• Title/Summary/Keyword: Exposure conditions

Search Result 1,577, Processing Time 0.024 seconds

Doses of Pediatric and X-ray Examination Assistants according to Changes in Pediatric X-ray Exposure Conditions (소아 X선 촬영조건 변화에 따른 소아 및 촬영보조자 선량)

  • Beom-Jin Jang;Ha-Yun Nam;Hye-Min Shin;Dong-Min Yun;Seung-Kook Lee;In-Hwa Jang;Sungchul Kim
    • Journal of radiological science and technology
    • /
    • v.46 no.5
    • /
    • pp.409-415
    • /
    • 2023
  • Although pediatric X-ray examinations are continuously increasing, there are not many studies on the radiation exposure to children and X-ray examination assistants according to X-ray Exposure conditions. Accordingly, we measured the radiation exposure dose of pediatric and X-ray examination assistants according to the standard guidelines and clinical average X-ray Exposure conditions when X-ray examination 10-year-old children. The effective dose and organ dose to pediatric were measured using an Dose area production meter and Monte Carlo-based PCXMC program, and the exposure dose of X-ray examination assistants was measured using an ion-chamber. When performing abdominal supine AP projection, the effective dose to children was up to 2.38 times higher under clinical average X-ray Exposure conditions than the standard guidelines. In addition, during abdominal supine AP projection, the radiation exposure dose to the X-ray examination assistants was highest on the hands at 0.0148 ~ 0.0709 mSv, and exposure dose could be reduced by up to 35% when wearing protective gloves. In conclusion, because the X-ray Exposure conditions used in clinical are unnecessarily high, unnecessary medical radiation exposure could be reduced if appropriate X-ray Exposure conditions and the radiation field area were minimized and the assistant wore shielding gloves.

Effects of Ag Nanoparticle Flow Rates on the Progress of the Cell Cycle Under Continuously Flowing "Dynamic" Exposure Conditions

  • Park, Min Sun;Yoon, Tae Hyun
    • Bulletin of the Korean Chemical Society
    • /
    • v.35 no.1
    • /
    • pp.123-128
    • /
    • 2014
  • In this study, we have investigated the flow rate effects of Ag nanoparticle (NP) suspensions on the progress of the cell cycle by using a microfluidic image cytometry (${\mu}FIC$)-based approach. Compared with the conventional "static" exposure conditions, enhancements in G2 phase arrest were observed for the cells under continuously flowing "dynamic" exposure conditions. The "dynamic" exposure conditions, which mimic in vivo systems, induced an enhanced cytotoxicity by accelerating G2 phase arrest and subsequent apoptosis processes. Moreover, we have also shown that the increases in delivered NP dose due to the continuous supply of Ag NPs contributed dominantly to the enhanced cytotoxicity observed under the "dynamic" exposure conditions, while the shear stress caused by these slowly flowing fluids (i.e., flow rates of 6 and $30{\mu}L/h$) had only a minor influence on the observed enhancement in cytotoxicity.

A Study on Quality Control for Medical Image by Using Deviation Index of Digital Radiology (디지털 방사선 영상의 편차지수를 이용한 의료영상 품질관리에 관한 연구)

  • Jeong, Hoi-Woun;Min, Jung-Whan
    • Journal of radiological science and technology
    • /
    • v.43 no.2
    • /
    • pp.115-121
    • /
    • 2020
  • In a digital radiation system using a Flat Panel Detector, we attempted to the quality control of digital radiography system using the Exposure Index and Deviation Index. Calibration was performed with the radiation quality suggested by the International Electrotechnical Commission, and through an experiment using a phantom, appropriate inspection radiation conditions applicable to medical institutions were selected. The study was conducted using the selected radiation conditions. Through those chest posterior anterior image, information such as examination conditions and exposure index was obtained. The deviation index was derived by analyzing the exposure index based on the target exposure index calculated by the phantom study. As for the analyzed exposure index, 97.1% was distributed within the range of ± 2.0 based on the deviation index. Quality control of medical images should be performed through management of inspection conditions through exposure index and deviation index and management of medical images.

