• Title/Summary/Keyword: Exposure Limit

Search Result 548, Processing Time 0.032 seconds

Strengthening the Occupational Exposure Limit for 1-Bromopropane according to the Results of Epidemiological Studies and Exposure Status (1-브로모프로판의 노출 실태와 역학조사에 따른 노출기준 강화에 관한 연구)

  • Ha, Kwonchul;Kim, Seung Won;Phee, Young Gyu;Lee, Naroo
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.30 no.3
    • /
    • pp.270-279
    • /
    • 2020
  • Objective: The aim of this study was to propose revision of the occupational exposure limit(OEL) for 1-Bromopropane(1-BP) following a review of the appropriateness of the standard in light of increasing epidemiological data and handling risk. Materials and Methods: The results of toxicity and epidemiologic investigations for 1-BP and agencies' OELs were compared and reviewed through a literature review. In order to investigate the status of 1-BP handling in South Korea, data from work environment actual condition survey results and work environment measurement results were used. Results: The toxicity of 1-BP, such as central nervous system(CNS) damage, peripheral neuropathy, hematological adverse effects, and developmental and reproductive toxicity(male and female) has been reported. ACGIH recommends 0.1 ppm as a TLV-TWA value, but the OEL of South Korea stands at 25 ppm, which is 250 times higher than the TLV-TWA. Although 1-BP is a specially managed substance under the Industrial Safety and Health Law, the currently applied OEL cannot be said to be a safe level based on the results of epidemiological studies to date. In a work environment measurement in 2017, the total number of samples was 626, which were derived from 78 industries, and the average concentration was 1.173 ppm(standard deviation 2.88). Conclusions: To protect the health of workers handling 1-BP, estimated to be 780 in South Korea, it is necessary to strengthen the OEL(TWA) to a level of 0.3 ppm(lower than the 0.34 ppm with known toxic effects), which is believed to be safe as a result of epidemiological investigation. "Skin" notation should be recommended.

Practical Radiation Safety Control: (I) Application of Annual Limit on Intake and Derived Air Concentration (방사선안전관리 실무: (I) 연간섭취한도와 유도공기중농도의 적용)

  • Kim, Hyun Kee
    • Journal of Radiation Protection and Research
    • /
    • v.38 no.4
    • /
    • pp.234-236
    • /
    • 2013
  • Some of radioactive contamination is unavoidable in the facilities using the unsealed radioactive material. The primary purpose of radioactive contamination control in the workplace with contamination concern is the effects from the potential intake of radioactive material into the body. This paper provides procedures to estimate the level of internal exposure for the worker based on the conservative assumptions and simple calculations. They consist of two processes; to calculate air concentration of radioactive material and annual intake by inhalation with contaminated air and to compare each of them to Derived Air Concentration and Annual Limit on Intake mentioned in the related notification. The procedures are applicable to make a decision on practical requirements for monitoring air contamination and internal exposure of worker as follows; needs for measurement of air contamination and internal exposure and acquisition of information on the design of the ventilation system.

Managing Soil Contamination in the United States: Policy and Practice

  • Small, Matthew C.
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2003.10a
    • /
    • pp.58-69
    • /
    • 2003
  • Soil contamination in the United States is managed using a risk-based decision making process. In other words, we don't ask, 'how much soil contamination can be cleaned up\ulcorner' Instead we ask, 'how much contamination can be safely left in place\ulcorner' The determination of 'safe' levels of contamination is based upon the potential for exposure and the toxicity of the contaminants of concern in soil. Potential for exposure is determined by evaluating potential exposure pathways from source to receptor given current or reasonably anticipated land use. Soil cleanup goals are then calculated for any complete exposure pathways based upon toxicity and the route of exposure. In some cases, institutional or engineering controls are also used to limit the potential for exposure. In order to prevent a continuous degradation of environmental quality, risk-based cleanup approaches must be combined with strong contamination prevention programs. In addition, alternative risk management approaches should be incorporated into an overall risk reduction strategy.erall risk reduction strategy.

