• Title/Summary/Keyword: Exposure doses

Search Result 551, Processing Time 0.025 seconds

Enhancement of Chromosome Aberrations in Lymphocytes of Mice after in Vivo Exposure to Chemicals and in Vitro Challenge with Bleomycin (MNNG 또는 Benzo(a)pyrene 유도 염색체 이상에 미치는 Bleomycin의 효과)

  • Heo, M.Y.;Grady, J.J.;Au, W.W.
    • Environmental Mutagens and Carcinogens
    • /
    • v.18 no.2
    • /
    • pp.71-76
    • /
    • 1998
  • Exposure to environmental toxicants can cause cellular problems including the interference of DNA repair processes which may lead to the development of cancer. The existence of toxicant-induced DNA repair abnormality was investigated using mice exposed in vivo to genotoxic chemicals and then challenging their exposed lymphocytes in vitro with bleomycin. The repair of bleomycin-induced DNA damage as estimated by the frequency of chromosome aberrations was determined. Our data indicates that the observed aberration frequencies after in vivo exposure to N-methyl-N'-nitro-N-nitnsoguanidine (MNNG) and in vitro challenge with bleomycin are consistently higher than expected. The enhanced response is not due to the induction of chromosome damage by 25 or 50 mg/kg MNNG since the chemical did not cause chromosome aberrations in lymphocytes of these mice. The observed response after the combined exposure to benzo[a]pyrene (BP) and bleomycin was significantly lower than expected with low in vivo doses of BP (50 mg/kg) and then significantly higher than expected with the high doses (200 mg/kg). We interpret our data to indicate that in vivo exposure to genotoxic agents can cause abnormal DNA repair activities. The response is, however, independent of the clastogenic activities of the inducing chemicals, but dependent upon the inducing agents and on the exposure doses.

  • PDF

Analysis of Trends in Dose through Evaluation of Spatial Dose Rate and Surface Contamination in Radiation-Controlled Area and Personal Exposed Dose of Radiation Worker at the Korea Institute of Radiological and Medical Sciences (KIRAMS)

  • Lee, Bu Hyung;Kim, Sung Ho;Kwon, Soo Il;Kim, Jae Seok;Kim, Gi-sub;Park, Min Seok;Park, Seungwoo;Jung, Haijo
    • Progress in Medical Physics
    • /
    • v.27 no.3
    • /
    • pp.146-155
    • /
    • 2016
  • As the probability of exposure to radiation increases due to an increase in the use of radioisotopes and radiation generators, the importance of a radiation safety management field is being highlighted. We intend to help radiation workers with exposure management by identifying the degree of radiation exposure and contamination to determine an efficient method of radiation safety management. The personal exposure doses of the radiation workers at the Korea Institute of Radiological & Medical Sciences measured every quarter during a five-year period from Jan. 1, 2011 till Dec. 31, 2015 were analyzed using a TLD (thermoluminescence dosimeter). The spatial dose rates of radiation-controlled areas were measured using a portable radioscope, and the level of surface contamination was measured at weekly intervals using a piece of smear paper and a low background alpha/beta counter. Though the averages of the depth doses and the surface doses in 2012 increased from those in 2011 by about 14%, the averages were shown to have decreased every year after that. The exposure dose of 27 mSv in 2012 increased from that in 2011 in radiopharmaceutical laboratories and, in the case of the spatial dose rate, the rate of decrease in 2012 was shown to be similar to the annual trend of the whole institute. In the case of the surface contamination level, as the remaining radiation-controlled area with the exception of the I-131 treatment ward showed a low value less than $1.0kBq/m^2$, the annual trend of the I-131 treatment ward was shown to be similar to that of the entire institute. In conclusion, continuous attention should be paid to dose monitoring of the radiation-controlled areas where unsealed sources are handled and the workers therein.

