• Title/Summary/Keyword: Exact test

Search Result 1,479, Processing Time 0.027 seconds

Development and Effectiveness of Learning Programs on Visualization of Data for Gifted Students in Elementary School Science - Focusing on Using the Tableau Program - (초등학교 과학영재 학생을 대상으로 한 데이터 시각화 학습 프로그램 개발 및 효과 - Tableau 프로그램 활용을 중심으로 -)

  • Kim, Hyunguk
    • Journal of Korean Elementary Science Education
    • /
    • v.43 no.1
    • /
    • pp.18-34
    • /
    • 2024
  • This study aimed to examine the effects of a science-learning program based on data visualization on the science inquiry and creative problem-solving abilities of elementary school science-gifted students. Accordingly, this research developed a data visualization science-learning program using Tableau, which had twelve sessions. The subjects encompassed 61 students in three gifted classes taught by the researcher. The scientific inquiry ability test and creative problem-solving ability test modified to suit the environment and situation were given to the subjects before and after the treatment. The results confirmed that science learning based on data visualization had no significant impact on basic science inquiry skills. Among the subdomains, significant results were obtained only in the reasoning subdomain. Moreover, integrative inquiry ability was significantly affected, unlike basic inquiry abilities. Among the five subdomains, significant differences were observed in three subdomains (data conversion, data interpretation, and variable control). However, concerning the generation of hypotheses and the control of variables, students exhibited confusion regarding the process of variable control and the exact concept of hypothesis development. This study also evaluated the effects of the program's application on creative problem-solving abilities and found a significant impact. Additionally, it was significantly different in all four subdomains. The results were interpreted to be owing to the students' mastery of Tableau's features, collaborative learning through discussion and debate, and the thematic impact of the data visualization program emphasizing procedural thinking. Finally, this study presented implications for science learning based on data visualization and the future direction of education.

A Study on the Accelerated Life Test for the Estimation of Licorice Durability in Cosmetics (화장품 중 유용성감초추출물의 유통기한 예측을 위한 가속수명 시험연구)

  • Lee, So-Mi;Joo, Kyeong-Mi;Park, Jong-Eun;Jeong, Hye-Jin;Chang, Ih-Seop
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.33 no.3
    • /
    • pp.197-201
    • /
    • 2007
  • Oil soluble licorice extract(licorice extract) is an officially approved cosmetic component as a whitening ingredient in Korea. The durability of licorice, during which the whitening effect can be maintained in optimum condition, must be accurately defined. Since the cosmetics durability under real condition is relatively longer than its development time. It is needed to predict the real durability interval from the experimental measurement under simulated operating conditions. We analyzed the relationship between the licorice lifetime and the high temperature condition by using Arrhenius equation. We have established the constant stress test with temperature of $50^{\circ}C$, $55^{\circ}C$, and $60^{\circ}C$ condition, within which no formulation change of licorice products is expected for the accelerated stress test. In this paper, the lifetime of licorice in cosmetics was defined as time period for its 10% contents reduction. We observed that the lifetime of licorice is 580 h at $50^{\circ}C$, 319 h at $55^{\circ}C$ and 166 h at $60^{\circ}C$. Using the above experimental data, we obtained the equation for the relationship between the licorice lifetime and temperature as follows; log(lifetime)=-35.0243 + 1.15322$\times$(11604.83/temperature). From this equation, the lifetime of licorice at $25^{\circ}C$ can be estimated as 26 months. The estimated result was verified by measuring full lifetime of licorice. In fact, there was no significant difference between the estimated lifetime and real measurement within 95 % significance level. This study can be applied to other useful cosmetic components for the fast estimation of the exact durability.

