• Title/Summary/Keyword: Excellent facilities

Search Result 234, Processing Time 0.033 seconds

A Study on Automatic Return Dragging Detector with Real-time Data Transmission (실시간 데이터 전송이 가능한 자동 복귀형 끌림 물체 검지장치 연구)

  • Jeon, Jae-Geun;Kim, Dong-Hwan;Suh, Ki-Bum;Kim, Young
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.68 no.1
    • /
    • pp.199-206
    • /
    • 2019
  • Recently, an expansion of safety facilities has been widely applied to effectively manage the safety of train operation due to increase of the high-speed section of the general railway and the introduction of high-speed train. Accordingly, performance improvement, upgrading and high reliability of existing safety devices are required. the dragging detector, one of the safety devices, is an analogue system that consists of closed circuit with an electric current flows and operates when the closed circuit is opened by the impact of the dragging object. Such method has unreasonable problem that should be replaced after being detected. It is need to replace with an automatic return type dragging detector which is easy to maintain. In addition, it is necessary to develop a dragging detector that applicable to general railway and urban railway including high-speed railway, in accordance with the speeding up and densification of trains, although it is currently applied only to high-speed railway. In this paper, we propose an automatic return type dragging detector which has versatility and excellent maintainability with digital sensor and real time monitoring.

The Estimation of Fatigue Life for Al/CFRP Hybrid Laminated Composites using the Strain-Life Method (변형률-수명 평가기법을 이용한 Al/CFRP 하이브리드 적층 복합재의 피로수명 측정)

  • Yang, Seong Jin;Kwon, Oh Heon;Jeon, Sang Koo
    • Journal of the Korean Society of Safety
    • /
    • v.36 no.3
    • /
    • pp.7-14
    • /
    • 2021
  • Hybrid laminated Al/carbon-fiber-reinforced plastic (CFRP) composites are attracting considerable attention from industries such as aerospace and automobiles owing to their excellent specific strength and specific rigidity. However, when this material is used to fabricate high-pressure fuel storage containers subjected to repeated fatigue loads, fatigue life evaluation for the working load is regulated as an important criterion for operational safety and ease of maintenance. Among the existing evaluation methods for these vessels, the burst test and the hydraulic repeat test require expensive facilities. Thus, the present study aims to develop an improved fatigue life test for Al/CFRP laminated hybrid composites. The test specimen was manufactured using a curved mold considering the shape of a type III high-pressure storage container. The strain-life method was used for fatigue life evaluation, and the life was predicted based on the transition life. The results indicate that the more complex the CFRP stacking sequence, the longer is the transition life. This test method is expected to be useful for ensuring the fatigue safety and economy of hybrid laminate composites.

Analyzing of Solar Power Generation Cost-Benefit Using Idle Sites(Parking Lot & Rooftop): Focusing on Environmental Benefit and Social Benefit (주차장·옥상 유휴부지를 활용한 태양광발전 비용편익 분석: 환경·사회 편익 중심으로)

  • Ko, Hyung-Do;Kim, Jeong-In;Ahn, Kyoung-Jin
    • Asia-Pacific Journal of Business
    • /
    • v.13 no.2
    • /
    • pp.139-154
    • /
    • 2022
  • Purpose - This study aims to analyzing of solar power generation cost-benefit. Design/methodology/approach - We analyzed whether there is economic feasibility by selecting parking lots and idle sites located in four areas of Seoul, Gyeonggi, Chungcheong, Jeolla, and Gyeongsang areas nationwide, and analyzing site conditions and installation capacity. Findings - According to the results of the analysis, it was found that there is low profitability in Seoul, Gyeonggi and Chungcheong regions, where the solar radiation was not excellent even if REC is selected through the contract market. However, it is necessary to analyzed the economical validity the profitable validity including environmental benefits (greenhouse gas reduction, NOx, SOx reduction effect) and social benefits (renewable power supply) that is analyzed by income and operating costs which is occurred from electricity sales and REC sales when installing solar power generation facilities. Research implications or Originality - In this study, economic feasibility was evaluated additionally in consideration of environmental and social benefits. In conclusion, it was shown that businesses are not economical when considering only simple financial aspects are also sufficiently economical when it is considering environmental and social benefits.