Effects of Perinatal Exposure to Phthalate/Adipate Esters on Sex Steroid Levels and Hypothalamic Gene Expression during Early Postnatal Periods in Rats

  • Lee, Hwi-Cheul;Im, Gi-Sun;Chung, Hak-Jae;Lee, Poong-Yeon;Park, Jin-Ki;Chang, Won-Kyong;Yang, Boh-Suk;Yamanouchi, Keitaro;Nishihara, Masugi
    • Reproductive and Developmental Biology
    • /
    • v.30 no.4
    • /
    • pp.247-253
    • /
    • 2006
  • Our previous research has identified granulin (grn) and p130 genes as sex steroid-inducible genes in the rat hypothalamus, which might be involved in sexual differentiation of the brain. Phthalate esters that are used as plasticizers and also found at low levels in foods such as dairy products are often mentioned as suspected endocrine disrupters. The purpose of the present study is to elucidate whether perinatal exposure to di-n-butyl phthalate (DBP), diisononyl phthalate (DINP) and di-2-ethylhexyl adipate (DEHA) affects hypothalamic sex steroid-inducible genes. The present study assessed the effects of perinatal exposure to DBP, DINP and DEHA on sex steroid hormones levels and hypothalamic gm and p130 mRNA expressions at postnatal day (PND) 3 and 7. Pregnant rats were fed a soy-free diet containing 20, 200, 2,000 and 10,000 ppm of DBP, 40, 400, 4,000 and 20,000 ppm of DINP, or 480, 2,400 and 12,000 ppm of DEHA from gestational day (GD) 15 to GD 3 or 7. At PND 3 and 7, perinatal exposure to these chemicals did not substantially affect serum concentrations of testosterone and estradiol. At PND 3, the expression of grn mRNA levels in males was decreased by DEHA, and that of p130 was decreased by DBP, DINP and DEHA, though the effects were not dose-dependent. At PND 7, the expression of gm gene in female pups was increased by higher doses of DBP and all the doses, except for 4,000 ppm, of DINP, while that in male pups decreased by 480 and 12,000 ppm of DEHA. Hypothalamic expression of p130 mRNA in males was increased by lower doses of DBP and all the doses of DINP, whereas that of females was decreased by 480 and 2,400 ppm of DEHA. These results suggest that these chemicals may affect the expression of gm and p130 genes by directly acting on the hypothalamus, thus leading to inappropriate expression of these genes.

The Assessment and Reduction Plan of Radiation Exposure During Decommissioning of the Steam Generator in Kori Unit 1 (고리1호기 증기발생기 제염해체 시 작업자 피폭선량 평가 및 저감화 방안)

  • Son, Young Jik;Park, Sang June;Byon, Jihyang;Ahn, Seokyoung
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.16 no.3
    • /
    • pp.377-387
    • /
    • 2018
  • Korea's first commercial nuclear power plant, Kori Unit 1, was permanently shut down on June 18, 2017, after 40 years of successful operation. Kori Unit 1 plans to construct a waste treatment facility in the turbine building prior to commencement of dismantling in earnest. Various radioactive wastes are decontaminated, disassembled, cut and melted in the waste treatment facility and sent to the radioactive waste repository. The proportion of metal radioactive waste in dismantled waste is about 70%, of which large metal radioactive waste is mainly generated in the primary circuit and has high radioactivity, so radiation exposure must be managed during disassembly. In this study, the steam generators are selected as large metal radioactive waste, the exposure doses of the dismantling workers are calculated using RESRAD-RECYCLE code and the methods for reducing the exposure doses are suggested.

A Study on the Using of Automatic Exposure Control in the Chest Radiography (흉부 방사선검사에서 자동노출제어 사용에 관한 연구)

