• Title/Summary/Keyword: Exposure scenarios

Search Result 134, Processing Time 0.028 seconds

Consequence Analysis of Toxic Gases Generated by Fire of Lithium Ion Batteries in Electric Vehicles (전기자동차 내 리튬이온전지 화재로 발생하는 독성가스의 위험성 분석)

  • Oh, Eui-young;Min, Dong Seok;Han, Ji Yun;Jung, Seungho;Kang, Tae-sun
    • Journal of the Korean Institute of Gas
    • /
    • v.23 no.1
    • /
    • pp.54-61
    • /
    • 2019
  • As the market for portable electronic devices expands, the demand for Lithium Ion Battery (LIB) is also increasing. LIB has higher efficiency than other secondary batteries, but there is a risk of explosion / fire due to thermal runaway reaction. Especially, Electric Vehicles (EV) equipped with a large capacity LIB cell also has a danger due to a large amount of toxic gas generated by a fire. Therefore, it is necessary to analyze the risk of toxic gas generated by EV fire to minimize accident damage. In this study, the flow of toxic gas generated by EV fire was numerically analyzed using Computational Fluid Dynamic. Scenarios were established based on literature data and EV data to confirm the effect distance according to time and exposure standard. The purpose of this study is to analyze the risk of toxic gas caused by EV fire and to help minimize the loss of life and property caused by accidents.

ACA: Automatic search strategy for radioactive source

  • Jianwen Huo;Xulin Hu;Junling Wang;Li Hu
    • Nuclear Engineering and Technology
    • /
    • v.55 no.8
    • /
    • pp.3030-3038
    • /
    • 2023
  • Nowadays, mobile robots have been used to search for uncontrolled radioactive source in indoor environments to avoid radiation exposure for technicians. However, in the indoor environments, especially in the presence of obstacles, how to make the robots with limited sensing capabilities automatically search for the radioactive source remains a major challenge. Also, the source search efficiency of robots needs to be further improved to meet practical scenarios such as limited exploration time. This paper proposes an automatic source search strategy, abbreviated as ACA: the location of source is estimated by a convolutional neural network (CNN), and the path is planned by the A-star algorithm. First, the search area is represented as an occupancy grid map. Then, the radiation dose distribution of the radioactive source in the occupancy grid map is obtained by Monte Carlo (MC) method simulation, and multiple sets of radiation data are collected through the eight neighborhood self-avoiding random walk (ENSAW) algorithm as the radiation data set. Further, the radiation data set is fed into the designed CNN architecture to train the network model in advance. When the searcher enters the search area where the radioactive source exists, the location of source is estimated by the network model and the search path is planned by the A-star algorithm, and this process is iterated continuously until the searcher reaches the location of radioactive source. The experimental results show that the average number of radiometric measurements and the average number of moving steps of the ACA algorithm are only 2.1% and 33.2% of those of the gradient search (GS) algorithm in the indoor environment without obstacles. In the indoor environment shielded by concrete walls, the GS algorithm fails to search for the source, while the ACA algorithm successfully searches for the source with fewer moving steps and sparse radiometric data.

Management Strategy of Indoor Hazardous Chemicals (실내.외 통합 모델링 및 인체 위해성 평가를 통한 실내 유해화학물질의 관리 전략)

  • Shin, Yong-Seung;Lim, Hye-Sook
    • Journal of Environmental Policy
    • /
    • v.7 no.2
    • /
    • pp.67-90
    • /
    • 2008
  • The purpose of this study is to develop indoor air quality management strategies regarding indoor air pollutants while considering various factors affecting indoor pollutants concentration. The Integrated Indoor Air Quality model(IIAQ) developed by Seoul National University is used for this study. The IIAQ model is a tool that can provide an integrated view to indoor environmental pollution by simulating suggested scenarios. The results of the modeling are used to assess health risk. The concentrations that are used for the risk characterization are weighted concentrations based on the period of time in each place and existing Indoor Air Quality(IAQ) standards. The estimated concentration of toluene and formaldehyde for 10 years through the IIAQ model was 207.3 $ug/m^3$ and 36.4 $ug/m^3$ in indoors, and 55.9 $ug/m^3$ and 8.62 $ug/m^3$ in outdoors. These concentrations are lower than the existing IAQ standards. The estimated carcinogenic risk of formaldehyde is up to 1.05E-03 for the adult male group and exceeds 1E-06 for all receptor groups. This value means that cancer could affect one person out of 1000. The estimated non-carcinogenic risk of toluene was lower than 1, which means that there was no serious non- carcinogenic risk. The result of modeling shows that using low emitting indoor sources is the most effective strategy for both formaldehyde and toluene. This risk assessment suggests that the total exposure levels of existing IAQ standards may cause serious carcinogenic risk. In order to avoid uncontrolled risk, it is suggested that the current IAQ standards should be adjusted by taking into account the total amount of exposure from all exposure pathways from indoor and outdoor sources.