Comparison of Accuracy and Output Waveform of Devices According to Rectification Method (정류방식에 따른 장치의 정확도와 출력 파형의 비교)

  • Lee, In Ja
    • Journal of radiological science and technology
    • /
    • v.41 no.6
    • /
    • pp.603-610
    • /
    • 2018
  • This study examined the following: accuracy of the exposure conditions in the inverter device and three-phase device; output waveform over the exposure conditions; and average and standard deviation of the output waveform. After assessing whether the dose corresponding to the theoretical dose was presented, the following conclusions were obtained: 1. The accuracy of the tube voltage(kVp) and tube current(mA) exposure time(sec) was within the tolerable level prescribed in Korea's Safety Management Standards. In the error, Inverter device was large the tube voltage and exposure time, the three-phase device was large the tube current. 2. In terms of the output waveform of the exposure conditions and the average and standard deviation of the output waveform, the higher tube voltage and larger tube current resulted in greater standard deviation in pulsation. Moreover, the standard deviation of pulsation was shown to be greater in the inverter device than the three-phase device; there was also greater standard deviation in the inverter device considering the exposure time. 3. Regarding the exposure conditions over the output dose, all linearity showed the coefficient of variation which had an allowable limit of error within 0.05. Although the output dose ratio for the inverter device was 1.00~1.10 times no difference that of the three-phase device, there was almost no difference in dose ratio between the tube currents.

Evaluation on the Sulfate Attack Resistance of Cement Mortars with Different Exposure Conditions (노출조건에 따른 시멘트 모르타르의 황산염침식 저항성 평가)

  • Lee, Seung Tae
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.32 no.6A
    • /
    • pp.427-435
    • /
    • 2012
  • In order to evaluate the effects of exposure conditions on the resistance to sulfate attack of normal and blended cement mortars, several mechanical characteristics of the mortars such as expansion, strength and bulk density were regularly monitored for 52 cycles under sodium sulfate attack. The mortar specimens were exposed to 3 different types of exposure conditions; 1) continuous full immersion(Exposure A), continuous half-immersion(Exposure B) and cyclic wetting-drying(Exposure C). Experimental results indicated that the maximum deterioration was noted in OPC mortar specimens subjected to Exposure B, showing the wide cracks in the portions where attacking solution is adjacent to air. Additionally, the beneficial effect of ground granulated blast-furnace slag and silica fume was clearly observed showing a superior resistance against sodium sulfate attack, because of its lower permeability and densified structure. Thus, it is suggested that when concrete made with normal cement is exposed to sulfate environment, proper considerations on the exposure conditions should be taken.

The effect of the exposure to hazard factors on job satisfaction in employees (임금근로자의 작업장 유해위험요인 노출이 근로환경에 대한 만족도에 미치는 영향)

  • Park, Won Yeol
    • Journal of the Korea Safety Management & Science
    • /
    • v.16 no.3
    • /
    • pp.257-266
    • /
    • 2014
  • This study was planned to investigate the effect of the exposure to hazard factors on work environment satisfaction. Existing researches about job satisfaction have focused on the general working conditions, such as working hours, wage, human relationship, job task and so on. Korean Working Conditions Survey was used for this study because that relevant questions were included. The effect of the exposure to hazard factors on work environment satisfaction may be produced by hierarchical regression analysis because of comparison with existing model for work environment satisfaction. The exposure to hazards factors were statistically significant effect on work environment satisfaction after adjusting other confounding variables, such as gender, age, educational level, job security, work hour, work load, work autonomy, social support, etc. This study has some limitation because that KWCS was cross sectional survey. Some researches about the causal effect and its mechanism may be suggested as future study.

Self-Healing Investigation of Bisphenol F-Type Epoxy-Modified Mortars with Expansive Admixtures Under Outdoor Exposure Conditions (환경조건에 따른 팽창성 혼화재 및 비스페놀 F형 에폭시수지 병용 모르타르의 자기치유 검토)

  • Park, Seung-Min;Kim, Wan-Ki
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2017.05a
    • /
    • pp.22-23
    • /
    • 2017
  • The purpose of this study is to ascertain self-healing function on microcracks in bisphenol F-type epoxy-modified mortars using expansive admixtures. The specimens are prepared with various polymer-binder ratios of 0, 5, 10, 20%, expansive admixture contents of 0% and 10%, a sodium carbonate content of 0.25%, and subjected to exposure conditions of CR1, CR2, CR3 and CR4. The specimens are tested for self-healing effect, porosity and FE-SEM analysis. As a result, self-healing effects of bisphenol F-type EPMMs with expansive admixtures are visible in all of the outdoor exposure conditions. In particular, exposure conditions of CR3 and CR4 are most noticeable. And the porosity of EPMMs is reduced with an increase in the polymer-binder ratio, and is considerably smaller than that of unmodified mortar.