Usefulness of CTAC Shift Revision Method of Artifact by Diaphragm in PET/CT (PET/CT 검사에서 횡격막에 의한 인공물의 CTAC Shift 보정방법의 유용성)

  • Ham, Jun Cheol;Kang, Chun Koo;Cho, Seok Won;Bahn, Young Kag;Lee, Seung Jae;Lim, Han Sang;Kim, Jae Sam;Lee, Chang Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.1
    • /
    • pp.71-75
    • /
    • 2013
  • Purpose: Currently, decrement revision using LDCT is used in PET/CT. But cold artifacts are often found in decrement revision image by mismatch between LDCT image and Emission image near diaphragm due to patient's respiration. This research studied reduction of cold artifact by patient's respiration using CTAC Shift among revision methods. Materials and Methods: From March to September in 2012, 30 patients who had cold artifacts by respiration were targeted using PET/CT Discovery 600 (GE Healthcare, MI, USA) equipment. Patients with cold artifacts were additionally scan in diaphragm area, and the image shown cold artifacts at whole body test were revised using CTAC Shift. Cold artifacts including image, additional scan image and CTAC Shift revision image were evaluated as 1~5 points with naked eye by one nuclear medicine expert, 4 radiotechnologists with over 5 year experience. Also, standard uptake value of 3 images was compared using paired t-test. Results: Additional scan image and CTAC Shift revision image received relatively higher score in naked eye evaluation than cold artifacts including image. The additional scan image and CTAC Shift revision image had high correlation as the results of ANOVA test of standard uptake value and did not show significant difference. Conclusion: When cold artifacts are appeared by patient's respiration at PET/CT, it causes not only patient inconvenience but troubles in test schedule due to extra radiation exposure and time consumption by additional scan. But if CTAC Shift revision image can be acquired with out additional scan, it is considered to be helped in exact diagnosis without unnecessary extra radiation exposure and additional scan.

  • PDF

Evaluation of dietary behavior and investigation of the affecting factors among preschoolers in Busan and Gyeongnam area using nutrition quotient for preschoolers (NQ-P) (미취학 아동 대상 영양지수 (nutrition quotient for preschoolers, NQ-P)를 이용한 부산·경남지역 미취학 아동의 식행동 평가 및 영향요인 규명)

  • Kim, Soo-Youn;Cha, Sung-Mi
    • Journal of Nutrition and Health
    • /
    • v.53 no.6
    • /
    • pp.596-612
    • /
    • 2020
  • Purpose: This study was conducted to evaluate the dietary behaviors of preschool children using the nutrition quotient for preschoolers (NQ-P) and investigate factors that influence NQ-P in preschool children. Methods: Subjects were 214 parents with children aged 3-5 years residing in Busan and Gyeongnam, Korea. The survey was conducted from March to April, 2019 using a questionnaire that included demographic characteristics, the NQ-P questions, and health consciousness. All data was statistically analyzed by the SPSS program (Ver 25.0) and the statistical differences in variables were evaluated by the chi-square test, Fisher's exact test, t-test, one-way ANOVA, and Tukey's multiple comparison test. Results: The mean score of NQ-P of the total subjects was 58.28, which was within the medium-low grade. The mean score of 'balance' was 60.08, 'moderation' was 47.64, and 'environment' was 67.83. The analysis of related-factors influencing NQ-P scores showed that there was a significant difference according to the frequency of dining out. The scores of the NQ-P (p < 0.05), moderation (p < 0.001), and environment (p < 0.05) were significantly higher in the 1-2 times per week group compare to 3-4 times and 5-6 times per week group. The scores of NQ-P (p < 0.01), environment (p < 0.01) were significantly higher in the high group of parents' health consciousness compared to the those with low health consciousness. Conclusion: According to the results of the evaluation by NQ-P, the dietary behaviors of preschool children residing in Busan and Gyeongnam need to be improved and monitored. For improving their eating behavior and nutritional health status, preschool children and their parents need proper nutrition education programs.