Strategies for Improving Financial Management Performance of Exhibition and Convention Centers in Korea Based on Financial Ratio Analysis (재무비율분석에 기초한 한국 전시컨벤션센터의 재무적인 경영성과 개선전략)

  • Yongsuk Kim
    • Korea Trade Review
    • /
    • v.46 no.4
    • /
    • pp.1-16
    • /
    • 2021
  • This study suggests improvements in the management performance of the five largest exhibition and convention centers in Korea through financial ratio analysis. For this research, the financial ratios of each center were compared to the average of the centers as well as to the overall industry average during the past five years. According to the analysis results, the stability and growth ratios of the centers were excellent, but the profitability and activity ratios were poor. In particular, the ratios of profitability were in state of urgent need for improvement because they were at the level of severe deficits. It was analyzed that sales increase can be the key factor to improve centers' operation income and net profit to improve profitability. This study recommends measures to increase sales by using centers' facilities and their functions. The first is to actively host large-scale international meetings and conventions that only exhibition and convention centers can accommodate. The second is to attract brand exhibitions through strategic alliances with global Professional Exhibition Organizers (PEOs). Lastly, it is to organize sports and cultural events that are appropriate for incentive tours of associations and corporations.

An efficient numerical modeling approach for coupled electrical cabinets in nuclear power plants

  • Sudeep Das Turja;Md. Rajibul Islam;Dong Van Nguyen;Dookie Kim
    • Nuclear Engineering and Technology
    • /
    • v.56 no.9
    • /
    • pp.3512-3527
    • /
    • 2024
  • Seismic quantification of nonstructural components like electrical cabinets is essential to ensure the uninterrupted operation of nuclear facilities during earthquake events. This process requires experimental tests, which can be expensive, time-consuming, and limited by safety concerns and precision. As an alternative to that, numerical simulations should be done in such a way that they are capable of capturing the global dynamic behavior with minimum computational efforts. However, in the case of complex interconnected cabinets, the simplification of numerical models often poses difficulties in illustrating the real-time behavior of combined cabinet systems. On the other hand, detailed three-dimensional (3D) numerical models require lengthy time and sophisticated computational setup, indicating their expensive computational efforts. To resolve this issue, a simplified and efficient 3D modeling approach has been proposed in this study. The accuracy of the results from the new model showed an excellent match with that obtained from the responses of the experimental test. After the validation and observation of the numerical efficiency, a practical application is implemented by considering the impacts of earthquake frequency contents on the behavior of cabinet systems. From the outcomes, it is evident that this proposed modeling methodology has the potential to replace the complex combined nuclear cabinet models for earthquake evaluation.

A Study on Analysis of Facility Design in Recreation Forest - With a Special Reference to Chonbuk Province - (자연휴양림(自然休養林)의 시설설계(施設設計)의 분석(分析) - 전북지역(全北地域)을 중심(中心)으로 -)