  • PDF

Comparison of ESD and Major Organ Absorbed Doses of 5-Year-Old Standard Guidelines and Clinical Exposure Conditions (소아 5세 표준촬영 가이드라인과 임상 촬영조건의 입사표면선량과 주요 장기흡수선량 비교)

  • Kang, A-Rum;Lee, In-Ja;Ahn, Sung-Min
    • Journal of radiological science and technology
    • /
    • v.40 no.3
    • /
    • pp.355-361
    • /
    • 2017
  • Pediatrics are more sensibility to radiation than adults and because they are organs that are not completely grown, they have a life expectancy that can be adversely affected by exposure. Therefore, the management of exposure dose is more important than the case of adult. The purpose of this study was to determine the suitability of the 10 year old phantom for the 5 year old pediatric's recommendation and the incident surface dose, and to measure the organ absorbed dose. This study is compared the organ absorbed dose and the entrance surface dose in the clinical conditions at 5 and 10 years old pediatric. Clinical 5 year old condition was slightly higher than recommendation condition and 10 year old condition was very high. In addition, recommendation condition ESD was found to be 43% higher than the ESD of the 5 year old group and the ESD of the 10 year old group was 126% higher than that of the 5 year old group. The recommended ESD at 5 years old and the ESD according to clinical imaging conditions were 31.6%. There was no significant difference between the 5 year old recommended exposure conditions and the organ absorbed dose due to clinical exposure conditions, but there was a large difference between the Chest and Pelvic. However, it was found that there was a remarkable difference when comparing the organ absorbed dose by 10 year clinical exposure conditions. Therefore, more detailed standard exposure dose for the recommended dose of pediatric should be studied.

Evaluation of Dose Reduction and Maintaining Image Quality according to Exposure Factors of Cone Beam Computed Tomography (콘빔전산화단층촬영에서 노출 조건에 따른 화질 유지 및 선량 감소에 대한 평가)

  • Han, Jin-Woo
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.4
    • /
    • pp.353-360
    • /
    • 2020
  • This research aims at suggesting exposure condition that shows maintaining the value of the physical image quality factor by decreasing tube voltage and tube current from the standard exposure condition(80 kV, 7 mA) of a CBCT apparatus. To measure the value of the physical image quality factor, modular transfer function(MTF) was analyzed and dose-area product(DAP) was used for the measurement of exposure dose. CBCT images of a Sedentex IQ phantom were obtained under 15 exposure conditions of different combination of tube voltage(80, 78, 76 kV) and tube current(7, 6, 5, 4, 3 mA) and MTF 10 was calculated under each exposure conditions. There were no significant differences in MTF 10 under 80 kV-6 mA, 80 kV-5 mA exposure conditions in comparison with standard exposure condition. Based on the results of this research, 80 kV-5 mA condition are expected to be able to reduce exposure dose with maintaining the value of the physical image quality factor of the standard exposure condition.

Work Conditions and Practices in Norwegian Fire Departments From 1950 Until Today: A Survey on Factors Potentially Influencing Carcinogen Exposure

  • Jakobsen, Jarle;Babigumira, Ronnie;Danielsen, Marie;Grimsrud, Tom K.;Olsen, Raymond;Rosting, Cecilie;Veierod, Marit B.;Kjaerheim, Kristina
    • Safety and Health at Work
    • /
    • v.11 no.4
    • /
    • pp.509-516
    • /
    • 2020
  • Background: Meta-analyses have shown firefighters to be at an increased risk of several cancer types. Occupational carcinogen exposure may explain these increased risks. This study aims to describe Norwegian fire departments' work conditions from 1950 until today, focusing on factors relevant for potential occupational carcinogen exposure. Methods: With the help of a reference group, we developed a questionnaire on topics related to occupational exposure to carcinogens for the period 1950-2018. Selected Norwegian fire departments provided department-specific responses. Results: Sixteen departments, providing fire services for 48% of the Norwegian population as of 2019 and mainly consisting of professional firefighters, responded to our questionnaire. The introduction of synthetic firefighting foams, more regular live fire training, the introduction of chemical diving, and a higher number of diesel-driven fire service vehicles were identified as changes thought to increase exposure to occupational carcinogens. Changes thought to decrease exposure included the switch from negative to positive pressure self-contained breathing apparatuses, the use of self-contained breathing apparatuses during all phases of firefighting, the use of ventilating fans during firefighting, increased attention to flammable materials used during live fire training, increased attention to handling and cleaning of turnout gear and other equipment, and installment of exhaust removal systems in apparatus bays. Conclusion: Norwegian fire departments' work conditions have seen several changes since 1950, and this could influence firefighters' occupational carcinogen exposure. A peak of carcinogen exposure may have occurred in the 1970s and 1980s before recent changes have reduced exposure.