• Title/Summary/Keyword: Experimental Apparatus

Search Result 1,175, Processing Time 0.04 seconds

Experimental Study of the Anastomosis with Suture vs Non-suture Techinique (미세 혈관 접합술에서 봉합적 수기와 비봉합적 수기의 실험적 비교 연구)

  • Chung, Duke-Whan;Han, Chung-Soo;Yoo, Myung-Chul;Nam, Gi-Un;Sun, Seung-Deok
    • Archives of Reconstructive Microsurgery
    • /
    • v.3 no.1
    • /
    • pp.45-53
    • /
    • 1994
  • Suture microvascular anastomosis is time-consuming and tedious and demands long and continuous training. Techinique of anastomosis of microvessel was presented interrupted suture and continuous suture. Recently the unilink instrument system is created as a fast and simple method to achieve high patency rates without long and continuous training in the anastomosis of small vessels. The author experimentally studied the femoral artery of 20 mice(0.5-1.0mm, av. 0.7mm), the femoral vein of 20 mice(0.8-1.6mm, av. 1.2mm) after anastomosis with interrupted suture in 20 cases and continuous sutre in 20 cases. For the unilink apparatus we used the carotid arteries of 15 cases in 14 rabbits(1.0-1.6mm, av. 1.3mm) and facial veins of 12 cases in 14 rabbits(0.9mm-2.2mm, av. 1.5mm). A total of 27 arterial and venous anastomoses were performed. We examined the postoperative patency at immediate, 2 weeks, and 8 weeks. The results were as followings, 1. In the arterial anastomosis the rate of patency was 90%(18/20) in interrupted suture, 90%(18/20) in continuous suture and 93%(13/15) in unilink apparatus. In the venous anastomosis the rate of patency was 90%(18/20) in interrupted suture, 80%(16/20) in continuous suture and 100%(9/9) in unilink apparatus. 2. The mean time for completion of the arterial anastomosis were 12.2 minutes in interrupted suture group, 10.3 minutes in continouous suture group and 8.5 minutes in unillnk apparatus group. The mean time for completion of the venous anastomosis were 13.6 minutes in interrupted suture group, 11.0 minutes in continuous suture group and 6.2 minutes in unilink apparatus group. 3. At the histological examination of suture group, hyperplastic reaction of middle layer and subintimal hyperplasia were observed. In unilink apparatus group, the endothelium layer was continued and the thickness of vessel wall was decreased due to moderate atrophy of the media and mild degree of nonspecific chronic inflammation were seen around the unilink apparatus. 4. No significants was noticied in foreign body reaction among the interrupted, continuous and unilink apparatus group. 5. A case of the arterial anastomosis was released with acting out at 15 minutes after operation. 6. The important factors in the technical problems were accurate apposition of the cut vessel edges in suture group and the proper selection of the ring size and optimal fitting between two rings in unilink apparatus group. Even though the outer diamater of vessel in suture group was different from that in unilink apparatus group the unilink method provides a very safe, fast, and simple way to perform microvascular anastomoses especially in anastomosis of vein. But howerver suture was needed in vessels below 1 mm outer diamater. In that situation continuous suture was benefit than the interrupted suture in operation time.

  • PDF

Temperature Rise Prediction of GIS Bus Bar Considering Thermal Flow (열유동을 고려한 GIS 모선의 온도상승 예측)

  • Kim, Joong-Kyoung;Oh, Yeon-Ho;Lee, Ji-Yeon;Hahn, Sung-Chin
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.4
    • /
    • pp.742-747
    • /
    • 2009
  • Many works on the temperature distribution of power apparatus have usually done by coupled magneto-thermal analysis. Such a method can not consider the internal gas or oil flow in the power apparatus such as gas insulated switchgear, GIS bus bar, and power transformer. Moreover it can not show the internal temperature distribution of the power apparatus exactly. This paper proposes a coupled magneto-thermal-flow analysis considering Navier-Stokes equations. The convection heat transfer coefficient is calculated analytically by applying Nusselt number for natural convection and is applied to the boundary condition of proposed method. Temperature distribution of the GIS bus bar model considering thermal flow is obtained by the proposed method and shows good agreement with the experimental data.