  • Lee, Chang-Heon;Park, Chong-Min
    • Journal of Korean Society of Forest Science
    • /
    • v.85 no.2
    • /
    • pp.158-171
    • /
    • 1996
  • In Korea, 80,616 ha in 139 places have been designated as recreation forests by the end of 1994. Among these places, 64,547 ha in 76 places were designated in the national forest, 9,937 ha in 25 places were designated in the public forest, and 6,132 ha in 38 places were designated in private forest. Designs of 10 places and plans of 6 places in 14 places of recreation forest in Chonbuk province were compared and analyzed. The results are as follows: 1. Sixty four types of convenient facilities, 15 types of athletic facilities, 13 types of sanitation facilities, 22 types of education facilities were designed in 10 places of the recreation forest. 2. The material cost was the highest in construction costs in Waryong recreation forest. However, the labor cost was the highest one in construction costs in 5 places of recreation forest ; Dokyu-san, Hoimoon-san, Saesim, Seongsu, and Sokgeum-san And the total construction cost was much higher in private recreation forest than in both of national and public recreation forest. 3. Hoimoon-san was the only recreation forest which makes profit among 14 recreation forests in Chonbuk province. The uses of this recreation forest are increasing, and seasonal uses significantly fluctuate. 4. There are several problems for the public in enjoying these recreation forest places. The access to these places by public transportations is inconvenient. The time required for construction of many places are too long after they are designated as recreation forest, and the management of the established recreation forest is poor. 5. To improve the method of facility design in recreation forest, easy access to nature should be promoted such as recreation forest places and understanding of public concerning nature are needed. Recreation forest places themselves need to offer good facilities, and convenient access. And to make frequent use of recreation forest places, a system of information and excellent service to the public are strongly recommended.

  • PDF

The Korea Academia-Industrial cooperation Society (유리섬유 복합재료를 이용한 화재 비상통로용 스크린 소재 성능에 관한 연구)

  • Lee, Jung-Yub
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.2
    • /
    • pp.653-659
    • /
    • 2018
  • High-rise buildings and complex facilities are a representative urban system for the masses, and it requires an increasing role of commodity and safety. Smoke and toxic gasses can cause accidents due to fire in these systems. The purpose of this study is to develop a fiber screen material for emergency evacuation passages that can be avoided quickly and safely in cases of disasters. The fiber screen material is applicable to folding devices for emergency evacuation passages. The material is different from general steel material in that it is lightweight with less burden during storage for a long time in a roll form in a folding device. It also has an excellent secondary function in that it is less affected by radiant heat. Three kinds of fiber screen materials were selected that have good flame retardancy and post-processing characteristics. A performance evaluation was performed by a heat shrinkage test, contact heat test, combustibility test, flame retardancy test, tensile strength test, and tear strength test. As a result, the lightweight fabric shows excellent performance through post-processing, and silicone resin coating can secure safety of the pizza by the fiber screen material performance and radiant heat. The optimum post-treatment conditions were evaluated by performing a burning test after coating two kinds of glass fibers and four types of flame-retardant silicone resins with different weight and thickness.

Case Studies on Distributed Temperature and Strain Sensing(DTSS) by using an Optical fiber (광섬유 센서를 이용한 온도 및 변형 모니터링에 대한 현장응용 사례)

  • Kim, Jung-Yul;Kim, Yoo-Sung;Lee, Sung-Uk;Min, Kyoung-Ju;Park, Dong-Su;Pang, Gi-Sung;Kim, Kang-Sik
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2006.03a
    • /
    • pp.86-95
    • /
    • 2006
  • Brillouin backscatter is a type of reflection that occurs when light is shone into an optical fibre. Brillouin reflections are very sensitive to changes in the fibre arising from external effects, such as temperature, strain and pressure. We report here several case studies on the measurement of strain using Brillouin reflections. A mechanical bending test of an I beam, deployed with both fiber optic sensors and conventional strain gauge rosettes, was performed with the aim of evaluating: (1) the capability and technical limit of the DTSS technology for strain profile sensing; (2) the reliability of strain measurement using fiber optic sensor. The average values of strains obtained from both DTSS and strain gauges (corresponding to the deflection of I beam) showed a linear relationship and an excellent one-to-one match. A practical application of DTSS technology as an early warning system for land sliding or subsidence was examined through a field test at a hillside. Extremely strong, lightweight, rugged, survivable tight-buffered cables, designed for optimal strain transfer to the fibre, were used and clamped on the subsurface at a depth of about 50cm. It was proved that DTSS measurements could detect the exact position and the progress of strain changes induced by land sliding and subsidence. We also carried out the first ever distributed dynamic strain measurement (10Hz) on the Korean Train eXpress(KTX) railway track in Daejeon, Korea. The aim was to analyse the integrity of a section of track that had recently been repaired. The Sensornet DTSS was used to monitor this 85m section of track while a KTX train passed over. In the repaired section the strain increases to levels of 90 microstrain, whereas in the section of regular track the strain is in the region of 30-50 microstrain. The results were excellent since they demonstrate that the DTSS is able to measure small, dynamic changes in strain in rails during normal operating conditions. The current 10km range of the DTSS creates a potential to monitor the integrity of large lengths of track, and especially higher risk sections such as bridges, repaired track and areas at risk of subsidence.

