• Title/Summary/Keyword: Experimental instrument

Search Result 470, Processing Time 0.029 seconds

Comparative Evaluation of Albedo Distribution according to Administrative Boundary Using MODIS Products (MODIS 영상을 이용한 행정구역별 알베도 분포 비교평가)

  • Kim, Ki-Youl;Um, Jung-Sup
    • Journal of Environmental Impact Assessment
    • /
    • v.21 no.2
    • /
    • pp.265-277
    • /
    • 2012
  • This paper is primarily intended to present quantitative evidences for land surface albedo difference among seven metropolitan cites in South Korea. An empirical study for experimental sites was conducted to confirm how a standard MODerate Resolution Imaging Spectroradiometer (MODIS) instrument offers the viable method of measuring and comparing the regional heterogeneity of albedo among administrative districts. The metropolitan cities like Seoul located in dense building environment do result in much lower albedo than those exposed in much more sub-urban surface (e.g KwangJoo). These experimental results indicate that an urban surface such as building and road is a crucial explanatory variable for lower albedo. It is confirmed that the urban surface such as building and road could be employed as a proxy of the lower albedo burden in the metropolitan area. It is anticipated that this research output could be used as a valuable reference to confirm the potential of introducing the new concept of "administrative districts specific albedo management" to support more scientific and objective decision-making in the process of GHG (Greenhouse Gas) reduction project.

Comparative Analysis of Dynamic Moisture Movement Testers

  • Lee, Duck-Weon;Shim, Woo-Sub;Lim, Ho-Sun
    • Journal of Fashion Business
    • /
    • v.15 no.6
    • /
    • pp.40-55
    • /
    • 2011
  • The purpose of this research is to review testing principle, testing design and experimental results of the four dynamic moisture movement testers. The research analyzes Moisture Manager Tester (MMT), Alambeta Instrument, Dynamic Surface Moisture Movement Tester, and Gravimetric Absorbent Testing Method based on American Society for Testing and Material (ASTM) E 96 which is an international standard testing method. Although many of researches use ASTM E 96 to measure moisture movement on a fabric, it has several weaknesses, such as long experimental time and a physical change of sample by a holder of the frame. Hence, lots of researchers have studied and developed the new measurement systems measuring moisture management on a fabric or garment and ultimately mimic heat energy and perspiration created by the human body. These moisture management systems use a variety of parameters, such as electricity, color, and sensor to measure their movement in the fabric. Through comparison with the existing tester (ASTM E 96), the research recognizes the strength and weakness in the dynamic moisture movement testers.

OCI and ROCSAT-1 Development, Operations, and Applications

  • Chen, Paul;Lee, L.S.;Lin, Shin-Fa
    • Korean Journal of Remote Sensing
    • /
    • v.15 no.4
    • /
    • pp.367-375
    • /
    • 1999
  • This paper describes the development, operations, and applications of ROCSAT-l and its Ocean Color Imager (OCI) remote-sensing payload. It is the first satellite program of NSPO. The satellite was successfully launched by Lockheed Martin's Athena on January 26, 1999 from Cape Canaveral, Florida. ROCSAT-l is a Low Earth Orbit (LEO) experimental satellite. Its circular orbit has an altitude of 600km and an inclination angle of 35 degrees. The satellite is designed to carry out scientific research missions, including ocean color imaging, experiments on ionospheric plasma and electrodynamics, and experiments using Ka-band (20∼30GHz) communication payloads. The OCI payload is utilized to observe the ocean color in 7 bands (including one redundant band) of Visible and Near-Infrared (434nm∼889nm) range with the resolution of 800m at nadir and the swath of 702km. It employs high performance telecentric optics, push-broom scanning method using Charge Coupled Devices (CCD) and large-scale integrated circuit chips. The water leaving radiance is estimated from the total inputs to the OCI, including the atmospheric scattering. The post-process estimates the water leaving radiance and generates different end products. The OCI has taken images since February 1999 after completing the early orbit checkout. Analyses have been performed to evaluate the performances of the instrument in orbit and to compare them with the pre-launch test results. This paper also briefly describes the ROCSAT-l mission operations. The spacecraft operating modes and ROCSAT Ground Segment operations are delineated, and the overall initial operations of ROCSAT-l are summarized.