  • Choi, Sung-Sik;Lim, Cheong-Hwan;Jung, Sung-Hoon
    • Journal of radiological science and technology
    • /
    • v.42 no.1
    • /
    • pp.19-24
    • /
    • 2019
  • For general radiological examinations, even in the same area and the same test, the test conditions must be set differently according to the patient. However, since it is impossible to consider the body shape and conditions of patients every time in medical institutions where various patients visit, the tests are conducted by setting the AEC which automatically sets the test conditions. AEC is most commonly used in chest radiography. Therefore, the purpose of this study is to propose the improvement plans for using AEC by measuring the exposure dose and evaluating the image quality according to whether the AEC is used or not, and to provide basic data for AEC research. In the present study, images were acquired while varying tube voltage and test distance according to the use of AEC in chest radiography. The radiation dose was measured by placing the dosimeter in front of the chest phantom, and the CNR and SNR of acquired images were analyzed using Image J. The t-test was conducted for the statistical analysis and the significance was determined at the level of 95%(p<.05). As a result of this study, in the inspection distance (100cm, 140cm, 180cm) according to the use of AEC, high doses were observed when the AEC was used and there was statistically significant difference(p<.05). In the t-test to determine the difference between CNR and SNR depending on whether AEC was used or not, there was no significant difference according to the use of AEC(p>.05). Therefore, when performing chest radiography, if the radiologist establishes the appropriate examination conditions and conducts the examination by not just relying solely on AEC, it may be possible to reduce unnecessary radiation exposure to the patient.

Effects of Chitosan on the Lead Level and Histological Changes in Rats Exposed to Various Levels of Lead (납에 노출된 흰쥐의 혈액과 조직의 납 함량 및 병변에 대한 키토산의 섭취효과)

  • Park Joo Ran;Kim Mee hye;Lee Yeon Sook
    • Journal of Nutrition and Health
    • /
    • v.38 no.1
    • /
    • pp.48-55
    • /
    • 2005
  • Chitosan, which is a biopolymer, composed of glucosamine units linked by $\beta$-1, 4 glycoside bonds, is rich in shells of crustacean such as crabs and shrimps. Consumption of chitosan has been rapidly increased as a functional food. We examined effects of chitosan on the damages caused by lead (Pb) exposure in rats. Male Sprague-Dawley rats were divided into 8 groups (n = 64), then fed diets containing 3% cellulose (control) or 3% chitosan, each with 4 different lead doses (0 mg/d, 20 mg/d, 50 mg/d, and 100 mg/d) for 4 wks. Lead doses were given 3 times per week by oral administration. Blood lead levels in rats increased depending on the administered doses of lead. Rats fed chitosan diets showed lower blood lead concentration than did their respective controls. Effect of chitosan on the blood lead was more beneficial in rats exposed to lower lead (20 mg/d) than in rats exposed to higher lead (50 mg/d and 100 mg/d). Histological changes in erythrocytes and liver were also examined. Chitosan tended to reduce numbers of basophilic stippling erythrocytes and improve the histological liver changes in rats given various lead doses. The preventive effects of chitosan on liver damages were stronger in rats with higher lead than those with lower lead. These results indicate that chitosan has beneficial effects on both blood toxicological responses and histological damages of erythrocytes and liver induced by the administration of various lead doses.

Radioactive effluents released from Korean nuclear power plants and the resulting radiation doses to members of the public

  • Kong, Tae Young;Kim, Siyoung;Lee, Youngju;Son, Jung Kwon;Maeng, Sung Jun
    • Nuclear Engineering and Technology
    • /
    • v.49 no.8
    • /
    • pp.1772-1777
    • /
    • 2017
  • Korean nuclear power plants (NPPs) periodically evaluate the radioactive gaseous and liquid effluents released from power reactors to protect the public from radiation exposure. This paper provides a comprehensive overview of the release of radioactive effluents from Korean NPPs and the effects on the annual radiation doses to the public. The amounts of radioactive effluents released to the environment and the resulting radiation doses to members of the public living around NPPs were analyzed for the years 2011-2015 using the Korea Hydro & Nuclear Power Co., Ltd's annual summary reports of the assessment of radiological impact on the environment. The results show that tritium was the primary contributor to the activity in both gaseous and liquid effluents. The averages of effective doses to the public were approximately on the order of $10^{-3}mSv$ or $10^{-2}mSv$. Therefore, even though Korean NPPs discharged some radioactive materials into the environment, all effluents were within the regulatory safety limits and the resulting doses were much less than the dose limits.

