• 제목/요약/키워드: Exposure chamber

검색결과 319건 처리시간 0.03초

Survival of Microorganisms on Antimicrobial Filters and the Removal Efficiency of Bioaerosols in an Environmental Chamber

  • Kim, Sung Yeon;Kim, Misoon;Lee, Sunghee;Lee, JungEun;Ko, GwangPyo
    • Journal of Microbiology and Biotechnology
    • /
    • 제22권9호
    • /
    • pp.1288-1295
    • /
    • 2012
  • Exposure to bioaerosols causes various adverse health effects including infectious and respiratory diseases, and hypersensitivity. Controlling exposure to bioaerosols is important for disease control and prevention. In this study, we evaluated the efficacies of various functional filters coated with antimicrobial chemicals in deactivating representative microorganisms on filters or as bioaerosols. Tested functional filters were coated with different chemicals that included (i) Ginkgo and sumac, (ii) Ag-apatite and guanidine phosphate, (iii) $SiO_2$, ZnO, and $Al_2O_3$, and (iv) zeolite. To evaluate the filters, we used a model ventilation system (1) to evaluate the removal efficiency of bacteria (Escherichia coli and Legionella pneumophila), bacterial spores (Bacillus subtilis spore), and viruses (MS2 bacteriophage) on various functional filters, and (2) to characterize the removal efficiency of these bioaerosols. All experiments were performed at a constant temperature of $25^{\circ}C$ and humidity of 50%. Most bacteria (excluding B. subtilis) rapidly decreased on the functional filter. Therefore, we confirmed that functional filters have antimicrobial effects. Additionally, we evaluated the removal efficiency of various bioaerosols by these filters. We used a six-jet collision nebulizer to generate microbial aerosols and introduced it into the environmental chamber. We then measured the removal efficiency of functional filters with and without a medium-efficiency filter. Most bioaerosol concentrations did not significantly decrease by the functional filter only but decreased by a combination of functional and medium-efficiency filter. In conclusion, functional filters could facilitate biological removal of various bioaerosols, but physical removal of these by functional was minimal. Proper use of chemical-coated filter materials could reduce exposure to these agents.

X선 진단영역 에너지 측정을 위한 Photo-Diode 선량계(PD-2000)의 개발 (The development of photo-diode dosimeter(PD-2000) for the diagnostic X-ray Energy)

  • 김성철;이우철;김정민
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제23권2호
    • /
    • pp.27-32
    • /
    • 2000
  • It was produced radiation dosimeter used photo-diodes for which ionization by x-ray was applied and evaluated the value of utility in clinics as compared with ion-chamber. The result obtained were as follows : 1. Comparison of ion-chamber with photo-diode dosimeter's x-ray output by the change of x-ray tube voltage, and the ratio of ion-chamber to diode was $0.96{\sim}1.02$ which was not affected by x-ray beam quality. 2. The ratio of ion-chamber to diode was 0.96 by change of tube current and 0.97 by change of exposure time that is not affected by x-ray quantity. 3. The ratio of ion-chamber to diode was $0.97{\sim}1.04$ by thickness and $0.93{\sim}1.10$ by radiation field that is little affected by second ray quantity. 4. Reproducibility of photo-diode dosimeter was 0.011(CV) and it is a good result. 5. Photo-diode dosimeter was affected by the surface angle of detector over 30 degrees. Produced dosimeter was small, light, and meets good result compared with ionization chamber. It was expected come into wide use in clinic.

  • PDF

휴대형 고순도 게르마늄검출기에 대한 스펙트럼-조사선량율 변환연산자의 결정 (Determination of Spectrum-Exposure Rate Conversion Factor for a Portable High Purity Germanium Detector)