Design and Fabrication of High Potential Cenerator for Cathod-ray Apparatus (음극선 발생기를 위한 고전압 발생 장치의 설계 및 제작)

  • 주동만;민경일;황재효
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.2 no.2
    • /
    • pp.11-18
    • /
    • 2001
  • The design method of high potential generator of diagnostic X-ray apparatus by using inverter is presented. For the high potential generator, a line filter, a rectifier, a Pulse width modulation control, bridge drive, a high potential transformer and a high potential rectifier circuit were adopted. The high potential generator with switching frequency to be 40 KHz is fabricated by using design method presented in this method. The experimental results are as followings; variable volts of 0∼620 V and variable currents 50∼500 mA.

  • PDF

Studies on the Comparative Assay for the Alcohol Contents by the Determination of Alcohol Number and Diffusion Method (알코올수측정법(數測定法)에 의(依)한 알코올수(數)와 확산분석법(擴散分析法)에 의(依)한 에탄올 측정량(測定量)과의 비교연구(比較硏究))

  • Park, Joung-Hoon
    • Journal of Pharmaceutical Investigation
    • /
    • v.1 no.1
    • /
    • pp.53-57
    • /
    • 1971
  • A Diffusion analysis method is described for the determination of alcohol content in tinctures and spirits and then, the comparison test of the official alcohol number test with the diffusion analysis method has hen carried out. Throughout this experiments, a transformed Widmark apparatus is used. It is found that the diffusion analysis method using the transformed Widmark apparatus is very simple and occapy a small space. One of the most convenient fact is many sample can be analyzed at a time with this apparatus. Experimental data indicate that 95% of alcohol content obtained by the official alcohol number test is found in the diffusion analysis.

  • PDF

Electrical Breakdown Characteristics of LN2 under Simulated Quenching Conditions for Application of HTS Apparatus (고온초전도 기기응용을 위한 모의 \ulcorner치 환경에서 액체질소의 절연파괴 특성)

  • 백승명;정종만;김상현
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.15 no.11
    • /
    • pp.985-990
    • /
    • 2002
  • The electrical breakdown characteristics of liquid nitrogen(LN$\sub$2/) were studied under simulated quenching conditions for application of HTS apparatus. The experimental results for various quenching condition revealed that the breakdown voltage of LN$\sub$2/ with bubble flow velocity and gap spacing. In the case, breakdown voltage decreases gradually with the bubble velocity. When it is bubble velocity from 0 to 1 $\ell$ /min, breakdown voltage rapidly decreases but decreases from 2 $\ell$/min to 10 $\ell$/min slowly. The breakdown voltage for vertical electrode arrangement is higher than that for horizontal electrode arrangement. Also, it did a electric field and potential distribution interpreting at the liquid nitrogen when the bubble existed. The plots of equipotential lines for three cases are also shown.

An Experimental Study to Reduce the Noise Level of Sheet Feeding Apparatus for Digital MFP(Multi-Functional Product) (디지털 복합기용 용지이송기구의 소음저감을 위한 실험적 연구)

  • Cho, Mun-Son
    • Proceedings of the KSME Conference
    • /
    • 2001.11a
    • /
    • pp.579-583
    • /
    • 2001
  • Cause of noise/vibration for the sheet feeding apparatus of digital MFP is investigated by analyzing the measured sound pressure and the strategy for reducing the noise level is suggested. Factors related to the noise/vibration are found by loading test and the measurement of the noise by assembling the components. By checking the center distance between gears and the boss height, precision of assembly is identified as a main factor of noise. From the result of analysis, it can be concluded that the noise level of sheet feeding apparatus can be reduced by maintaining the distance between gears and the precision of assembly adequately.