  • PDF

Analysis of PM2.5 Impact and Human Exposure from Worst-Case of Mt. Baekdu Volcanic Eruption (백두산 분화 Worst-case로 인한 우리나라 초미세먼지(PM2.5) 영향분석 및 노출평가)

  • Park, Jae Eun;Kim, Hyerim;Sunwoo, Young
    • Korean Journal of Remote Sensing
    • /
    • v.36 no.5_4
    • /
    • pp.1267-1276
    • /
    • 2020
  • To quantitatively predict the impacts of large-scale volcanic eruptions of Mt. Baekdu on air quality and damage around the Korean Peninsula, a three-dimensional chemistry-transport modeling system (Weather Research & Forecasting - Sparse Matrix Operation Kernel Emission - Comunity Multi-scale Air Quality) was adopted. A worst-case meteorology scenario was selected to estimate the direct impact on Korea. This study applied the typical worst-case scenarios that are likely to cause significant damage to Korea among worst-case volcanic eruptions of Mt. Baekdu in the past decade (2005~2014) and assumed a massive VEI 4 volcanic eruption on May 16, 2012, to analyze the concentration of PM2.5 caused by the volcanic eruption. The effects of air quality in each region-cities, counties, boroughs-were estimated, and vulnerable areas were derived by conducting an exposure assessment reflecting vulnerable groups. Moreover, the effects of cities, counties, and boroughs were analyzed with a high-resolution scale (9 km × 9 km) to derive vulnerable areas within the regions. As a result of analyzing the typical worst-case volcanic eruptions of Mt. Baekdu, a discrepancy was shown in areas between high PM2.5 concentration, high population density, and where vulnerable groups are concentrated. From the result, PM2.5 peak concentration was about 24,547 ㎍/㎥, which is estimated to be a more serious situation than the eruption of Mt. St. Helensin 1980, which is known for 540 million tons of volcanic ash. Paju, Gimpo, Goyang, Ganghwa, Sancheong, Hadong showed to have a high PM2.5 concentration. Paju appeared to be the most vulnerable area from the exposure assessment. While areas estimated with a high concentration of air pollutants are important, it is also necessary to develop plans and measures considering densely populated areas or areas with high concentrations of susceptible population or vulnerable groups. Also, establishing measures for each vulnerable area by selecting high concentration areas within cities, counties, and boroughs rather than establishing uniform measures for all regions is needed. This study will provide the foundation for developing the standards for disaster declaration and preemptive response systems for volcanic eruptions.

Study on the Consequence Effect Analysis & Process Hazard Review at Gas Release from Hydrogen Fluoride Storage Tank (최근 불산 저장탱크에서의 가스 누출시 공정위험 및 결과영향 분석)

  • Ko, JaeSun
    • Journal of the Society of Disaster Information
    • /
    • v.9 no.4
    • /
    • pp.449-461
    • /
    • 2013
  • As the hydrofluoric acid leak in Gumi-si, Gyeongsangbuk-do or hydrochloric acid leak in Ulsan, Gyeongsangnam-do demonstrated, chemical related accidents are mostly caused by large amounts of volatile toxic substances leaking due to the damages of storage tank or pipe lines of transporter. Safety assessment is the most important concern because such toxic material accidents cause human and material damages to the environment and atmosphere of the surrounding area. Therefore, in this study, a hydrofluoric acid leaked from a storage tank was selected as the study example to simulate the leaked substance diffusing into the atmosphere and result analysis was performed through the numerical Analysis and diffusion simulation of ALOHA(Areal Location of Hazardous Atmospheres). the results of a qualitative evaluation of HAZOP (Hazard Operability)was looked at to find that the flange leak, operation delay due to leakage of the valve and the hose, and toxic gas leak were danger factors. Possibility of fire from temperature, pressure and corrosion, nitrogen supply overpressure and toxic leak from internal corrosion of tank or pipe joints were also found to be high. ALOHA resulting effects were a little different depending on the input data of Dense Gas Model, however, the wind direction and speed, rather than atmospheric stability, played bigger role. Higher wind speed affected the diffusion of contaminant. In term of the diffusion concentration, both liquid and gas leaks resulted in almost the same $LC_{50}$ and ALOHA AEGL-3(Acute Exposure Guidline Level) values. Each scenarios showed almost identical results in ALOHA model. Therefore, a buffer distance of toxic gas can be determined by comparing the numerical analysis and the diffusion concentration to the IDLH(Immediately Dangerous to Life and Health). Such study will help perform the risk assessment of toxic leak more efficiently and be utilized in establishing community emergency response system properly.

