공동주택 주방의 급ㆍ배기효율을 고려한 기계환기 설계에 관한 연구 (A Study on the Mechanical Ventilation Design that Consider Supply and Exhaust Efficiency of the Apartment House Kitchen)

  • 함진식
    • 한국주거학회논문집
    • /
    • 제15권3호
    • /
    • pp.101-108
    • /
    • 2004
  • To find more efficient exhaust effect, air curtain of upward or downward trend in gas table and left or right side of range hood were made. As result that film vapor from range hood lower part by digital camera, the air current change by moving existence and nonexistence of exhaust fan and direction of air curtain were known. Under all experiment condition, upward air curtain superior exhaust performance.

조기이유 자돈 사육을 위한 이동식 자돈사 개발에 관한 연구 (Study on the Development of the Mobile Pig Nursery for Early Weaned Piglet)

  • 유용희;이덕수;정일병;이진우;전병수;한정대
    • 한국축산시설환경학회지
    • /
    • 제4권1호
    • /
    • pp.1-8
    • /
    • 1998
  • The objective of this study was conducted to develope a mobile pig nursery(MPN) for segregation of early weaned piglet. The units of MPN was consisted of 4 rectangle-type pens, 1 workroom, 2 doors, 3 windows, 1 air-inlet, 1 exhaust fan, and 1 cooling and heating system. Total of 40 piglet were weaned at 7 days of age. The period of the feeding test was 63 days. The results obtained are as follows: 1. The insulation thickness was 70, 70 and 50 mm of roof, floor and wall, respectively. R-value was 15.32 and 10.32 of roof and wall, respectively. 2. Exhaust fan( 30.48) was installed near back door 40cm from the bottom. When exhaust fan speeds were 15, 20, 30 and 35%, Air ventilation was required 9.75, 7.07, 1.72, 1.45 minutes of respectively. 3. Average temperature in the MPN was able to maintain 27∼28$^{\circ}C$ from 7∼28 days of age, 24∼25$^{\circ}C$ from 35∼56 days of age and 20∼21.5$^{\circ}C$ from 56∼70 days of age. 4. Average daily gain, feed intake and feed conversion were 420.6g, 761.5g, 1.81 respectively.

굴착중인 장대터널 내 최적의 환기시스템에 관한 연구 (The Study on Optimum Ventilation System during Long Tunnel Construction)

  • 임한욱;오병화
    • 산업기술연구
    • /
    • 제26권A호
    • /
    • pp.3-15
    • /
    • 2006
  • To determine the optimum ventilation systems during long tunnel excavation, the velocity vector profile and the contaminant's distribution at working place are studied using 2-D, 3-D numerical analysis. The main results can be summarized as follow; In case of long tunnels, blower-exhaust-mixture types which enable to use soft blast ducts is most appropriate in terms of ventilation and economical efficiency. Of the same ventilation types, ventilation efficiency has a difference according to blast ducts and the distance between fan and working place. The 3-D numerical result shows that arranging blower and exhaust ducts in the right and left corners of the tunnel respectively is effective to discharge contaminant. The result of the real measurement shows that CO concentration can be reduced to below 50 ppm, which is regulation value, as 16-minutes fan operation goes on.

  • PDF

초고층 공동주택 국소배기용 입상덕트의 배기성능평가 (The Performance Evaluation of the Exhaust Stack used in High Riser Public House)

  • 권용일;김웅용;신현곤
    • 유기물자원화
    • /
    • 제22권3호
    • /
    • pp.60-67
    • /
    • 2014
  • 고층 공공주택의 화장실과 주방에 적용되는 배기 시스템은 기본적으로 두 종류의 환기팬이 적용된다. 가지 기본 유형의 지붕 팬이다. 그 하나가 자연 통풍력을 활용하는 무동력 팬이고 다른 하나는 자연 통풍력이 없을 때, 모터를 활용하여 강제로 구동하는 팬을 적용하는 방식이다. 자연/강제 겸용으로 지붕에 적용되는 환기팬은 회전축에 모터가 있습니다. 대한민국에는 많은 고층건물이 있다. 그러나 고층건물의 환기가 굴뚝효과에 의존된다고 판단하였기 때문에 이러한 건물의 실내에서 발생하는 오염물질의 제거에 대한 관심을 크게 갖지 않고 있다. 본 연구는 외기압력과 초고층아파트에 사용되는 배기연돌에 적용되는 차압에 의해 결정되는 연돌압력을 조사하기 위함이다. 본 논문은 화장실 배기풍량과 대기의 자연풍속을 변수로 하여 루프팬에 설치된 모타의 전력공급시간을 판단함으로써 기존 배기팬보다 향상된 배기효율을 예측하기 위해, 수행되었다.