Assessment of Instrument Efficiency in Detecting Airborne Virus (공기 중 바이러스 포집 장비의 효율성 평가)

  • Ha, Tae-Hwan;Lee, In-Bok;Kwon, Kyeong-Seok;Lee, Sung-Bok;Song, Sang-Hyeon;Bitog, Jessie. P.;Yoon, Soon-Seek
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.54 no.1
    • /
    • pp.63-72
    • /
    • 2012
  • In livestock industry, damage caused by the epidemic diseases such as Foot-and-Mouth Disease (FMD), Highly-Pathogenic-Avian-Influenza (HPAI) and Porcine-Reproductive-and-Respiratory-Syndrome (PRRS) was very serious. The financial loss incurred from FMD alone which occurred on Nov. 2011 in Korea was estimated at 3 billion won, 23 % of annual livestock industry production. The livestock industry in Korea has greater risk of disease infection because of high density production, etc. Investigating the spread of livestock diseases should consider both direct and indirect contact as well as other various factors including airborne. Airborne infection of livestock disease was first hypothesised in the early 1900s, however, field experimental studies are still limited. Furthermore, no protocol is available in detecting airborne viruses in the field. In this study, effective virus samplers were investigated by comparative analysis of the type of samplers used detect to airborne virus. Laboratory experiments were conducted to compare virus samplers such as Bio-sampler, Dust-sampler, Compact-Cascade-Impactor (CCI) and Microflow in detecting PRRSV. Samples were analyzed by Reverse-Transcription PCR to assess the efficiency of the instrument in detecting the airborne virus. First, samples were classified into five levels according to light intensity of gel images and then the classified results were normalized. In every case, Bio-sampler and Dust-sampler were comparable with each other and have shown to be more effective than CCI and Microflow samplers.

DESIGN AND REALIZATION OF UNIVERSAL DATA INTERFACE SIMULATOR FOR INTERNATIONAL SPACE STATION (국제우주정거장 범용 데이터인터페이스 시뮬레이터 설계 및 검증)

  • Kim, Jong-Woo;Seo, Suk-bae;Kim, Kyung-Tae
    • Journal of Astronomy and Space Sciences
    • /
    • v.22 no.1
    • /
    • pp.59-68
    • /
    • 2005
  • KARI studied data interface of Space Applications for developing Space Experimental Instrument in International Space Station, designed, and manufactured the UDIS (International Space Station Universal Data Interface simulator) according to requirements of the data interface. This paper explains the design and implementation of UDIS for space application. UDIS is the instrument which simulate to interface the data from ISS to experiment module, payload and habitation module and use the development of a experiment system in the space. This simulator will be used to the GSE (Ground Support Equipment) for test of experiment system. By realization of the simulator, we ensure data interface skills for a manned-space data communication system.

Learning Styles and Preferred Nursing Specialties of Nursing Students (교육과정별 간호학생의 학습유형과 간호분야 선호에 관한 일 연구)

  • Lee, Myung-Ok
    • The Journal of Korean Academic Society of Nursing Education
    • /
    • v.6 no.1
    • /
    • pp.64-76
    • /
    • 2000
  • The purpose of this study is to identify the difference in learning styles, learning stages, and preferred nursing specialties between two groups of nursing programs, regular BSN and RN-BSN. The survey instrument was a simplified version of the Kolb's Learning-Style Instrument which was developed by the researcher, a self- reported learning style questionnaire with twelve questions related to the four learning stages. The sample of the study was the 218 nursing students in a university in Korea which consisted of 58 junior and 67 senior students in the regular BSN program, and 58 junior and 35 senior students in the RN-BSN program. Main findings of the study were as the following. 1) Over all, the major learning style was either the diverger or the accomodator; the most preferred learning stage was the concrete experience and the leastly preferred learning stage was the abstractive conceptualization learning stage; and the most preferred nursing specialty in the future was the clinical nursing. 2) Students in the BSN program preferred four learning stages with rather equal proportion, whereas the students in the RN-BSN program preferred the concrete experience learning stage as high as 60.3% and the abstractive conceptualization learning stage as low as 9.5%. 3)For the future career, the junior students of both programs preferred clinical and educational nursing areas, and the senior students of both programs preferred clinical and research areas. The main reason of the difference seemed to result from the different courses such as Health Education or Teaching Method for the juniors and the Nursing Research for the seniors of both groups. Because the sample of the study was limited to a university, it is difficult to generalize the study results for the entire nursing students in Korea. Continuous studies with larger numbers of nursing students and nurse educators, and experimental studies measuring the effects of new curricula are needed for the future.

  • PDF

Role of Arbitrary Intensity Profile Laser Beam in Trapping of RBC for Phase-imaging

  • Kumar, Ranjeet;Srivastava, Vishal;Mehta, Dalip Singh;Shakher, Chandra
    • Journal of the Optical Society of Korea
    • /
    • v.20 no.1
    • /
    • pp.78-87
    • /
    • 2016
  • Red blood cells (RBCs) are customarily adhered to a bio-functionalised substrate to make them stationary in interferometric phase-imaging modalities. This can make them susceptible to receive alterations in innate morphology due to their own weight. Optical tweezers (OTs) often driven by Gaussian profile of a laser beam is an alternative modality to overcome contact-induced perturbation but at the same time a steeply focused laser beam might cause photo-damage. In order to address both the photo-damage and substrate adherence induced perturbations, we were motivated to stabilize the RBC in OTs by utilizing a laser beam of ‘arbitrary intensity profile’ generated by a source having cavity imperfections per se. Thus the immobilized RBC was investigated for phase-imaging with sinusoidal interferograms generated by a compact and robust Michelson interferometer which was designed from a cubic beam splitter having one surface coated with reflective material and another adjacent coplanar surface aligned against a mirror. Reflected interferograms from bilayers membrane of a trapped RBC were recorded and analyzed. Our phase-imaging set-up is limited to work in reflection configuration only because of the availability of an upright microscope. Due to RBC’s membrane being poorly reflective for visible wavelengths, quantitative information in the signal is weak and therefore, the quality of experimental results is limited in comparison to results obtained in transmission mode by various holographic techniques reported elsewhere.

