• 제목/요약/키워드: Experimental verification

검색결과 1,663건 처리시간 0.027초

Dynamic Elastica 이론을 통한 유연매체의 거동해석 및 실험 (The Simulation and Experiment of Flexible Media using Dynamic Elastics)

  • 홍성권;지중근;장용훈;박노철;박영필
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 추계학술대회논문집
    • /
    • pp.569-572
    • /
    • 2005
  • In many machines handling lightweight and flexible media, such as automated teller machines(ATM) and printers etc., the media must transit an open space. In the paper feeding mechanism, it is important to feed the sheet without jamming under any conditions. To avoid sheet jamming, first we need to predict the behavior of the sheet exactly. The nonlinear theory of the dynamic elastica has often been used to a nonlinear dynamic deflection model. In this paper, the governing equation is derived and simulated by the finite difference method. The analysis has to include aerodynamic effect for more exact behavior analysis. For verification of the numerical simulation, the experiments were performed using high-speed camera and feeding mechanism. The experimental results show good agreement with the numerical simulations.

  • PDF

고차통계를 이용한 충격/불량신호 탐지 (BLIND IDENTIFICATION OF IMPACTING SIGNAL USING HIGHER ORDER STATISTICS)

  • Seo, Jong-Soo;J.K. Hammond
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2001년도 추계학술대회논문집 II
    • /
    • pp.1044-1049
    • /
    • 2001
  • Classical deconvolution methods for source identification following linear filtering can only be used if the transfer function of the system is known. For many practical situations, however, this information is not accessible and/or is time varying. The problem addressed here is that of reconstruction of the original input from only the measured signal. This is known as 'blind deconvolution'. By using Higher Order Statistics (HOS), the restoration of the input signal is established through the maximisation of higher order moments (cumulants) with respect to the characteristics of the signals concerned. This restoration is achieved by constructing an inverse filter considering the choice of the initial inverse filter type. As a practical application, an experimental verification is carried out for the restoration of our impacting signal arising in the response of a cantilever beam with an end stop when randomly excited.

  • PDF

축류송풍기 부착형 공냉식 열교환기의 진동저감 (Vibration Reduction of an Air Cooled Heat Exchanger with Axial Flow Fan)

  • 정구충;최연선
    • 한국소음진동공학회논문집
    • /
    • 제11권6호
    • /
    • pp.163-168
    • /
    • 2001
  • Vibration problems occurred in an air cooled heat exchanger with axial flow fan for a petrochemical plant were investigated. Experimental field test and theoretical verification were performed. To find the main cause of the high vibration of the fan at the air inlet of the axial fan, the frequency spectrum was measured. The natural frequency of the driving support of the heat exchanger was numerically calculated. Both of the measured and the natural frequency were approximately equal to the blade passing frequency. Because it was difficult to modify the structure of the driving support during the normal operation of the plant, the blade number of the fan was increased, which greatly reduced the vibration level of the heat exchanger.

  • PDF

2축 짐벌 안정계 동특성 고찰을 통한 해석 모델링 검증에 관한 연구 (Study for verification of Analysis modeling with investigating dynamic characteristic about 2 axies gimbals system)

  • 김만달;이용덕;김성국
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 추계학술대회논문집
    • /
    • pp.180-183
    • /
    • 2005
  • 2 axis gimbals systems are extensively used in various tracking devices for attaining the system's objective. Designers are sometimes passing over the dynamic characteristics of system in vibrating condition In this paper, 2 axis gimbals systems including interface elements is modeled with finite elements. To verify this model, the finite element model is refined by using the experimental model data. The refined model is simulated with I-DEAS and MSC.NATRAN's FRF(Frequency response Function) and RRA(Random vibration Response Analysis) function to get dynamic characteristics of 2 axis gimbals system.

  • PDF

축류송풍기 부착형 공냉식 열교환기의 진동 저감 (Vibration Reduction of an Air Cooled Heat Exchanger with Axial Flow Fan)

  • 정구충;최연선
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2000년도 추계학술대회논문집
    • /
    • pp.75-81
    • /
    • 2000
  • Vibration problems induced by an air cooled heat exchanger with axial flow fan were investigated during the operation of a petrochemical plant. Two different studies were done; one was experimental field test and the other was theoretical verification. To find main cause of the blade passing frequency of the fan after installing additional blockage board at the air inlet of the axial fan, the frequency spectrum was measured. The vibrations of the blade passing frequency became higher. The natural frequency of driving support of the heat exchanger was theoretically calculated. It was approximately equal to the blade passing frequency. During the normal operation of the plant, it was impossible to modify the structure of the driving support. Instead, the blade number was increased to reduce vibration level. It increased the ratio of the forcing frequency to the natural frequency of the driving support over the resonance region.