  • PDF

Relationship between Workers′ Exposure to Airborne Chromium and Blood and Urine Chromium Levels in Plating Process (도금업체 근로자의 공기중 크롬 노출 농도와 요 및 혈중 크롬 농도간의 상관성)

  • 이지태;신용철
    • Journal of Environmental Health Sciences
    • /
    • v.27 no.3
    • /
    • pp.1-10
    • /
    • 2001
  • This study was performed to evaluate chromium in air and chromium concentrations in whole blood and urine of workers at chrome plating factories, and to determine the correlation between environmental and biological chromium levels. This study involved 29 workers as study group and 24 undergraduate students as control group. The geometric means(GM) of airborne hexavalent chromium and total chromium concentrations in the plating factories were 3.4 $\mu\textrm{g}$/㎥ and 10.8 $\mu\textrm{g}$/㎥, respectively. Hexavalent chromium levels in two of total 29 measurements exceeded the korean occupational exposure limit and the American Conference of Governmental Industrial Hygienists Threshold Limit Value(ACGIH-TLV) of 50$\mu\textrm{g}$/㎥. Only one sample for total chromium exceeded the Korea occupational exposure limits, the ACGIH-TLV, and the National Institute for Occupational Safety and Health Recommended Exposure Limits(NIOSH-REL) of 500 $\mu\textrm{g}$/㎥. The GM of chromium concentrations in blood and urine of workers exposed to chromium were 8.4 $\mu\textrm{g}$/L and 11.9 $\mu\textrm{g}$/L. The GM of chromium concentrations in blood and urine of workers exposed to chromium were 8.4 $\mu\textrm{g}$/L and 11.9 $\mu\textrm{g}$/L, respectively, whereas the chromium concentrations in blood and urine of the controls were 1.6 $\mu\textrm{g}$/L and 3.8 $\mu\textrm{g}$/L, respectively. There were statistically significant differences of blood and urine concentrations between study group and control group (p<0.01). The chromium concentrations in urine were most highly related to hexavalent chromium, concentration in air(r=0.642, p<0.01). Also, there was a relatively high correlation between the hexavalent chromium concentrations in air and chromium concentrations in whole blood(r=0.557, p<0.05). These results indicate that whole-blood chromium with urinary chromium could be an indicator of chromium body burden caused by exposure to chromic acid mist in plating operation.

  • PDF

Cases Series of Malignant Lymphohematopoietic Disorder in Korean Semiconductor Industry

  • Kim, Eun-A;Lee, Hye-Eun;Ryu, Hyung-Woo;Park, Seung-Hyun;Kang, Seong-Kyu
    • Safety and Health at Work
    • /
    • v.2 no.2
    • /
    • pp.122-134
    • /
    • 2011
  • Objectives: Seven cases of malignant lymphohematopoietic (LHP) disorder were claimed to have developed from occupational exposure at two plants of a semiconductor company from 2007 to 2010. This study evaluated the possibility of exposure to carcinogenic agents for the cases. Methods: Clinical courses were reviewed with assessing possible exposure to carcinogenic agents related to LHP cancers. Chemicals used at six major semiconductor companies in Korea were reviewed. Airborne monitoring for chemicals, including benzene, was conducted and the ionizing radiation dose was measured from 2008 to 2010. Results: The latency of seven cases (five leukemiae, a Non-Hodgkin's lymphoma, and an aplastic anemia) ranged from 16 months to 15 years and 5 months. Most chemical measurements were at levels of less than 10% of the Korean Occupational Exposure Limit value. No carcinogens related to LHP cancers were used or detected. Complete-shielded radiation-generating devices were used, but the ionizing radiation doses were 0.20-0.22 uSv/hr (background level: 0.21 ${\mu}Sv/hr$). Airborne benzene was detected at 0.31 ppb when the detection limit was lowered as low as possible. Ethylene oxide and formaldehyde were not found in the cases' processes, while these two were determined to be among the 263 chemicals in the list that was used at the six semiconductor companies at levels lower than 0.1%. Exposures occurring before 2002 could not be assessed because of the lack of information. Conclusion: Considering the possibility of exposure to carcinogenic agents, we could not find any convincing evidence for occupational exposure in all investigated cases. However, further study is needed because the semiconductor industry is a newly developing one.