Gate Locations Optimization of an Automotive Instrument Panel for Minimizing Cavity Pressure (금형 내부 압력 최소화를 위한 자동차 인스트루먼트 패널의 게이트 위치 최적화)

  • Cho, Sung-Bin;Park, Chang-Hyun;Pyo, Byung-Gi;Cho, Dong-Hoon
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.29 no.6
    • /
    • pp.648-653
    • /
    • 2012
  • Cavity pressure, an important factor in injection molding process, should be minimized to enhance injection molding quality. In this study, we decided the locations of valve gates to minimize the maximum cavity pressure. To solve this problem, we integrated MAPS-3D (Mold Analysis and Plastic Solution-3Dimension), a commercial injection molding analysis CAE tool, using the file parsing method of PIAnO (Process Integration, Automation and Optimization) as a commercial process integration and design optimization tool. In order to reduce the computational time for obtaining the optimal design solution, we performed an approximate optimization using a meta-model that replaced expensive computer simulations. To generate the meta-model, computer simulations were performed at the design points selected using the optimal Latin hypercube design as an experimental design. Then, we used micro genetic algorithm equipped in PIAnO to obtain the optimal design solution. Using the proposed design approach, the maximum cavity pressure was reduced by 17.3% compared to the initial one, which clearly showed the validity of the proposed design approach.

Velocity Measurement of Stream Water Surface Using Microwave (전자파를 이용한 하천수 표면유속 측정)

  • Lee, Sang-Ho;Lee, Han-Gu;Kim, U-Gu
    • Water for future
    • /
    • v.28 no.6
    • /
    • pp.183-191
    • /
    • 1995
  • Applying microwave, a velocity measurement system has been developed in order to measure the velocity of stream water surface. It's main purpose is the measurement for high velocity of flood water. It is under the developing stage of experimental measurement system. The microwave surface velocity meter uses Doppler effects of microwave. It consists of a radio frequency(RF) part and that of signal processing. Thr RF part has the function of microwave oscillation, reception of reflected wave, and determination of Doppler frequency, etc. Signal processing designates amplification, fast Fourier transform, etx. Various measuring experiments were performed at bridges and a spillway of Taechong re-regulation dam with the microwave velocity meter. Verification test was also made through water tank of ship model test at Research Institute of Ships and Ocean Engineering. It shows 4% error inherent in A/D converter and additional several percentage errors from measurement circumstance. The measuring ranges are from 0.5 to 3.5 m/s. The result shows good linear relationship between carriage velocity and measured velocity, thus proves usefulness as a measuring instrument for flood water velocity. The instrument requires overall re-engineering procedure and number of data should be accumulated and analyzed to treat wind effects and random fluctuations of water surface.

  • PDF

Electrical and Mechanical Properties of Indium-tin-oxide Films Deposited on Polymer Substrate Using Organic Buffer Layer

  • Han, Jeong-In;Lee, Chan-Jae;Rark, Sung-Kyu;Kim, Won-Keun;Kwak, Min-GI
    • Journal of Information Display
    • /
    • v.2 no.2
    • /
    • pp.52-60
    • /
    • 2001
  • The electrical and mechanical properties in indium-tin-oxide films deposited on polymer substrate were examined. The materials of substrates were polyethersulfone (PES) which have gas barrier layer and anti-glare coating for plastic-based devices. The experiments were performed by rf-magnetron sputtering using a special instrument and buffer layers. Therefore, we obtained a very flat polymer substrate deposited ITO film and investigated the effects of buffer layers, and the instrument. Moreover, the influences of an oxygen partial pressure and post-deposition annealing in ITO films deposited on polymer substrates were clarified. X-ray diffraction observation, measurement of electrical property, and optical microscope observation were performed for the investigation of micro-structure and electro-mechanical properties, and they indicated that as-deposited ITO thin films are amorphous and become quasi-crystalline after adjusting oxygen partial pressure and thermal annealing above $180^{\circ}C$. As a result, we obtained 20-25 ${\Omega}/sq$ of ITO films with good transmittance (above 80 %) of oxygen contents with under 0.2 % and vacuum annealing. Furthermore, using organic buffer layer, we obtained ITO films which have a rather high electrical resistance (40-45 ${\Omega}/sq$) but have improved optical (more than 85 %) and mechanical characteristics compared to the counterparts. Consequently, a prototype reflective color plastic film LCD was fabricated using the PES polymer substrates to confirm whether the ITO films could be realized in accordance with our experimental results.

  • PDF