• 제목/요약/키워드: Exhaust fan

검색결과 134건 처리시간 0.031초

레이저 3차원 진동측정기와 마이크로폰을 이용한 진공청소기용 팬모터의 실험적인 공력소음 분석 (The Experimental Analysis of Aerodynamic Sound for Fan Motor in a Vacuum Cleaner Using Laser 3-D Scanning Vibrometer and Microphone)

  • 곽이구;안재신;김재열
    • 한국정밀공학회지
    • /
    • 제22권3호
    • /
    • pp.46-51
    • /
    • 2005
  • The vacuum cleaner motor runs at very high speed for suction power. Specially, motor power is provided by the impeller being rotated at very high speed. The centrifugal fan consists of the impeller, the diffuser, and the circular casing. Due to the high rotating speed of the impeller and small gap distance between the impeller and the diffuser, the level of noise in the centrifugal fan is at BPF(Blade Passage Frequency) and its harmonic frequencies. In order to calculate the sound pressure of centrifugal fan, unsteady flow data are needed. The cause of noise is obtained by dividing the fluid noise by exhaust flow of fan and vibration noise by rotational vibration of vacuum cleaner fan motor. Until now, an accelerometer has been used to measure vibration. However, it can not measure vibration in some parts of brush and commutator because of motor construction and 3-D vibrating mode. This study was conducted to perform accurate analysis of vibration and aerodynamic sound for fan motor in a vacuum cleaner using a laser vibration analyzer. A silent fan motor can be designed using the data measured in this study.

가스 스월버너의 공연비 제어에 관한 연구 (Study on the control of fuel-air ratio ofgas swirl burner)

  • 김인규;김영수;김양호;김경수;김지원
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 1999년도 제19회 KOSCO SYMPOSIUM 논문집
    • /
    • pp.129-138
    • /
    • 1999
  • In this paper, our main issue is that establishing the control procedure of continuous gas flow rate according to combustion fan RPM. For this, first, we decide the optimum operating condition of gas swirl burner through analysis of combustion characteristics - thermal efficiency, combustion efficiency and exhaust gases such as CO, $CO_{2}$, $O_{2}$, $NO_{x}$ and THC. Second, fuel gas flow rate of gas valve is decided with considering excess air ratio and combustion fan RPM is decided by the target of combustion air flow rate. Finally, experimental operating equation is acquired by regression for gas valve and combustion fan. This equation is the control equation of continuous gas flow rate and always gas flow rate is decided by combustion fan operating RPM.

  • PDF

배기소음기의 구조개선에 의한 소음감쇠 효과에 관한 연구 (A Study on Sound Attenuation by Structure Improvement of Silencer for Exhaust Fan)

  • 윤세철;이해경
    • 한국안전학회지
    • /
    • 제10권2호
    • /
    • pp.32-38
    • /
    • 1995
  • The silencers are used to attenuate noise generated by the exhaust fan for industrial processes. The types of silencers applied in this study are absorptive duct silencer, expansion chamber, absorptive chamber and resonator. This study was carried out to verify the attenuation by the various silencers and elements. As a result, the difference of attenuation between the calculation and the measurement was about 1-7㏈. The attenuation by absorptive duct silencer and absorptive chamber was negligible at frequencies below 250Hz. The expansion chamber should be used for low frequency applications where the absorptive duct silencer was Ineffective. The attenuation by resonator may be realised when the ratio of frequency to resonant frequency approaches 1.

  • PDF

돈사용 환기팬을 위한 돈사 내 온도 분포 특성 (Characteristics of Temperature Distribution of Pen for Exhaust Fan of Ventilation System)

  • 김현태;김웅
    • 한국축산시설환경학회지
    • /
    • 제20권4호
    • /
    • pp.155-160
    • /
    • 2014
  • This study was researched for use by data for the improvement of ventilation system of optimum environmental control systems. The ventilation system for windowless swine housing was installed negative pressure system that circular pipe duct for inlet was installed on the ceiling and axial flow fan for exhaust was installed on the sidewall. The temperatures in the pen was measured using infrared thermography camera and thermocouple with data-logger. The temperature measurement points was selected by infrared thermography camera is alley (G), inlet (A), front-upper (B), front-lower (C), rear-upper (D), rear-lower (E), forward fan (F). The temperature measured at those selected points for temperature distribution was $28^{\circ}C$ that was maintained setting temperature in suitably. The temperature deviations of F point and A~E points in windowless swine housing was less then average $0.5^{\circ}C$. The result of air velocity of measured points was suitable to the breeding of pigs.