  • 곽상수;박종묵;노성기
    • Journal of Radiation Protection and Research
    • /
    • 제13권2호
    • /
    • pp.29-40
    • /
    • 1988
  • 환경방사선 측정에 이용되는 휴대형 고순도 게르마늄검출기에 대한 스펙트럼-조사선량율 변환연산자를 원판형선원의 공간분포함수와 검출기의 평면에 대한 측정효율식을 적용하여 이론적으로 유도했다. 이와 같이 구한 변환연산자와 휴대형 고순도 게르마늄검출기를 이용해 한국에너지연구소내에서 방사선 조사선량율을 측정했다. 측정한 조사선량율을 이미 알려진 3'${\phi}\;{\times}$3'NaI(Tl) 섬광검출기에 대한 변환연산자를 적용해 NaI(Tl)검출기로 측정한 조사선량율과 가압형 이온전리함으로 측정한 값과 비교했다. 고순도 게르마늄 검출기로 얻은 결과는 NaI(Tl) 검출기와 가압형 이온전리함으로 얻은 값보다 약 17-29% 낮음을 보여주었다. 이 차이는 다른 문헌에서 보인 차이와 거의 같았다. 본 논문에서 제시한 스펙트럼-조사선량율 변환연산자는 탁상용 계산기로 쉽게 계산할 수 있으며 환경방사선의 측정에 사용되는 여러 검출기에 대해서도 쉽게 적용할 수 있는 장점이 있고 지각에서 방출되는 각 핵종별로 조사선량율을 구할 수 있는 장점이 있다.

  • PDF

Effects of Long-term Exposure of High and Low Humidity on Thin-film Humidity Sensors

  • Lee, Sang-Wook;Choi, Byung Il;Kim, Jong Chul;Woo, Sang-Bong
    • 센서학회지
    • /
    • 제27권6호
    • /
    • pp.368-373
    • /
    • 2018
  • The effects of long-term exposure of high and low humidity on thin-film humidity sensors are investigated. Five commercially available thin-film humidity sensors are initially calibrated in a humidity chamber as a reference before longterm exposure to high and low humidity. Then, the sensors are kept in a high-humidity environment (~95 %rh) for four months. After the exposure, the sensors are calibrated in the same manner as the initial calibration. Consequently, the device reading values from the humidity sensors are elevated up to about 5 %rh. Interestingly, the degree of elevation by the high-humidity exposure shows a negative correlation with the price of the humidity sensors. Humidity sensors are then kept in a low-humidity environment (~10 %rh) for another four months. After the exposure, a calibration similar to the initial calibration is performed. As a result, the device reading from humidity sensors is decreased, indicating a recovery from the effect of high-humidity exposure. The durability test conducted in this study provides experimental evidence for the use of thin-film humidity sensors in high-humidity environments such as greenhouses and food factories for a long period of time.

디지털 방사선 시스템(DR)의 자동노출제어장치 이용 시 이온 챔버의 성능 평가를 위한 엔트로피 분석법의 유용성과 최적의 챔버 조합 모델 구현 연구 (Study on Usefulness of Entrance Surface Dose (ESD), Entropy Analysis Method to Evaluate Ionization Chamber Performance and Implementation of Optimal Chamber Combination Model when using Automatic Exposure Control (AEC) Device in Digital Radiography (DR))

  • 황준호;최지안;이경배
    • 한국방사선학회논문지
    • /
    • 제14권4호
    • /
    • pp.375-383
    • /
    • 2020
  • 본 연구는 자동노출제어장치 사용 시 이온 챔버의 성능과 조합에서 비롯된 문제를 정량적으로 분석하는 방법론을 제시하고 디지털 방사선 시스템의 성능을 최적화하고자 하였다. 실험방법은 복부와 골반부 검사에 사용된 파라미터의 X선질을 백분율 평균오차(PAE; Percentage Average Error)와 반가층(HVL; Half Value Layer)으로 평가하였다. 그 후 세 가지 이온 챔버를 조합했을 때의 입사표면선량(ESD; Entrance Surface Dose)과 엔트로피(Entropy)를 산출하여 방사선 출력의 안정성과 영상 품질을 분석하였다. 그 결과 실험에 사용한 디지털 방사선 시스템의 X선질은 모두 정상 범위의 백분율 평균오차와 반가층을 보였다. 입사표면선량은 챔버의 조합에 비례하여 증가하였고, 엔트로피는 세 개의 챔버가 조합됐을 때를 제외하고는 이온 챔버의 조합에 비례하여 증가하였다. 결론적으로 입사표면선량과 엔트로피를 이용한 분석은 이온 챔버의 성능과 조합의 문제를 평가하는데 유용한 방법인 것을 알 수 있었으며, 두 개 이하의 이온 챔버를 조합했을 때 디지털 방사선 시스템의 성능을 최적으로 유지할 수 있음을 알 수 있었다.