An Estimation of the Efficiency and Satisfaction for EEG Practice Using the Training 10-20 Electrode System: A Questionnaire Survey (연습용 10-20 Electrode System을 이용한 뇌파검사 실습의 효율성과 만족도 평가)

  • Lee, Chang Hee;Kim, Dae Jin;Choi, Jeong Su;Lee, Jong-Woo;Lee, Min Woo;Cho, Jae Wook;Kim, Suhng Wook
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.49 no.3
    • /
    • pp.300-307
    • /
    • 2017
  • Electroencephalography (EEG) is distinct from other medical imaging tests in that it is a functional test that helps to diagnosis disorders related to the brain, such as epilepsy. The most important abilities for a medical technologist when performing an EEG are knowing the exact location of the electrode and recording the EEG wave clearly, except for artifacts. Although theoretical education and practical training are both included in the curriculum for improving these abilities, sufficient practical training has been lacking due to problems like expensive equipment and insufficient practical training time. We try to solve these issues by manufacturing the training 10-20 electrode system and by estimating the efficiency and satisfaction of the training 10-20 electrode system through a questionnaire. The time required for practical training using this system was $43.58{\pm}9.647min$, which proved to be efficient. The satisfaction score of participants who experienced curriculum practical training was improved from $7.21{\pm}2.285$ to $9.46{\pm}1.166$. Based on these findings, it is considered that practical training via the use of the training 10-20 electrode system will solve the problems, such as lack of equipment and insufficient practical training time. Nonetheless, to further improve the training 10-20 electrode system, it must overcome the limitations of developing a device capable of checking the actual brain waves and validating the exact location of electrode attachment.

Relationships between Dietary Behaviors with Smoking, Drinking Situations and Subjective Health Status of University Students (대학생의 식행동, 흡연, 음주실태와 주관적 건강상태와의 관련성)

  • Kwon, Soo-Jin;Kang, Ji-Hea;Kim, Na-Jung;Kim, Rye-Jin;Kim, Suhn-young;Kim, Si-Il;Han, Gyeong-Soon
    • Journal of dental hygiene science
    • /
    • v.12 no.2
    • /
    • pp.145-153
    • /
    • 2012
  • This study aims at investigate dietary behaviors, smoking and drinking status of university students depending on their gender and residential patterns, and analyzing relationships with their subjective health status. The subjects of this study was 538 university students in Metropolitan areas from May 10-31, 2010. Data were analyzed with chi-square test, fisher's exact test, t-test and stepwise multiple regression SPSS 12.0. Male students higher frequency on the intake of eggs, meats and carbonated drinks than female students. The group residing at one's own house showed higher frequency on the intake of beans, fruits and milk than the self-boarding group or other groups(p<0.05), while preferring sweet taste the most. Male students were significantly higher than female students in the amount of smoking and drinking(p<0.05). They had positive recognition on their health conditions as they have higher frequency on the intake of potatoes, seaweeds, green tea and milk with less frequency on the intake of eggs, fast foods and drinking amount. Accordingly, it was considered necessary to have continuous education on nutrition and social supports to prevent their dietary behaviors from leaning on convenience or preference.

Effectiveness of Soft Stimulation Protocol, Compared with Conventional GnRH Antagonist Multiple dose Protocol in Patients Undergoing Controlled Ovarian Stimulation with Intrauterine Insemination (과배란유도하 자궁강내 인공수정시술을 받는 환자에서 연성자극요법과 성선자극호르몬 길항제 다회투여법의 효과 비교)

  • Kim, Chung-Hoon;Kang, Hyuk-Jae;Kim, So-Ra;Jeon, Gyun-Ho;Lee, Hyang-Ah;Kim, Sung-Hoon;Chae, Hee-Dong;Kang, Byung-Moon
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.37 no.2
    • /
    • pp.135-142
    • /
    • 2010
  • Objective: To evaluate the effectiveness of soft stimulation protocol using GnRH antagonist/clomiphene citrate (CC)/recombinant FSH (rFSH) in patients undergoing controlled ovarian stimulation (COS) with intrauterine insemination (IUI), compared with GnRH antagonist multiple dose protocol (MDP) using GnRH antagonist/rFSH. Methods: Eighty infertile women were randomized to soft stimulation protocol group (n=40) or GnRH antagonist MDP group (n=40). In both groups, IUI was performed 36~40 hours after hCG injection. Statistical analysis was performed using Student's t-test, $\chi^2$ test or Fisher's exact test as appropriate. Results: Total dose and days of rFSH required for COS were significantly fewer in soft stimulation protocol group (p<0.001, p<0.001). A premature LH surge did not occur in any patients of both groups. Clinical pregnancy rate per cycle was similar between the two groups. Conclusion: Soft stimulation protocol provides comparable pregnancy rates to GnRH antagonist MDP despite fewer total dose and days of rFSH, and so can become one of the patient-friendly, cost-effective alternatives for infertile patients undergoing COS with IUI.