조합형 복합상영관에서의 화재조건에 따른 초기화재 거동해석 (Primary Fire Behavior of Compounded Multiplex Theater with Various Fire Conditions)

  • 박용환
    • 한국화재소방학회논문지
    • /
    • 제21권1호
    • /
    • pp.1-6
    • /
    • 2007
  • 본 연구는 최근 급격히 늘어나고 있는 복합상영관의 화재안전 성능을 확보하기 위한 차원에서 설계단계에 있는 조합형 복합상영관에 대하여 화재모델링에 의한 공간특성 및 화재조건에 따른 초기화재 거동 특성을 다양하게 분석함으로써 방재대책 개선의 방향을 제시하고자 하였다. 화재하중이 작더라도 연기유동 특성으로 인하여 개구부에서의 온도상승속도는 오히려 증가될 수 있으며, 과다한 방염제의 사용은 오히려 연기발생량을 증가시켜 피난을 어렵게 하고 조기 질식사의 원인을 제공할 수 있는 것으로 나타났다. 설치된 배기구가 미 작동 시 단지 연기의 배출이 정지될 뿐 아니라 헤드의 작동시간을 지연시킴으로 인해 화재 진압도 지연되는 것으로 나타났다.

진공청소기용 팬 모터의 비정상 유동 해석 및 공력소음 해석 (The Analysis of the Unsteady Flow Field and Aerodynamic Sound of Fan Motor in a Vacuum Cleaner)

  • 김재열;심재기;송경석;오성민;양동조;김우진
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 2004년도 춘계학술대회 논문집
    • /
    • pp.281-286
    • /
    • 2004
  • The vacuum cleaner motor runs on very high speed for the suction power. Specially, the motive power is provided by the impeller being rotate on very high speed. And centrifugal fan consists of the impeller, the diffuser, and the circular casing. Due to the high rotating speed or the impeller and small gap distance between the impeller and diffuser, the centrifugal fan makes very high noise level at BPF and harmonic frequencies. In order to calculate the sound pressure of centrifugal fan, the unsteady flow data is needed. And Noise cause is dividing to fluid noise by exhaust flow of fan and vibration noise by rotational vibration of vacuum cleaner fan motor. Until now, measuring method has been used to measure vibration by the accelerometer; this method has been not measured for the vibration in some parts of brush and commutator because of motor construction and 3-D vibrating mode. This paper was purposed on the accurate analysis, using laser vibration analyzer,. By using this measured data of noise cause against the difficult part in old times, we would like to use for the design of silent fan motor.

  • PDF

화재열차의 역사 접근 시 PSD가 설치된 역사 제연을 위한 환기장치 운전 비정상상태 해석 (A transient CFD simulation of ventilation system operation for smoke control in a subway station equipped with a Platform Screen Door(PSD) when a train under fire is approaching the station)

  • 신규호;허남건;원찬식
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2006년 제4회 한국유체공학학술대회 논문집
    • /
    • pp.269-272
    • /
    • 2006
  • The heat and smoke which generated by subway under fire is one of the most harmful factor in air tighten underground station. To prevent this, Trackway Exhaust System(TES) can be used. The heat released from the train running in the tunnel raises the temperature at the platform and the trackway, and thus proper ventilation system is required for comfortable underground environment. When the fire is occurred, TES is operated as smoke exhaust mode from normal ventilation mode. In the present study, the subway station which is one of the line number 9 in Seoul subway is modeled, and fired situation is simulated with several ventilation mode of ventilation system in trackway. For this simulation whole station is modeled. Non steady state 3D simulation which considered train under fire is entering to the station is performed. Temperature and smoke distribution in platform and trackway are compared. To represent heat by fire, heat flux was given to the fired carriage, also to describe smoke by fire, concentration of CO is represented. As the result of present study, temperature and smoke distribution is different as the method of ventilation in trackway and platform is changed. In over side of trackway, the fan must be operated as exhaust mode for efficient elimination of heat and smoke, and supply mode of fan operation in under side shows better distribution of heat and smoke. The ventilation system which is changed from ventilation mode to exhaust mode can be applied to control heat and smoke under fire.