Risk Assessment of Volatile Organic Compounds (VOCs) and Formaldehyde in Korean Public Facilities: Derivation of Health Protection Criteria Levels

  • Kim, Ho-Hyun;Lim, Young-Wook;Shin, Dong-Chun;Sohn, Jong-Ryeul;Yang, Ji-Yeon
    • Asian Journal of Atmospheric Environment
    • /
    • v.5 no.2
    • /
    • pp.121-133
    • /
    • 2011
  • This study suggests criteria to conduct a risk assessment of VOCs and formaldehyde in uncontrolled public facilities. Pollutants and facilities were selected based on two years of monitoring data and exposure scenarios in 573 uncontrolled public facilities, composed of 10 types of public institutions. With the exception of social welfare facilities, lifetime ECRs of formaldehyde and benzene in each facility were higher in employees than in users, except in social welfare facilities. In social welfare facilities, the risk of benzene for users ($1{\times}10^{-5}$) was higher than that of workers ($1{\times}10^{-6}$) because facility users live in the facility 24 hours per day, compared to workers who spend an average of 8 hours per day in the facility. The risk of benzene to workers in restaurants, academies, performance halls, internet cafe and pubs were estimated as high as $1{\times}10^{-4}$ and the risk to workers in the theaters and karaoke bars were recorded as $1{\times}10^{-5}$. Because lifetime ECRs of carcinogens exceeded $1{\times}10^{-4}$ for workers and users in most facilities, risk management of formaldehyde and benzene in these facilities is necessary. Although HQs of toluene and xylenes did not exceed 1.0, their HQs did exceed 0.1 in some facilities, so they were evaluated as potentially harmful materials. Additionally, criteria for health protection in IAQ by facility are suggested at $60-100\;{\mu}g/m^3$ for formaldehyde, $400-500\;{\mu}g/m^3$ for TVOCs, $10-20\;{\mu}g/m^3$ for benzene, $150-170\;{\mu}g/m^3$ for toluene and $100\;{\mu}g/m^3$ for xylenes, based on the survey on IAQ and HRA methodology. The excess rates of IAQ to health protection criteria in all facilities were 16% for formaldehyde, 8% for TVOCs and benzene, 9% for toulene, and 5% for xylenes.

Development of index for flood risk assessment on national scale and future outlook (전국 단위 홍수위험도 평가를 위한 지수 개발과 미래 전망)

  • Kim, Daeho;Kim, Young-Oh;Jee, Hee Won;Kang, Tae-Ho
    • Journal of Korea Water Resources Association
    • /
    • v.53 no.5
    • /
    • pp.323-336
    • /
    • 2020
  • Owing to climate change, the annual precipitation in Korea has increased since the 20th century, and it is projected to continue increasing in the future. This trend of increasing precipitation will raise the possibility of floods; hence, it is necessary to establish national adaptation plans for floods, based on a reasonable flood risk assessment. Therefore, this study focuses on developing a framework that can assess the flood risk across the country, as well as computing the flood risk index (FRI). The framework, which is based on IPCC AR5, is established as a combination of three indicators: hazard, exposure, and capacity. A data-based approach was used, and the weights of each component were assigned to improve the validity of the FRI. A Spearman correlation analysis between the FRI and flood damage verified that the index was capable of assessing potential flood damage. When predicting scenarios for future assessment using the HadGEM3-RA based on RCP 4.5 and 8.5, the flood risk tends to be lower in the early and mid-21st century, and it becomes higher at the end of the 21st century as compared with the present.

Human Effect for Commercial Wireless Power Transfer System Operating at Low Frequency (상용 자기유도방식 무선전력전송 시스템의 인체영향 분석)

  • Kang, Jun-Seok;Lee, Seungwoo;Hong, Ic-Pyo;Cho, In-Kui;Kim, Nam
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.28 no.5
    • /
    • pp.382-390
    • /
    • 2017
  • In this paper, we consider particular exposure scenarios to evaluate human effects for inductive commercial wireless charging device operating at low frequency. The coil used in this study is the A10 model in Qi standard proposed by WPC(Wireless Power Consortium), and input power is 5 W to the operating frequency of 155 kHz. In perfectly aligned condition, the max leakage magnetic field is $257.58{\mu}T$ which is obtained at the side of the device, and it is exceeded about 7.4 times of the ICNIRP 1998 reference level. The SAR is evaluated with homogeneous phantom which has electric constants of wet skin. The max value of the SAR is $134.47{\mu}W/kg$ which is obtained at the side of the device also, and it is much lower than the international guidelines. Especially, it showed higher SAR values in case of misalignment condition, so we will need to consider the misalignment condition importantly when we evaluate human effects for wireless power transfer system.

