• Title/Summary/Keyword: Exhaust ventilation system

Search Result 186, Processing Time 0.027 seconds

Numerical Analysis of the Kitchen Hood Ventilation System for Marine Environment (선박용 주방후드 환기시스템에 관한 수치해석)

  • Yi, Chung-Seob
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.14 no.5
    • /
    • pp.96-101
    • /
    • 2015
  • This study regards distributions of flow in the ventilation system used in the kitchen hood in a ship. In this study, for describing the flow in the ventilation system, three-dimensional steady-state turbulence was assumed for the governing equation. When the plume was formed, three gases, CO, CO2, and HCL, in the flow field of the hood were considered as the plume, and it was assumed that the sum of concentrations of the gases was 100%. As a result, it could be confirmed that the plume was smoothly discharged when the flow rate of the supply was ten times lower than that of the exhaust.

The study of ventilation system during fire in road tunnel with bi-directional or congested unidirectional traffic (교통정체가 심한 도로터널에 대한 화재시 제연방식에 관한 연구)

  • Yoo, Ji-Oh;Shin, Hyun-Jun;Nam, Chang-Ho
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.474-479
    • /
    • 2008
  • The purpose of this paper is to estimate the fire safety in tunnels with bi-directional and/or congested unidirectional traffic where there may be people on both sides of the fire. Therefore, the spread and movement of smoke are simulated by Fire Dynamic Simulator code under different ventilation systems, longitudinal, semi-transverse, large port exhaust system. And as quantitative risk index, FED (Fractional Effective Dose) for each ventilation system are calculated and compared by existed code developed previous research.

  • PDF

A Study on the Ventilation Method for a Factory with a Sealed Structure

  • Kim, Yeong-Sik;Yi, Chung-Seob;Lee, Dae-Chul;Jeong, Hyo-Min;Chung, Han-Shik
    • Journal of Power System Engineering
    • /
    • v.18 no.6
    • /
    • pp.159-165
    • /
    • 2014
  • On this work, the importance of industrial ventilation was investigated and examined the theoretical point and problems about general ventilation of factory exposed on high temperature during summer. As a case study, the ventilation planning of the printed circuit board (PCB) etching process for an electronic company was carried out and each of those characteristics were compared by installing actual ventilation systems and measuring the changing state of the working environment in accordance with ventilation method during summer. The purpose of the study is to present an efficient ventilation method for a factory with a closed structure under high temperature environment. In summary, for a factory with a sealed structure such as the target PCB manufacturing factory in this study, the forced supply and exhaust method was the most appropriate ventilation method for maintaining a low.

Study on Heat and Smoke Exhaust Characteristics for Different Operating Modes of Platform and Tunnel Fans during a Passenger Train Fire (전동차 화재시 승강장 및 터널 환기실의 팬 작동에 따른 열 및 연기 배출 특성 연구)

  • Chang, Hee-Chul;Kim, Tae-Kuk;Son, Bong-Sei;Park, Won-Hee
    • Fire Science and Engineering
    • /
    • v.22 no.1
    • /
    • pp.61-67
    • /
    • 2008
  • This study is focused on the numerical predictions of heat and smoke exhaust characteristics in an underground subway station stopping a fire train. Various ventilation operating modes with the fan equipped the platform and tunnels are considered. Distributions of temperature, carbon monoxide and visibility at a height of 1.7 m(breath height) above the platform are analysed for different ventilation fan operation mode. The numerical results show that smoke and heat is rapidly removed through tunnel by operating the tunnels fans. We suggested that during evacuation of passengers is not completed, the ventilation system in the platform is activated. After completion of passenger evacuation tunnel fans are activated but the fans in the platform are stopped.

