• Title/Summary/Keyword: Expandable

Search Result 322, Processing Time 0.028 seconds

Flame Retardancy and Physical Properties of Polyurethane Foam with Expandable Graphite (팽창 흑연을 포함한 폴리우레탄 폼의 난연 및 물성 변화 연구)

  • Bae, Sung-Jun;Park, Ji-Hyeon;Go, Jae-Wang;Choi, Pil-Jun;Lee, Jae-Yeon;Sur, Suk-Hun
    • Journal of Adhesion and Interface
    • /
    • v.20 no.3
    • /
    • pp.96-101
    • /
    • 2019
  • In this study, the flame retardant and physical properties of the expandable graphite/polyurethane foam composites were considered by the addition of expandable graphite. The tensile strength of expandable graphite/polyurethane foam composites decreased with the content of the expandable graphite and the analysis of cell shape by SEM has shown that as the expandable graphite content increases, the cell becomes uneven and collapses. As the results of the compressive strength, density and air permeability tests, it was found that density and as the content of the expandable graphite increased, the compressive strength of the composites increased but air permeability decreased. When the amount of expandable graphite was added at 10 phr or higher, the foam has excellent flame retardation performance. Analysis of the degree of diffraction by X-ray diffraction (XRD) showed that as the content of the expandable graphite increased, the crystal peak of the graphite appeared near $2{\theta}=26^{\circ}$.

Breast Augmentation using Expandable Implants (확장성(더블루멘) 보형물을 이용한 유방확대술)

  • Sim, Hyung Bo;Nam, Sang Jae;Yoon, Sang Yup
    • Archives of Plastic Surgery
    • /
    • v.32 no.4
    • /
    • pp.416-420
    • /
    • 2005
  • Ideal results of augmentation mammaplasty consist of symmetry, natural shape, soft feeling and inconspicuous scar. In addition, patient's preferences about size and shape should be included. Static implants could not perfectly satisfy patients' desires for size and shape, but expandable implants enable to change the volume after the operation. From September 2001 to September 2004, 76 patients(150 breasts) underwent breast augmentation using permanent expandable implant. The procedure was unilateral in 2 women and bilateral in 74 women. Age ranged from 19 to 50 years(mean, 29 years). Fifty nine patients underwent simple augmentation mammaplasty, 7 patients were corrected of their severe asymmetry, 2 patients with the congenital breast deformity underwent mammaplasty using this, and 2 patients who had undergone unilateral mastectomy were reconstructed of their breasts using expandable implant. There were no definite complications such as capsular contracture, implant rupture, asymmetry. And there reported little dissatisfaction about the size. The permanent expandable implants might be good alternatives in cases of ordinary breast augmentation as well as tissue deficient patients, asymmetry, congenital anomaly, and breast reconstruction.

A Study for the Fire Retardant-Characteristics of Expandable Graphite Composite Materials (팽창흑연을 사용한 복합재료의 난연 특성에 관한 연구)

  • Chun, Kwan-Ok;Rie, Dong-Ho
    • Journal of the Korean Society of Safety
    • /
    • v.32 no.3
    • /
    • pp.28-33
    • /
    • 2017
  • In this study, the composite material of expandable graphite was made to the material development for improving such as a composite material of the sandwich panels or material properties of a fire door and was tested by the ISO 1182, ISO 5660-1(Cone calorimeter Method). For the test, the composite material of expandable graphite, what the expandable graphite ratio was increased by respectively 0g~30g, was classified A1,A2, A3, A4, and made to the test specimens. Through cone calorimeter test, peak heat release rate(HRR) and total heat release(THR), expanded thickness and expansion rate of each composite material of expandable graphite, and fire prone crack and mass loss rate after burning was measured. Thus, the effect of the addition of the expandable graphite and whether is suitable for reference as a fire retardant, was analyzed. Consequently the correlation of THR and fire retardant performance rate was confirmed.