Application of Multi-Attribute Utility Analysis for the Decision Support of Countermeasures in Early Phase of a Nuclear Emergency (원자력 사고시 초기 비상대응 결정지원을 위한 다속성 효용 분석법의 적용)

  • Hwang, Won-Tae;Kim, Eun-Han;Suh, Kyung-Suk;Jeong, Hyo-Joon;Han, Moon-Hee;Lee, Chang-Woo
    • Journal of Radiation Protection and Research
    • /
    • v.29 no.1
    • /
    • pp.65-71
    • /
    • 2004
  • A multi-attribute utility analysis was investigated as a tool for the decision support of countermeasures in early phase of a nuclear accident. The utility function of attributes was assumed to be the second order polynomial expressions, and the weighting constant of attributes was determined using a swing weighting method. Because the main objective of this study focuses on the applicability of a multi-attribute utility analysis as a tool for the decision support of countermeasures in early phase of a nuclear accident, less quantifiable attributes were not included due to lack of information. In postulated accidental scenarios for the application of the designed methodology, the variation of the numerical values of total utility for the considered actions, e.g. sheltering, evacuation and no action, was investigated according to the variation of attributes. As a result, it was shown that the numerical values of total utility for the actions are distinctly different depending on the exposure dose and monetary value of dose. As increasing in both attributes, the rank of the numerical values of total utility increased for evacuation, which is more extreme action than for sheltering, while that of no action decreased. As expected probability of high dose is higher, the break-even values for the monetary value of dose, which are the monetary value of dose when the ranking of actions is changed, were lower. In audition, as aversion psychology for dose is higher, the break-even values for dose were lower.

Comparison of Airborne Asbestos Concentrations from Soils in Naturally Occurring Asbestos(NOA) Areas - Activity Based Sampling(ABS) vs. Real-time Asbestos Fiber Monitor(F-1 fiber monitor) - (자연발생석면지역의 토양 내 석면함유율에 따른 비산석면 농도평가 - 활동근거시료채취방법(ABS)과 실시간 섬유 측정 장치(F-1 fiber monitor) 결과 비교 -)

  • Jang, Kwangmyung;Park, Kyunghoon;Choi, Sungwon;Kim, Hyunwook
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.27 no.3
    • /
    • pp.245-256
    • /
    • 2017
  • Objectives: The present study is aimed at performing real-time measurement of fibrous materials using an F-1 fiber monitor, investigating the correlations between the measurements and environmental conditions, and assessing the feasibility of the use of the monitor in actual exposure assessments based on the accuracy and reliability of the device. Methods: Asbestos specimens with a fixed asbestos content were dispersed in a chamber and collected with a particle measuring test device. Measurements obtained by the existing PCM method, and with the F-1 fiber monitor were compared. In addition, concentrations of asbestos fibers obtained by the PCM method, the TEM method, and the F-1 fiber monitor were compared with that of specific ABS scenarios in NOA regions. Correlations of asbestos contents in soil and weather conditions with each method of measurement were analyzed. Results: Laboratory results showed that levels of asbestos fibers measured with each method increased as fiber contents in soil increased. In the accuracy and reproducibility assessment, no significant differences were found between the different methods of measurement. On-site assessment results showed positive correlations among the methods, and these correlations were less significant compared with what was shown by the laboratory results. Levels of asbestos fibers increased as asbestos contents in soil increased, and as temperature increased. Levels of asbestos fibers decreased as humidity increased, and wind speed did not significantly affect the extent to which asbestos fibers were scattered. Conclusions: While it would be premature to replace existing methods with the use of F-1 fiber monitors in real sites based on the results of this study, the monitor may be useful in the screening of the sites, which assesses hazard levels in different regions. Replacement of existing methods with the use of F-1 fiber monitors may be possible after the limitations identified in this study are overcome, and additional assessment data are obtained and reviewed under different conditions to confirm the reliability of the monitor in future research. Obtained assessment results may be used as basic data for the assessment of asbestos hazard in NOA regions.