초고층공동주택 국소배기용 입상덕트시스템의 제어성능평가에 관한 연구 (Study on the Control Performance Evaluation of the Exhaust Stack used in High Riser Public House)

  • 권용일;안정헌
    • 설비공학논문집
    • /
    • 제21권2호
    • /
    • pp.103-108
    • /
    • 2009
  • Local exhaust system used in toilet and cooking place of low-rise public house installed roof ventilator at terminal of stack. There are many high riser public houses in Korea. These buildings were not viewed as being major contributors to exhaust pollutants producted in indoor. It was because many engineers thought that exhaust in high riser public house depends on stack effect. But Neutral pressure level represents in a terminal of stack with air tightness for the best exhaust efficiency. Thereby, lower floors have the worst indoor air quality. This paper focuses mainly on the exhaust efficiency improved by roof fan with motor installed in high riser public house. It is observed there is higher exhaust efficiency than the existing natural roof ventilator.

공동주택 화장실의 기계 환기시스템에 관한 연구 (A Study on the Mechanical Ventilation System of Bathroom in Apartment House)

  • 함진식
    • 한국주거학회논문집
    • /
    • 제12권3호
    • /
    • pp.141-148
    • /
    • 2001
  • To design mechanical ventilation for bathroom of apartment houses where air supply and exhaust are taken into consideration, mock-ups of ventilation systems, widely used in bathroom of apartment houses with an area of 100$\textrm{m}^2$, were made and installed in a laboratory. These ventilation mock-ups were available for control of air supply and exhaust, and the sizes of supply openings were 40cm${\times}$1cm, 40cm${\times}$3cm, and 40cm${\times}$5cm. They were installed at five positions, spaced 45cm at a height of 5cm from the floor. The exhaust fan was designed for its operating voltage to be set to five steps(100V, 130V, 150V, 180V and 220V) in order to control its air flow rates. When the size and position of each supply opening were changed with the wind velocity of the exhaust fan set to the step 5, the ventilation rates were measured and analyzed by the concentration decay method of tracer gas method, in order to present an efficient mechanical ventilation system. The results of the study revealed that the ventilations rates would increase in the presence of supply openings, compared to the absence of supply openings, and that the larger the size of the supply opening, the more the ventilation rates. Therefore, it was found necessary to take air supply into consideration.

  • PDF

초고층 공동주택의 주방.욕실 배기 풍속을 풍력발전에 활용하는 방안 (A Study on the Wind Power Generation Using Vertical Exhaust Air Duct of the High-Rise Apartments)

  • 이용호;김성용;황정하;박진철
    • 한국태양에너지학회 논문집
    • /
    • 제32권3호
    • /
    • pp.1-10
    • /
    • 2012
  • The purpose of this study was to promote the utilization of wind velocity of kitchen and bathroom exhaust ducts for wind power generation in high-rise apartments. The research content can be summarized as follows: 1) Nine high-rise apartments were examined for the installation of kitchen and bathroom exhaust ducts located in the pipe shaft (PS) section. After selecting simulation candidates, a simulation was performed with the STAR-CCM+ Ver 5.06 program. 2) Of nine high-rise apartments, seven had kitchen and bathroom exhaust ducts, whose cross section was in the range of $0.16m^2{\sim}0.4m^2$. The area ratio between the exhaust ducts and PS section (cross section of exhaust duct/area of PS section ${\times}$ 100) was on average 3.2%. 3) The simulation results were analyzed. As a result, the smaller cross section kitchen and bathroom exhaust ducts had, the more advantages there were for increasing exhaust wind velocity. If an out air inlet duct is installed to the old kitchen and bathroom exhaust ducts, it will increase exhaust wind velocity by 3.01~3.98m/s and contribute to the proper wind velocity level (3.0m/s). 4) When the simultaneous usage rate between the kitchen and bathroom exhaust fan increased from 20% to 60%, exhaust wind velocity increased. The "entire house holds" condition for exhaust fan operation provided more even exhaust wind velocity than the "some house holds" condition. 5) Exhaust wind velocity increased in the order of amplified (T-3), induced (T-2) and vertical (T-1) top of kitchen and bathroom exhaust ducts. Of them, the amplified type (T-3) was under the least influence of external wind velocity and thus the most proper for kitchen and bathroom exhaust duct tops.