Recommendation of an Occupational Exposure Limit and Legal Control Following an Acute Hepatotoxicity Incident from HCFC-123 (HCFC-123의 급성 독성간질환 발생 사례에 따른 노출기준 및 법 관리 필요성 권고)

  • Lee, Kwon Seob;Jo, Ji hoon;Choi, Bo Kyung;Lee, Hye Lim;Byeon, Sang Hoon
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.28 no.1
    • /
    • pp.80-90
    • /
    • 2018
  • Objectives: This study was performed to propose a domestic occupational exposure limit(OEL) following a health hazard assessment, calculation of a non-carcinogenicity reference concentration worker($RfC_{worker}$) value, and examination of international agencies' exposure limits. It also recommends legal management within the Occupational Safety and Health Act for HCFC-123, which caused an acute hepatotoxicity incident. Methods: An acute hepatotoxicity incident due to the fire extinguishing agent HCFC-123 was investigated. Toxicological hazard and health hazard classifications were examined and a non-carcinogenicity $RfC_{worker}$ value was calculated for HCFC-123. An OEL and the necessity of legal management were recommended as well. Results and Conclusions: An OEL for HCFC-123 of 10 ppm($62.5mg/m^3$), which considered the $RfC_{worker}$ value, 5.56 ppm, produced in dose-response assessment and the exposure level of 19.1-20.9 ppm measured as an eight-hour TWA(time-weighted average) in the incident place, is recommended. HCFC-123 is urged to be included as a chemical requiring legal management in the Occupational Safety and Health Regulations. In addition, it is recommended that a peak exposure of ACGIH be adopted in the Notice of the Ministry of Employment and Labor.

Comparison of Human Blood Cadmium Concentrations using Graphite Furnace Atomic Absorption Spectrometry (GF-AAS) and Inductively Coupled Plasma-mass Spectrometry (ICP-MS) (흑연로 원자 흡광 광도기와 유도 결합 플라즈마 질량 분석기를 이용한 인체 혈중 카드뮴 농도 비교)

  • Kwon, Jung-Yeon;Kim, Byoung-Gwon;Lim, Hyoun-Ju;Seo, Jeong-Wook;Kang, Min-Kyung;Kim, Yu-Mi;Hong, Young-Seoub
    • Journal of Environmental Health Sciences
    • /
    • v.44 no.5
    • /
    • pp.491-501
    • /
    • 2018
  • Objectives: The aims of this study were to compare concentrations and the correspondence of human blood cadmium by using graphite furnace atomic absorption spectrometry (GF-AAS) and inductively coupled plasma-mass spectrometry (ICP-MS), which are representative methods of heavy metal analysis. Methods: We randomly selected 79 people who agreed to participate in the research project. After confirming the linearity of the calibration curves for GF-AAS and ICP-MS, the concentrations of cadmium in a quality control standard material and blood samples were measured, and the correlation and the degree of agreement were compared. Results: The detection limit of ICP-MS (IDL: $0.000{\mu}g/L$, MDL: $0.06{\mu}g/L$) was lower than that of GF-AAS (IDL: $0.085{\mu}g/L$, MDL: $0.327{\mu}g/L$). The coefficient of variation of the quality control standard material showed stable values for both ICP-MS (clinchek-1: 5.35%, clinchek-2: 6.22%) and GF-AAS (clinchek-1: 7.92%, clinchek-2: 5.22%). Recovery was relatively high for both ICP-MS (clinchek-1: 95.1%, clinchek-2: 92.8%) and GF-AAS (clinchek-1: 91.4%, clinchek-2: 98.8%), with more than 90%. The geometric mean, median, and percentile of blood samples were all similar. The agreement of the two instruments compared with the bias of the analytical values found that about 81% of the analytical values were within ${\pm}30%$ of the deviation from the ideal reference line (y=0). As a result of the agreement limit, the value included in the confidence interval was about 94%, which shows high agreement. Conclusion: In this study, we confirmed there was no significant difference in concentrations of a quality control standard material and blood samples. Since ICP-MS showed lower concentrations than GF-AAS at concentrations below the method detection limit of GF-AAS, it is expected that more precise results will be obtained by analyzing blood cadmium with ICP-MS.