A Study of Characteristics Variation of Thermally Expandable Microspheres in Post-polymerization Treatment by Various Initiators

  • You, Hae Na;Kim, Ji Hoo;Kim, Myeong Woo;Kim, Keon Il;Park, Hyun Duk
    • Elastomers and Composites
    • /
    • v.52 no.3
    • /
    • pp.211-215
    • /
    • 2017
  • Thermally expandable microspheres were used as post-treatment initiators of potassium persulfate, sodium bisulfite, and sodium sulfide in order to improve the foaming ability and whiteness when foaming a mixture of thermally expandable microsphers and poly(vinyl chloride). Potassium persulfate showed no significant influence on the foaming behavior, foam expansion, whiteness, and yellowing, whereas in the case of using sodium bisulfite. In particular, sodium bisulfite demonstrated the best efficiency with 2 wt% treatment. The thermally expandable microspheres prepared herein can provide excellent foamability and whiteness, and are expected to be applicable in various fields such as general coating and wallpaper.

Total Body Replacement with an Expandable Cage after en Bloc Lumbar Spondylectomy

  • Shin, Dong-Ah;Kim, Keung-Nyun;Shin, Hyun-Chul;Yoon, Do-Heum
    • Journal of Korean Neurosurgical Society
    • /
    • v.40 no.6
    • /
    • pp.471-475
    • /
    • 2006
  • Complete vertebral tumor resection is important in order to prevent local recurrence. Among the available techniques for total spondylectomy, the total en bloc spondylectomy has been accepted as the most sophisticated one. After a total en bloc spondylectomy, anterior and posterior column reconstruction is mandatory in order to achieve stability. We experienced the usefulness of an expandable cage for anterior column reconstruction especially in this surgery. The chance of cutting the nerve root and damaging the spinal cord is minimized because the size of the expandable cage is initially small enough to be inserted into the anterior column. The technical details of total vertebral body replacement with an expandable cage after an en bloc lumbar spondylectomy are described herein.

THE PROBLEMS OF EXPANDABLE METALLIC STENT FOR THE TREATMENT OF SUBGLOTTIC TRACHEAL AND TRACHEOSTOMAL STENOSIS (성문하 기관 및 기관누공 협착증에 대한 팽창성 금속 스텐트의 문제점)

  • 홍기환;정경호;김중호;한영민
    • Korean Journal of Bronchoesophagology
    • /
    • v.2 no.2
    • /
    • pp.213-221
    • /
    • 1996
  • To evaluate the clinical effectiveness of expandable metallic stents, the stents were implanted under endoscopic guidance with local anesthesia or general anesthesia for maintenance of the constructed subglottic space of trachea. The nine patients with respiration difficulty were subjected for expandable stents. The stenosis of upper airway were due to the framework problem of subglottic trachea and tracheostoma after total laryngectomy. Stents were constructed of 0.4 m stainless steel win in a zigzag configuration of 8 bends. A single stent was 20 m in diameter when fully expanded and 20 mm long. The stents were placed accurately to the stenotic site and followed to the 5 month after stent placement. The stenotic area became narrowed with overgrowing of granuloma in all patients and the metallic stents were removed and the stenotic area reconstructed surgically. As conclusion, this technique for the treatment of the subglottic trachea showed simple and safe, but highly recurred due to overgrowing of granuloma. We suggest that the expandable metallic stent is not encouraging in this study.

  • PDF

A Study on the Application of Underbody Coating for Vehicles with Shell Thickness of Thermally Expandable Microspheres

  • Kim, Jae-Chun;Jeon, Young-Bae;You Park, Hae-Na;Kim, Ji-Hoo;Kim, Myeong Woo
    • Elastomers and Composites
    • /
    • v.53 no.3
    • /
    • pp.136-140
    • /
    • 2018
  • In this study, research was conducted into the manufacture of thermally expandable microspheres for automotive underbody coatings and applications in industry. In particular, the relationship between heat resistance and the ratio of crosslinking agents and initiators in the manufacture of the thermally expandable microspheres was investigated. We focused on the results with various cross-linking agents; our aim was to make the walls of the microspheres thicker to solve the problem of reductions in size caused by shrinkage when the microspheres are heated to $T_m$ ($T_{max}$). We observed the sectional thickness and surface of the samples with thicker walls. The thick thermally expandable microspheres showed reduced shrinkage and excellent stability in spite of prolonged exposure to heat.