CR장치와 일반 촬영 장치에서 피폭선량 측정과 촬영조건표 작성에 관한 연구

  • Kim, Heung-Tae;Gwon, Su-Il;Gwon, Dal-Gwan;Kim, Hwa-Gon
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.3 no.1
    • /
    • pp.76-84
    • /
    • 1997
  • We tried to find any factor to reduce the exposure dose with ST-VA type generator which has the higher exposure dose. The guideline recommended by the provisions of IAEA regulation is being used at the time of radiation exposure and almost of those equipments used for this study had less amount of doses than those in the guideline. The FCR may be possible to decrease a certain amount of dose with effective applications of it's automatic image compensation utilities and the verifying function in PACS. Next time, it is required to add a great number of hospitals for wide range of studios and measurements, and make standard exposure Control table which will bing in practice, material decrease of dose volumes when radiation exposure.

  • PDF

Occupational Radiation Exposure in Korea: 2002 (2002년 국내 방사선 작업종사자의 직업군별 피폭선량)

  • Jeong, Je-Ho;Kwon, Jeong-Wan;Lee, Jai-Ki
    • Journal of Radiation Protection and Research
    • /
    • v.30 no.4
    • /
    • pp.175-183
    • /
    • 2005
  • Dose distribution of Korean radiation workers classified by occupational categories was analyzed. Statistics of the occupational radiation exposure(ORE) in 2002 of the radiation workers in diagnostic and dental radiology were obtained from the Korea Food and Drug Agency(KFDA) who maintains the database for individual radiation dose records. Corresponding statistics for the rest of radiation workers were obtained by processing the individual annual doses provided by the Korea Radioisotope Association(KRIA) after deletion of individual information. The ORE distribution was classified in term of 28 occupational categories, annual individual dose levels, age groups and gender of 52733 radiation workers as of the year of 2002. The total collective dose was 66.4 man-Sv and resulting average individual ORE was 1.26 mSv. Around 80% of the workers were exposed to minimal doses less than 1.2 mSv. However, it appeared that the recorded doses exceeded 20 mSv for 43 workers in the industrial radiography and for 147 workers in the field of radiology. Particularly, recorded doses of 23 workers in radiology exceeded the annual dose limits of 50 mSv, which is extraordinary when the working environment is considered. It is uncertain whether those doses are real or caused by careless placing of dosimeters in the imaging rooms while the X-ray units are in operation. No one in the workforce of 16 operating nuclear power plant units was exposed over 20 mSv in 2002. Number of workers was the largest in their 30's of age and the mean individual dose was the highest in their 20's. Women were around 20% of the radiation workers and their average dose was around one half of that of man workers.

Dose estimation of cone-beam computed tomography in children using personal computer-based Monte Carlo software (PCXMC 소프트웨어를 이용한 소아에서의 CBCT 환자선량 평가)

  • Kim, Eun-Kyung
    • The Journal of the Korean dental association
    • /
    • v.58 no.7
    • /
    • pp.388-397
    • /
    • 2020
  • Objective: The purpose of the study was to calculate the effective and absorbed organ doses of cone-beam computed tomography (CBCT) in pediatric patient using personal computer-based Monte Carlo (PCXMC) software and to compare them with those measured using thermoluminescent dosimeters (TLDs) and anthropomorphic phantom. Materials and Methods: Alphard VEGA CBCT scanner was used for this study. A large field of view (FOV) (20.0 cm × 17.9 cm) was selected because it is a commonly used FOV for orthodontic analyses in pediatric patients. Ionization chamber of dose-area product (DAP) meter was located at the tube side of CBCT scanner. With the clinical exposure settings for a 10-year-old patient, DAP value was measured at the scout and main projection of CBCT. Effective and absorbed organ doses of CBCT at scout and main projection were calculated using PCXMC and PCXMCRotation software respectively. Effective dose and absorbed organ doses were compared with those obtained by TLDs and a 10-year-old child anthropomorphic phantom at the same exposure settings. Results: The effective dose of CBCT calculated by PCXMC software was 292.6 μSv, and that measured using TLD and anthropomorphic phantom was 292.5 μSv. The absorbed doses at the organs largely contributing to effective dose showed the small differences between two methods within the range from -18% to 20%. Conclusion: PCXMC software might be used as an alternative to the TLD measurement method for the effective and absorbed organ dose estimation in CBCT of large FOV in pediatric patients.

  • PDF