• Title/Summary/Keyword: Exposed Concrete

Search Result 909, Processing Time 0.028 seconds

A Study on the Performance Evaluation Method of Waterproofing-Seal as Leakage Cracks Repairing Material using on the Underground Structure (지붕용 톱코팅재의 내구성 향상에 관한 성능 및 평가방법에 관한 기초적 연구)

  • Park, Jin-Sang;Kang, Hyo-Jin;Oh, Sang-Keun
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.05b
    • /
    • pp.517-520
    • /
    • 2006
  • The waterproofing of Building on the roof has been exposed more underground or the other part of waterproofing than environmental factor(solar heat, UV, salt, acid rain, wind, temperature, snow, rain, etc.) or physical factor. So it must be have a waterproofing performance and it has a special technique for the maintaining of concrete durability. Therefore, exposed waterproof layer has to protected from UV, solar heat, rain and the outside environment also, to endurance durability methods spread face plate topcoat material on the waterproof layer. But, actuality faceplate waterproof layer of topcoat materials are unbearable to UV, solar heat and moisture etc. and it doesn't have adhesion with waterproof layer in the middle. So it happens to crack, separating and heaving etc. Therefore, in the study, we will suggest that using of the exposed roof waterproof layer topcoat materials test method manage rooftop waterproof layer for the durability and the stability.

  • PDF

Exposed Reinforced Concrete-Filled Steel Tubular (RCFST) column-base joint with high-strength

  • Mou, Ben;Wang, Zian;Qiao, Qiyun;Zhou, Wanqiu
    • Steel and Composite Structures
    • /
    • v.44 no.1
    • /
    • pp.1-15
    • /
    • 2022
  • The weld quality has always been an important factor affecting the development of exposed CFT column-base joint. In this paper, a new type of exposed RCFST column-base joint is proposed, in which the high strength steel bars (USD 685) are set through the column and reinforced concrete foundation without any base plate and anchor bolts. Three specimens, the varying axial force ratio (0, 0.25 and 0.5), were tested under cyclic loadings. In addition, the bending moment capacity, energy dissipation capacity and deformation capacity of column-base joints were clarified. The experimental results indicated that the axial force ratio increases the stiffness and the bending moment and improves the energy dissipation capacity of column-base joints. This is because a large axial force can limit the slip between steel tubular and infilled concrete effectively. The specimens show stable hysteresis behavior.

Air-borne Chloride Content in Domestic Marine Environment (국내 해안의 비래염분량 조사결과)

  • 정해문;안태송;류종현;안성순
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2003.11a
    • /
    • pp.66-69
    • /
    • 2003
  • Chloride ingress into concrete followed by reinforcement corrosion and deterioration of concrete structures is a major problem for many structures under chloride attacks. It is necessary to investigate the environmental conditions of concrete structures exposed to chloride attacks. In this study, the air-borne chloride contents in domestic marine environment were investigated.

  • PDF

Numerical Study on Flexural Strength of Reinforced Concrete members Exposed to Fire (가열조건에 따른 철근콘크리트 부재의 휨 강도에 관한 해석적 연구)

  • 이상호;허은진
    • Journal of the Korea Concrete Institute
    • /
    • v.13 no.3
    • /
    • pp.195-205
    • /
    • 2001
  • This Paper describes a numerical method to evaluate the flexural strength of reinforced concrete members exposed to fire. An analytical method is developed for the moment-curvature relationship for the cross section which is subjected to high temperature. The method performs heat-transfer analysis for the cross sections and subsequently performs numerical analysis using the stress-strain relationships of concrete and reinforcing steel in various heat conditions. The results of the numerical studies are ; 1) the residual flexural strength exposing at high temperature is affected by the heating time, the depth of concrete cover and reinforcement ratio, 2) the residual flexural strength after exposed at high temperature is recovered of its original strength at minimum ratio of reinforcement, while members having half of maximum ratio and maximum ratio of reinforcement do not recover its original strength, 3) furthermore, the concrete may reach its maximum capacity before reinforcement yields in reinforced concrete members having maximum ratio of reinforcement.

Evaluation of Concrete Freeze and Thaw Resistance by Measuring Surface Rebound Value and Relative Dynamic Modulus of Elasticity (반발경도와 상대동탄성계수 측정에 의한 콘크리트 동결융해 성능평가 비교연구)

  • Park, Ji-Sun;Ahan, Ki-Hong;You, Young-Jun;Lee, Jong-Suk
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.9 no.4
    • /
    • pp.419-424
    • /
    • 2021
  • This study investigated the possibility of early determination of frost damage on the concrete surface by using the rebound hardness method, widely used for estimation the compressive strength of concrete on the site. For this purpose, the surface damage of concrete was compared by measuring the rebound hardness and the relative dynamic modulus of the concrete for the multi-sided and single sided concrete surface exposed to freeze and thaw condition. Compared to the resonance vibration method, the rebound hardness method was able to show the frost damage 150 cycles quicker for the single-sided exposed concrete specimen and 50 cycles quicker for the multi-sided exposed concrete specimen. Therefore, it is considered that the rebound hardness method can determine the concrete surface damage more quickly than that of the resonance vibration method.

Estimation of Concrete Cover Failure Time Considering the Corrosion Rate in Reinforced Concrete Structures (철근 부식속도 예측식을 이용한 철근 피복 파괴 시간 추정)

  • Jang, Bong-Seok
    • Journal of the Korea Concrete Institute
    • /
    • v.18 no.2 s.92
    • /
    • pp.233-238
    • /
    • 2006
  • In lifetime estimation, the FEM analysis method is proposed for predicting corrosion failure time of concrete structures exposed to sea-water. This study shows that the corrosion rate of rebar in artificial pore solution can be transferred to the corrosion rate of rebar in concrete using the relationship between pore volume and concrete volume by Jennings' model. And this study considered the pitting corrosion effects of reinforcement bar on corrosion failure analysis, rebar size to cover depth and nonlinear crack analysis. These analysis results have good accordance with the experimental results of Williamson's work. This methodology can be applied to lifetime prediction procedure of reinforced concrete structures and also gives more reasonable results of concrete cover failure time estimation of reinforced concrete structures exposed to sea-water.

A Study on the Estimation of Steel Corrosion in Concrete Exposed under the Environment of Seawater (해양환경하에 방치한 콘크리트중의 철근의 부식 추정에 대한 연구)

  • 문한영;김성수;류재석
    • Magazine of the Korea Concrete Institute
    • /
    • v.6 no.2
    • /
    • pp.129-137
    • /
    • 1994
  • This study was performed for the purpose of obtaining the fundamental data to establish the criterion of concrete deterioration and presuming steel corrosion of concrete structures under the environment of seawater. Steel embedded concrete specimens were exposed in seawater for 1year. The soluble chloride content in concrete, corrosion potential and steel corrosion were considered. The results show that soluble chloride content in concrete was decreased with lower water-cement ratio and with mineral admixtures. Half-cell potential is reduced with steel corrosion. Corrosion area ratio is correlative with half-cell potential.