  • PDF

왕복동형 압축기의 낙하충격 시뮬레이션 및 실험적 검증 (Drop/Impact Simulation and Experimental Verification of a Reciprocating Compressor Body)

  • 김태종;김문생;구자함
    • 한국소음진동공학회논문집
    • /
    • 제17권6호
    • /
    • pp.484-490
    • /
    • 2007
  • A reciprocating compressor used in domestic refrigerators can be subjected to many different forms of shock. These shocks are usually experienced during transporting the products from a manufacturer to customers. The hermetic structure of this kind of compressor makes it difficult to conduct drop tests for identifying the failure mechanism and their drop behaviors. The drop/impact simulation for a reciprocating compressor has been carried out with the explicit code LS-DYNA and its validation has been experimentally verified. Simulation results are in good agreement with those of drop test. The present method of drop/impact simulation provides an efficient and powerful solution to improve the design quality and reduce the design period.

육골 폐기물 재활용을 위한 파쇄 및 포장 시스템의 개발 (Development of Crushing and Packing Systems for Recycling in Wasted Meat & Bone)

  • 백일현
    • 한국기계기술학회지
    • /
    • 제20권6호
    • /
    • pp.936-940
    • /
    • 2018
  • Wasted meat & bone has generated as byproducts in the slaughtering process of livestock and also faced with demands for its recycling and environmental protection. Many studies have been conducted to recycle byproducts and carried out mainly on the crushing of bones and the vacuum packing technology of products. In this study, the crushing unit, transporting unit, separated unit and packing unit have designed for development of the crushing and packing systems. Also, to confirm the performance of this system, the experimental verification were carried out the working noise and packing weight.

Spatial and temporal distribution of driving rain on a low-rise building

  • Blocken, Bert;Carmeliet, Jan
    • Wind and Structures
    • /
    • 제5권5호
    • /
    • pp.441-462
    • /
    • 2002
  • This paper presents a practical numerical method to determine both the spatial and temporal distribution of driving rain on buildings. It is based on an existing numerical simulation technique and uses the building geometry and climatic data at the building site as input. The method is applied to determine the 3D spatial and temporal distribution of wind-driven rain on the facade a low-rise building of complex geometry. Distinct wetting patterns are found. The important causes giving rise to these particular patterns are identified : (1) sweeping of raindrops towards vertical building edges, (2) sweeping of raindrops towards top edges, (3) shelter effect by various roof overhang configurations. The comparison of the numerical results with full-scale measurements in both space and time for a number of on site recorded rain events shows the numerical method to yield accurate results.

Dynamic analysis of a cable-stayed bridge using continuous formulation of 1-D linear member

  • Yu, Chih-Peng;Cheng, Chia-Chi
    • Earthquakes and Structures
    • /
    • 제3권3_4호
    • /
    • pp.271-295
    • /
    • 2012
  • This paper presents the solution scheme of using the continuous formulation of 1-D linear member for the dynamic analysis of structures consisting of axially loaded members. The context describes specific applications of such scheme to the verification of experimental data obtained from field test of bridges carried out by a microwave interferometer system and velocimeters. Attention is focused on analysis outlines that may be applicable to in-situ assessment for cable-stayed bridges. The derivation of the dynamic stiffness matrix of a prismatic member with distributed properties is briefly reviewed. A back calculation formula using frequencies of two arbitrary modes of vibration is next proposed to compute the tension force in cables. Derivation of the proposed formula is based on the formulation of an axially loaded flexural member. The applications of the formulation and the proposed formula are illustrated with a series of realistic examples.

Evaluation of Condensation Heat Transfer Correlations for Microfin Tubes

  • Han, Dong-Hyouck;Lee, Kyu-Jung
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제15권4호
    • /
    • pp.163-168
    • /
    • 2007
  • The feature of six existing condensation heat transfer correlations for microfin tubes were evaluated with the consideration of vapor quality, mass flux, geometries, and various refrigerants. The Kosky and Staub [15] and the Jaster and Kosky [16] correlations for smooth tube were used for the evaluation of the heat transfer enhancement factor (EF). For the prediction of zeotropic mixtures, most correlations show discrepancy with previous measurements. The Yu and Koyama [4] and the Shikazono et al. [8] correlations do not consider spiral angle effect. The Han and Lee [10] correlation shows fin height growth deteriorates heat transfer. Experimental verification to develop reliable condensation heat transfer correlation for microfin tubes is still needed with the consideration of geometrical effects and working conditions.