• Title/Summary/Keyword: Excessive use

Search Result 990, Processing Time 0.027 seconds

An Importance-Performance Analysis of Secondary Science Teachers' Adaptive Practice (중등 과학교사의 적응적 실행에 대한 중요도-실행도 분석)

  • Heekyong Kim
    • Journal of The Korean Association For Science Education
    • /
    • v.43 no.3
    • /
    • pp.295-306
    • /
    • 2023
  • In this study, we explored science teachers' perceptions of adaptive practice in terms of importance and practice. For this purpose, an adaptive practice questionnaire was developed targeting secondary science teachers, and the responses of 128 science teachers were analyzed. The results of this study were as follows: First, the science teachers responded that all 17 items regarding adaptive practice were important. In particular, items related to 'addition of examples', 'adjustment of the level/range of concepts', and 'encouragement of student participation' showed high importance and performance levels. Second, the results of the IPA concerning adaptive practice showed that the items needing intensive improvement due to high importance but low performance were 'encouraging students' self-directed learning' and 'monitoring and responding to individual differences'. The science teachers identified a lack of time and uniform curriculum as the reasons for the low level of practice despite the high importance of these items. Third, regarding the IPA of the adaptive practice items, the items located in the fourth area, an excessive area, concerned 'pace control', 'modifying activities', and 'metaphor use'. More specifically, considering that 'metaphor use' was the only item with a higher level of performance than importance, it is necessary to reconsider whether problems are caused by excessive use. Fourth, analyzing the responses regarding the reasons for the difference in importance and performance revealed that the factors related to teachers included teachers' lack of knowledge or ability, and the tendency to implement as planned. As for student factors, an excessive number of students, differences in the levels of students, and a tendency to prefer classes centered on entrance exams were identified. As environmental factors, a uniform curriculum, conditions for experiments, evaluation systems, and external demands were mentioned. Finally, the implications of the results of this study for science education were discussed.

Use of Mobile Phones and Cancer Risk

  • Ayanda, Olushola S.;Baba, Alafara A.;Ayanda, Omolola T.
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.13 no.1
    • /
    • pp.403-406
    • /
    • 2012
  • Mobile phones work by transmitting and receiving radio frequency microwave radiation. The radio frequency (RF) emitted by mobile phones is stronger than FM radio signal which are known to cause cancer. Though research and evidence available on the risk of cancer by mobile phones does not provide a clear and direct support that mobile phones cause cancers. Evidence does not also support an association between exposure to radio frequency and microwave radiation from mobile phones and direct effects on health. It is however clear that lack of available evidence of cancer as regards the use of mobile phone should not be interpreted as proof of absence of cancer risk, so that excessive use of mobile phones should be taken very seriously and with caution to prevent cancer.

The Influence of Home Position(H.P.) and Random Position(R.P.) on the Shape of Prepared Tooth Surfaces -Upper Left 1st Molar for Full Cast Crown- (시술자세가 치관 삭제면 형태에 미치는 영향 -상악 좌측 제 1 대구치의 전부 주조관-)

  • Lee, Seung-Jeong;Choi, Dae-Gyun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.17 no.4
    • /
    • pp.257-274
    • /
    • 2001
  • To properly prepare teeth, dentists require a direct view of the working area and are often placed in a difficult position, moreover, a high proportion of dentists suffer from headache and back pain. Dentists who make use of the dental mirror and position their patients carefully to gain a proper view report less headache, pain and discomfort in the shoulders. It is recommended that dentists learn the "Home Position(H.P.)" which among the various "Random Position(R.P.)" methods, enables dentists to approach their patients in a stable posture. The purpose of this study was to compare tooth preparation in the H.P. and the R.P., and evaluate the clinical efficacy of the H.P.. Tooth preparation for a full cast crown was performed on the maxillary left 1st molar using the H.P. and the R.P., and the shapes of the prepared tooth surfaces at the two different operating positions were compared. The amount of occlusal reduction, marginal width, height, and axial taper were measured and analyzed. A T-test was performed separately to compare the results of the H.P. and the R.P. with respect to the accuracy of the corresponding tooth reduction. The results were as follows. ; 1. The amount of occlusal reduction was excessive on the mesiobuccal cusp(P<0.05), and deficient on the lingual cusp in the H.P.(P<0.01). In the R.P., this was excessive on the buccal cusp and deficient on the fossa and distolingual cusp(P<0.01). 2. The amounts of marginal width were excessive in all areas except on the lingual and mesial surfaces in the H.P. and lingual surface in the R.P.(P<0.01). 3. The marginal heights were achieved more accurately in the R.P. than the H.P.(P<0.01). 4. Axial surface taper was excessive in all areas in the H.P.(P<0.01). But the axial taper of measured areas was even, and tooth is more like to retain its original axis after reduction. In the R.P., axial surface taper was excessive on the mesial and buccal area, and deficient on the distolingual area(P<0.01), and therefore, the axis of the prepared teeth was tipped in the distolingual direction. 5. The times needed for preparation were 12 minutes and 49 seconds in the H.P., and 11 minutes and 35 seconds in the R.P., and the R.P. was statistically faster(P<0.01). The tooth preparation in the H.P. achieved its goal, in that it enabled the operator to make even tooth reduction. In conclusion, the H.P. system offers an improved method that can be used in clinic after specific training.

  • PDF

EFFICIENT PLOTTING OF CLOSED POLAR CURVES WITH MATHEMATICA

  • Lee, Kwang-Bok;Kim, Young-Ik
    • The Pure and Applied Mathematics
    • /
    • v.5 no.2
    • /
    • pp.133-142
    • /
    • 1998
  • A simple mathematical theory is developed on the periodicity of elementary polar functions. The periodicity plays an important role in efficient plotting of some closed polar curves, without the excessive use of plotting devices and materials. An efficient plotting algorithm utilizing the periodicity is proposed and its implementation by a Mathematica program is introduced for a family of closed polar functions.