  • PDF

Practice and Improvement Scheme of Management of Human Resources in Korean Private Security Service Industry (한국 민간경비 인적자원 확보관리의 실태 및 개선방안)

  • Suh, Sang-Yul;Park, Jun-Seok
    • Korean Security Journal
    • /
    • no.16
    • /
    • pp.81-99
    • /
    • 2008
  • Despite its legal, systematic and quantitative growth, Korean private security has not been showing satisfactory level of qualitative growth comparing to quantitative growth as it socially shocked with recent occurrence of the events and accidents. People on demand of security are making use of private security service to offset insufficient supply of security power as, especially, the incendiarism at Sungryemun last February brought out security issues for nationally important facilities and cultural assets, and other cases showed that the police would not cope with the appropriate security services under the current security system for protecting the life and property of people. For the supplementation of security power, the private security service is prevalent, but lots of service providers would not overcome its small business scale, except some large-sized security providers. There are some problem occurred as some providers employed staff who would not have the stuff for performing security service and they even committed illegal actions. Some opinions pointed out that it should come up with measures as they socially lose their credit. Therefore, this research suggests the recognition of the importance and the improvement measures of human resources management as follows. Security Service needs: 1. control of criteria for the employment/recruitment of human resources; 2. inducement of qualitative improvement of security service by ensuring excellent quality of human resources; 3. elevation of morale of organizational members with the operation of efficient promotion system; 4. introduction of professional certification system for the inflow of excellent quality of human resources.

  • PDF

Study of Structural Stability and Seismic Performances of 4-Way Sway Prevention Brace (4방향흔들림방지버팀대의 구조 안정성 및 내진 성능 연구)

  • O, Soo Un;Lee, Hang Jun;Choa, Sung Hoon
    • Journal of the Society of Disaster Information
    • /
    • v.18 no.3
    • /
    • pp.646-659
    • /
    • 2022
  • Purpose: In this study, we developed a 4-way sway prevention brace that efficiently reduces the installation area and has excellent stability and seismic performance compared to the conventionl sway prevention brace used in existing firefighting facilities. The performance and reliability of the developed 4-way way prevention brace were analyzed by the tensile, compression tests and seismic tests. Method: As the static test, 4-way sway prevention braces were installed on the horizontal and vertical pipes to perform the tensile and compression tests based on the KFI certification standard and the maximum movement was measured at the rated load. As a dynamic test, 4-way sway prevention braces were installed in the pipes filled with water, and the test response spectrum to the input excitation wave were measured through the acceleration sensors. After the seismic tests, separation, failure, and local deformation of the pipes, and 4-way sway prevention braces were not observed. Result: The results of the tensile and compression tests indicated that the maximum movement of the pipe during tension and compression was 50% to 70% or less compared to the certification values, indicating that the performances of the 4-way sway prevention braces were very excellent. The results of the the seismic tests indicated that the test response spectrum of the 4-way sway prevention braces is within the required response spectrum. Conclusion: In this study, it was found that the 4-way sway prevention braces satisfied the KFI certification standard and were superior compared to the existing sway prevention brace in terms of the stability, cost, and installation area.