Evaluation of Dark Spots Formated on the High Temperature Metal Filter Elements (고온 금속필터 element 표면에 생성된 반점에 대한 평가)

  • Park, Seung-Chul;Hwang, Tae-Won;Moon, Chan-Kook
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.6 no.3
    • /
    • pp.171-178
    • /
    • 2008
  • Metal filter elements were newly introduced to the high temperature filter(HTF) system in the low- and intermediate-level radioactive waste vitrification plant. In order to evaluate the performance of various metal materials as filter media, elements made of AISI 316L, AISI 904L, and Inconel 600 were included to the test set of filter elements. At the visual inspection to the elements performed after completion of each test, a few dark spots were observed on the surface of some elements. Especially they were found much more at the AISI 316L elements than others. To check the dark spots are the corrosion phenomena or not, two kinds of analyses were performed to the tested filter elements. Firstly, the surfaces or the cross sections of filter specimens cut out from both normal area and dark spot area of elements were analyzed by SEM/EDS. The results showed that the dark spots were not evidences of corrosion but the deposition of sodium, sulfur and silica compounds volatilized from waste or molten glass. Secondly, the ring tensile strength were analyzed for the ring-shape filter specimens cut out from each kind of element. The result obtained from the strength tested showed no evidence of corrosion as well. Conclusionally, depending on the two kinds of analysis, no evidences of corrosion were found at the tested metal filter elements. But the dark spots formed on the surface could reduce the effective filtering area and increase the overall pressure drop of HTF system. Thus, continuous heating inside filter housing up to dew point will be required normally. And a few long-period test should be followed for the exact evaluation of corrosion of the metal filter elements.

  • PDF

Value of Pulmonary Function Test as a Predicting Factor of Pneumothorax in CT-guided Needle Aspiration of the Lung (전산화단층촬영 유도하 경피적 폐침생검시 기흉발생 예측인자로써의 폐기능검사의 가치)

  • Kim, Yeon-Jae;Kim, Chang-Ho;Lee, Yeung-Suk;Park, Jae-Yong;Kang, Duk-Sik;Jung, Tae-Hoon
    • Tuberculosis and Respiratory Diseases
    • /
    • v.40 no.3
    • /
    • pp.259-266
    • /
    • 1993
  • Background: To evaluate the risk factor of pneumothorax (PNX) which is the most common complication of CT-guided needle aspiration of the lung, we have examined the frequency of PNX according to the presence of obstructive ventilatory impairment determined by pulmonary function tests. Methods: A comparative study of analysis of forecd expiratory volume and folw-volume curves, and determinations of diffusing capacity taken before procedure were made between each 16 cases with PNX and controls with no PNX. Each of the control group was matched for sex, age, height, and size and depth of lesion with the former. Results: 1) In comparison of vital capacity and parameters derived from forced expiratory volume curve between two groups, VC and FVC were not significantly different, whereas $FEV_1$, $FEV_1$/FVC%, and FEF25-75% showed a significant decrease in the PNX gorup. Also, in the PNX group, all the observed values of parameters analyzed from flow-volune curve were siginificantly reduced in the PNX group compared with those in the control group. 2) The diffusing capacity tended to decrease along with varying individual differences in the PNX group. 3) Patients who had obstructive ventilatory impairment according to the results of pulmonary function tests experienced a twofold increase in the frequency of PNX and a sixfold increase in the frequency of chest tube drainage for treatment of PNX compared with those whose results were normal. Conclusion: These findings suggest that the exact evaluation of obstructive lung disease determined by pulmonary function test be considered assessing a pastient's risk for PNX in the patients who will take the CT-guided needle aspiration of the lung.