  • PDF

A Study of Wall Shape Design for Cascade Experiment (케스케이드 실험을 위한 벽면형상 설계에 관한 연구)

  • Cho, Chong-Hyun;Cho, Bong-Soo;Kim, Chae-Sil;Cho, Soo-Yong
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2008.03b
    • /
    • pp.148-151
    • /
    • 2008
  • In a double-passage cascade apparatus, only two blades are installed in order to increase the accuracy of experimental result by applying bigger blade than the size of multi-blades on the same apparatus. However, this causes difficulties to make correct periodic condition. In this study, sidewalls are designed to meet periodic condition without removing the operating fluid or adjusting tail boards. Surface Mach number on the blade surface is applied to a responsible variable, and 12 design variables which are related with sidewall profile control are selected. A gradient based optimization is adopted for wall design and CFX-11 is used for the internal flow computation. The computed result shows that it could obtain the same flow structure by modifying only the sidewalls of the double-passage cascade apparatus.

  • PDF

Design of a Simultaneous Control System of Position and Force with a Pneumatic Cylinder Driving Apparatus (공기압 실린더 구동 장치를 이용한 힘과 위치 동시 제어계 설계)

  • Jang, Ji-Seong
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.1614-1619
    • /
    • 2003
  • In this study, position and force simultaneous trajectory tracking control system with pneumatic cylinder driving apparatus is proposed. The pneumatic cylinder driving apparatus that consists of two pneumatic cylinders constrained in series and two proportional flow control valves offers a considerable advantage as to non-interaction of the actuators because of the low stiffness of the pneumatic cylinders. The controller applied to the driving system is composed of a non-interaction controller to compensate for interaction of two cylinders and a disturbance observer to reduce the effect of model discrepancy of the driving system in the low frequency range that cannot be suppressed by the non-interaction controller. The experimental results with the proposed control system show that the interacting effects of two cylinders are eliminated remarkably and the proposed control system tracks the given position and force trajectories accurately.

  • PDF

The Experimental Consideration for Extermination of a Rice Weevil in Grain by Dielectric Heating Apparatus (유전가열장치에 의한 곡물 바구미 구제의 실험적 고찰)

  • Han, K.H.;Kim, T.J.;Joe, K.Y.;Lee, H.W.;Baek, S.H.
    • Proceedings of the KIEE Conference
    • /
    • 2002.11d
    • /
    • pp.257-259
    • /
    • 2002
  • With development of Circuit technology, accuracy of dielectric or induction heating apparatus was developed. This study aims at realization of food insecticidal apparatus using dielectric heating. Equipment to measure grain's permittivity or vermin's permittivity and expectation for heating temperature by computer simulation is necessary for construction of the system. And the effect of extermination of vermin for food was confirmed by experiment using the system.

  • PDF

Position and Force Simultaneous Trajectory Tracking Control with a Pneumatic Cylinder Driving System (공기압 실린더를 이용한 힘과 위치 동시 궤적 추적 제어)

  • Cho, M.S.;Jang, J.S.
    • Journal of Power System Engineering
    • /
    • v.7 no.3
    • /
    • pp.40-47
    • /
    • 2003
  • In this study, position and force simultaneous trajectory tracking control apparatus with pneumatic cylinder driving system is proposed. The pneumatic cylinder driving system that consists of two pneumatic cylinders constrained in series and two proportional flow control valves offers a considerable advantage as to non-interaction of the actuators because of the low stiffness of the pneumatic actuators. The controller applied to the driving system is composed of a non-interaction controller to compensate for interaction of two cylinders and a disturbance observer to reduce the effect of model discrepancy of the driving system in the low frequency range that cannot be suppressed by the non-interaction controller. The experimental results with the proposed control apparatus show that the interacting effects of two cylinders are eliminated remarkably and the proposed control apparatus tracks the given position and force trajectory accurately.

  • PDF