LC50 Determination of tert-Butyl Acetate using a Nose Only Inhalation Exposure in Rats

  • Yang, Young-Su;Lee, Jin-Soo;Kwon, Soon-Jin;Seo, Heung-Sik;Choi, Seong-Jin;Yu, Hee-Jin;Song, Jeong-Ah;Lee, Kyu-Hong;Lee, Byoung-Seok;Heo, Jeong-Doo;Cho, Kyu-Hyuk;Song, Chang-Woo
    • Toxicological Research
    • /
    • 제26권4호
    • /
    • pp.293-300
    • /
    • 2010
  • tert-Butyl acetate (TBAc) is an organic solvent, which is commonly used in architectural coatings and industrial solvents. It has recently been exempted from the definition of a volatile organic compound (VOC) by the Air Resources Board (ARB). Since the use of TBAc as a substitute for other VOCs has increased, thus its potential risk in humans has also increased. However, its inhalation toxicity data in the literature are very limited. Hence, inhalation exposure to TBAc was carried out to investigate its toxic effects in this study. Adult male rats were exposed to TBAc for 4 h for 1 day by using a nose-only inhalation exposure chamber (low dose, $2370\;mg/m^3$ (500 ppm); high dose, $9482\;mg/m^3$ (2000 ppm)). Shamtreated control rats were exposed to clean air in the inhalation chamber for the same period. The animals were killed at 2, 7, and 15 days after exposure. At each time point, body weight measurement, bronchoalveolar lavage fluid (BALF) analysis, histopathological examination, and biochemical assay were performed. No treatment-related abnormal effects were observed in any group according to time course. Based on those findings, the median lethal concentration ($LC_{50}$) of TBAc was over $9482\;mg/m^3$ in this study. According to the MSDS, the 4 h $LC_{50}$ for TBAc for rats is over $2230\;mg/m^3$. We suggested that this value is changed and these findings may be applied in the risk assessment of TBAc which could be beneficial in a sub-acute study.

Effect of Nano-sized Carbon Black Particles on Lung and Circulatory System by Inhalation Exposure in Rats

  • Kim, Jong-Kyu;Kang, Min-Gu;Cho, Hae-Won;Han, Jeong-Hee;Chung, Yong-Hyun;Rim, Kyung-Taek;Yang, Jeong-Sun;Kim, Hwa;Lee, Moo-Yeol
    • Safety and Health at Work
    • /
    • 제2권3호
    • /
    • pp.282-289
    • /
    • 2011
  • Objectives: We sought to establish a novel method to generate nano-sized carbon black particles (nano-CBPs) with an average size smaller than 100 nm for examining the inhalation exposure risks of experimental rats. We also tested the effect of nano-CBPs on the pulmonary and circulatory systems. Methods: We used chemical vapor deposition (CVD) without the addition of any additives to generate nano-CBPs with a particle size (electrical mobility diameter) of less than 100nm to examine the effects of inhalation exposure. Nano-CBPs were applied to a nose-only inhalation chamber system for studying the inhalation toxicity in rats. The effect on the lungs and circulatory system was determined according to the degree of inflammation as quantified by bronchoalveolar lavage fluid (BALF). The functional alteration of the hemostatic and vasomotor activities was measured by plasma coagulation, platelet activity, contraction and relaxation of blood vessels. Results: Nano-CBPs were generated in the range of 83.3-87.9 nm. Rats were exposed for 4 hour/day, 5 days/week for 4 weeks to $4.2{\times}10^6$, $6.2{\times}10^5$, and $1.3{\times}10^5$ particles/$cm^3$. Exposure of nano-CBPs by inhalation resulted in minimal pulmonary inflammation and did not appear to damage the lung tissue. In addition, there was no significant effect on blood functions, such as plasma coagulation and platelet aggregation, or on vasomotor function. Conclusion: We successfully generated nano-CBPs in the range of 83.3-87.9 nm at a maximum concentration of $4.2{\times}10^6$ particles/$cm^3$ in a nose-only inhalation chamber system. This reliable method can be useful to investigate the biological and toxicological effects of inhalation exposure to nano-CBPs on experimental rats.