Expandable Cage for Cervical Spine Reconstruction

  • Zhang, Ho-Yeol;Thongtrangan, Issada;Le, Hoang;Park, Jon;Kim, Daniel H.
    • Journal of Korean Neurosurgical Society
    • /
    • v.38 no.6
    • /
    • pp.435-441
    • /
    • 2005
  • Objective : Expandable cage used for spinal reconstruction after corpectomy has several advantages over nonexpendable cages. Here we present our clinical experience with the use of this cage after anterior column corpectomy with an average of one year follow up. Methods : Ten patients underwent expandable cage reconstruction of the anterior column after single-level or multilevel corpectomy for various cervical spinal disorders. Anterior plating with or without additional posterior instrumentation were performed in all patients. Functional outcomes, complications, and radiographic outcomes were determined. Results : There was no cage-related complication. Functionally, neurological examination revealed improvement in 7 of 10 patients and no patient had neurological deterioration after the surgery. Immediate stability was achieved and maintained throughout the period of follow-up. There was minimal subsidence [<2mm] noticeable in three of the cases that underwent a two-level corpectomy. Subsidence was noted in osteoporotic patients and patients undergoing multi-level corpectomies. Average pre-operative kyphotic angle was 9 degrees. This was corrected to an average of 5.4 degrees in lordosis postoperatively. Conclusion : In conclusion, expandable cages are safe and effective devices for vertebral body replacement after cervical corpectomy when used in combination with anterior plating with or without additional posterior stabilization. The advantages of using expandable cages include its ability to easily accommodate itself into the corpectomy defect, its ability to tightly purchase into the end plates after expansion and thus minimizing the potential for migration, and finally, its ability to correct kyphosis deformity via its in vivo expansion properties.

Comparison of Clinical and Radiologic Results between Expandable Cages and Titanium Mesh Cages for Thoracolumbar Burst Fracture

  • Lee, Gwang-Jun;Lee, Jung-Kil;Hur, Hyuk;Jang, Jae-Won;Kim, Tae-Sun;Kim, Soo-Han
    • Journal of Korean Neurosurgical Society
    • /
    • v.55 no.3
    • /
    • pp.142-147
    • /
    • 2014
  • Objective : A thoracolumbar burst fracture is usually unstable and can cause neurological deficits and angular deformity. Patients with unstable thoracolumbar burst fracture usually need surgery for decompression of the spinal canal, correction of the angular deformity, and stabilization of the spinal column. We compared two struts, titanium mesh cages (TMCs) and expandable cages. Methods : 33 patients, who underwent anterior thoracolumbar reconstruction using either TMCs (n=16) or expandable cages (n=17) between June 2000 and September 2011 were included in this study. Clinical outcome was measured by visual analogue scale (VAS), American Spinal Injury Association (ASIA) scale and Low Back Outcome Score (LBOS) for functional neurological evaluation. The Cobb angle, body height of the fractured vertebra, the operation time and amount of intra-operative bleeding were measured in both groups. Results : In the expandable cage group, operation time and amount of intraoperative blood loss were lower than that in the TMC group. The mean VAS scores and LBOS in both groups were improved, but no significant difference. Cobb angle was corrected higher than that in expandable cage group from postoperative to the last follow-up. The change in Cobb angles between preoperative, postoperative, and the last follow-up did not show any significant difference. There was no difference in the subsidence of anterior body height between both groups. Conclusion : There was no significant difference in the change in Cobb angles with an inter-group comparison, the expandable cage group showed better results in loss of kyphosis correction, operation time, and amount of intraoperative blood loss.

Covered Self-expandable Metallic Stent Insertion as a Rescue Procedure for Postoperative Leakage after Primary Repair of Perforated Duodenal Ulcer (십이지장 궤양 천공 단순 봉합수술 후 완전 피막형 자가확장 금속 스텐트 삽입술로 치료된 봉합 부위 누출)

  • Yoo, Young Jin;Lee, Yong Kang;Lee, Joong Ho;Lee, Hyung Soon
    • The Korean Journal of Gastroenterology
    • /
    • v.72 no.5
    • /
    • pp.262-266
    • /
    • 2018
  • Surgery has been the standard treatment for perforated duodenal ulcers, with mostly good results. However, the resolution of postoperative leakage after primary repair of perforated duodenal ulcer remains challenging. There are several choices for re-operation required in persistent leakage from perforated duodenal ulcers. However, many of these choices are complicated surgical procedures requiring prolonged general anesthesia that may increase the chances of morbidity and mortality. Several recent reports have demonstrated postoperative leakage after primary repair of a perforated duodenal ulcer treated with endoscopic insertion using a covered self-expandable metallic stent, with good clinical results. We report a case with postoperative leakage after primary repair of a perforated duodenal ulcer treated using a covered self-expandable metallic stent.