Turbo Fan 형상에 따른 맥동압력에 관한 수치해석 (A Numerical Analysis on Pressure Pulsation with Turbo Fan Shape)

  • 이중섭;서정세;송철기;홍정규;신유인
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.1355-1360
    • /
    • 2009
  • This study simulates the flow characteristics of the turbo-fan which was applied to the industrial scale. Numerical analysis has been carried out to investigate a pulsation behavior of exhaust air that flow out the turbo fan, considering a constant rotating rate of impeller. Moving mesh technique provides time-accurate solutions for the flow inside an impeller. From the numerical results, FFT analysis has been made for pressure pulsations inside turbo-fan casing. The numerical simulation shows the pulsation of model-2 has higher than model. Additionally, BPF value is almost same as the numerical results.

  • PDF

랜지후드의 설치 높이에 따른 오염물질의 배출성능에 관한 연구 (A Study on the Exhaust Performance of Contaminant by Establishment Height of Hood)

  • 송필동;박명길;함진식
    • 한국주거학회:학술대회논문집
    • /
    • 한국주거학회 2001년도 학술발표대회논문집
    • /
    • pp.99-104
    • /
    • 2001
  • This paper is contents that experiment exhaust performance of contaminant by establishment height gas table and hood establishment height. Hood made to control from gas table to 10 centimeters space from 30 centimeters to 70 centimeters. Exhaust fan operated by 110V, 160V, 220V, and gas used propane gas. Center part appeared highest as result that measure wind velocity and temperature from hood lower part. Wind velocity from hood lower part was proved that dominate contaminant exhaust performance. Exhaust performance of carbon dioxide and heat showed that 30 centimeters case overmatches because establishment height of hood compares 80 centimeters. Case of carbon dioxide of exhaust performance by establishment height of hood overmatched more than heat.

  • PDF

선박 연돌 형상이 배기가스 흐름에 미치는 영향과 연돌 설계 (CFD interpretation of gas flow around Ship's Funnel and Optimum Design Criterion)

  • 신현준;박상민;김종화
    • 대한조선학회 특별논문집
    • /
    • 대한조선학회 2011년도 특별논문집
    • /
    • pp.63-69
    • /
    • 2011
  • Exhaust gases of a vessel from a main engine, a diesel generator and an incinerator contain very harmful substances like soot, $SO_2$ and NOx. Careful design of funnel shape is required to prevent those harmful exhaust gases from influencing on accommodation and a fan room. Meanwhile, the exhaust gases are also hot enough to damage electronic devices like radar. Therefore the funnel design should be considered so that electronic devices are not directly exposed to the exhaust gas in the strong stern wind. This study may propose guidelines of optimum design criterion for the anti-thermal damage design of the electronic devices and anti-recirculating design of harmful exhaust gas near the accommodation. From CFD analyses, we can understand that the major factors affecting the exhaust gas dispersion are the large scale mixing by separation vortices and the sluggish flow in the recirculation region. We hope that the funnel flow analysis around ship's funnel is used for practical optimum funnel design to minimize the exhaust gas dispersion by adjusting the funnel shape, the position of the exhaust pipe, the shape of bulwark, the exhaust direction of air ventilated an engine room and the angle of the exhaust pipe.