  • PDF

산업용 Turbo형 송풍기의 Cutoff 각도에 따른 유동특성 (Flow Characteristics due to Cutoff angle of Turbo-Fan for Industries)

  • 윤지훈;정인국;이중섭;서정세
    • 한국기계가공학회지
    • /
    • 제10권5호
    • /
    • pp.91-96
    • /
    • 2011
  • This study aims to analyze the flow characteristics of turbo-fan which is applied to the industrial field. Numerical analysis has been carried out to investigate the pulsation behavior of exhaust air flown out turbo fan by rotating impeller with constant speed. Moving mesh technique is proved as time-accurate solution for the flow inside impeller. As numerical results come within the error range of 1% by comparing with theoretical results, the numerical analysis can be verified. Cutoff angle has large influence on the amplitude of pulsation and the least pulsation of flow can be generated by the cutoff angle of $20^{\circ}$.

터널화재시 환기방식에 따른 연기거동에 관한 실험적 연구 (An Experimental Study of Smoke Movement in Tunnel Fires According to Ventilation Method)

  • 이성룡;정진용;김충익;유홍선
    • 설비공학논문집
    • /
    • 제14권9호
    • /
    • pp.691-698
    • /
    • 2002
  • In this study, reduced-scale experiments were conducted to analyze smoke movement in tunnel fires according to vepntilation method. The 1/20 scale experiments were carried out under the Froude scaling using gasoline pool fires ranging from 6.6 to 10 cm in diameter corresponding to total heat release rate from 0.714 to 2.5 kW. Temperatures near the ceiling were lowered by installing the vent, and much lowered by operating fan compared wiht tile case without vent. In case of forced ventilation, the exhaust fan was more effective than the intake fan. Vertical temperatures at the upper part of the tunnel were also lowered by installing the vent. But, when suction fan was operated, temperatures at the lower part of the tunnel were higher than that without vent.

무창 분만ㆍ자돈사내에서 환기시스템별 혹한기 환경 조사 (Environmental Survey to a Ventilation System on the Enclosed Farrowing-nursery Pig House in Winter)

  • 유용희;송준익;정종원;김태일;최희철;양창범;이영윤
    • 한국축산시설환경학회지
    • /
    • 제10권1호
    • /
    • pp.23-28
    • /
    • 2004
  • 본 연구는 국내의 있는 무창 분만ㆍ자돈사에 대하여 환기시스템 정립의 기초자료를 수집하고자 수행하였다. 측벽상단입기 지붕굴뚝배기, 천공천장입기 지붕굴뚝배기, 측벽덕트입기 지붕굴뚝배기, 측벽덕트입기 측벽배기의 4종류 무창분만ㆍ자돈사 환기 형태에 대하여 조사하였다. 겨울철 돈사 내 온도, 습도, 공기유속, 암모니아가스 농도의 환경상태를 조사하였다. 겨울철 각 환기 형태별 돈사 내 온도는 환기형태에 따른 온도의 차이는 없었다. 공기유속은 측벽덕트입기 측벽배기가 다른 환기 형태보다 높은 공기 유속이 있었다. 돈사 공간내 각 환기형태별 공기유동은 측벽덕트입기 지붕굴뚝배기, 측벽덕트입기 측벽배기 환기형태가 비교적 다른 환기 시스템에 비교하여 원활한 공기유동이 있는 것으로 나타났다. 암모니아(NH$_3$) 농도도 다른 환기형태보다 측벽덕트입기 측벽배기가 낮은 경향을 보였다. 따라서, 측벽덕트입기 지붕굴뚝배기, 측벽덕트입기 측벽배기가 국내의 무창 분만ㆍ자돈사 환기방식에 적용할 수 있을 것으로 판단되었다.

  • PDF