전신 노출 환경에서 노출 조건에 따른 마우스와 랫트의 SAR 값 변화량 분석 (Investigation of the Variation of SAR Values in Mice and Rats Depending on the Exposure Conditions in Whole-Body Exposure Environments)

  • 문지연;서민경;김태홍;백정기
    • 한국전자파학회논문지
    • /
    • 제24권2호
    • /
    • pp.161-167
    • /
    • 2013
  • 전자파 노출에 대한 동물실험에서는 실험동물 내에서의 SAR 값을 정확히 추정하는 것이 매우 중요하다. 본 논문에서는 동물의 수와 동물 간의 거리, 물병의 존재 여부에 따른 마우스(mouse)와 랫트(rat) 내의 SAR 값의 변화량을 분석하였다. 마우스와 랫트는 전자파 잔향실(reverberation chamber) 내에 위치한 케이지(cage) 안에서 CDMA, WCDMA 주파수의 전자파에 노출시켰다. 시뮬레이션 결과, 물병의 물의 양에 대한 SAR 값의 변화보다 실험동물의 마릿수가 증가할 때 SAR 값의 변화가 더 컸다. 마우스와 랫트가 케이지 내에 한 마리만 있을 경우에 비해, 마우스는 케이지 내에 세 마리가 있을 때 전신 평균 SAR 값의 변화량은 850 MHz와 1,950 MHz에서 각각 최대 15.3 %, 14.9 %이며, 랫트의 경우에는 케이지 내에 두 마리가 있을 때 각각의 주파수에서 최대 18.7 %, 21.1 %의 변화를 보였다. 결론적으로 실 노출 환경에서의 노출 조건에 따른 SAR 값의 변화량은 무시할 수 없다는 결론을 도출하였다.

Effect of SO2 - NO2 fumigation on wooden tree seedlings in open top chamber system

  • Katiyar, Vinita
    • Advances in environmental research
    • /
    • 제3권4호
    • /
    • pp.355-365
    • /
    • 2014
  • The present study has been performed on one year old tree saplings of Azadirachta indica (L.), Cassia siamea (L.), Dalbergia sissoo (Roxb.), Eucalyptus rostrata (L.), Mangifera indica (L.) and Schyzygium cumini (L.) in order to assess the effect of exposure of $SO_2-NO_2$, alone and combination of two gases. Tree saplings have been exposed to an average of $495{\mu}g\;m^{-3}$ $SO_2$ and $105{\mu}g\;m^{-3}$ $NO_2$ for 40 d at the rate of $4hd^{-1}$ during 10:00 am to 01:00 pm in OTC. Total chlorophyll, specific leaf area (SLA), nitrate reductase (NR) activity, foliar protein, free proline content and free amino acids (AAs) of foliage have been the plant parameters, taken into consideration to evaluate the effect of gaseous exposure. Exposure of two gases has caused reduction in total chlorophyll content (P < 0.05, 0.01). Physiological and biochemical process has been seemed to be altered noticeable due to the combined effect of $SO_2+NO_2$ followed by $SO_2$ alone (P < 0.05, 0.01). $NO_2$ mediated stress has produced, stimulatory and inhibitory responses in tree saplings. Results reveal that tree saplings have been attempted to absorb the $NO_2$ through N assimilation pathway. E. rostrata, C. siamea have been emerged as moderate tolerant to $SO_2$ mediated stress followed by A. indica. Response pattern of S. cumini, M. indica and D. sissoo set them as good indicators of $SO_2-NO_2$ exposure. Effects of two gases on tree saplings have been found to be synergistic.

소아 X선 촬영조건 변화에 따른 소아 및 촬영보조자 선량 (Doses of Pediatric and X-ray Examination Assistants according to Changes in Pediatric X-ray Exposure Conditions)

  • 장범진;남하윤;신혜민;윤동민;이승국;장인화;김성철
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제46권5호
    • /
    • pp.409-415
    • /
    • 2023
  • Although pediatric X-ray examinations are continuously increasing, there are not many studies on the radiation exposure to children and X-ray examination assistants according to X-ray Exposure conditions. Accordingly, we measured the radiation exposure dose of pediatric and X-ray examination assistants according to the standard guidelines and clinical average X-ray Exposure conditions when X-ray examination 10-year-old children. The effective dose and organ dose to pediatric were measured using an Dose area production meter and Monte Carlo-based PCXMC program, and the exposure dose of X-ray examination assistants was measured using an ion-chamber. When performing abdominal supine AP projection, the effective dose to children was up to 2.38 times higher under clinical average X-ray Exposure conditions than the standard guidelines. In addition, during abdominal supine AP projection, the radiation exposure dose to the X-ray examination assistants was highest on the hands at 0.0148 ~ 0.0709 mSv, and exposure dose could be reduced by up to 35% when wearing protective gloves. In conclusion, because the X-ray Exposure conditions used in clinical are unnecessarily high, unnecessary medical radiation exposure could be reduced if appropriate X-ray Exposure conditions and the radiation field area were minimized and the assistant wore shielding gloves.