Control of Suspended Dust in Various Ventilation Systems of Cement Packaging Process (시멘트 포장공정에서 환기시스템에 따른 발생분진의 제어)

  • Lee, Seung-Chul;Kim, Soo-Chang;Noh, Kwang-Chul;Park, Myoung-Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.3
    • /
    • pp.463-469
    • /
    • 2009
  • We performed the experimental study on the control of suspended dust in a cement packaging process for various ventilation systems. To effectively remove the dust generated in the cement packaging process, three different kinds of ventilation system, such as local exhaust ventilation, electrostatic scrubber, and local air supply system, were adopted. Dust concentrations in the packaging process were measured with the variation of the airflow rate of the ventilation systems and then their ventilation performance were evaluated. From the results, we knew that the ventilation performance was the best when the local exhaust ventilation and the electrostatic scrubber were simultaneously operated in the packaging process. In the electrostatic scrubber system, the effect of the airflow rate on the indoor dust removal efficiency was negligible so hat he system ust be operated at $2,700m^3/h$ for saving power consumption.

Study on the Performance Improvement of Roof Fan Used for Local Exhaust System Installed in Apartment (공동주택의 국소배기용 루프팬 성능개선에 관한 연구)

  • Kwon, Yong-Il;Jeong, Yeol-Wha;Ahn, Jung-Hun
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.24 no.2
    • /
    • pp.136-141
    • /
    • 2012
  • Performance improvement of local exhaust system used in toilet and cooking place are main concern in a field of ventilation. In Korea, There are many high riser residential apartments in recent years. These buildings were not viewed as being major contributors to exhaust pollutants producted in indoor. It was because many engineers thought that exhaust in high riser building depends on stack effect. This study investigates on the performance improvement of terminal device, roof fan, of vertical spiral duct used in high riser residential apartments. This paper focuses mainly on the effect of accessories, number or shape of blades, composed of roof fan with function of exhaust air volume of toilet and cooking place. Roof fan with 10 blades is observed at optimum exhaust performance in this study.

A Prediction of Hybrid Ventilation System Performance in Apartment House (공동주택 하이브리드(Hybrid) 환기시스템의 성능예측)

  • Hwang, Ji-Hyeon;Oh, Chang-Yong;Choi, Hung-Won;Kim, Moo-Hyun
    • Proceedings of the SAREK Conference
    • /
    • 2005.11a
    • /
    • pp.33-38
    • /
    • 2005
  • A hybrid ventilation system was introduced to predict the ventilation performance of the apartments. This ventilation system was composed of the natural supply-air inlet and the forced exhaust-air outlet. Analysis was conducted by CFD technique and was performed on three ventilating flow rates; 30, 60, 120 $m^3/h$. As the results, residents feel comfortable thermally and in air flow conditions for 60 $m^3/h$. But the case of 30 $m^3/h$ shows 1100ppm of $CO_2$ concentration due to the deficient of air flow rate. In the case of 120 $m^3/h$, however, residents feel uncomfortable thermally and in air currents. In this study the energy saving for space heating is also an important factor. A detailed prediction for more complicated whole apartment space will be investigated in the future.

  • PDF

A Study on The Performance of a Heat Recovery Ventilator According to the Properties of Spacers (스페이서의 재질변화에 따른 전열교환기 성능변화에 관한 연구)

  • Lim, Tae-Kun;Jeon, Byung-Heon;Kim, Jong-Won;Jung, Sung-Hak;Lee, Seung-Kap;Ahn, Young-Chull
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.24 no.3
    • /
    • pp.224-229
    • /
    • 2012
  • The importance of ventilation system is being emphasized by interest of indoor air quality. Especially, heat recovery ventilation system has attracted attention as most effective ventilation plan. Because it can reduce hazardous construction materials, indoor air pollutions, and also can reduce air conditioning energy cost. In heat recovery ventilator, the element core is the most important part. The element core is composed of liner and spacer. And liner and spacer are stacked alternately. On the Liner, heat and humidity transfer are made between supply and exhaust air. And spacer plays a role as a tunnel of exhaust and supply. In this study, we investigated and analyzed the efficiency of a heat recovery ventilator, when the spacer's properties are changed. As a result, difference spacer's properties affect an efficiency of heat recovery ventilator.