  • PDF

The Study for the KOMPSAT-3 Image Data Compression

  • Lee S.G.;Lee S.T.
    • Proceedings of the KSRS Conference
    • /
    • 2005.10a
    • /
    • pp.298-300
    • /
    • 2005
  • Satellite payload on-board date compression unit are use for saving date storage space and reducing time to transmit payload data to the ground station. The KOMPSAT-3 payload will generate higher data rate than KOMPSAT-2 due to its better ground sample distance capacity. High input data rate and limited output transmission data rate might lead excessive compression and degraded image quality. This paper presents a trade-off study about data storage capacity and compression parameters for estimated KOMPSAT-3 system.

  • PDF

A Study on the two span preflex composite girder bridges with LRFD (LRFD에 의한 2경간 Preflex 합성형교에 관한 연구)

  • 구민세;박영제;오석태
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 1999.10a
    • /
    • pp.95-102
    • /
    • 1999
  • Preflex beams are prestressed by the predeflection technique, which enables the use of concrete-encased high strength steel beams where deflection or cracking of concrete, or both, would otherwise be excessive. This study presents the analysis of the two span preflex composite girder bridges with Load and Resistance Factor Design(LRFD), which is most widely used design nile in the advanced states. The results show that the comparison of LRR with Allowable Stress Design(ASD) according to span length.

  • PDF

A survey on the visual fatigue measurement methods (시각피로의 측정방법에 관한 조사연구)

  • 이남식;박재희;김유창
    • Proceedings of the ESK Conference
    • /
    • 1994.04a
    • /
    • pp.32-37
    • /
    • 1994
  • This paper surveys the various methodologies for the objective measurement of visual fatigue. Visual fatigue is a psychophysiological symtom caused by the excessive use of eyes and it can be used as an important measure of the effectiveness and the safety of visual displays. The purpose of this paper is to compare the various visual fatigue measurement methodologies in a sense of the suitability for the ergonomic research. The measurement methodologies based on accommodation, convergence, visual evoked potential, eye movement, eye blinking, and flicker fusion were discussed and compared.

  • PDF

A Study on Simultaneous Optimization for Robust Design

  • Kwon, Yong-Man
    • 한국데이터정보과학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.44-55
    • /
    • 2001
  • In the Taguchi parameter design, the product-array approach using orthogonal arrays is mainly used. However, it often requires an excessive number of experiments. An alternative approach, which is called the combined-array approach, was suggested by Welch et. al. (1990) and studied by others. In these studies, only single response variable was considered. We propose how to simultaneously optimize multiple responses when there are correlations among responses, and when we use the combined-array approach to assign control and noise factors.

  • PDF

Simultaneous Optimization of Multiple Responses Alternatives to the Taguchi Parameter Design

  • Yong Man Kwon
    • Communications for Statistical Applications and Methods
    • /
    • v.3 no.2
    • /
    • pp.103-117
    • /
    • 1996
  • In the Taguchi Parameter design, the product-array approach using orthogonal arrays is mainly used. However, it often requires an excessive number of experiments. An alternative approach, which is called the combined- array approach, was suggested by welch et. al. (1990) and studied by Vining and Myers(1990), Box and Jones (1992) and others. In these studies, only single response variable was considered. We propose how to simultaneously optimize multiple responses when there are correlations among responses, and when we use the combined-array approach to assign control and noise factors.

  • PDF

Physicochemical Properties of Artificial Soil Formulated by Blending Calcined Clay and Coconut Peat and its Effect on Plant Growth (소성 점토다공체 및 코코넛 피트를 혼합한 인공토양의 물리화학적 특성과 식물생육에 미치는 영향)

  • 허근영;강호철;김인혜;심경구
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.30 no.5
    • /
    • pp.107-115
    • /
    • 2002
  • This study was carried out to compare artificial soil formulated by blending calcined clay and coconut peat with perlite, then to evaluate this soil as a perlite substitute for use as an artificial planting medium. To achieve this, a determination of the physico-chemical properties and it's effect on plant growth were conducted by comparing those with large perlite grains and small grains. The results are summarized as follows: 1) The bulk density was 0.41g/㎤. This density was lower than that of field soil, but higher than that of large perlite grain(0.23g/㎤) and small grain(0.25g/㎤). The porosity, field capacity, and saturated hydraulic conductivity were 71.3%, 49.2%, and 3.8$\times$10-2cm/s, respectively. The air-permeability, water holding capacity, and drainage were better than or equal to that both large and small perlite grain. 2) It was near-neutral in reaction(pH=6.6). It had a high organic carbon content(65.8g/kg) and a low available phosphoric acid content(84.7mg/kg). It was similar to crop soil in cation exchange capacity(11.4cmol/kg). It had a low exchangeable calcium content(0.71cmol/kg), a low exchangeable magnesium content(0.68cmol/kg), a high exchangeable potassium content(2.54cmol/kg), and a high exchangeable sodium content(1.12cmol/kg). Except for the exchangeable potassium and sodium content, the chemical properties were better than or equal to both large and small grain perlite. The excessive exchangeable potassium or sodium content will inhibit plant growth. 3) In Experiment 1, the plant growth tended to be higher compared to that of large and small perlite gains. But in Experiment 2, it tended to be lower. This might be linked to the excessive exchangeable potassium or sodium content. 4) It could be considered as a renewable perlite substitute for greening of artificial soil. But, it would be necessary to leach the excessive exchangeable potassium or sodium to avoid the risk of inhibiting plant growth.