• Title/Summary/Keyword: Exposure doses

Search Result 551, Processing Time 0.021 seconds

Risk Assessment from Heterogeneous Energy Deposition in Tissue. The Problem of Effects from Low Doses of Ionizing Radiation

  • Le, Feinendegen;J, Booz
    • The Korean Journal of Nuclear Medicine
    • /
    • v.26 no.1
    • /
    • pp.8-13
    • /
    • 1992
  • Low doses of ionizing radiation from external or internal sources cause heterogeneous distribution of energy deposition events in the exposed biological system. With the cell being the individual element of the tissue system, the fraction of cells hit, the dose received by the hit, and the biological response of the cell to the dose received eventually determine the effect in tissue. The hit cell may experience detriment, such as change in its DNA leading to a malignant transformation, or it may derive benefit in terms of an adaptive response such as a temporary improvement of DNA repair or temporary prevention of effects from intracellular radicals through enhanced radical detoxification. These responses are protective also to toxic substances that are generated during normal metabolism. Within a multicellular system, the probability of detriment must be weighed against the probability of benefit through adaptive responses with protection against various toxic agents including those produced by normal metabolism. Because irradiation can principally induce both, detriment and adaptive responses, one type of affected cells may not be simply summed up at the expense of cells with other types of effects, in assessing risk to tissue. An inventory of various types of effects in the blood forming system of mammals, even with large ranges of uncertainty, uncovers the possibility of benefit to the system from exposure to low doses of low LET radiation. This experimental approach may complement epidemiological data on individuals exposed to low doses of ionizing radiation and may lead to a more rational appraisal of risk.

  • PDF

Determination of Absorbed Dose for Gafchromic EBT3 Film Using Texture Analysis of Scanning Electron Microscopy Images: A Feasibility Study

  • So-Yeon Park
    • Progress in Medical Physics
    • /
    • v.33 no.4
    • /
    • pp.158-163
    • /
    • 2022
  • Purpose: We subjected scanning electron microscopic (SEM) images of the active layer of EBT3 film to texture analysis to determine the dose-response curve. Methods: Uncoated Gafchromic EBT3 films were prepared for direct surface SEM scanning. Absorbed doses of 0-20 Gy were delivered to the film's surface using a 6 MV TrueBeam STx photon beam. The film's surface was scanned using a SEM under 100× and 3,000× magnification. Four textural features (Homogeneity, Correlation, Contrast, and Energy) were calculated based on the gray level co-occurrence matrix (GLCM) using the SEM images corresponding to each dose. We used R-square to evaluate the linear relationship between delivered doses and textural features of the film's surface. Results: Correlation resulted in higher linearity and dose-response curve sensitivity than Homogeneity, Contrast, or Energy. The R-square value was 0.964 for correlation using 3,000× magnified SEM images with 9-pixel offsets. Dose verification was used to determine the difference between the prescribed and measured doses for 0, 5, 10, 15, and 20 Gy as 0.09, 1.96, -2.29, 0.17, and 0.08 Gy, respectively. Conclusions: Texture analysis can be used to accurately convert microscopic structural changes to the EBT3 film's surface into absorbed doses. Our proposed method is feasible and may improve the accuracy of film dosimetry used to protect patients from excess radiation exposure.

Recent Trend of Occupational Exposure to Ionizing Radiation in Korea, 2015-2019

  • Lim, Young Khi
    • Journal of Radiation Protection and Research
    • /
    • v.46 no.4
    • /
    • pp.213-217
    • /
    • 2021
  • Background: Radiation exposure can occur as a result of occupational activities utilizing sources of radiation. The average level of occupational exposure is generally similar to the global average, but some workers receive more than this. In this study, the occupational exposure data for workers in Korea to check the recent trend of radiation exposure. Materials and Methods: The data collection and analysis are carried out by two separate periods based on the United Nations Scientific Committee on the Effects of Atomic Radiation (UNSCEAR) survey. One is the year 2003 to 2014 for a recent survey, and the other is 2015 to 2019. All available data were collected by annual reports from radiation dose registry organizations. Results and Discussion: The annual dose over the record level to the total workers did not change much compared with the total increasing number of workers in this period. The dose to the nuclear fuel cycle field has a tendency to decrease. It resulted from the efforts of radiation dose reduction with high technology introduced to this area. Also, it is important result that the radiation dose to the workers in radiography is remarkably reduced. Conclusion: The number of radiation workers and average doses were analyzed for occupational categories in Korea. It still needs cooperative efforts between the dose registry organizations for the efficient dose management of Korean radiation workers.