Acquisition of HDR image using estimation of scenic dynamic range in images with various exposures (다중 노출 복수 영상에서 장면의 다이내믹 레인지 추정을 통한 HDR 영상 획득)

  • Park, Dae-Geun;Park, Kee-Hyon;Ha, Yeong-Ho
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.45 no.2
    • /
    • pp.10-20
    • /
    • 2008
  • Generally, to acquire an HDR image, many images that cover the entire dynamic range of the scene with different exposure times are required, then these images are fused into one HDR image. This paper proposes an efficient method for the HDR image acquisition with small number of images. First, we estimated scenic dynamic range using two images with different exposure times. These two images contain the upper and lower limit of the scenic dynamic range. Independently of the scene, according to varied exposure times, similar characteristics for both the maximum gray levels in images that include the upper limit and the minimum gray levels in images that include the lower limit are identified. After modeling these characteristics, the scenic dynamic range is estimated using the modeling results. This estimated scenic dynamic range is then used to select the proper exposure times for the acquisition of an HDR image. We selected only three proper exposure times because entire dynamic range of the cameras could be covered by three dynamic range of the cameras with different exposure times. To evaluate the error of the HDR image, experiments using virtual digital camera images were carried out. For several test images, the error of the HDR image using proposed method was comparable to that of the HDR image which utilize more than ten images for the HDR image acquisition.

Behavioral responses and tolerance limits of wild goldeye rockfish Sebastes thompsoni to high temperature exposure (고 수온 노출에 따른 자연산 불볼락 Sebastes thompsoni의 행동반응 및 내성 한계)

  • Sung-Jin Yoon;Jin-Hyeok Park
    • Korean Journal of Environmental Biology
    • /
    • v.40 no.3
    • /
    • pp.247-254
    • /
    • 2022
  • To investigate the tolerance limit and critical thermal maximum (CTM), behavioral responses of wild goldeye rockfish Sebastes thompsoni according to exposure to high water temperature were observed using a continuous behavior tracking system. As a result, behavioral index (BI) of S. thompsoni in each temperature (20.0, 25.0, and 30.0℃) showed a significant difference (p<0.05) when compared with the value measured in a stable condition of 15.0℃. The activity level of S. thompsoni exposed to 25.0℃ decreased sharply after 20 hours. Their rest time at the bottom of experiment chamber increased, and their normal swimming and metabolic activities were disturbed. In addition, at a high water temperature of 30.0℃, S. thompsoni reached the limit of resistance and showed a sub-lethal reaction of swimming behavior, with energy consumption in the body increased and all test organisms died. In conclusion, the eco-physiological response of S. thompsoni to water temperature varied greatly depending on the fluctuation range of the exposed temperature and the exposure time. In addition, the tolerance limit of S. thompsoni to high water temperature was predicted to be 25.0-30.0℃. The maximum critical thermal that had a great influence on the survival of this species was found to be around 30.0℃.

An Evaluation of Exposure to Petroleum Based Dry Cleaning Solvent Used in Commercial Dry Cleaning Shops (석유계 솔벤트를 사용하는 세탁소 작업자의 노출평가)

  • Jeong, Jee Yeon;Yi, Gwang Yong;Lee, Byung kyu;Lee, Naroo;Kim, Bong Yeon;Kim, Kwang Jong
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.15 no.1
    • /
    • pp.19-26
    • /
    • 2005
  • In previous report, we presented that petroleum based solvents used in dry cleaning shop was almost similar to stoddard solvent defined by ACGIH and NIOSH, and the occupational exposure standard of stoddard solvent could be used in total exposure assessment of those solvents. The specific aim of the this study was to evaluate of the solvent exposure used in commercial dry cleaning shops by using occupational exposure standard of stoddard solvent. We conducted first survey of 8 self-employed dry cleaning shops and 5 factory type dry cleaning shops from July to August, and second survey of the same shops from October to November in 2002. The exposure concentration to the solvent during loading and unloading activity of vented dry cleaning machine was 489.2ppm(GM), 270.3ppm(GM), respectively, which was almost excursion limit(500ppm) of ACGIH, and exceed the ceiling limit(312ppm) of NIOSH. The time-weighted average (TWA) worker exposure to the solvent was 21.3ppm(GM) at self-employed shops, 20.7ppm(GM) at factory type shops on first survey, and 31.1ppm(GM), 33.7ppm(GM), respectively on second survey. The TWA exposure concentration of workers with spotting and cleaning machine operating job was 25.4ppm(GM), which was 2.9 times higher than the TWA exposure concentration, 8.8ppm(GM) of press workers. All TWA exposure concentrations was lower than OEL(100ppm) of stoddard solvent. We found that the most heavy exposure process at dry cleaning was loading, unloading process, and the vent of dry cleaning machine was the main emission source for workers exposure to petroleum based solvent.