses for microlens formation were presented according to the experimental procedure. A nickel mold insert was fabricated by the nickel electroforming process on the PMMA microlens arrays fabricated by the modified LIGA process. For the replication of microlens arrays having various diameters with different foci on the same substrate, the hot embossing and the microinjection molding processes have been successfully utilized with the fabricated mold insert. Fabricated microlenses showed good surface roughness than the mold insert. The focal lengths of the injection molded microlenses were successfully measured experimentally and also estimated theoretically.

  • PDF

Performance Analysis of Low-level Radiation Shielding Sheet with Diamagnetic Nanoparticles

  • Cho, Jae-Hwan;Kim, Myung-Sam
    • Journal of Magnetics
    • /
    • 제20권2호
    • /
    • pp.103-109
    • /
    • 2015
  • In this study, the authors attempted to produce a medical radiation shielding fiber that can be produced at a nanosize scale and that is, unlike lead, harmless to the human body. The performance of the proposed medical radiation shielding fiber was then evaluated. First, diamagnetic bismuth oxide, an element which, among elements that have a high atomic number and density, is harmless to the human body, was selected as the shielding material. Next, 10-100 nm sized nanoparticles in powder form were prepared by ball milling the bismuth oxide ($Bi_2O_3$), the average particle size of which is $1-500{\mu}m$, for approximately 10 minutes. The manufactured bismuth oxide was formed into a colloidal solution, and the radiation shielding fabric was fabricated by curing after coating the solution on one side or both sides of the fabric. The thicknesses of the shielding sheets prepared with bismuth oxide were 0.1, 0.2, 0.3, 0.4, 0.5, 0.6, 0.7, 0.8, and 1.0 mm. An experimental method was used to measure the absorbed dose and irradiation dose by using the lead equivalent test method of X-ray protection goods presented by Korean Industrial Standards; the resultant shielding rate was then calculated. From the results of this study, the X-ray shielding effect of the shielding sheet with 0.1 mm thickness was about 55.37% against 50 keV X-ray, and the X-ray shielding effect in the case of 1.0 mm thickness showed shielding characteristics of about 99.36% against 50 keV X-ray. In conclusion, it is considered that nanosized-bismuth radiation shielding fiber developed in this research will contribute to reducing the effects of primary X-ray and secondary X-ray such as when using a scattering beam at a low level exposure.