A Study on the Neutron Dose Distribution in Case of 10 MV X-rays Radiotherapy (10MV X선 방사선 치료 시 중성자 선량 분포에 관한 연구)

  • Park, Cheol-Soo;Lim, Cheong-Hwan;Jung, Hong-Ryang;Shin, Seong-Soo
    • Journal of radiological science and technology
    • /
    • v.31 no.4
    • /
    • pp.415-417
    • /
    • 2008
  • This study is to measure the radiation dose of neutrons generated by the particle accelerator during X-ray (photon) treatment with a neutron detection method by using CR-39, and to research how the generation of neutrons may incur problems associated with radiation doses for patient treatment when using high energy photons for cancer treatment as a clinical application. The findings are summarized as follows : The results showed that average 0.35mSv was measured with exposure of 1Gy photon in case of fast neutron, 0.65mSv with exposure of 2Gy photon, 1.82mSv exposure of 5Gy, 0.26mSv with exposure of 1Gy photon in case of thermal neutron, 0.56mSv with exposure of 2Gy photon, and 1.23mSv with exposure of 5Gy of photon. By measuring the occurrence of neutron by using Wedge Filter, it has been confirmed that the occurrence of neutrons increased when using Wedge Filter. The results also showed that more neutrons were detected over the existing experiments when using an SRS Cone requiring high doses of radiation. Total 2.85mSv neutrons were found on the average with exposure of 5Gy photon in case of fast neutron and 1.37mSv neutrons were found on the average with exposure of 5Gy photon in case of thermal neutron. During the general treatment, about 1.6 times more neutrons over 5Gy photon were found in case of fast neutron and about 1.12 time more neutrons over 5Gy photon were found in case of thermal neutron.

  • PDF

A Study on Radiation Exposure Dose of Operator During Interventional Radiology Procedure (방사선 중재적 시술 중 시술자의 피폭선량에 대한 연구)

  • Jeon, Mi-Eun;Lim, Cheong-Hwan;Jung, Hong-Ryang;You, In-Gyu;Hong, Dong-Hee;Kang, Byung-Sam
    • Journal of radiological science and technology
    • /
    • v.35 no.3
    • /
    • pp.219-226
    • /
    • 2012
  • Interventional radiologists are not aware of the potential injury from procedures. The purpose of this study are to evaluate radiation exposure of interventional radiologist from intervention procedures and to develop guideline of the simple methods for decreasing their radiation exposure from intervention procedure. In this study, Dosimeters were used to monitor operator doses of radiation exposure in a broad range of procedures from 20 interventional radiologist during the periods of 3 months. And, we searched protection methods of each interventional radiologist. During TACE procedure, there was using 0.5 mmPb radiation protector decreased average 89.5 % of radiation exposure. Thicker radiation protector provide decreasing radiation exposure. And radiation exposure dose decreased average 47.7 % by using pulse fluoroscopic mode. Therefore, interventional radiologist should wear protective aprons, use active shielding, monitor their doses, and know how to poisoning themselves during the procedure and operate correct of the machines for minimum dose.

Occupational Exposure of Semiconductor Workers to ELF Magnetic Fields (반도체 제조 근로자의 극저주파 자기장 노출 평가)

  • Chung, Eun Kyo;Kim, Kab Bae;Chung, Kwang Jae;Lee, In Seop;You, Ki Ho;Park, Jung-Sun
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.22 no.1
    • /
    • pp.42-51
    • /
    • 2012
  • Objectives: To compare the exposure level of extremely low frequency (ELF) magnetic fields among semiconductor workers, shipyard welders and office workers. Methods: To measure the ELF magnetic field concentration, EMDEX LITE (Enertech, USA) were used and monitored for eight hours continuously. Five companies handling the electric and magnetic field (EMF) source were investigated, which the exposure groups were classified into three groups: semiconductor workers, welders, and office workers. Welder group was chosen as a high exposed group and office group as a low exposed group. Results: The arithmetic mean (${\pm}SD$) and geometric mean (GSD) of personal exposure level of semiconductor workers were 0.73 (${\pm}1.33$) ${\mu}T$, 0.43 (2.88) ${\mu}T$, respectively. The ceiling value ranged between 0.18 and 123.2 ${\mu}T$. Welders were exposed high with the arithmetic mean value of 3.46 (${\pm}\;13.46$) ${\mu}T$ and geometric mean value of 0.45 (4.70) ${\mu}T$, respectively, and ceiling value range of 75.5~129.6 ${\mu}T$. The exposure levels of office workers were low compared to other exposed groups; the arithmetic mean 0.05 (${\pm}0.13$) ${\mu}T$, geometric mean 0.03 (2.38) ${\mu}T$ and ceiling value range 0.37~3.35 ${\mu}T$. This study revealed statistically significant differences of the mean ELF magnetic field exposure doses among three groups (p < 0.01). Conclusions: The average ELF magnetic field exposure doses of semiconductor workers were much higher than those of office workers in control group, but were lower than those of welders in high exposure group.