  • PDF

The Influence of Iteration and Subset on True X Method in F-18-FPCIT Brain Imaging (F-18-FPCIP 뇌 영상에서 True-X 재구성 기법을 기반으로 했을 때의 Iteration과 Subset의 영향)

  • Choi, Jae-Min;Kim, Kyung-Sik;NamGung, Chang-Kyeong;Nam, Ki-Pyo;Im, Ki-Cheon
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.1
    • /
    • pp.122-126
    • /
    • 2010
  • Purpose: F-18-FPCIT that shows strong familiarity with DAT located at a neural terminal site offers diagnostic information about DAT density state in the region of the striatum especially Parkinson's disease. In this study, we altered the iteration and subset and measured SUV${\pm}$SD and Contrasts from phantom images which set up to specific iteration and subset. So, we are going to suggest the appropriate range of the iteration and subset. Materials and Methods: This study has been performed with 10 normal volunteers who don't have any history of Parkinson's disease or cerebral disease and Flangeless Esser PET Phantom from Data Spectrum Corporation. $5.3{\pm}0.2$ mCi of F-18-FPCIT was injected to the normal group and PET Phantom was assembled by ACR PET Phantom Instructions and it's actual ratio between hot spheres and background was 2.35 to 1. Brain and Phantom images were acquired after 3 hours from the time of the injection and images were acquired for ten minutes. Basically, SIEMENS Bio graph 40 True-point was used and True-X method was applied for image reconstruction method. The iteration and Subset were set to 2 iterations, 8 subsets, 3 iterations, 16 subsets, 6 iterations, 16 subsets, 8 iterations, 16 subsets and 8 iterations, 21 subsets respectively. To measure SUVs on the brain images, ROIs were drawn on the right Putamen. Also, Coefficient of variance (CV) was calculated to indicate the uniformity at each iteration and subset combinations. On the phantom study, we measured the actual ratio between hot spheres and back ground at each combinations. Same size's ROIs were drawn on the same slide and location. Results: Mean SUVs were 10.60, 12.83, 13.87, 13.98 and 13.5 at each combination. The range of fluctuation by sets were 22.36%, 10.34%, 1.1%, and 4.8% respectively. The range of fluctuation of mean SUV was lowest between 6 iterations 16 subsets and 8 iterations 16 subsets. CV showed 9.07%, 11.46%, 13.56%, 14.91% and 19.47% respectively. This means that the numerical value of the iteration and subset gets higher the image's uniformity gets worse. The range of fluctuation of CV by sets were 2.39, 2.1, 1.35, and 4.56. The range of fluctuation of uniformity was lowest between 6 iterations, 16 subsets and 8 iterations, 16 subsets. In the contrast test, it showed 1.92:1, 2.12:1, 2.10:1, 2.13:1 and 2.11:1 at each iteration and subset combinations. A Setting of 8 iterations and 16 subsets reappeared most close ratio between hot spheres and background. Conclusion: Findings on this study, SUVs and uniformity might be calculated differently caused by variable reconstruction parameters like filter or FWHM. Mean SUV and uniformity showed the lowest range of fluctuation at 6 iterations 16 subsets and 8 iterations 16 subsets. Also, 8 iterations 16 subsets showed the nearest hot sphere to background ratio compared with others. But it can not be concluded that only 6 iterations 16 subsets and 8 iterations 16 subsets can make right images for the clinical diagnosis. There might be more factors that can make better images. For more exact clinical diagnosis through the quantitative analysis of DAT density in the region of striatum we need to secure healthy people's quantitative values.

  • PDF