Relationship between the Changes of Catecholamines and Blood Pressure Induced by Exposure to Low- and High-levels of Lead in Rats

  • Yoon, Suh-Young;Yoo, Kyeong-Seok;Cheong, Jae-Hoon
    • Biomolecules & Therapeutics
    • /
    • v.7 no.4
    • /
    • pp.322-328
    • /
    • 1999
  • In this study, it was tested whether the changes of catecholamines and its metabolites are related with the changes of blood pressure(BP) induced by different levels of lead exposure. Adult male SD rats were exposed to lead by giving drinking water containing 50(low doses), 200 and 1,000 ppm(high doses) of lead(as lead acetate) or sodium acetate(for control groups, supplying an identical amount of acetate) for 7 or 16 weeks. The systolic BP was measured in the unanesthetized state by the tail-cuff technique. Levels of catecholamines and its metabolites in urine were measured by HPLC-ECD. Rats receiving 200 and 1,000 ppm developed an elevation of systolic BP at 3 and 7 weeks compared with week 0, but blood pressure levels at 16 weeks returned to normal. For the 50 ppm lead treated group, systolic BP increased significantly at 7 weeks and 16 weeks. The concentrations of norepinephrine and VMA in the urine of lead exposed rats changed similarly to the changes of blood pressure, but blood viscosity levels in all lead treated rats increased continuously during all lead treatment periods. This result suggests that the changes of catecholamines and its metabolites in urine by lead intoxication may influence the changes of blood pressure.

  • PDF

Accumulation of Butyltin Compounds in Shellfish and Fish from Korean Coastal Areas

  • Choi, Hee-Gu;Kim, Sang-Soo;Moon, Hyo-Bang;Lee, Pil-Yong;Gu, Bon-Kyu
    • Journal of the korean society of oceanography
    • /
    • v.37 no.2
    • /
    • pp.82-89
    • /
    • 2002
  • Butyltins (BTs) were measured in 2 species of shellfish and 16 species of fish collected along the Korean coast. Tributyltin (TBT) was detected in the mussels and oysters of sentinel organisms (20 to 940 ng Sn/g dry wt), indicating widespread contamination of TBT in the Korean coast. The elevated concentrations of TBT in the shellfish found in the sites near harbors or shipyards suggested that antifouling paints are probable major sources of butyltins in these areas. The TBT compound was detected in 12 out of 16 fish samples. The concentrations of TBT in fish muscles wee between 7 and 151 ng Sn/g dry wt, while the level in whole body of anchovy was very high (793 ng Sn/g dry wt). Exposure doses to Korean people via consumption of these marine products wee evaluated. The results suggested that the environmental levels of TBT were below the level of concern.

Measurements and Assessments on Shielding Performance of FCTC10 60Co Transport Container

  • Zhuang, Dajie;Zhang, Guoqing;Li, Guoqiang;Wang, Renze
    • Journal of Radiation Protection and Research
    • /
    • v.41 no.3
    • /
    • pp.310-314
    • /
    • 2016
  • Background: FCTC10 container is designed to transport $^{60}Co$ radioactive sources used in irradiation industry. It belongs to Type B(U) Category III (yellow) package when being loaded with a $^{60}Co$ source of $1.8{\times}10^5$ Ci. Materials and Methods: The container is constituted of shielding container, basket, protective cover and bracket. Shielding ability is provided mainly by stainless steel shells, tungsten alloy and lead among steel shells. Radiation level around the container has been calculated with both Monte Carlo simulations and measurements. Results and Discussion: It is proven that the shielding performance of the container fulfills the requirements in GB11806-2004 (Regulations for the safe transport of radioactive material, China Standard Press). Exposure doses to workers and to critical groups of public were calculated based on hypothetical exposure scene according to transport practice experience. Conclusion: The results show that doses to workers and public are less than the constraint dose considered in design, and the radiation level would be increased less than a factor of 2 under design basis accidents.

The Experimental Study on Biochemical Changes of Rat Liver Following Single Irradiation of High Energy X-ray (고(高)에너지 방사선(放射線)을 1회조사(一回照射)한 흰쥐 간(肝)의 생화학적(生化學的) 변화(變化))

  • Lee, Joon-Il;Park, Myeong-Hwan;Park, Chong-Sam
    • Journal of radiological science and technology
    • /
    • v.16 no.2
    • /
    • pp.87-94
    • /
    • 1993
  • In order to investigate radiation effects on the liver, functional changes of liver were analyzed after irradiation. Doses of 10 Gy, 15 Gy and 20 Gy were exposed partially to the liver of male rats(Sprague-Dawley) with X-ray(4MV linear accelerator) at room temperature. On 1, 2, 4 and 8 weeks after irradiation, liver tissues and sera of the animals were compared with those of unirradiated animal by liver function tests. Enzyme activities in sera such as alanine aminotransferase, aspartate aminotransferase, malondialdehyde. The content of malondialdehyde in the activities of many enzymes including alanine aminotransferase, aspartate aminotransferase in sera were increased slightly with increasing exposure dose in all experiments and the activities of these enzymes increased markedly in 20 Gy irradiated groups. From these above results, functional changes of the liver were induced in all irradiated groups. Damaged liver was recovered along with time collapse after irradiation to the doses of 10 Gy and 15 Gy while no recovery was deteced within 8 weeks after irradiation to 20 Gy. These results suggest that careful attention must be paid to liver not to be included in exposure field in radiation therapy.

  • PDF